* Battery Power Check
When the power up, the device will detect the power level of the
attery immediately. If the power level is too low, the LED will continue
flash a out 5 seconds. Please change another new attery.
* Network State Check
When the power on, the device will check the network state. If the
device join network , the LED will steady off. If doesn't, The LED will
flash in every second and continue 120 seconds.
* PIR Warm Up
When the power on, the PIR need to warm up efore operation. The
warm up time a out 1 minute, the LED will flash in every 2 seconds.
After finish the procedure the LED will light ON three times.
* Try joining network
When the power on, the device will check is it already adding to the
network? If doesn't, it will auto start the joining network mode. Until
timeout or the device joined network.
* lost network
When the device power on, the device will check is it already adding to
the network?
If does, ut can't handshake, the device will try to link with zig ee
network every minute.
After 6 times, the device LED will flash in every second and continue 30
seconds.
The cycle will not stop until join the network.
This will cause the attery to continue to consume power.
Over The Air (OTA) Firmware Update
The device support the Zig ee firmware update via OTA.
Before starting the procedure, please remove the front cover of the
device. Otherwise the hardware check will e failed.
The Device will find the OTA server in the network. The OTA server will
provide the necessary information to device. The device will decide if
the OTA is necessary.
Operation Mode
There are two operation modes of the device. The user can choosing
the suita le mode for application.
There are two modes “Test” and “Normal”.
“Test Mode” is for the user test the sensor function when installation.
“Normal Mode” is for the user normal use.
When the event triggered, In “Normal Mode” the LED won't indicated,
unless the attery is in the low level, the LED will flash once. And in the
“Test Mode” the LED also will light ON one second.
The PIR motion re-detected interval, in the “Test Mode” fixed to 8
seconds. In the “Normal Mode”, the PIR motion will start re-detected
interval around 30 seconds.
Notice When the tamper key of the ack side is in the released state,
the device always in the “Test Mode”.
Choosing a Suitable Location
1. The recommended mounting height is 160cm
2. Don't let the device facing the window or the sunlight.
3. Don't let the device facing the source of heat. For instance the
heater or the air-condition.
5