manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Philips
  6. •
  7. Indoor Furnishing
  8. •
  9. Philips 276626 User manual

Philips 276626 User manual

5"
81/4"
Pulse Start Metal Halide 175Watt Lamp (Clear)
■Ordering Information
Ordering Code MS175/BU/PS
ANSI Designation M137/E
Product Number 276626
Description Pulse Start Metal Halide
Package Quantity 12
■Physical Characteristics
Bulb Size ED-28
Bulb Finish Clear
Base (Nickel Plated Brass) Mogul-Screw
Max.Overall Length (MOL) 8 5/16'' (211mm)
Light Center Length (LCL) 5.0'' (127mm)
Arc Length .78'' (20mm)
ArcTube Material Quartz
Max.Permissible BulbTemp. 400ºC (752ºF)
Max.Permissible BaseTemp. 210ºC (410ºF)
Max.Bulb to Base Eccentricity 3º
Max.ArcTube to Base Eccentricity 3º
■Operating Characteristics (Photometric)
Rated Initial Lumens 16,000
Mean Lumens,Approx. 11,200
RatedAverage Life,Hours 15,000
Correlated ColorTemp. (CCT) 3700K
CIE ChromaticityApprox. x-.396,y-.390
Color Rendering Index (CRI) 65
Efficacy (lpw) 91
■Operating Position
Base Up ± 15º-Enclosed Luminaires Only
Note:Pulse Start Metal Halide is Designed for Operation on OnlyApproved
Ballasts with Metal Halide Pulse Ignitors.
MS175/BU/PS
Lumen Maintenance
BURNING HOURS
RATEDAVERAGE LIFE 15,000 HOURS
100%
80%
60%
40%
20%
0% 0 2000 4000 6000 8000
% LUMEN
MAINTENANCE
Electrical Data (Subject to change without notice)
Warnings, Cautions and Operating Instructions
“WARNING:These lamps can cause serious skin burn and eye inflammation
from short wave ultraviolet radiation if outer envelope of the lamp is broken or
punctured.Do not use where people will remain for more than a few minutes
unless adequate shielding or other safety precautions are used. Certain lamps
that will automatically extinguish when the outer envelope is broken or punctured
are commercially available.”This lamp complies with FDA radiation performance
standard 21 CFR subchapter J.(USA:21CFR 1040.30 Canada:SOR/DORS/80-381)
If the outer bulb is broken or punctured,turn off at once and replace the lamp
to avoid possible injury from hazardous short wave ultraviolet radiation. Do not
scratch the outer bulb or subject it to pressure as this could cause the outer bulb
to crack or shatter.A partial vacuum in the outer bulb may cause glass to fly if the
envelope is struck.
WARNING:The arc-tube of metal halide lamps are designed to operate under
high pressure and at temperatures up to 1000ºC and can unexpectedly rupture
due to internal or external factors such as a ballast failure or misapplication.
If the arc-tube ruptures for any reason,the outer bulb may break and pieces of
extremely hot glass might be discharged into the surrounding environment.If such
a rupture were to happen,THERE ISA RISK OF PERSONAL INJURY, PROPERTY
DAMAGE,BURNSAND FIRE.
Certain lamps that will retain all the glass particles should inner arc-tube rupture
occur are commercially available from Philips Lighting Company.
RELAMP FIXTURESAT OR BEFORETHE END OF RATED LIFE. Allowing lamps
to operate until they fail is not advised and may increase the possibility of inner
arc tube rupture.
CAUTION: TO REDUCETHE RISK OF PERSONAL INJURY,PROPERTY
DAMAGE,BURNSAND FIRE RESULTING FROMAN ARC-TUBE RUPTURE
THE FOLLOWING LAMP OPERATING INSTRUCTIONS MUST BE FOLLOWED.
Lamp Operating Instructions:
1)Turn off lamps at least once a week for at least 15 minutes in systems which
are operating on a continuous basis (24 hours/day-7days/week).FAILURETO
TURN OFF LAMPS FORTHE MINIMUM RECOMMENDEDTIME MAY
INCREASETHE POSSIBILITY OFAN INNER ARC-TUBE RUPTURE.
2) RELAMP FIXTURESAT OR BEFORETHE END OF RATED LIFE. Allowing
lamps to operate until they fail is not advised and may increase the possibility
of inner arc tube rupture.
3) Use only in an enclosed fixture capable of withstanding particles of glass having
temperatures up to 1000ºC.
4) Before lamp installation/replacement, shut power off and allow lamp and
fixture to cool to avoid electrical shock and potential burn hazards.
5) Use only auxiliary equipment meeting Philips and /or ANSI standards.
Use within voltage limits recommended by ballast manufacturer.
A.Operate lamp only within specified limits of operation.
B.For total supply load refer to ballast manufacturers electrical data.
C.All Pulse Start mogul based lamps require a socket rated to withstand
a 4000 volt pulse.
6) Periodically inspect the outer envelope.Replace any lamps that show scratches,
cracks or damage.
7) If a lamp bulb support is used, be sure to insulate the support electrically to
avoid possible decomposition of the bulb glass.
8) Protect lamp base,socket and wiring against moisture,corrosive atmospheres
and excessive heat.
9)Time should be allowed for lamps to stabilize in color when turned on for the
first time.This may require several hours of operation,with more than one
start. Lamp color is also subject to change under conditions of excess vibration
or shock,and color appearance may vary between individual lamps.
10) Lamps may require 2 to 4 minutes to re-light if there is a power interruption.
11)Take care in handling and disposing of lamps.If an arc tube is broken,avoid
skin contact with any of the contents or fragments.
12) Use this lamp only in fixtures that contain a Pulse Start metal halide ballast
and are specifically designed for use with Pulse Start metal halide lamps.
Philips Lighting Company
200 Franklin Square Drive ■P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
www.lighting.philips.com/nam
A Division of Philips Electronics NorthAmerica Corporation
Updated 2/02 PSMH 001
Philips Lighting
281 Hillmount Road
Markham, Ontario L6C 2S3
A Division of Philips Electronics Limited
LampWatts (Nominal). . . . . . . . . . . . . . . . . . . . . . . . . 175
Lamp OperatingVoltage (rms) (Nominal). . . . . . . . . . . 132
Initial LampVoltage Range (rms). . . . . . . . . . . . . . . . . . 120–140
Lamp Operating Current (Amps) (rms) (Nominal). . . . 1.5
Lamp Current Crest Factor (Maximum). . . . . . . . . . . . 1.6
Warm-upTime to 90% of Output . . . . . . . . . . . . . . . . 2 Minutes
Re-strikeTime for Hot Lamp. . . . . . . . . . . . . . . . . . . . 4 Minutes
BallastType. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANSI M137/E
Ballast Open CircuitVoltage (Minimum). . . . . . . . . . . . 245 RMS Min.
Pulse PeakVolts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000 Min., 4000 Max.
PulseWidth @ 90% Peak (micro sec) . . . . . . . . . . . . . 1.3
Pulse Repetition Rate (Minimum). . . . . . . . . . . . . . . . . 1x/1/2cycle
Minimum OperatingTemperature. . . . . . . . . . . . . . . . . -30ºC
AdvanceTransformer Ballast Number . . . . . . . . . . . . . 71A5592
Pulse Start Metal Halide 175 Watt Lamp (Clear)
Philips
Lighting
Company

Other Philips Indoor Furnishing manuals

Philips LAA31AYBC/12 User manual

Philips

Philips LAA31AYBC/12 User manual

Philips LivingColors 691503148 User manual

Philips

Philips LivingColors 691503148 User manual

Philips Baby NightLight Owner's manual

Philips

Philips Baby NightLight Owner's manual

Philips Elite MHC-08100 User manual

Philips

Philips Elite MHC-08100 User manual

Philips Imageo AquaLight 691183148 User manual

Philips

Philips Imageo AquaLight 691183148 User manual

Philips Mini300 User manual

Philips

Philips Mini300 User manual

Philips Elite 3000K User manual

Philips

Philips Elite 3000K User manual

Philips TL5-09100 User manual

Philips

Philips TL5-09100 User manual

Philips 14477-4 User manual

Philips

Philips 14477-4 User manual

Philips P-5760-A User manual

Philips

Philips P-5760-A User manual

Philips LAA31AWWC/12 User manual

Philips

Philips LAA31AWWC/12 User manual

Philips P-5497-F User manual

Philips

Philips P-5497-F User manual

Philips 20285-3 User manual

Philips

Philips 20285-3 User manual

Philips 15701-6 User manual

Philips

Philips 15701-6 User manual

Philips 223289 User manual

Philips

Philips 223289 User manual

Philips 14649-8 User manual

Philips

Philips 14649-8 User manual

Philips Ledino 66702/87/16 User manual

Philips

Philips Ledino 66702/87/16 User manual

Philips 154948 User manual

Philips

Philips 154948 User manual

Philips 151043 User manual

Philips

Philips 151043 User manual

Philips Coloured CandleLights User manual

Philips

Philips Coloured CandleLights User manual

Philips Brighter Light User manual

Philips

Philips Brighter Light User manual

Philips Ledino 66701/87/16 User manual

Philips

Philips Ledino 66701/87/16 User manual

Philips T8 User manual

Philips

Philips T8 User manual

Philips Ledino 33601/30/16 User manual

Philips

Philips Ledino 33601/30/16 User manual

Popular Indoor Furnishing manuals by other brands

Heartland 9200 Installation requirements

Heartland

Heartland 9200 Installation requirements

Sunnydaze Decor CRO-126 manual

Sunnydaze Decor

Sunnydaze Decor CRO-126 manual

Monarch Specialties I 1030 Assembly instructions

Monarch Specialties

Monarch Specialties I 1030 Assembly instructions

Denver SS 9046 Assembly instructions

Denver

Denver SS 9046 Assembly instructions

avaks nabytok REA Wave 2 Assembly instructions

avaks nabytok

avaks nabytok REA Wave 2 Assembly instructions

kupper 12030 Assembly instruction

kupper

kupper 12030 Assembly instruction

Songmics VASAGLE LSC76 manual

Songmics

Songmics VASAGLE LSC76 manual

Merax WF197808 Assembly instructions

Merax

Merax WF197808 Assembly instructions

LDI Spaces SAFCO 9331 Assembly instructions

LDI Spaces

LDI Spaces SAFCO 9331 Assembly instructions

Amada AMFS14 instruction manual

Amada

Amada AMFS14 instruction manual

Studio Henk Pillar Coffee Table manual

Studio Henk

Studio Henk Pillar Coffee Table manual

ACID Core Products TXG517 manual

ACID

ACID Core Products TXG517 manual

Classic Exhibits visionary DESIGNS MOD-1181 Assembly

Classic Exhibits

Classic Exhibits visionary DESIGNS MOD-1181 Assembly

Habitat OLDEANIA 4165446 quick start guide

Habitat

Habitat OLDEANIA 4165446 quick start guide

Progressive T365-29 Assembly instructions

Progressive

Progressive T365-29 Assembly instructions

noken VINTAGE 100240166 manual

noken

noken VINTAGE 100240166 manual

Plust FADE CHAIR Assembly instructions

Plust

Plust FADE CHAIR Assembly instructions

StyleWell DP18009-TABLE Use and care guide

StyleWell

StyleWell DP18009-TABLE Use and care guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.