EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Parker
  6. •
  7. Water Pump
  8. •
  9. Parker P2 Series User manual

Parker P2 Series User manual

Other manuals for P2 Series

1

This manual suits for next models

1

Other Parker Water Pump manuals

Parker PGP 505 User manual

Parker

Parker PGP 505 User manual

Parker HP2 Series Manual

Parker

Parker HP2 Series Manual

Parker PGM 600 Series User manual

Parker

Parker PGM 600 Series User manual

Parker F1 Series User manual

Parker

Parker F1 Series User manual

Parker F3 Series Installation and operation manual

Parker

Parker F3 Series Installation and operation manual

Parker F12 series User manual

Parker

Parker F12 series User manual

Parker 47 Series Installation manual

Parker

Parker 47 Series Installation manual

Parker COMPAX P1 Series Operating and installation instructions

Parker

Parker COMPAX P1 Series Operating and installation instructions

Parker Series V14 User manual

Parker

Parker Series V14 User manual

Parker eP2 Series User guide

Parker

Parker eP2 Series User guide

Parker COMPAX P1 Series Manual

Parker

Parker COMPAX P1 Series Manual

Parker P2 Series User manual

Parker

Parker P2 Series User manual

Parker Commercial Hydraulics PGP030/031 Series User manual

Parker

Parker Commercial Hydraulics PGP030/031 Series User manual

Parker Parflex User manual

Parker

Parker Parflex User manual

Parker P1/PD Series Operating and installation instructions

Parker

Parker P1/PD Series Operating and installation instructions

Parker A4W Series User manual

Parker

Parker A4W Series User manual

Parker AHL Series User manual

Parker

Parker AHL Series User manual

Parker VP1-110 Series Installation and operation manual

Parker

Parker VP1-110 Series Installation and operation manual

Parker 44 Series Installation manual

Parker

Parker 44 Series Installation manual

Parker F2 Series User manual

Parker

Parker F2 Series User manual

Parker PGP300 Series User manual

Parker

Parker PGP300 Series User manual

Parker Series VP1-045/-075 Installation and operation manual

Parker

Parker Series VP1-045/-075 Installation and operation manual

Parker Denison GOLD CUP series User manual

Parker

Parker Denison GOLD CUP series User manual

Parker F12 series User manual

Parker

Parker F12 series User manual

Popular Water Pump manuals by other brands

Neptun NPHW 5500 operating instructions

Neptun

Neptun NPHW 5500 operating instructions

Sensidyne Gilian BDX-II Operation & service manual

Sensidyne

Sensidyne Gilian BDX-II Operation & service manual

Draper 47808 instructions

Draper

Draper 47808 instructions

Trolla 12820 manual

Trolla

Trolla 12820 manual

Sunfab SVH Series installation guide

Sunfab

Sunfab SVH Series installation guide

WilTec 50740 Operation manual

WilTec

WilTec 50740 Operation manual

Fieldmann FVC 5015 EK user manual

Fieldmann

Fieldmann FVC 5015 EK user manual

Everbilt EFSUB5-122HD Use and care guide

Everbilt

Everbilt EFSUB5-122HD Use and care guide

Graco Husky 3300e manual

Graco

Graco Husky 3300e manual

esotec 101018 operating manual

esotec

esotec 101018 operating manual

Becker BASIC VASF 2.80/1-0.AC230 operating instructions

Becker

Becker BASIC VASF 2.80/1-0.AC230 operating instructions

Sykes AmeriPumps GP100M Operation and maintenance instructions

Sykes AmeriPumps

Sykes AmeriPumps GP100M Operation and maintenance instructions

DUROMAX XP WX Series user manual

DUROMAX

DUROMAX XP WX Series user manual

BRINKMANN PUMPS SBF550 operating instructions

BRINKMANN PUMPS

BRINKMANN PUMPS SBF550 operating instructions

Franklin Electric IPS Installation & operation manual

Franklin Electric

Franklin Electric IPS Installation & operation manual

Xylem e-1532 Series instruction manual

Xylem

Xylem e-1532 Series instruction manual

Milton Roy PRIMEROYAL instruction manual

Milton Roy

Milton Roy PRIMEROYAL instruction manual

STA-RITE ST33APP owner's manual

STA-RITE

STA-RITE ST33APP owner's manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

PUMP AND MOTOR DIVISION
Neefestraße 96
09116 Chemnitz, Germany
INSTALLATION MANUAL
SERIES P2 and P3
MOBILE PISTON PUMP
www.comoso.com
PUMP AND MOTOR DIVISION
Neefestraße 96
09116 Chemnitz, Germany
1 Check model code / compare with your paper work
Nameplate of the pump Ordering / Sales Acknowledgement
2 Check rotation of the pump
Clockwise rotation (right) - side ported P2
Clockwise rotation (right) – thru drive P3
Counter clockwise rotation (right) - side ported P2
Counter clockwise rotation (right) – thru drive P3
www.comoso.com
PUMP AND MOTOR DIVISION
Neefestraße 96
09116 Chemnitz, Germany
3 Suction, pressure and drain line connection
3.1 Connection P2
Minimum pump inlet pressure under static and dynamic load: p
in min
= 0,8 bar absolute
Maximum pump inlet pressure: p
in max
= 10 bar
Arrangement outside tank.
Fill pump case with oil before start.
Do not restrict suction line.
Arrangement outside tank.
Fill pump case with oil before start.
Do not restrict suction line.
3.1.1 Arrangements P2
www.comoso.com
PUMP AND MOTOR DIVISION
Neefestraße 96
09116 Chemnitz, Germany
Arrangement outside tank.
Fill pump case with oil before start.
Do not restrict suction line.
Arrangement outside tank.
Fill pump case with oil before start.
Do not restrict suction line.
Preferred arrangement for best suction
characteristics + low noise level operation
3.1.2 Drain line connection P2
OPTION!
Connect highest drain port with a separate line
reduced in size for purging the air out of the case
AND
secondary drain port has to be connected as
main drain line.
www.comoso.com
PUMP AND MOTOR DIVISION
Neefestraße 96
09116 Chemnitz, Germany
WARNING!
Don not combine drain lines.
Maximum continuous case pressure:
p
case
= 0,5 bar
Maximum intermittent peak case pressure:
p
case
= 2 bar
WARNING!
Don not restrict drain line.
A restricted drain line can damage the pump.
www.comoso.com
PUMP AND MOTOR DIVISION
Neefestraße 96
09116 Chemnitz, Germany
3.2 Connection P3
Minimum pump inlet pressure under static and dynamic load: p
in min
= 0,8 bar absolute
Maximum pump inlet pressure: p
in max
= 1 bar
Arrangement outside tank.
Fill pump case with 0.5 l of fluid prior to start up.
Do not restrict suction line.
Arrangement outside tank.
Fill pump case with 0.5 l of fluid prior to start up.
Do not restrict suction line.
3.2.1 Arrangements P3
Arrangement outside tank.
Fill pump case with 0.5 l of fluid prior to start up.
Do not restrict suction line.
Arrangement outside tank.
Fill pump case with 0.5 l of fluid prior to start up.
Do not restrict suction line.
Preferred arrangement for best suction
characteristics + low noise level operation
www.comoso.com
PUMP AND MOTOR DIVISION
Neefestraße 96
09116 Chemnitz, Germany
3.2.2 Drain line connection P3
OPTIONAL AIRBLEED
CONNECTION
Connect compensator drain line with the reservoir.
Keep inlet and drain line separate (hot loop).
ATTENTION!
Combination and restriction of compensator
drain line may result an back pressure.
Maximum continuous drain line pressure:
p
drain
= 2 bar
Maximum intermittent peak drain line pressure:
p
drain
= 4 bar
www.comoso.com
PUMP AND MOTOR DIVISION
Neefestraße 96
09116 Chemnitz, Germany
3.2.3 P3 pumps with drain port in the rear cover
The main benefit of this version is a continuous cooling flow through the case. Thus a better volumetric efficiency
is provided. Flow out of the drain port can be up to ~ 50 l/min and is depending on back pressure in the drain line
as well as drive speed.
Drain Port on both
sides available
Beneath the design itself pumps with inlet drain
port configuration can be identified by the last
(25
th
) digit of the order code.
If this one is D or Edrain line has to be connected
to the drain port in rearcover.
In case of U or Pthe pump still features a
compensator with drain port (see installation
manual, pages 3 and 4).
Shipping plug in
covers with drains
only
Drain line has to be connected directly to
the tank.
Max. drain line pressure:
p
drain
= 0,5 bar
www.comoso.com
PUMP AND MOTOR DIVISION
Neefestraße 96
09116 Chemnitz, Germany
4 Start up
Prior to start up, the pump case must be filled with hydraulic fluid (use case drain port). Initial start up should be
at zero pressure with an open circuit to enable the pump to prime. Pressure should only be increased once the
pump has been fully primed.
5 Hydraulic fluid
5.1 Recommended Fluids
• Normal mineral oil
• Premium hydraulic fluid / HLP oil
• Biodegradable hydraulic fluid
• Synthetic hydraulic fluid
• Fire resistant fluids
Remark:
Maximum system pressure reduced to 210 bar for water based fluids.
Bearing life time reduced to 25 % by using water based fluids.
5.2 Cleanliness level
Recommendation for maximized component life and reliability:
Class 21 / 18 / 14 according to ISO 4406
5.3 Viscosity range
Minimum viscosity for short periods: 10 mm²/s (cSt)
Normal operating viscosity: 15 – 40 mm²/s (cSt)
Maximum viscosity for short periods: 1000 mm²/s (cSt)
6 Temperature
6.1 Check hydraulic fluid specification for chemical resistance of seal material!
6.2 Check temparture range of seal material and compare with maximum system and
ambient temperature!
N– Nitrile, single shaft seal - 40°C to + 90°C
D– Nitrile, double shaft seal - 40°C to + 90°C
V– Fluorocarbon, single shaft seal - 15°C to + 150°C
T– Fluorocarbon, double shaft seal- 15°C to + 150°C
Remark:
The highest fluid temperature will be at the drain port of the pump, up to 20°C higher than in the reservoir.
www.comoso.com