Ensure any unused wires are safely terminated.
ACU terminal
+12V
Red LED
Amber LED
Green LED
Wiegand D0
Wiegand D1
NOT USED
0V
ZKteco
NOT USED
NOT USED
NOT USED
NOT USED
WD0
WD1
GND
NOT USED
Setting up modes: Token + Temp & Face + Temp
Net2 ACU Settings
ZKTeco SpeedFace Required Settings
Connecting the reader to a Net2 Plus controller
There are two other main modes of operation; Token + Temp and Face + Temp. In both cases the Speed-
Face reader should be wired to the Net2 plus as shown in the diagram below:
Congure the reader port settings for the ACU the reader has been connected to as shown in the
screenshot below:
Once you have wired up the reader and setup the reader in Net2, the SPEEDFACE reader will need to
be congured. Using the instructions provided with the reader, update the following settings:
• Authentication type - should be set in the menu, select your desired operating mode (Temper
ature is activated in another menu) Access Control->Access Control Options->”Verication
Mode”
• Temp settings - can be changed in the Temp menu. System->Detection Management->”Tem
perature over the range; access denied”
• Mask settings: System->Detection Management->”Enable mask detection” and “Deny access
without mask”
*Users must be enrolled on both the SpeedFace reader, and in Net2. Additional users will need to be
added separately in each system.
2