Paxton BLU Master Controller User manual

Master Controller Installation Guide
Ins-60005-GD-US

2
The following warnings and instructions MUST be adhered to. Read the instructions before installing and powering the equipment. Keep the instructions in a safe place for future
reference.
RECEIVING INSPECTION - Remove any traces of packing material from the unit as such debris may create a re or shock hazard. Unpack the unit with care and inspect for transit
damage. If damage is suspected, the unit must not be used or tested, but you should immediately contact Paxton technical support to assist in troubleshooting or to provide return
authorization. INSTALLATION - Only qualied and trained personnel, familiar with this type of product and who fully understand these instructions should install, connect or test
this equipment.

3
12
4
3
Mounting This housing should be xed to the surface with suitable fasteners; screws and wall plugs
are provided for this in the tting kit. Also provided are cable ties to secure the cabling and
a smaller securing screw for the lid.

4
Power Supply
General purpose inputs (contact closure)
and outputs (12V, 0.25A max)
GSM/GPRS modem connection
Exit button 1
(push to make) †
Door contact 1
Fail secure lock *
* For a fail safe lock (maglock), wire 12V-24V
to the ‘N.C.’ terminal instead of ‘N.O.’
† Repeat the Exit button connections
for door 2 if a second door is required
Diode
Door 1 Reader/Keypad
Door 2 Reader/Keypad
To Expansion controller
(Use shielded data cable,
Belden 9841 single pair, or
technical equivalent)
TCP/IP Ethernet connection
(Use Cat5 or Cat6 cable)
Tamper switch
(cabinet)

5
Power Supply
General purpose inputs (contact closure)
and outputs (12V, 0.25A max)
GSM/GPRS modem connection
Exit button 1
(push to make) †
Door contact 1
Fail secure lock *
* For a fail safe lock (maglock), wire 12V-24V
to the ‘N.C.’ terminal instead of ‘N.O.’
† Repeat the Exit button connections
for door 2 if a second door is required
Diode
Door 1 Reader/Keypad
Door 2 Reader/Keypad
To Expansion controller
(Use shielded data cable,
Belden 9841 single pair, or
technical equivalent)
TCP/IP Ethernet connection
(Use Cat5 or Cat6 cable)
Tamper switch
(cabinet)
Overview
LED diagnostics
The Paxton BLU Master Controller connects to the cloud based server through a TCP/IP Ethernet port or through the optional GSM/GPRS modem.
If you are running a DHCP server on your network then you do not need to congure the communication settings as a static IP address is not
required. The section below (Conguring the Paxton BLU Control Master unit) explains how to congure the unit if you do not have a DHCP server.
The GSM/GPRS modem does not require any user conguration.
To add additional doors to the site, up to a maximum of 50, you should purchase the Paxton BLU Expansion Controllers. These connect via the
self-terminating RS485 bus connection, no additional termination is required. Larger sites are accommodated by using multiple master units that
can be logically grouped in the software.
Please be aware that if you dont have an Ethernet connnection then by default the unit will attempt to connect through the GSM network.
This would require the purchase of a Paxton BLU Modem and activation license.
• Contact 1 (Orange) Door 1 contact closed
• Contact 2 (Orange) Door 2 contact closed
• RS485-OUT (Orange) Unit receiving data
• OK (Green) Flashing on and o to indicate trying to connect (0.5 secs)
• OK (Green) Flashing to indicate unit is connected(fast ash once per second)
• OK (Green) On for 3 secs then ashing, see diagnostics below.
• Server connected (Orange) The TCP/IP interface is connected
• Server link (Green/Orange) 10/100 Mbits/sec
• IN-1 to IN-4 (Orange) Activity on inputs IN-1 to IN-4
LED diagnostics - OK LED on for 3 seconds then 0.5 second ash indicates -
• Ok - 1 Flash Error 1 Internal controller fault (reset failed) contact Paxton Inc
• Ok - 2 ashes Error 2 Not currently used
• Ok - 3 ashes Error 3 Not currently used
• Ok - 4 ashes Error 4 GSM service connection cannot be found
• Ok - 5 ashes Error 5 GSM modem not connected
• Ok - 6 ashes Error 6 Not currently used

6
Connecting the Paxton BLU Master Controller
Wire the components to the Paxton BLU Master Controller as shown, using the diagram on page 4.
Power up the unit and wait for the OK LED heartbeat. If there is a fault with the installation or the unit then the diagnostic LEDs (see above) may
well show the fault type enabling you to report or rectify the problem before proceeding.
To conrm relay activation for the locking hardware, press the exit button or in the absence of an exit button, place a test jumper between the 0v
and exit terminals. Once the exit button is pressed or the jumper temporarily placed, the lock should release.
When using Paxton readers, the reader’s default indication has all the LEDs on. Access granted is denoted with a single ashing Green LED. Access
Denied is a single ashing Red LED. The green reader LED should ash when the exit button is pressed.
Conguring the Paxton BLU Master Controller
Before starting the conguration process, be sure that you have purchased the Master Controller License (838-540-US) and had the master
controller activated. To purchase this, please contact Paxton at 877.438.7298, option #7, note that you will need the serial number and activation
code listed on the front of the master controller.
The Paxton BLU Control Master unit requires conguration and initialization before use. To do this will require a Windows PC or laptop
with USB ports and internet access, or having the proper installer tool previously installed.
Install the Installer Tool software. This is available to download from the Help page of your installer login to Paxton BLU. You may wish
to create a desktop shortcut for this application.
Tip: Always ensure you have downloaded the latest version of the Installer tool to ensure you have the most recent version of rmware.
The latest version is bundled with the Installer Tool application.
Remove the power from the unit.
If your master controller is housed in a metal enclosure, you will need to remove the PCB from the plastic mounting bracket in order
to attach the interface adapter. Please do so carefully and be sure that the PCB is fully secured to the bracket upon completion of the
rmware update process.
CAUTION: Make sure the adapter is
plugged into both rows of the header
on the PCB before you proceed (see
image on right for proper placement
and connection).

7
Power up the controller with the installer tool adapter connected. Note your PC or laptop may need to download a device driver for this
device so allow this to complete rst. Now run the Installer Tool by double clicking the Installer Tool application.
Click on settings and select the COM port that your PC or laptop has assigned to this device. The drop down box lists all available COM
ports.
Tip: You can conrm the COM port assigned by your computer by navigating to the Windows ‘Device Manager’ and then selecting
‘Ports (COM & LPT)’
Now click on ’View Device Details’and then on the‘Get Details’ button. Follow the instruction by power cycling the
Master unit so that it goes into its bootloader and provides the required details.
Tip: You can power cycle the Master unit by removing and replacing the two pin power plug at the top right of the controller (a two
pin plug) marked 12V-24V and 0V.
You will not need to do anything with this information at this point. Make a note of how this information is obtained as it will be
needed should the wiring label be lost or misplaced. This information may be required by Paxton technical support for diagnostics
and troubleshooting.

8
Firmware Update
Communication Settings
It is important to update the rmware to the latest available version before proceeding further.
Select the ‘Update Firmware’button.
Power cycle the Master unit as described above to start the rmware update.
If you recieve an ‘access to the port XX is denied’ error message from Windows, click the OK button and power cycle the unit again to attempt to
re-start the rmware update.The rmware update will take a minute, once the green bar has progressed to ll the space, the update is complete.
You can check the version of rmware installed using the ‘View Device Detail’ option described in the previous section.
Tip: It is useful to know which version of rmware is installed whenever you contact Technical Support.
Please store the adapter in a safe place. You will need this for your expansion controllers along with any future upgrades to this master
controller.
If you are updating rmware on a unit already in use you will need to re-instate this controller in the software following the rmware update.
The ‘Communication Settings’button displays a number of settings with default values (see below). You can query the exisiting settings and edit
those if you wish.
You may select the Default Communication Method from the drop down list.
The default setting is ‘Auto’ meaning that the controller will attempt to use the TCP/IP Ethernet connection as long as one is available. If the
Ethernet connection is not present, or fails conguration, the controller will automatically use the GSM/GPRS modem.
Note that cellular charges may apply and use of this will require the purchase of the Paxton BLU Modem and license. You may also choose to set
the communication method to GSM or Ethernet only, depending on the customer and site requirements.
You may manually congure your Ethernet connection on a static IP address should you not have a DHCP server available.
Please note that the Master controller does not require a xed or static IP address to communicate and can utilize DHCP addressing. If you have
DHCP you do not need to set any of the Ethernet settings. Should you not have a DHCP server you will need to contact the site IT Manager to
obtain an IP address and other connection information.

9
Once you have completed the setup then press‘Send to Device’and follow the power cycle instruction. You should now close this application, turn
o the power to the Master unit and remove the adapater and USB cable.
Tip: Remember to always download the latest version of the installer tool to ensure you have the most recent version of rmware to install.
You have now completed the initial conguration of the master controller, power cycle the unit and log into your Paxton BLU account
(my.paxton-blu.com), go to Help and select Quick Start Guide to assist you in setting up the controller in your customer and site.
n
Electrical
Voltage 11V DC 24V DC (+20%)
PCB Current (depending on activity) 200 mA
Relay switchable voltage 24V DC (+20%)
Relay switchable current 4A
General purpose outputs OUT-1, OUT-2 0.25 A @ 12V DC
Combined reader port output current 500 mA
Specications
Min Max

10
Environment
Operating temperature - Battery limits 0°C - 32 °F 55°C -131 °F
Weatherproof No
Communication
Ethernet network speed 10 Mbits/sec 100 Mbits/sec
Ethernet bandwidth requirement 200 kbits/sec
DHCP support Yes
RS485 network speed 115.2 kbits/sec
RS845 Dataline 3280.84 ft
(100m) between
controllers
Features
Number of Cards 100,000
Number of PINs 100,000
Access levels (per customer) 1000
Time zones 1 sec 512
Door open time 99,999 sec
Data lines per system Unlimited
Doors per controller 2
Reader ports per controller 2
Readers/ Keypads per port 2
Controllers per data line 25 (50 doors)
Data retention after total power loss 7 days
Events stored in controller with no server connection 200,000
Dimensions
Controller 4 1/64 inch (W) 4 3/4 inch (H) 1 inch (D)
Cabinet 9 1/4 inch (W) 12 1/2 inch (H) 3 1/8 inch (D)
Min Max

11

18/08/2017© Paxton Ltd
Ins-60005-GD-US
Managed access controller
Master 838-501-US/838-601-US
1.0.3
Made in the UK
Table of contents
Other Paxton Control Unit manuals