ParTech EverServ 6000 User manual

[©Copyright2011ParTech,Inc.Allrightsreserved.]page1772228802
EverServ ™ 6000 POS Terminal Setup Guide
M
ThankYou!
ThankyouforpurchasingaPARpoint‐of‐salesystem.We
areconfidentthatourtechnologysolutionswillcontribute
toyourbusinesssuccess.
ExaminetheShipment:
Usetheinvoicetoensureallequipmentispresent.
ReportanymissingordamagedequipmenttoyourPAR
salesperson.
InventoryComponents:
EnsureyouhavethefollowingitemsinyourPOSorder:
POSterminal
ACpowercord
2Serialadaptercables
Note:TheEverServ6000POSdoesnothaveDB9serial
connections.TheEverServ6000POShasRJ‐45serial
connections.ThereforeserialperipheralswithDB9
connectorsrequireanRJ‐45toDB9adaptercablewhen
usedwiththeEverServ6000POSterminal.Thisadapter
cablecanbepurchasedfromPAR,partnumberC4823‐01.
ContactPARPartsat1‐800‐PAR‐PART.
ProductOverview
EverServ
6000CounterTopPOSModels
M7115‐01:EverServ6000CounterTopPOSwith
resistivetouchscreen
M7125‐01:EverServ6000CounterTopPOSwith
capacitivetouchscreen
TheCounterTopPOSiscapableofsupportinganoptional
I/Oexpansionboard(F7820)inthepedestal,whichallows
foradditionalconnectionports.See“OptionalExpansion
Board–F7820.”
ServiceandSupport
Forserviceandsupportduringorafterinstallation,contact
thePARPhoneCenterat1‐800‐458‐6898.
EverServ6000POSTerminalOverview
11PowerButton16COM1–RJ‐45Port21Printer26DCPower
1212VPowerJack17COM2–RJ‐45Port22CashDrawer127HardDriveLED
13AudioIn 18Ethernet23CashDrawer228PowerLED
14AudioOut19USBPort24DVIVideo29 KVSLED
15Microphone20USBPort25PS2
1PowerLED6RightSideCableWellCover
2TouchScreen77‐in.CustomerDisplay(F788X)
3LeftSideCableWell 8Pedestal‐Mount4x20CustomerDisplay(F7611)
4PanelMount4x20CustomerDisplay(F7601)9PowerButton
5OperatorMSR(F730X)10MainCableWell
*Formoreinformationonavailablefeatures,contactyoursalesrepresentative.
POSTerminal
MainCableWell
1
2
3
4
10
5
6
8
7
9
1112
1316
27
26
18
25
21
2414151719202223
28
29
30
31
32
33
34
35
36
38
39
37
LeftSideCableWell
RightSideCableWell
30USBPort33COM6–RJ‐45SerialPort
31USBPort34COM5–RJ‐45SerialPort
3212VDC3512VPoweredUSBPort
3624VPoweredUSBPort
37RS‐485(KVS)
38PowerLED
39
DC Power Connection
OptionalExpansionBoard(F7820)
POSDimensions

[©Copyright2011ParTech,Inc.Allrightsreserved.]page2772228802
EverServ ™ 6000 POS Terminal Setup Guide
ConnectingYourPeripherals
RemoveCoverstoAccessConnectionPanels
1.Laytheterminalonthecounteronitsbackwiththebottomfacing
you.
2.Tiltthetopcoverup.
3.Loosentheknurledthumbscrewsandremovethemaincable
connectioncoverfromthedisplayassembly.Setthecableconnection
coveraside.
4.Loosenthetwocaptivescrewsthatsecuretheleftsideconnection
panelcovertotheterminal.
5.Removethesideconnectionpanelcover.
6.Repeatsteps4and5ontherightsideoftheterminaltoremovethe
rightsidecableconnectionpanelcover.
7.Onthebottomoftheterminal,loosenthetoptwoscrewsandliftup
toremovethecablechasecoverfromtheterminalbase.
NowyouhavecompleteaccesstotheconnectionportsonthePOS
terminal.
RemoveCableRetainers
YourEverServ6000POSterminalhastwocableretainersthatsecure
yourcablesinplacestokeepthemneatandorganizedandprevent
unintentionaldisconnection.
8.Locatethebottomcableretainerandloosenonescrewtoloosen
thecableretainerandswingitaside.
9.Locatethetopcableretainerandloosenonescrewtoloosenthe
cableretainerandswingitaside.
ConnectPeripheralstoPOSTerminal
ConnectyourperipheralstoyourPOSterminal.Refertothe“Main
CableWell”sectiononpage1.
Whenyouhavefinished,usethecableretainerstosecureandorganize
yourcables.
10.Gatherthecablesinonehandandreplacethetopcableretainer,
securingthecablesneatlyinplace.Ensurethecablesarenotkinkedor
stressed.
11.Arrangethecablessotheyareinarowonthecablechaseand
replacethebottomcableretainer.
12.Replacethecablechasecoverbyaligningthetabswiththeslots
andtighteningthethumbscrewsonthebaseofthePOS.
13.Replacethemaincablewellcoverbyaligningthetabswiththe
slotsandtighteningtheknurledthumbscrewsonthecover.
14.StandthePOSuprightonitsbase.
ConnectAdditionalPeripheralstoPOS
IfyourPOSterminalhastheoptionalexpansionboard,F7820,connect
additionalperipheralsasnecessary.Referto“OptionalExpansion
Board(F7820)”onpage1ofthisguide.
ReplacetheSideCableWellCovers
15.Replacethesidecablewellcoversandsecuretheminplaceby
tighteningthethumbscrewsonthebaseoftheterminal.Youmay
needtoresttheterminalonitsbacktodothis.
PoweronthePOSEquipment
16.PoweronthePOSterminal.Thepowerbuttonislocatedonthe
bottomleftsideofthetopcover.
17.Poweronyourperipherals.
ConnectingUSBDevices
ThePAREverServ6000POSTerminalhas6availableUSBPorts.
Onthemaincableconnectionpanelunderthetopcover,thereare
twostandardUSBports:
IfyourPOSterminalhastheoptionalexpansionboard,F7820,onthe
leftsidecableconnectionpanel,therearetwostandardUSBports.On
therightsidecableconnectionpanel,therearetwopoweredUSB
ports:
StandardUSBcablescanbepluggedintothesepoweredUSBPorts:
RemoveCable
ChaseCover
Ensurecablesareflat
anduntwisted
2Standard
USBPorts
12VPowered
24VPowered
USBPort