pdlux PD-MV1007 User manual

NOTE:
the high-frequency output
of this sensor is <0.2mW- that is just
one 5000 of the transmission power
of a mobile phone or the output of a
microwave oven.
Specifications
Utilizing field and introduction
Sensor information
Transmission power<0.2mW
Height of installation2.5~3.5M
PD-MV1007 is a moving object sensor that can detect range of 360°and it’s working frequency is 5.8G.The
advantage of this product is stable working state (stable working temperature: -15°C~+70°C), PD-MV1007
adopts a microwave sensor(high-frequency output<0.2mW),so that it is safe and performs better than infrared
sensor.
2.5-3.5m
Appearance and size
th
Power source: 90-240V/AC
Power frequency: 50/60Hz
Transmission power: <0.2mW
Rated load: Detection angle: 360°
Detection range: 2m-5m-8m-10m (radii.) (adjustable)
Time setting: 6sec-1min-3min-5min-10min-15min (adjustable)
Light-control: <10LUX-100LUX-300LUX-2000LUX (adjustable)
Power consumption: approx.0.5W
Working temperature: -15°C~+70°C
1200W/5A,Max,tungsten(cosφ=1)(220-240V/AC)
300W/2.5A,Max,fluorescent(cosφ=0.5)(220-240V/AC)
600W/5A,Max,tungsten(cosφ=1)(100-130V/AC)
150W/2.5A,Max,fluorescent(cosφ=0.5)(100-130V/AC)
Installation sit: indoors, ceiling mounting
HF system: 5.8GHz CW electric wave,ISM band
360º
Min:2mMin:2m Max:10m
Max:10m
Sensing angle adjustment rangeSensing distance adjustment range
Microwave Sensor
PD-MV1007 instruction
www.pdlux.com Tel: 86-574-83008608

Warning!
AC Power
Utilized in ceiling light
This product can be utilized in more fields than the above examples.
You can also install a PD-MV1007 in the ceiling directly to control an aisle. There is no problem.
Non-metal material
The product can not work normally if there is
metal material behind the Installed place.
Electrical load
Security alarming system
The intelligent lighting system
It can be installed inside of product that is made of glass and plastic because that these materials make little
effect to microwave. Connect the product as shows below; you can change a common light to an automatic
light.
L
L’
N
Connect N, L with power;
Connect N, L’ with load.
Parameter setting
Shown as chart below:By setting the S1, S2 ,S3 ,S4,S5 to set the delay time of products,by setting S6,S7 to
set the detection range of products, by setting the S8,S9,S10 to set the light-control of products.
TIME:S1,S2,S3,S4,S5 SENS:S6,S7 LUX:S8,S9,S10
This product will be faithfully waiting for you. It will turn on the light automatically when you pass by, and turn
off the light automatically when you leave off. You can set the closing delay time to meet your needs. For
example, you may adjust the TIME sliding controller to select the delay time 6sec~15min when you think you
will come back in 15mins. The TIME sliding controller is as follow (Keep away from the detecting zone after
adjusting the testing time or that the detecting time will be inaccurate when any moving object is detected again
by the product).
when the sensor is installed inside the ceiling
floor,the sensitivity to light will be invalid.
1
0
Microwave Sensor
PD-MV1007 instruction
www.pdlux.com Tel: 86-574-83008608

If you want PD-MV1007 to detect small zone, you can just adjust the sense sliding controller SENS to the
range that you need (You may need to adjust some times untill you think it is suitable).If you want that the light
can be turned on when the circumstance luminance is under some value, you can just adjust the sliding
controller LUX (The working luminance sliding controller) to select the luminance value (You may need to
adjust some times untill you think it is suitable).
S1 S2 S3 S4 S5 Time setting
00000 15min
10000 10min
010005min
001003min
000101min
000016sec
S6 S7 Detection range
1110m
108m
0
0 0
15m
2m
Time setting
Detection range setting (sensitivity)
The light can be set to stay ON for any period of time between approx. 6sec and a maximum of 15min. Any
movement detected before this time elapse will re-start the timer. It is recommended to select the shortest time
for adjusting the detection zone and for performing the walk test.Pull switch to the ON position as "1", pull
switch to the OFF position as "0”, switch location and detection range of the corresponding table is as follows:
Detection range is the term used to describe the radii of the more or less circular detection zone produced on
the ground after mounting the sensor light at a height of 2.5m, pull switch to the ON position as "1", pull switch
to the OFF position as "0”, switch location and detection range of the corresponding table is as follows:
TIME:S1,S2,S3,S4,S5
SENS:S6,S7
ATTENTION:When use this product, please adjust the sensitivity to an appropriate position
you need, please do not adjust the sensitivity to maximum, to avoid the product does not
work normally caused by wrong motion.Because the sensitivity is too high easily detect the
wrong motion by wind blowing leaves & curtains, small animals, and the wrong motion by
interference of power grid & electrical equipment. All those lead the product does not work
normally !
When the product does not work normally, please try to lower the sensitivity appropriately,
and then test it.
1
0
1
0
Microwave Sensor
PD-MV1007 instruction
www.pdlux.com Tel: 86-574-83008608
Solutions of prevent the power network pulse interference the products:
Due to the difference of regional interference power network, the pulse of interference is
uncertain,so the user are not suggested to adjust the sensitive to the maxium when using.
Suggestion:Please install and adjust the sensitive in the appropriate distance using,do not
set the maxium sensitivity to prevent misoperation.

In shell chassis Cover into buckle
PD-MV1007-A
If you want use PD-MV1007 as a single, you can also order the shell which is especially manufactured for the
product to be installed in, or you can select the product PD-MV10070-A directly. The protection grade of
PD-MV1007-A is IP55, so PD-MV1007-A is better than PD-MV1007 with the higher water proof quality.
Troubleshooting
Malfunction Cause Remedy
·wrong light-control setting selected ·Adjust setting
·load faulty ·Change load
The load will not work
·mains switch OFF ·Switch ON
The load work always ·continuous movement in the detection
zone
·Check zone setting
·the sensor not mounted for detecting
movement reliably
·Securely mount enclosure
The load work without any
identifiable movement
·movement occurred, but not identified
by the sensor(movement behind wall,
movement of a small object in immediate
lamp vicinity etc.)
·Check zone setting
The load will not work despite
movement
·rapid movements are being suppressed
to minimize malfunctioning or the
detection zone you have set is too small
·Check zone setting
Application places
Concise modeling ,and the shell
increases the IP CODE.
(According to customer's need selected.)
Microwave Sensor
PD-MV1007 instruction
www.pdlux.com Tel: 86-574-83008608
S8 S9 S10 Light-control
0 0 1 2000LUX
010300LUX
100100LUX
0 0 0 <10LUX
Light-control setting
The chosen light response threshold can be infinitely from approx. 10-2000lux, pull switch to the ON position
as "1", pull switch to the OFF position as "0”, switch location and detection range of the corresponding table is
as follows:
LUX:S8,S9,S10
1
0

Microwave Sensor
PD-MV1007 instruction
www.pdlux.com Tel: 86-574-83008608
The detection distance may multiply for the reflection on microwave electromagnetic field by the metal or glass materials.
Thus, lower the sensitivity to reach the appropriate detection distance. Never turn the SENS knob to the maximum value
to avoid error detection. Also the surrounding environment will lead to error action, e.g. the automobiles passing by or the
wandering objects caused by the wind. Products should be installed more than 4 meters one from the other, otherwise the
interference among them will cause error action.
We are committed to promoting the product quality and reliability, however, all the electronic components have certain
probabilities to become ineffective, which will cause some troubles. When designing, we have paid attention to redundant
designs and adopted safety quota to avoid any troubles.
This instruction, without our permission, should not be copied for any other purposes.
It is mainly for the adjustment of the delay time from the moment the signal detected and light auto-on till the light auto-off.
You can define the delay time to your practical need. But you’d better lower the delay time for the sake of energy saving,
since the microwave sensor has the function of continuous sensing, that is, any movement detected before the delay time
elapses will re-start the timer and the light will keep on only if there is human in the detection range.
Add: 17F,Commerce Building of NingBo,
No 588, South Tiantong Rode,Yinzhou District,Ningbo,China
Tel: 86-574-83008608(20 lines) Fax: 86-574-83008609
3. Being installed in the place where the traffic is busy will lead to misoperation.
4. It will lead to misoperation when there are sparks produced by some equipment nearby.
Warning!
1. Being installed in the rocking object will lead to misoperation.
2. The shaking curtain which is blown by wind will lead to misoperation, please select the suitable installed place.
The following situation will lead to misoperation
Table of contents
Other pdlux Security Sensor manuals

pdlux
pdlux PD-MV1017A User manual

pdlux
pdlux PD-MV1017B User manual

pdlux
pdlux PD-PIR102-Z User manual

pdlux
pdlux PD-MV1007A User manual

pdlux
pdlux 30N2 User manual

pdlux
pdlux PD-MV1005-Z User manual

pdlux
pdlux PD-MV1012-A User manual

pdlux
pdlux PD-PIR101-Z User manual

pdlux
pdlux PD-MV1019 User manual

pdlux
pdlux PD-MV1018A User manual