PickData Pick 3G User manual

V01-230519
TECHNICAL CHARACTERISTICS
PICK 3G
Pick 3G is a gateway designed to communicate with machines and
sensors, collect and store their data and send it to the website for their
treatment.
The gateway’s main feature is the communication using 3G, which can
be swapped to GPRS when there’s no 3G network coverage.
Pick 3G has an internal and an external antenna with a switch to select
which one is going to be used. The modem adds an Ethernet port, RS-
485, an auxiliary 12 V tension output and a relay output.
Finally, Pick 3G can communicate to EVO platform through 3G/GPRS or
Ethernet.
Power circuit
Input voltage
85 … 265 Vac / 120 ... 300 Vdc
Maximum consumption
6.5 … 9.5 VA / 3.5 … 4.2 W
Auxiliary output voltage
12 Vdc
Auxiliary output voltage maximum power
1 W
Environmental conditions
Temperature range
-10 …. +60ºC
Humidity range
5 …. 95%
Mechanical characteristics
Enclosure material
Plastic UL94 –V0 Self-extinguishable
Protection grade
IP30
Unit dimensions (Width x Height x Length)
152 x 150 x 44 mm
Weight
130 g
Mounting
Wall mounting / DIN Rail with an accessory
Maximum working altitude
2000 m
Radio connection
Internal antenna
Yes
External antenna connector
Yes
Modem
SIM
Not included
Ethernet
1 port 10/100
Serial port
1 port RS-485
External antenna type
SMA female
Characteristics and electrical security
Security
CAT III 300 V under EN 61010
Electric shock protection
Double insulation class II
Standards
Standards
UNE EN 61010-1:2010, UNE-EN 61000-6-2, UNE-EN 61000-6-4

V01-230519
CONNECTIONS AND LEDS
Led
Description
CPU Activity
Activity: Blinking green
Ethernet
Connection and traffic: Blinking green
Only connection: Green
Without connection: Off
Connectivity
3G connection in progress: Green led blinks slowly
3G connection established: Green led on
2G connection in progress: Red led blinks slowly
2G connection established: Red led on
Without connection: Red led blinks fast
RS-485
Data transmission: Red
Data reception: Green
12VDC Output
12 Vdc voltage: Green
Relay
Activated: Green
INSTALLATION
1 SIM placement or Ethernet connection
•
PICK 3G has two communication modes, using the 3G module or the Ethernet port. To
communicate by 3G, you should insert your SIM card (with PIN deactivated) in the slot
located at device’s back, removing the cover and inserting the card as shown in the
figure. To communicate by Ethernet, connect a category 5 network cable or higher from
your device/router to the gateway.
•
To load the factory configuration, power the device and press the Reset button for 5-
10 seconds. This will lead the device to be re-accessible by IP 192.168.1.1 to change
any configuration setting
2
Montage
•
Enter your hand at the bottom of the case and pull up to remove the connection zone protection.
•
Remove the connectors, put the device on the installation plane surface, mark the holes and attach the device

V01-230519
3
Power
•
Connect the plugs L and N to a power outlet. Lay the cables through the bottom of the case or use the case back
holes.
4
Device setup
•
By default, the device has IP 192.168.1.1 which can be changed at control panel accessed through this IP. Once
inside the panel, you should choose the communication mode between 3G and Ethernet and configure the
parameters of the mode selected. When you’ve finished, save changes and reset your gateway.
5
3G signal
•
Once the device is configured, check that the CPU and Modem leds start to blink.
•
The device register to the 2G/3G network may take between 1 and 5 minutes depending on the coverage. The
process will have finished when Modem led stop blin- king (review the led codification table for more information).
•
If you want to gain signal strength you need to connect an auxiliary an- tenna to the external connector and change
de switch to EXTposition as you can see in the figure.
6
Devices connection
•
To communicate by Ethernet, connect a category 5 network cable or higher from your Modbus/TCP RS-485
converter to the gateway.
•
To communicate using RS-485, connect a twin twisted cable between plugs A+ and B-, and follow the connection
standard rules based on RS-485 communications.

V01-230519
7
Checks and register
•
To finish your gateway installation, you should access https://evo.pickdata.net, join with you user account and
register your device using Register button of Hardware menu. You could find theinformation needed to complete
the register at the device label.
•
If you have a problem during the installation you can contact us at: http://www.pickdata.net/support
MODEL REFERENCE
Model
Reference
Protocol
Communication
Pick 3G
G003
Modbus/RTU
Modbus/TCP
RS-485
Ethernet
3G/GPRS
EXTERNAL ANTENNA REFERENCE
In case that an external antenna is needed:
Model
Reference
Cable length
Connector type
Antenna wall-mounted indoor
E001
2 meters
SMA Male
Antivandal antenna IP67 multi-band LORA/4G 1 mt
E032
1 meter
SMA Male
SAFETY PRECAUTIONS
DANGER
Warns of a risk, which could result in personal injury or material damage caused by an incorrect handling
or installation of the unit. In particular, handling with voltages applied may result in electric shock, which
may cause death or serious injury to personnel. Defective installation or maintenance may also lead to
the risk of fi re. Read the manual carefully prior to connecting the unit. Follow all installation and
maintenance instructions throughout the unit’s working life. Pay special attention to the installation
standards of the National Electrical Code.
DISCLAIMER
PickData, SL reserves the right to make modifications to the device or the unit specifications set out in this instruction
manual without prior notice.
PickData, SL on its web site, supplies its customers with the latest versions of the device specifications and the most
updated manuals.
MAINTENANCE AND TECHNICAL SERVICE
Device doesn’t require maintenance.
In the case of any query in relation to unit operation or malfunction, please contact the PickData, SL technical support
service.
PickData, SL –Technical support service
Calle Innovació, 3
08232 –Viladecavalls (Barcelona), SPAIN
Tel: (34) 935 117 505 (España)
Email: sat@pickdata.net