7"
11 1/2"
◗Ordering Information
Ordering Code S400/U/PS
ANSI Designation 155/ 135/E
Product Number 232835
Description Pulse Start etal Halide
Package Quantity 6
◗Physical Characteristics
Bulb Size ED-37
Bulb Finish Clear
Base (Nickel Plated Brass) ogul-Screw
aximum Overall Length ( OL) 11 1/2'' (292mm)
Light Center Length (LCL) 7.0'' (178mm)
Arc Length 1.57'' (40mm)
Arc Tube aterial Quartz
ax. Permissible Bulb Temp. 400ºC (752ºF)
ax. Permissible Base Temp. 210ºC (410ºF)
ax. Bulb to Base Eccentricity 3º
ax.Arc Tube to Base Eccentricity 3º
◗Operating Characteristics (Photometric)
Horizontal Vertical
Approx. Initial Lumens1,2 36,800 40,000
Approx. ean Lumens1,3,4 25,760 28,000
Rated Average Life, Hours515,000 15,000
Correlated Color Temp. (CCT)34300K 3800K
Color Rendering Index (CRI) 62 62
Efficacy (lpw) 92 100
CIE Chromacity Approx.3x-.380, y-.405
◗Operating Position
Universal
Note: Pulse Start etal Halide is designed for operation on only approved ballasts
with etal Halide Pulse Ignitors.
Pulse Start Universal etal Halide
400 Watt Lamp (Clear)
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
ADivision of Philips Electronics North America Corporation
Updated 1/09 TDS-232835
Philips Lighting
281 Hillmount oad
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
www.philips.com
Warnings, Cautions and Operating Instructions
“WA NING: These lamps can cause serious skin burn and eye inflammation
from short wave ultraviolet radiation if outer envelope of the lamp is broken or
punctured. Do not use where people will remain for more than a few minutes unless
adequate shielding or other safety precautions are used. Certain lamps that will
automatically extinguish when the outer envelope is broken or punctured are
commercially available." This lamp complies with FDA radiation performance
standard 21 CFR subchapter J. (USA:21CFR 1040.30 Canada:SOR/DORS/80-381)
If the outer bulb is broken or punctured, turn off at once and replace
the lamp to avoid possible injury from hazardous short wave ultraviolet
radiation. Do not scratch the outer bulb or subject it to pressure as this
could cause the outer bulb to crack or shatter.A partial vacuum in the
outer bulb may cause glass to fly if the envelope is struck.
WA NING: The arc-tube of metal halide lamps are designed to operate under
high pressure and at temperatures up to 1000ºC and can unexpectedly rupture due
to internal or external factors such as a ballast failure or misapplication. If the
arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely
hot glass might be discharged into the surrounding environment. If such a rupture
were to happen, THE E IS A ISK OF PE SONAL INJU Y, P OPE TY
DAMAGE, BU NS AND FI E.
Certain lamps that will retain all the glass particles should inner arc-tube
rupture occur are commercially available from Philips Lighting Company.
ELAMP FIXTU ES AT O BEFO E THE END OF ATED LIFE.
Allowing lamps to operate until they fail is not advised and may increase
the possibility of inner arc tube rupture.
CAUTION: TO REDUCE THE RISK OF PERSONAL INJURY, PROPERTY
DA AGE, BURNS AND FIRE RESULTING FRO AN ARC-TUBE RUPTURE THE
FOLLOWING LA P OPERATING INSTRUCTIONS UST BE FOLLOWED.
Lamp Operating Instructions:
1) Turn off lamps at least once a week for at least 15 minutes in systems which are
operating on a continuous basis (24 hours/day-7days/week). FAILURE TO TURN
OFF LA PS FOR THE INI U RECO ENDED TI E AY INCREASE
THE POSSIBILITY OF AN INNER ARC-TUBE RUPTURE.
2) RELA P FIXTURES AT OR BEFORE THE END OF RATED LIFE.Allowing
lamps to operate until they fail is not advised and may increase the possibility
of inner arc tube rupture.
3) Use only in an enclosed fixture capable of withstanding particles of glass having
temperatures up to 1000ºC.
4) Before lamp installation/replacement, shut power off and allow lamp and fixture
to cool to avoid electrical shock and potential burn hazards.
5) Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within
voltage limits recommended by ballast manufacturer.
A. Operate lamp only within specified limits of operation.
B. For total supply load refer to ballast manufacturers electrical data.
C. All Pulse Start mogul based lamps require a socket rated to withstand
a 4000 volt pulse.
6) Periodically inspect the outer envelope. Replace any lamps that show scratches,
cracks or damage.
7) If a lamp bulb support is used, be sure to insulate the support electrically to
avoid possible decomposition of the bulb glass.
8) Protect lamp base, socket and wiring against moisture, corrosive atmospheres
and excessive heat.
9) Time should be allowed for lamps to stabilize in color when turned on for the
first time.This may require several hours of operation, with more than one start.
Lamp color is also subject to change under conditions of excess vibration or
shock, and color appearance may vary between individual lamps.
10) Lamps may require 2 to 4 minutes to re-light if there is a power interruption.
11) Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin
contact with any of the contents or fragments.
12) Use this lamp only in fixtures that contain a Pulse Start metal halide ballast and
are specifically designed for use with Pulse Start metal halide lamps.
LampWatts(Nominal).............................400
Lamp Operating Voltage (rms) (Nominal)3.............135
Initial Lamp Voltage ange (rms)6.....................120–150
Lamp Operating Current (Amps) (rms) (Nominal) . . . . . 3.25
Lamp Current Crest Factor (Maximum) . . . . . . . . . . . . . . 1.6
Warm-up Time to 90% of Output . . . . . . . . . . . . . . . . . . . 10 Minutes
e-strike Time for Hot Lamp . . . . . . . . . . . . . . . . . . . . . . . . < 5 Minutes
BallastType.......................................ANSIM155/M135/E
Ballast Open Circuit Voltage (Minimum). . . . . . . . . . . . . . . 254V Min.
PulsePeakVolts ...................................3000Min.,4000Max.
Pulse Width @ 90% Peak (micro sec). . . . . . . . . . . . . . . . . 1.3
Pulse epetition ate (Minimum) . . . . . . . . . . . . . . . . . . . . 1x/1/2cycle
Minimum Operating Temperature . . . . . . . . . . . . . . . . . . . . -30ºC
Philips Lighting Electronics Ballast Number . . . . . . . . . . . . 71A6092
Pulse Start Universal etal Halide 400 Watt Lamp (Clear)
Electrical Data (Subject to change without notice)
1) Approximate lumen values listed are for horizontal operation of the lamp.
2) Measured at 100 hours of life in horizontal position.
3) Measured at rated lamps on a linear reactor. LPW does not include ballast losses.
4) Approximate lumen output at 40% of lamp rated average life.
5) ated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start.
It is based on survival of at least 50% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average.
6) Measured with the lamp operation at rated watts.

This manual suits for next models

1

Other Philips Indoor Furnishing manuals

Philips 14691-0 User manual

Philips

Philips 14691-0 User manual

Philips A55 Clear User manual

Philips

Philips A55 Clear User manual

Philips Ledino 44992/30/16 User manual

Philips

Philips Ledino 44992/30/16 User manual

Philips Coloured CandleLights User manual

Philips

Philips Coloured CandleLights User manual

Philips Compact HID Lamp and Gear User manual

Philips

Philips Compact HID Lamp and Gear User manual

Philips 131623 User manual

Philips

Philips 131623 User manual

Philips 691123148 User manual

Philips

Philips 691123148 User manual

Philips Mini300 User manual

Philips

Philips Mini300 User manual

Philips 228114 Instruction Manual

Philips

Philips 228114 Instruction Manual

Philips P-2055-D User manual

Philips

Philips P-2055-D User manual

Philips 383810 User manual

Philips

Philips 383810 User manual

Philips 151423 User manual

Philips

Philips 151423 User manual

Philips 144758 User manual

Philips

Philips 144758 User manual

Philips 207530 User manual

Philips

Philips 207530 User manual

Philips Office Lighting User manual

Philips

Philips Office Lighting User manual

Philips 20285-3 User manual

Philips

Philips 20285-3 User manual

Philips 14477-4 User manual

Philips

Philips 14477-4 User manual

Philips Elite MHC-08100 User manual

Philips

Philips Elite MHC-08100 User manual

Philips Lamps IRC MR16 User manual

Philips

Philips Lamps IRC MR16 User manual

Philips Ledino 33602/31/16 User manual

Philips

Philips Ledino 33602/31/16 User manual

Philips HF3461 User manual

Philips

Philips HF3461 User manual

Philips LAA61BYWC/10 User manual

Philips

Philips LAA61BYWC/10 User manual

Philips TCS125 User manual

Philips

Philips TCS125 User manual

Philips Ledino 41618/60/16 User manual

Philips

Philips Ledino 41618/60/16 User manual

Popular Indoor Furnishing manuals by other brands

Regency LWMS3015 Assembly instructions

Regency

Regency LWMS3015 Assembly instructions

Furniture of America CM7751C Assembly instructions

Furniture of America

Furniture of America CM7751C Assembly instructions

Safavieh Furniture Estella CNS5731 manual

Safavieh Furniture

Safavieh Furniture Estella CNS5731 manual

PLACES OF STYLE Ovalfuss Assembly instruction

PLACES OF STYLE

PLACES OF STYLE Ovalfuss Assembly instruction

Trasman 1138 Bo1 Assembly manual

Trasman

Trasman 1138 Bo1 Assembly manual

Costway JV10856 manual

Costway

Costway JV10856 manual

moss DESIGN Caisson Credenza Assembly instructions

moss DESIGN

moss DESIGN Caisson Credenza Assembly instructions

Aquaglide FULL DECK 15.0 owner's manual

Aquaglide

Aquaglide FULL DECK 15.0 owner's manual

AREBOS AR-HE-SW30 user manual

AREBOS

AREBOS AR-HE-SW30 user manual

Till-Hilft Fulda 87005.330 Assembly instructions

Till-Hilft

Till-Hilft Fulda 87005.330 Assembly instructions

Twoey Outside 2010 quick start guide

Twoey Outside

Twoey Outside 2010 quick start guide

Hettich Easys 200 operating instructions

Hettich

Hettich Easys 200 operating instructions

The bedboss RELAX 404 Series owner's manual

The bedboss

The bedboss RELAX 404 Series owner's manual

Oeseder Möbelindustrie Bern 991 720 Assembly instructions

Oeseder Möbelindustrie

Oeseder Möbelindustrie Bern 991 720 Assembly instructions

Costway HW68469 user manual

Costway

Costway HW68469 user manual

Next ALIX A27743 Assembly instructions

Next

Next ALIX A27743 Assembly instructions

BROSA Hans Assembly guide

BROSA

BROSA Hans Assembly guide

Prodigg MINIKA PBA015T-FUR installation manual

Prodigg

Prodigg MINIKA PBA015T-FUR installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.