1. Marking
Inductive sensor
NBN8-18GS50-Z4L-V1-3G-3D
ATEX marking
1 II 3G Ex ec IIC T6...T1 Gc
1 II 3D Ex tc IIIC T80°C Dc
IECEx marking
Ex ec IIC T6...T1 Gc
Ex tc IIIC T80°C Dc
Pepperl+Fuchs Group
Lilienthalstraße 200, 68307 Mannheim, Germany
Internet: www.pepperl-fuchs.com
The certificate may contain several Ex markings. Depending on
the respective device, the Ex markings specified in the certificate
may be only partially valid. You will find the Ex markings valid
for the device on the respective nameplate or in this document.
2. Validity
Specific processes and instructions in this instruction manual require
special provisions to guarantee the safety of the operating personnel.
3. Target Group, Personnel
Responsibility for planning, assembly, commissioning, operation,
maintenance, and dismounting lies with the plant operator.
The personnel must be appropriately trained and qualified in order to carry
out mounting, installation, commissioning, operation, maintenance, and
dismounting of the device. The trained and qualified personnel must have
read and understood the instruction manual.
4. Reference to Further Documentation
Observe laws, standards, and directives applicable to the intended use
and the operating location. Observe Directive 1999/92/EC in relation to
hazardous areas.
The corresponding datasheets, manuals, declarations of conformity, EU-
type examination certificates, certificates, and control drawings if
applicable (see datasheet) are an integral part of this document. You can
find this information under www.pepperl-fuchs.com.
For specific device information, scan the QR code on the device or enter
the serial number in the serial number search at www.pepperl-fuchs.com.
Due to constant revisions, documentation is subject to permanent change.
Please refer only to the most up-to-date version, which can be found under
www.pepperl-fuchs.com.
5. Intended Use
The device is only approved for appropriate and intended use. Ignoring
these instructions will void any warranty and absolve the manufacturer
from any liability.
Technical data provided in the datasheet may be partly restrained by the
information given in this instruction manual.
Use the device only within the specified ambient and operating conditions.
The device is an electrical apparatus for hazardous areas.
The certificate applies only to the use of apparatus under atmospheric
conditions.
If you use the device outside atmospheric conditions, consider that the
permissible safety parameters should be reduced.
The device can be used in hazardous areas containing gas, vapor, and
mist.
The device can be used in hazardous areas containing combustible dust.
6. Improper Use
Protection of the personnel and the plant is not ensured if the device is not
used according to its intended use.
7. Mounting and Installation
Observe the installation instructions according to IEC/EN 60079-14.
Safety-relevant markings are found on the nameplate of the device or the
nameplate supplied.
Attach the nameplate supplied in the immediate vicinity of the device.
Attach the nameplate so that it is legible and indelible. Take the ambient
conditions into account.
Do not mount a damaged or polluted device.
Mount the device so that it complies with the specified degree of
protection according to IEC/EN 60529.
If you use the device in environments subject to adverse conditions, you
must protect the device accordingly.
Do not remove the warning markings.
Prevent the inside of the device from becoming contaminated when the
connector is disconnected.
7.1. Requirements for Equipment Protection Level Gc (ec)
The device is designed for use in an environment with pollution degree 3
according to IEC/EN 60664-1.
When selecting materials for accessories consider that the temperature of
the housing can rise up to 70 °C.
Provide a transient protection. Ensure that the peak value of the transient
protection does not exceed 140 % of 85 V.
7.2. Requirements for Equipment Protection Level Dc
The device is designed for use in an environment with pollution degree 3
according to IEC/EN 60664-1.
When selecting materials for accessories consider that the temperature of
the housing can rise up to 70 °C.
The maximum surface temperature of the device was determined without
a dust layer on the apparatus.
7.3. Specific Conditions of Use
Mount the device so that it complies with the specified degree of
protection according to IEC/EN 60529.
7.3.1. Requirements in Relation to Electrostatics
Information on electrostatic hazards can be found in the technical
specification IEC/TS 60079-32-1.
Do not mount the supplied nameplate in areas that can be electrostatically
charged.
You can reduce the electrostatic hazards by minimizing the generation of
static electricity. For example, you have the following options to minimize
the generation of static electricity:
• Control the environmental humidity.
• Protect the device from direct airflow.
• Ensure a continuous drain off of the electrostatic charges.
Avoid inadmissibly high electrostatic charge of the metal housing
components on the device.
Include the metal housing components in the equipotential bonding.
Avoid inadmissibly high electrostatic charge of the metal connector
components.
Include the metal connector components in the equipotential bonding.
7.3.2. Requirements to Mechanics
7.3.2.1. Requirements for Equipment Protection Level Gc (ec)
Mount the device in a way that the device is protected against mechanical
hazard.
Do not connect or disconnect the electrical connection when energized.
7.3.2.2. Requirements for Equipment Protection Level Dc
Mount the device in a way that the device is protected against mechanical
hazard.
Do not connect or disconnect the electrical connection when energized.
7.3.3. Requirements in Relation to Ultraviolet Radiation
7.3.3.1. Requirements for Equipment Protection Level Gc (ec)
Mount the device in such a way that it is protected from ultraviolet
radiation.
Install the cables and connection lines in such a way that they are
protected from ultraviolet radiation.
7.3.3.2. Requirements for Equipment Protection Level Dc
Mount the device in such a way that it is protected from ultraviolet
radiation.
Install the cables and connection lines in such a way that they are
protected from ultraviolet radiation.
7.3.4. Requirements for Connectors
7.3.4.1. Requirements for Equipment Protection Level Gc (ec)
Connect the device in compliance with the IEC/EN 60079-14
requirements.
Ensure that the device provides and maintains a degree of protection of at
least IP54 according to IEC/EN 60079-0.
Ensure that the degree of protection is not violated by the connectors.
Only use connectors that are suitably certified for the application.
Observe laws, standards, and directives applicable to the intended use
and the operating location.
Observe the interaction of the mating parts, see datasheet.
Use the 12FC4000-SK-ATEX connector from HTP S.r.l. for example.
7.3.4.2. Requirements for Equipment Protection Level Dc
Connect the device in compliance with the IEC/EN 60079-14
requirements.
Ensure that the device provides and maintains a degree of protection of at
least IP64 according to IEC/EN 60079-0.
Ensure that the degree of protection is not violated by the connectors.
Only use connectors that are suitably certified for the application.
/ 2023-09 1 / 2
Observe laws, standards, and directives applicable to the intended use
and the operating location.
Observe the interaction of the mating parts, see datasheet.
Use the 12FC4000-SK-ATEX connector from HTP S.r.l. for example.
8. Operation, Maintenance, Repair
Observe the specific conditions of use.
Safety-relevant markings are found on the nameplate of the device or the
nameplate supplied.
Do not use a damaged or polluted device.
Do not repair, modify, or manipulate the device.
Modifications are permitted only if approved in this instruction manual and
in the device-related documentation.
If there is a defect, always replace the device with an original device.
Do not remove the warning markings.
Prevent the inside of the device from becoming contaminated when the
connector is disconnected.
8.1. Requirements for Equipment Protection Level Gc (ec)
Do not exceed the maximum permissible operating voltage Ubmax.
Tolerances are not permitted.
Do not exceed the maximum permitted output current. Prevent short
circuits.
8.2. Requirements for Equipment Protection Level Dc
Do not exceed the maximum permissible operating voltage Ubmax.
Tolerances are not permitted.
Do not exceed the maximum permitted output current. Prevent short
circuits.
9. Delivery, Transport, Disposal
Check the packaging and contents for damage.
Check if you have received every item and if the items received are the
ones you ordered.
Keep the original packaging. Always store and transport the device in the
original packaging.
Store the device in a clean and dry environment. The permitted ambient
conditions must be considered, see datasheet.
The device, built-in components, packaging, and any batteries contained
within must be disposed in compliance with the applicable laws and
guidelines of the respective country.
10. National Ex approvals
KCC-EX "e": 23-AV4BO-0237X
11. Safety-Relevant Technical Data
11.1. Equipment protection level Gc (ec)
Type of protection Protection by increased safety ''ec"
CE marking 2
Certificates
ATEX certificate TÜV 20 ATEX 8523 X
ATEX marking 1 II 3G Ex ec IIC T6...T1 Gc
ATEX standards EN IEC 60079-0:2018-07, EN
60079-7:2015-12, EN IEC
60079-7/A1:2018-01
IECEx certificate IECEx TUR 21.0017X
IECEx marking Ex ec IIC T6...T1 Gc
IECEx standards IEC 60079-0:2017-12, IEC 60079-7 Edition
5.1:2017-08
Minimum ingress
protection IP 54 according to IEC/EN 60529
Minimum permissible
ambient temperature in °C Ta min: -25 °C
Maximum permissible
ambient temperature in °C Also observe the maximum permissible
ambient temperature stated in the general
technical data. Keep to the lower of the two
values.
Maximum operating voltage UBmax
Maximum load current ILmax
Minimum series resistance RV
Maximum analog output voltage UAmax
Maximum analog output current IAmax
at UBmax = 30 V, ILmax =30 mA: 62 °C
11.2. Equipment protection level Dc
Type of protection Protection by enclosure "tc"
CE marking 2
Certificates
ATEX certificate TÜV 20 ATEX 8524 X
ATEX marking 1 II 3D Ex tc IIIC T80°C Dc
ATEX standards EN IEC 60079-0:2018-07, EN
60079-31:2014-07
IECEx certificate IECEx TUR 21.0018X
IECEx marking Ex tc IIIC T80°C Dc
IECEx standards IEC 60079-0:2017-12, IEC
60079-31:2013-11
Minimum ingress
protection IP 6x according to IEC/EN 60529
Minimum permissible
ambient temperature in °C Ta min: -25 °C
Maximum permissible
ambient temperature in °C Also observe the maximum permissible
ambient temperature stated in the general
technical data. Keep to the lower of the two
values.
Maximum operating voltage UBmax
Maximum load current ILmax
Minimum series resistance RV
Maximum analog output voltage UAmax
Maximum analog output current IAmax
at UBmax = 30 V, ILmax =30 mA: 62 °C
/ 2023-09 2 / 2

Other Pepperl+Fuchs Security Sensor manuals

Pepperl+Fuchs SLCT Series User manual

Pepperl+Fuchs

Pepperl+Fuchs SLCT Series User manual

Pepperl+Fuchs OBT350-R100-2EP-IO User manual

Pepperl+Fuchs

Pepperl+Fuchs OBT350-R100-2EP-IO User manual

Pepperl+Fuchs RMS-FRW User manual

Pepperl+Fuchs

Pepperl+Fuchs RMS-FRW User manual

Pepperl+Fuchs UC2000-30GM-IUEP-IO-V15 User manual

Pepperl+Fuchs

Pepperl+Fuchs UC2000-30GM-IUEP-IO-V15 User manual

Pepperl+Fuchs RL28-55-LAS-B3B/73c User manual

Pepperl+Fuchs

Pepperl+Fuchs RL28-55-LAS-B3B/73c User manual

Pepperl+Fuchs LC10 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs LC10 Series User manual

Pepperl+Fuchs UC500-L2M-E6-T-2M User manual

Pepperl+Fuchs

Pepperl+Fuchs UC500-L2M-E6-T-2M User manual

Pepperl+Fuchs NBN15-30GS50-Z4L-V1-3G-3D User manual

Pepperl+Fuchs

Pepperl+Fuchs NBN15-30GS50-Z4L-V1-3G-3D User manual

Pepperl+Fuchs UC2000-L2-E5-V15-Y291515 User manual

Pepperl+Fuchs

Pepperl+Fuchs UC2000-L2-E5-V15-Y291515 User manual

Pepperl+Fuchs ML71-55 User manual

Pepperl+Fuchs

Pepperl+Fuchs ML71-55 User manual

Pepperl+Fuchs NBB15-30GM50-E3-V1-3G-3D User manual

Pepperl+Fuchs

Pepperl+Fuchs NBB15-30GM50-E3-V1-3G-3D User manual

Pepperl+Fuchs INX360D-F99-I2E2-V15 User manual

Pepperl+Fuchs

Pepperl+Fuchs INX360D-F99-I2E2-V15 User manual

Pepperl+Fuchs NBN15-30GS50-Z4L-V1-3G-3D User manual

Pepperl+Fuchs

Pepperl+Fuchs NBN15-30GS50-Z4L-V1-3G-3D User manual

Pepperl+Fuchs OBT300-R100-2EP-IO-L User manual

Pepperl+Fuchs

Pepperl+Fuchs OBT300-R100-2EP-IO-L User manual

Pepperl+Fuchs UC6000-30GM-IUEP-IO-V15 User manual

Pepperl+Fuchs

Pepperl+Fuchs UC6000-30GM-IUEP-IO-V15 User manual

Pepperl+Fuchs VAS/M-2A8L-KE4-6SE-EV User manual

Pepperl+Fuchs

Pepperl+Fuchs VAS/M-2A8L-KE4-6SE-EV User manual

Pepperl+Fuchs DoorScan User manual

Pepperl+Fuchs

Pepperl+Fuchs DoorScan User manual

Pepperl+Fuchs WILSEN.sonic.level WS-UCC4000 User manual

Pepperl+Fuchs

Pepperl+Fuchs WILSEN.sonic.level WS-UCC4000 User manual

Pepperl+Fuchs schmersal RSS260 AS User manual

Pepperl+Fuchs

Pepperl+Fuchs schmersal RSS260 AS User manual

Pepperl+Fuchs NBB10-30GS50-Z4L-V1-3G-3D User manual

Pepperl+Fuchs

Pepperl+Fuchs NBB10-30GS50-Z4L-V1-3G-3D User manual

Pepperl+Fuchs UC4000-30GM-IUEP-IO-V15 User manual

Pepperl+Fuchs

Pepperl+Fuchs UC4000-30GM-IUEP-IO-V15 User manual

Pepperl+Fuchs CCB10-30GS55-N1-V1 User manual

Pepperl+Fuchs

Pepperl+Fuchs CCB10-30GS55-N1-V1 User manual

Pepperl+Fuchs NBB2-12GS40-Z4L-V1-3G-3D User manual

Pepperl+Fuchs

Pepperl+Fuchs NBB2-12GS40-Z4L-V1-3G-3D User manual

Pepperl+Fuchs NCN3-F31K2 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs NCN3-F31K2 Series User manual

Popular Security Sensor manuals by other brands

Aritech RF430I4 Installation sheet

Aritech

Aritech RF430I4 Installation sheet

urmet domus 1083 manual

urmet domus

urmet domus 1083 manual

Visonic MCT-302 quick start guide

Visonic

Visonic MCT-302 quick start guide

Crewsaver CREWFIT 165 SPORT owner's manual

Crewsaver

Crewsaver CREWFIT 165 SPORT owner's manual

Southwest Microwave 310B Technical manual

Southwest Microwave

Southwest Microwave 310B Technical manual

Amprobe ULD-405 user manual

Amprobe

Amprobe ULD-405 user manual

AVS Electronics BM60HP manual

AVS Electronics

AVS Electronics BM60HP manual

Argus Security Taurus TW-DT-01/916 manual

Argus Security

Argus Security Taurus TW-DT-01/916 manual

Respirex GLS 300 A User instructions

Respirex

Respirex GLS 300 A User instructions

B.E.G. LUXOMAT PD4-S-K manual

B.E.G.

B.E.G. LUXOMAT PD4-S-K manual

Essence Care@Home Hip Fall Detector user guide

Essence

Essence Care@Home Hip Fall Detector user guide

EINHELL TC-MD 50 Original operating instructions

EINHELL

EINHELL TC-MD 50 Original operating instructions

Korno GT-1000 SERIES user manual

Korno

Korno GT-1000 SERIES user manual

Smartwares SH5-TSM-A quick start guide

Smartwares

Smartwares SH5-TSM-A quick start guide

Varian 959D Operation manual

Varian

Varian 959D Operation manual

Surface Concept Delayline DLD 8080 manual

Surface Concept

Surface Concept Delayline DLD 8080 manual

Tyco Visonic SD-304C PG2 installation instructions

Tyco

Tyco Visonic SD-304C PG2 installation instructions

DELTA DORE TYXAL DU installation guide

DELTA DORE

DELTA DORE TYXAL DU installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.