PDU16-6UK
USERS GUIDE
20A AC STAGE & TRUSS MOUNT PLUG BOARD
For safety it m st be remembered when sing the LINK o tp t that the
combined load of the 'Daisy Chained' nits sho ld not exceed 20A.
POWER INPUT SIDE
LINK OUTPUT SIDE
RED Neon Indicator
If the switch is in the reset position
and lit - this shows there should
be AC power to the board.
Should these Not be Lit then -
1st check the power is connected &
none of the outputs are being
overload
ed
Neutrik 20A 240V lue
PowerCON input connector
For the full 20A usage the
right cable & supply
source should be used
Fitting a 13A pl g will
de-rate this board
16A Trip Switch
for the 6 UK sockets
in the event of overload
this will cut the power
LINK OUTPUT is a grey 20A
PowerCON output connector
and is directly coupled
to the Power Input Socket
not via the breaker circ it
2 + PDU16-6UK can linked via the though link outputs to give 12 or more remote
outputs with a TOTAL maxim m working load of 20A
PLEASE NOTE THE MAIN INPUT SOCKET OF ANY CHAIN IS RATED
AT 20 AMPS
These boards are designed for indoor se and sho ld
not be sed in damp or wet conditions
Compliance All components used in this unit conform to current RoHS, CE & UL certification BS1363A, BS136 , SASO 03
(EMI:EN550 (CISPR ) Class B; EN61000-3- ,3 EMS:EN61000-4- ,3,4,5,6,8,11; Light industry level, criteria A)
Designed & Made in the UK by Penn Elcom Ltd
9-10 Parsons Road, Parsons Industrial Estate, Washington Tyne & Wear, NE37 1H , UK
0191 416 1717 or www.penn-elcom.com
M10 fixing for G Clamp
mounting on bars or
trussing
Slots for Velcro ties or
cable tie mounting
Declaration of Conformity
The Manufacturer of the Products covered by this Declaration is
Made in the UK by Penn Elcom
9-10 Parsons Road, Parsons Industrial Estate,
Washington yne & Wear, NE37 1HB, UK
The Directives covered by this Declaration
89/336/EEC Electromagnetic Compatibility directive, as amended
73/23/EEC Low Voltage E uipment directive, amended by 93/68/EEC
The Products Covered by this Declaration
PDU16-6UK
20A MAX Stage & Truss Mount Professional K Plug Board
sable Voltage 110V-250 VAC 50-60Hz - Max Output Power: 5000W - Max Current: 20A
Input= Neutrik 20A PowerCON connector with a 16A Illuminated Breaker Switch.
Through Link Output = 20A Grey PowerCON connector directly coupled main input socket
Outputs = 6 K type G sockets BS 1363/IEC 60083
with a Maximum Combined Load 16A through a 16A Breaker Switch
The Basis on which Conformity is being Declared
The manufacturer hereby declares under his sole responsibility that the products identified above comply
with the protection re uirements of the EMC directive and with the principal elements of the safety
objectives of the Low Voltage E uipment directive, and that the following standards have been applied:
All components used in this conform to current RoHS, CE & UL certification
(EMI:EN55022 CISPR22) Class B; EN61000-3-2,3 EMS:EN61000-4-2,3,4,5,6,8,11; Light industry level, criteria A)
The technical documentation re uired to demonstrate that the products meet the re uirements of the Low Voltage
E uipment directive has been compiled and is available for inspection by the relevant enforcement authorities.
The CE mark was first applied in: 2018
Signed:
Authority: Technical Director (M Inst SCE)
Date: 01/10/2018
Attention!
The attention of the specifier, purchaser, installer, or user is drawn to special measures and limitations to use which
must be observed when these products are taken into service to maintain compliance with the above directives.
Details of these special measures and limitations to use are available on request and are also contained in the product manual.
E&OE
TRIP SWITCH APPENDIX
These products are fitted with thermal circuit breaker/power switches with indicator as a fail safe and should not be
used to determine excessive current drawer. These are not an RCD and do not function in the same way.
SERS OF THESE PD 'S SHO LD PRE-DETERMINE THE MAXIM M SAFE LOAD AS INDICATED ON THE BACK OF THE NIT.
PLEASE NOTE: An RCD is a safety switch that protects people from electrical shock; a circuit breaker protects the wiring
and electrical components attached to the unit.
In normal operation there will be peaks in the current draw and these switches allow for this, but will switch if the
overload is continuous.
Technical Specification
Calibration: Will continuously carry 100% of rating.
May trip between 101% and 134%,
(they must trip at 135% of rating within one hour at +25°C
See Chart)
Dielectric Strength: 1,500VAC (60 seconds).
Insulation Resistance: 100 megohms.
Maximum Operating Voltage: 250VAC, 50/60 Hz.
These switches have the following certification approvals:
UL 1077 , VDE 0642/EN60934, CCC & CE compliant.
Penn Elcom Ltd excepts no responsibility or liability for any equipment connected to this unit

Other Penn Elcom Power Distribution Unit manuals

Penn Elcom PDU01-14 User manual

Penn Elcom

Penn Elcom PDU01-14 User manual

Penn Elcom PDU6-UK User manual

Penn Elcom

Penn Elcom PDU6-UK User manual

Penn Elcom PDU-UK-6 User manual

Penn Elcom

Penn Elcom PDU-UK-6 User manual

Penn Elcom PDU16-10DJ User manual

Penn Elcom

Penn Elcom PDU16-10DJ User manual

Penn Elcom PDU-EU-6 User manual

Penn Elcom

Penn Elcom PDU-EU-6 User manual

Popular Power Distribution Unit manuals by other brands

Furman MP15 instruction sheet

Furman

Furman MP15 instruction sheet

Pulizzi IPC34XX-NET Series Specifications

Pulizzi

Pulizzi IPC34XX-NET Series Specifications

Woodward HighPROTEC MRU4 manual

Woodward

Woodward HighPROTEC MRU4 manual

Middle Atlantic Products Premium+ RackLink RLNK-P420 user manual

Middle Atlantic Products

Middle Atlantic Products Premium+ RackLink RLNK-P420 user manual

SMA MULTICLUSTER BOX 36 operating manual

SMA

SMA MULTICLUSTER BOX 36 operating manual

Pepperl+Fuchs GUB Series Brief instructions

Pepperl+Fuchs

Pepperl+Fuchs GUB Series Brief instructions

Alpha Technologies BDFB 8x800A Installation & operation manual

Alpha Technologies

Alpha Technologies BDFB 8x800A Installation & operation manual

Nordost QBASE QB4 Mark II instruction manual

Nordost

Nordost QBASE QB4 Mark II instruction manual

Victron energy MultiPlus-II 12/3000/120-32 manual

Victron energy

Victron energy MultiPlus-II 12/3000/120-32 manual

Middle Atlantic Products PD-DC-200 Series instruction sheet

Middle Atlantic Products

Middle Atlantic Products PD-DC-200 Series instruction sheet

e2-live iPower PS-30X instruction manual

e2-live

e2-live iPower PS-30X instruction manual

BS 20 A Series instruction manual

BS

BS 20 A Series instruction manual

Hugo Lahme VitaLight 40600250 user manual

Hugo Lahme

Hugo Lahme VitaLight 40600250 user manual

ferroamp EnergyHub XL installation manual

ferroamp

ferroamp EnergyHub XL installation manual

DINA Elektronik DNDS Kompakt Original instruction manual

DINA Elektronik

DINA Elektronik DNDS Kompakt Original instruction manual

Middle Atlantic Products MPR Series instruction sheet

Middle Atlantic Products

Middle Atlantic Products MPR Series instruction sheet

Victron energy BatteryProtect instruction manual

Victron energy

Victron energy BatteryProtect instruction manual

Baumuller BUG 3 Technical description and operations manual

Baumuller

Baumuller BUG 3 Technical description and operations manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.