Transmission power<0.2mW
mm
mm
PD-MV1012-A Microwave Sensor Instruction
Specifications
Utilizing field and introduction
Sensor information
Working temperature: -15°C~+70°C
Detection angle: 360°
Detection range: 2-10m (radii.) (adjustable)
Time setting: 8sec to 12min (adjustable)
Light-ontrol: 2-2000LUX (adjustable)
Power consumption: approx.0.5W
Installation sit: ceiling mounting
HF system: 5.8GHz CW electric wave,ISM band
Power source: 100-240VAC
Power frequency: 50/60Hz
Rated load:
600W/5A,Max,tungsten(cosφ=1)(100-130VAC)
150W/2.5A,Max,fluorescent(cosφ=0.5)(100-130VAC)
Transmission power: <0.2mW
1200W/5A,Max,tungsten(cosφ=1)(220-240VAC)
300W/2.5A,Max,fluorescent(cosφ=0.5)(220-240VAC)
Note: the high-frequency output of this sensor is
<0.2mW- that is just one 5000 of the transmission
power of a mobile phone or the output of a
microwave oven.
th
PD-MV1012-A is a motion sensor whose detection range is 360° and working frequency is 5.8G. It adopts a
microwave sensor (HFoutput<0.2mW), so it is of more stable and safer performance than PIR motion sensor,
it can also be used where the ambient temperature is about
-15°C~+70°C.
H
L
L
1
2
3
4
5
6
7
8
9
10
11
12
0 11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414
Detection rang: 6M max (Height of installation2M) Detection rang: 7-8M max (Height of installation4M)
Detection rang: 6-8M max (Height of installation8M)
Detection rang: 6-7M max (Height of installation6M)
Detection rang: 6-7M max (Height of installation10M)
Ground
360º
Sensing angle adjustment range
Warning!
When you are drilling ,please make sure
you wear glasses and dust masks to
prevent the dust fly into the nose and throat
causing unnecessary trouble
fig.6
fig.5
base holes
fig.1 fig.2 fig.3
fig.4
4、Put the power wire and load wire through the base holes (see fig.5);
5、
Cover cover into buckle
(see fig.6);
1、Through the buckle under cover(see fig.1)(fig2)
2、Hold base against the Ceiling and mark drill holes,
paying attention to any existing wiring in the Ceiling(fig.3);
3、Drill the holes, insert wall plugs (6mm dia.);(see fig.4);
Knob setting
Installation
LUX
SENS TIME
AC Power
L
L’
N
If you want PD-MV1012-A to detect small zone, you can just adjust the sense knob SENS to the range that you
need (You may need to adjust some times untill you think it is suitable).If you want that the light can be turned
on when the circumstance luminance is under some value, you can just adjust the knob LUX (The working
luminance knob) to select the luminance value (You may need to adjust some times untill you think it is
suitable).
Detection range setting(sensitivity)
Time setting
Detection range is the term used to describe the radii of the roughly circle casting on
the ground when installed at the height of 2.5 m. To turn the knob fully anti-clockwise
is the minimum range (2m), fully clockwise is the maximum (10m).
The light can be set to stay ON for any period of time between approx. 8sec(turn fully
anticlockwise) and a maximum of 12min(turn fully clockwise). Any movement
detected before this time elapse will re-start the timer. It is recommended to select
the shortest time for adjusting the detection zone and for performing the walk test.
NOTE: the above detection distance is gained in the case of a person who is between
1.6m~1.7m tall with middle figure and moves at a speed of 1.0~1.5m/sec. If person’s stature,
figure and moving speed change, the detection distance will also change.
NOTE: When the light be auto off, it will take 1 second before the sensor is ready to detect
another movement, that is, only signal detected 1 seconds later can the light be auto-on.
Light-control setting
It can be defined in the range of 2~2000 LUX. To turn the knob fully anti-clockwise is
about 2 lux, fully clockwise is about 2000 lux. When adjusting the detection zone and
performing the walk test in daylight, you should turn the knob fully clockwise.
NOTE: please don’t adjust the three functional buttons to excess. That is because the three
functional buttons were connected to the components directly, there is a small stopper in
each of the three components, when you adjust the buttons from start to end, the excessive
turn will damage the stopper,and lead to the 360°non-stop turn around. Theadjust range
limit is 270°, please do pay attention to this.
2-10m
8sec-12min
2-2000LUX
ATTENTION:When use this product, please adjust the sensitivity to an appropriate position
you need, please do not adjust the sensitivity to maximum, to avoid the product does not
work normally caused by wrong motion.Because the sensitivity is too high easily detect the
wrong motion by wind blowing leaves & curtains, small animals, and the wrong motion by
interference of power grid & electrical equipment. All those lead the product does not work
normally !
When the product does not work normally, please try to lower the sensitivity appropriately,
and then test it.
Warning!
1、Being installed on the rocking object will lead to error reaction.
2、The shaking curtain blown by wind will lead to error reaction. Please select the suitable place to install.
3、Being installed where the traffic is busy will lead to error reaction.
4、The sparks produced by some equipment nearby will lead to error reaction.
The following situations will lead to error reaction.
Fault and the solution
The load fails to work.
Light-illumination is set incorrectly.Adjust the setting of the load.
Change the load.
Turn the power on.
Check the settings of the
detection area.
Re-adjust the installation place.
Check the settings of the
detection area.
Check the settings of the
detection area.
The load is broken.
The power is off.
There is a continuous signal in the region of the detection.
Moving signal is detected by the sensor (movement
behind the wall, the movement of small objects, etc.)
The lamp isn't installed well so that sensor fails to
detect reliable signals.
The motion speed is too fast or the defined detection
area is too small.
Fault Failure cause Solution
The load works all the time.
The load works when there is
no motion signal detected.
The load fails to work when
there is motion signal detected.
● Please confirm with prefessional installation.
● For safety purposes, please cut off power before installation and removal operations.
● Any losses caused by improper operation,the manufacturer does not undertake any
responsibility.
Warning!
We are committed to promoting the product quality and reliability, however, all the electronic
components have certain probabilities to become ineffective, which will cause some
troubles.When designing, we have paid attention to redundant designs and adopted safety
quota to avoid any troubles.
This instruction, without our permission, should not be copied for any other purposes.

Other pdlux Security Sensor manuals

pdlux PD-MV1017B User manual

pdlux

pdlux PD-MV1017B User manual

pdlux PD-MV1017A User manual

pdlux

pdlux PD-MV1017A User manual

pdlux PD-PIR102-Z User manual

pdlux

pdlux PD-PIR102-Z User manual

pdlux PD-MV1019 User manual

pdlux

pdlux PD-MV1019 User manual

pdlux PD-MV1005-Z User manual

pdlux

pdlux PD-MV1005-Z User manual

pdlux PD-MV1007A User manual

pdlux

pdlux PD-MV1007A User manual

pdlux 30N2 User manual

pdlux

pdlux 30N2 User manual

pdlux PD-PIR101-Z User manual

pdlux

pdlux PD-PIR101-Z User manual

pdlux PD-MV1018A User manual

pdlux

pdlux PD-MV1018A User manual

pdlux PD-MV1007 User manual

pdlux

pdlux PD-MV1007 User manual

Popular Security Sensor manuals by other brands

ADEMCO 4275EX-SN installation instructions

ADEMCO

ADEMCO 4275EX-SN installation instructions

DOL 104 0.5-3 V Technical user guide

DOL

DOL 104 0.5-3 V Technical user guide

STI Exit Stopper STI-6400 Series installation instructions

STI

STI Exit Stopper STI-6400 Series installation instructions

INPRO 51SS installation instructions

INPRO

INPRO 51SS installation instructions

Steinberg Systems SBS-PM2.5 user manual

Steinberg Systems

Steinberg Systems SBS-PM2.5 user manual

System Sensor ED-TI Installation and maintenance instructions

System Sensor

System Sensor ED-TI Installation and maintenance instructions

Chalmor PIR/CM Product data

Chalmor

Chalmor PIR/CM Product data

heightec TowerPack WK34 User instructions

heightec

heightec TowerPack WK34 User instructions

Lince 1883 ZENITH DT/E Installation, programming, and operating manual

Lince

Lince 1883 ZENITH DT/E Installation, programming, and operating manual

Bresser 7009997 instruction manual

Bresser

Bresser 7009997 instruction manual

Elkron MP3040 user manual

Elkron

Elkron MP3040 user manual

Roland R1000 series E20 user manual

Roland

Roland R1000 series E20 user manual

Mace 80200 manual

Mace

Mace 80200 manual

Silverline 466238 manual

Silverline

Silverline 466238 manual

Stahl INTRINSPAK 9001 Series Product information

Stahl

Stahl INTRINSPAK 9001 Series Product information

Thytronic SME2 manual

Thytronic

Thytronic SME2 manual

LUXOMAT PD3-2C-FC Micro Installation and operating instruction

LUXOMAT

LUXOMAT PD3-2C-FC Micro Installation and operating instruction

THORLABS PDA20C2 quick reference

THORLABS

THORLABS PDA20C2 quick reference

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.