EcoMod®3 Series
Installation Instructions
N5499978B
07.08.23
Maintenance
Periodic maintenance and cleaning is required to keep light fixture in peak operating condition. Buildup of dirt and/or debris will diminish performance, lead
to premature failure and void the fixture’s warranty.
1. Inspect fixture monthly or (more frequently if conditions require) for dirt and debris buildup on lenses and between fins of heatsink. Wash down with
water as needed.
2. Inspect fasteners and verify cord grips are tight. Retighten as needed.
Note: Cord grips should be hand tight plus ¼ turn.
FCC Notice (Class A)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Federal Communications Commission Statement
NOTE: This equipment has been verified and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference. This equipment generates uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by tuning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the equipment.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the factory, factory representative,
or an experienced technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment."
Phoenix Lighting 8711 West Port Avenue Milwaukee, WI 53224 USA
Phone: +1 414.973.3300 Toll Free: 800.438.1214 Fax: +1 414.973.3210 www.phoenixlighting.com
Safety Cable Installation
Phoenix strongly suggests using a safety cable when installing EcoMod 3
fixtures. A safety cable comes standard with each EcoMod 3 fixture.
1. Locate a sturdy support structure for the safety cable. Please keep in mind
that the safety cable is 60.00 inches (1524 mm) long and must be able to
loop around a sturdy bar or bracket on the support structure.
2. Take the loop end of the cable and wrap it around the bar/bracket on the
support structure.
3. Insert nut (provided) into the retention feature (“pocket”) in the fixture
casting (refer to Figure 2).
4. Place the M8 lock washer (provided) and M8 flat waster (provided) onto
the M8 bolt (refer to Figure 2).
5. Insert the bolt through the eyelet of the safety cable and the machined
hole in the fixture casting into the pocket holding the nut (refer to Figure 2)
6. Fasten bolt to nut, torque to 10-15 lb-ft.