WARNING Read and follow all safety warning notices and instructions in this manual
before installing this product. Failure to follow safety warnings and instructions can result in
severe injury, death, or property damage.
CAUTION When using the IntelliComm communication center with the IntelliFlo pump,
it is recommended to wire the IntelliComm power center to a ground fault circuit-interrupter
(GFCI) to protect the circuit. A green colored terminal (or a wire connector marked “G”, “GR”,
“Ground” or “Grounding”) is provided within the terminal compartment in the Power Center
transformer enclosure. To reduce risk of electric shock, connect this terminal or connector to
the grounding terminal of your electric service or supply panel with a conductor equivalent in
size to the circuit conductors supplying this equipment.
WARNING To reduce the risk of injury, installation or service should only be attempted by
DTXDOL¿HG3RRO6HUYLFH3URIHVVLRQDO
WARNING To reduce the risk of injury, do not permit children to use this product unless
they are closely supervised at all times.
CAUTION The IntelliFlo pump is for use with permanently installed pools and may also
be used with hot tubs and spas if so marked. Do not use with storable pools. A permanently
installed pool is constructed in or on the ground or in a building such that it cannot be
readily disassembled for storage. A storable pool is constructed so that it may be readily
disassembled for storage and reassembled to its original integrity.
IMPORTANT SAFETY PRECAUTIONS
Section 1
Installation Steps Summary
The recommended IntelliComm Communication Center installation steps are:
1. Review Important Safety Precautions: Review this important
information.
2. Review IntelliComm Overview: Review the product overview.
3. Installing IntelliComm: Installing the IntelliComm enclosure.
4. Connecting the AC wires to IntelliComm: Connecting AC wires to
terminal 1 and 2.
5. Connecting control input wires to IntelliComm: Connecting control input
wires to terminals 3 to 10 from source devices such as automation controllers or
heaters.
Section 2
Kit Contents
,QWHOOL&RPP&RPPXQLFDWLRQ&HQWHU
,QWHOOL&RPP,QVWDOODWLRQ*XLGHWKLVPDQXDO
Two wire RS-485 communication cable. Used to communicate to the IntelliFlo
pump from IntelliComm.