Phoenix EcoMod 3 Series User manual

EcoMod®3 Series
Installation Instructions
Phoenix Lighting 8711 West Port Avenue Milwaukee, WI 53224 USA
Phone: +1 414.973.3300 Toll Free: 800.438.1214 Fax: +1 414.973.3210 www.phoenixlighting.com
!CAUTION
• All wiring should be done by a licensed electrician in accordance with state codes, local codes, and National Electric Code (NEC) standards or International
Electrotechnical Commission (IEC) standards.
• Improper installation may result in serious injury and void warranty.
• Contains parts and assemblies susceptible to damage by electrostatic discharge (ESD).
• If the external flexible cable or cord of this luminaire is damaged, it shall be replaced with a cord with equivalent markings and ratings or a cord exclusively
available from the manufacturer.
• The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
• To reduce the risk of strangulation the flexible wiring connected to this luminaire shall be effectively fixed to the wall if the wiring is within arm’s reach.
• Surge protective devices should be utilized for fixtures installed in environments subject to power surges outside the specified operating parameters.
• Ensure control circuits (dimming circuits) are adequately separated from primary circuits (incoming AC supply circuit) when installing control devices or
control wiring.
Weight & Dimensions
LO - 31.0 lb (14.1 kg)
HI - 39.6 lb (18.0 kg)
MAX - 49.2 lb (22.3 kg)
EPA (wind load) Values
LO - 1.7 sq. ft. (0.2 m)
HI - 2.0 sq. ft. (0.2 m)
MAX - 2.7 sq. ft. (0.3 m)
LO Model
18.64 in (473 mm)
12.72 in (323 mm)
HI Model
25.53 in (648 mm)
12.72 in (323 mm)
MAX Model
12.23 in (311 mm)
12.27 in (312 mm)
13.87 in (352 mm)
18.64 in (473 mm)
10.65 in (271 mm)

Installation Instructions
EcoMod®3 Series
Phoenix Lighting 8711 West Port Avenue Milwaukee, WI 53224 USA
Phone: +1 414.973.3300 Toll Free: 800.438.1214 Fax: +1 414.973.3210 www.phoenixlighting.com
EcoMod 3 LO & HI
Figure 1: Dimensions for Standard Mounting Brackets
Contact factory for dimensions on custom mounting brackets.
Wiring
The standard fixture is supplied with a six foot cord and pigtail.
Green/yellow is ground (PE), brown is hot and blue is common.
Standard fixture to accommodate wire gauges ranging from 28 AWG (0.08 mm)
to 12 AWG (2.5 mm).
Mounting
Fasten fixture with 3 x ½ inch (M12) bolts (not provided) through center hole and
slots in harp assembly to a recommended torque of 45 foot-pounds. Standard
mounting hole dimensions shown in Figure 1. Attach near corner supports and
use subbase appropriate for the weight of the fixture.
terminal block
line
neutral
L N G
ground dimming -
dimming +
D+ D-
17.72 in (450 mm)
12.00 in (305 mm)
5.98 in (152 mm)
0.56 in (14 mm)
20˚ 24˚
4.93 in (125 mm)
10.50 in (267 mm)
0.63 in (16 mm)
3.94 in (100 mm)
5.98 in (152 mm)
10.00 in (254 mm)
12.00 in (305 mm)
15.00 in (381 mm)

Phoenix Lighting 8711 West Port Avenue Milwaukee, WI 53224 USA
Phone: +1 414.973.3300 Toll Free: 800.438.1214 Fax: +1 414.973.3210 www.phoenixlighting.com
EcoMod®3 Series
Installation Instructions
EcoMod 3 MAX
Suitable Aiming Positions
Note: Fixture must not be aimed at mounting surface.
0
24.61 in (625 mm)
18.00 in (457 mm)
5.68 in (144 mm)
0.56 in (14 mm)
7.09 in (180 mm)
17.74 in (451 mm)
11.68 in (297 mm)
0.375 in (10 mm)
0.91 in (23 mm)
8.66 in (220 mm)
11.80 in (300 mm)
14.96 in (380 mm)
135

Installation Instructions
EcoMod®3 Series
Phoenix Lighting 8711 West Port Avenue Milwaukee, WI 53224 USA
Phone: +1 414.973.3300 Toll Free: 800.438.1214 Fax: +1 414.973.3210 www.phoenixlighting.com
EM3-MAX Repair Parts List
Description Part Number Quantity per fixture
Cool white (5000K) LED
board kit 010610.990 6
Neutral white (4000K) LED
board kit 010610.991 6
Warm white (2700K) LED
board kit 010610.992 6
EM3-MAX lens cover kit 010612.999 1
EM3-MAX 120-277V driver kit 010612.998 2
EM3-MAX 277-480V driver kit 010615.998 2
VS optic kit 010610.980 6
SP optic kit 010610.982 6
MF optic kit 010610.984 6
WF optic kit 010610.985 6
NG optic kit 010610.986 6
EM3-HI Repair Parts List
Description Part Number Quantity per fixture
Cool white (5000K) LED
board kit 010610.990 4
Neutral white (4000K) LED
board kit 010610.991 4
Warm white (2700K) LED
board kit 010610.992 4
EM3-HI lens cover kit 010611.999 1
EM3-HI 120-277V driver kit 010611.998 1
EM3-HI 277-480V driver kit 010614.998 1
VS optic kit 010610.980 4
SP optic kit 010610.982 4
MF optic kit 010610.984 4
WF optic kit 010610.985 4
NG optic kit 010610.986 4
EM3-LO Repair Parts List
Description Part Number Quantity per fixture
Cool white (5000K) LED
board kit 010610.990 2
Neutral white (4000K) LED
board kit 010610.991 2
Warm white (2700K) LED
board kit 010610.992 2
EM3-LO lens cover kit 010610.999 1
EM3-LO 120-277V driver kit 010610.998 1
EM3-LO 277-480V driver kit 010613.998 1
VS optic kit 010610.980 2
SP optic kit 010610.982 2
MF optic kit 010610.984 2
WF optic kit 010610.985 2
NG optic kit 010610.986 2

EcoMod®3 Series
Installation Instructions
N5499978B
07.08.23
Maintenance
Periodic maintenance and cleaning is required to keep light fixture in peak operating condition. Buildup of dirt and/or debris will diminish performance, lead
to premature failure and void the fixture’s warranty.
1. Inspect fixture monthly or (more frequently if conditions require) for dirt and debris buildup on lenses and between fins of heatsink. Wash down with
water as needed.
2. Inspect fasteners and verify cord grips are tight. Retighten as needed.
Note: Cord grips should be hand tight plus ¼ turn.
FCC Notice (Class A)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Federal Communications Commission Statement
NOTE: This equipment has been verified and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference. This equipment generates uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by tuning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the equipment.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the factory, factory representative,
or an experienced technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment."
Phoenix Lighting 8711 West Port Avenue Milwaukee, WI 53224 USA
Phone: +1 414.973.3300 Toll Free: 800.438.1214 Fax: +1 414.973.3210 www.phoenixlighting.com
Safety Cable Installation
Phoenix strongly suggests using a safety cable when installing EcoMod 3
fixtures. A safety cable comes standard with each EcoMod 3 fixture.
1. Locate a sturdy support structure for the safety cable. Please keep in mind
that the safety cable is 60.00 inches (1524 mm) long and must be able to
loop around a sturdy bar or bracket on the support structure.
2. Take the loop end of the cable and wrap it around the bar/bracket on the
support structure.
3. Insert nut (provided) into the retention feature (“pocket”) in the fixture
casting (refer to Figure 2).
4. Place the M8 lock washer (provided) and M8 flat waster (provided) onto
the M8 bolt (refer to Figure 2).
5. Insert the bolt through the eyelet of the safety cable and the machined
hole in the fixture casting into the pocket holding the nut (refer to Figure 2)
6. Fasten bolt to nut, torque to 10-15 lb-ft.
This manual suits for next models