1.APPLICATION
Fig. 1. LB-85.2 electromechanical lock design
- Not included in the delivery set
*
1234
3. STANDARD DELIVERY SET
Fig. 3. LB-85.1 electromechanical lock layout
LB-85.2 is a normally-open electromechanical mortise door lock (hereinafter
– the lock), designed to be used as an operating device as a part of access
control system (hereinafter – ACS) to control light and medium office doors.
Lock features:
•the lock has a unique construction, allowing toconnect lock control cable
through the strike plate in the door frame, not through the door leaf, which
makes installation easier;
•the lock can be installed in wooden and non-metallic doors 38-50 mm thick;
•a universal lock construction enables its installation on both right-handed
and left-handed doors;
• the lock is designed for use with standard lock cylinders;
•all components of the lock and strike plate have corrosion-resistant coating;
•the lock is resistant toself-opening (for instance, as a result of a hard kick
on the door);
• the lock has low power consumption (max 2 W);
•the design of the lock does not require prev e nti v e maintenance and
lubrication from the customer for the entire period of operation;
• the lock opens when de-energized;
•when energized the lock closes automatically at shutting the door
(by a signal from ACS);
The lock with regard to resistance to environmental exposure complies with
GOST 15150-69, category NF4 (operation in premises with climate control).
Operation of the lock is allowed at ambient air temperature from +1°C to
+40°C and at relative air humidity of 75% at +15°C.
The lock has a marking in the form of label located on its housing. The label
contains product name, its serial number, the manufacture date and its main
technical specifications.
The product is packed in a carton box, protecting it from being damaged
during transportation and storage.
Box dimensions (L × W × H) ................................................... 12×20×3.6 cm
Gross weight ............................................................................... max. 0.7 kg
Lock storage is allowed indoors at ambient air temperature from -50°С to
+50°С. Storage time in closed package is 12 months.
The lock in the original package can be delivered by means of land (railway
and road), sea and air transport. It is allowed to stack the boxes while in
transit.
2. TECHNICAL SPECIFICATIONS
Attention!
Due to the continual product improvement the manufacturer
reserves the right to introduce amendments in product
design withoutpreviousnotice.
Technical parameters of the lock comply with GOST 538-2001 and
GOST 5089-2011.
DC voltage ..................................................................................... 11 – 13 V
Operational current ................................................................... 0.08 - 0.12 A
Power consumption ........................................................................ max. 2W
Type (fail-safe performance) ................................................... normally-open
Bolt throw, not less than ..................................................................... 15 mm
Centre-to-centre spacing .................................................................... 85 mm
Dimensions .......................................................................... 85×22×187 mm
Weight .......................................................................... not more than 0.5 kg
Lock type .......................................................................................... cylinder
Unauthorized access protection (UAP) .......... normal, GOST R 51241-2008
Resistance to opening .......................................... І as per GOST 5089-2011
Safety requirements .................................................. GOST R IEC 335-1-94
Electric shock protection class ...................III as per GOST R IEC 335-1-94
MTBF ............................................................. 200000 number of operations
Average lifetime ................................................................................ 8 years
Design and composition of the lock are shown in Fig. 1.
Attention!
Check the delivery set upon product receipt.
Lock ............................................................................................................. 1
Strike plate ................................................................................................... 1
Terminal block .............................................................................................. 1
Screw 2.9×13 DIN7982 ................................................................................. 2
Screw 3.9×25 DIN7982 ................................................................................ 4
Installation template ..................................................................................... 2
Certificate and operation manual ..................................................................1
Package box ................................................................................................. 1
2
1
1
24
5
67 8 9
3
11
12
13
14
10
15
1. Lever ; 2. Key; 3. Escutcheon plate fastening screw; 4. Escutcheon plate ;
5. Lever rod ; 6. Lock cylinder ; 7. Lock; 8. Screw 3.9×25;
9. Strike plate; 10. Terminal block; 11. Terminal clamps;
12. Locking mechanism roller; 13. Locking bolt; 14. Forend plate;
15. Lock cylinder fastening screw M5×50 .
* *
* *
*
87
2...3
18
4
15
R
3
44
R9
17
21
40
27
7
2 holes
12
A
A
B
B
16
3,5
x30
2 holes
38...50
80
100
24
56
15
42
3,5
x30
2 holes
27
B-B
A-A
R11
22
34
2
2
Position Unit Note
1 Control cable of the ACS controller
2Reed switch cable
A1 Power supply unit 12V; 0,5А; 6 W
A2Lock controller
A3 Terminal block
А4 Lock
S1 Reed switch
)AC61EK6P,B51-60WZB(V81–51Suppressor1DV
A2
Input
NO
C
NC
+12V
VD1
Terminal
block
Lock
magnet
S1
A1
A3 A4
Contact 1
Contact 2
1
2
Contact 1
Contact 2
1
2
ACS controller
IN
GND
Output
+U
GND
+12V
+U
GND
The universal construction provides use of standard pin-type lock cylinders, standard
EuroDIN (V DIN 18254), e.g. type 8809, 8209, 8259 produced by company ISEO
(Italy), or lock cylinders of D series by Wilco Supply (typ
e 254 – 274 – 294, 453, 454,
554). The length of lock cylinder fastening screw should not exceed 50 mm.
The lock cylinder with a set of keys, door levers with fixing e lements, reed switch,
control and reed switch cables are not included in the delivery set.
2
1
• energized lock can be released with the key.
85
145
165

567
WARRANTY CARD
Electromechanical Lock LB-85.2
Serial number
Date of manufacture « » ________________201__
Quality Control Seal
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Date of sale « » ________________201__
____________________________________
(signature, seal)
Cutting line
WARRANTY REPAIR COUPON
Electromechanical Lock LB-85.2.
Serial number
Date of manufacture « » ________________201__
Quality Control Seal
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Date of sale « » ________________201__
____________________________________
(signature, seal)
Certificate and Operation Manual
www.perco.com
5. MAINTENANCE
6. PERCo WARRANTY
PERCo
P.O. Box 87,
Saint Petersburg 194295, Russia
Tel: +7 812 321 61 72
Fax: +7 812 292 36 08
e-mail: export@perco.ru
www.perco.com
Electromechanical
Mortise Door Lock
LB 85.2-
РОСС RU.СП26.Н
ТУ 4981-049-88226999-2014
02241
6 6 7
6 6 7
4.3 Installation order
Reference numbers are given in accordance with Figure 1. Cables used at the
installation are stated in table 1.
Install the lock in the following order:
1. Unpack the lock and check the delivery set.
2. Carve out the installation template, which is included in the standard
delivery set. Make the hole marking for lock cylinder (6), lever rod (5) and,
if needed, of a location slot for lock forend plate (14) in the door leaf in
the place of lock installation using the template. Template marking
corresponds to the one in Fig. 2.
3. If necessary, select the locating pocket for the lock.
4. Carve out holes and choose the location slot for lock forend plate in
accordance with the marking.
5. Install the lock (7) in the locating pocket of the door and fasten it with two
screws 3.9×25 DIN7982 from the delivery set.
6. Mount the lock cylinder inside the lock and fix it with the screw through
the hole on the lock forend plate.
Attention!
Lock cylinder fastening screw length should not exceed 50 mm.
7. Adjust the door levers (1) with escutcheon plates (4) in accordance with
manufacturer recommendations. Tighten them with the screws with
threaded bushing (3). After the installation levers are to turn easily.
8. Check the lock operation at the opened door.
• Sink the locking mechanism roller (12) inside the lock housing to check
the mechanical unlocking. The bolt will move out of the lock housing (13).
•Turn the lock lever against stop, keeping the locking mechanism roller
sunk. The bolt will return into an initial position inside the lock housing.
Release lock handle, keeping the locking mechanism sunk. The bolt will
move out of the lock housing.
• Release the locking mechanism roller. The bolt will return into an initial
position inside the lock housing. The lock will be closed.
• Sink the locking mechanism roller inside the lock housing to check the
9. Fix the strike plate (9) on the terminal block housing (10) with two screws
2.9×13 from the delivery set.
10. Make carving in the door according to the marking (Fig. 2).
11. Lay the control cable from the ACS to the terminal block installation place
inside the door frame. Use cable №1. The cable laying method is deter-
mined by lock installer and the Customer.
12. Connect the control cable with terminal clamps (11) from the terminal
block. In order to do that, tighten cable ends into terminal clamps.
13. Mount the strike plate with the terminal block in the door frame providing
2-3 mm spacing between the strike plate and the forend when the door is
closed. The channel of the strike plate must lay symmetrical to bolt’s cross
section.
Attention!
The locking mechanism roller should not get into the channel of
the strike plate! Otherwise, at closing the door, it can get locked
with the moving roller and then it will be impossible to open the
door without damaging the lock.
14. Mount the strike plate on the door frame with two screws 3.9×25 from the
delivery set.
15. Install and connect the reed switch. Use cable №2 in table 1 for connec-
tion. Installing the reed switch ensure firm contact closure at closing the
door.
Disassembling of the lock should be made in the reverse order.
Warning!
•Do not use the lock at power supply voltage other than specified
in its technical specifications.
• Do not use the lock in operation conditions other than specified
in the following Manual.
•Do not use the lock in hostile environment with atmospheric
content of acids, bases, oils, etc.
The lock is a normally-open device, which means that de-energized lock is
unblocked. The door is opened by turning the lever (approximately at 20º).
At that the bolt moves into the lock housing, the door opens and the locking
mechanism roller automatically moves out of the lock housing. At further
door closing the locking mechanism roller is sunk into the lock housing by
the strike plate and the bolt moves out automatically locking the door.
The locking is performed by terminal block clamps’ energizing. In this case
lever turning is blocked. Energizing is operated by the ACS controller. At that
the potential operation mode should be set for lock control output. Door
opening detection is performed according to the reed switch status.
Terminal block clamps should be de-energized in order to release the lock
The door will be opened by turning the lever.
PERCo (the Manufacturer) warrants that the LB85.2 electromechanical
mortise door lock (the Product) complies with applicable statutory safety
requirements, electromagnetic compatibility provided that the instructions on
storage, installation and operation, given in the Assembly & Operation Manual
are observed.
The warranty period is 5 (five) years commencing from the date of sale.
Should there be no date of sale on the warranty card, the warranty period
shall commence from the date of manufacture.
Within the warranty period the Product is repaired free of charge at the
Manufacturer’s site.
The Warranty does not cover Products with external mechanical damages or
disassembled by the Customer.
Transportation cost to and back from the place of repair shall be borne by the
Customer.
Upon lock purchase request the date of sale stamp in the warranty certificate
and check the completeness of the delivery set as per the Manual.
In case any questions arise during the Product assembly or operation,
PERCo Company is always ready to give you necessary technical support.
4. ASSEMBLY AND INSTALLATION
4.1 General recommendations
The lock shall be installed by qualified professionals who have studied this
Manual before the installation work.
Attention!
In order to provide stable lock operation an accurate ±1,5 mm
vertical mounting of the strike platewith terminal block
regarding locking bolt is required. The lock operatesnormally
if the spacing between the forend plate and the strike plate is
2.5±1.5 mm.
4.2 Cable length
Table 1. Cables used.
№Application Max
length Type of cable An example
of cable
1ACS controller
cable 30m
Twin cable with
0.75 mm
cross-section
2HO3VV-F,
HO5VV-F 2×0.75
2Reed switch
cable 30m
Twin cable with
0.2 mm
cross-section
2
RAMCRO
SS22AF-T
2×0.22 or CQR-2
automatic unlocking. The bolt will move out of the lock housing.
• Energize lock flank contacts with 12V power supply. The lock will be
closed.
• Check several times.
Attention!
If the lock is operated as a part of access control system (ACS) it
is recommended to install voltage regulator diode BZW06-15B or
P6KE16CA, or another model with equal parameters on contact
clips (Fig. 3). The voltage regulator diode is used for maintaining
the device which sends the control signal.
Other PERCo Door Lock manuals
Popular Door Lock manuals by other brands

Henis Electronic Technology
Henis Electronic Technology BH100 user manual

Salto
Salto Comfort E1CD0x00fft installation guide

Paxton Access
Paxton Access TOUCHLOCK K Series installation guide

SDC
SDC Z7700 Series installation instructions

Baldwin
Baldwin RESERVE 47038 / 03 Quick user guide

ViziT
ViziT VIZIT-ML300 Series Operating instruction