PXI 34-Channel, 4-Bus, 2A Fault Insertion Switch 40-197
ISSUE 3.1 DEC 2019
• 34 or 16 Fault Insertion Channels
• 4 Buses For Inserting Fault Conditions, Each
With a Changeover Switch For Further Flexibility
• Suitable for Automotive ECU Burn-in/Endurance
Test Applications
• High Density Low Cost Solution, Bridging the Gap
Between Pickering’s Simpler Fault Insertion Modules &
More Complex FIBO BRIC Solutions
• Simulation of Various Types of Electrical Fault, Enabling
Rigorous Fault Testing
• 2A Hot or Cold Switching
• Switch up to 200VDC/140VAC and up to 60W Max Power
• VISA, IVI & Kernel Drivers Supplied for Windows
• Supported by PXI or LXI Chassis
• 3 Year Warranty
40-197-001 Fault Insertion Switch Schematic
with 34 channels and 4 fault buses.
U1
U2
M1
M2
U33
U34
M33
M34
Stimulus/Measurement Connections
UUT Connections
Fault Connections
F1A
F1B
F2A
F2B
F3A
F3B
F4A
F4B
Pickering’s Range of PXI Fault Insertion Switches
Model
No. Signal Channels Fault
Buses
Fault
Inputs
Max
Voltage
Max Current
or Bus Type
40-190B 74, 64 or 32 1 or 2 4 or 8 165V 2A
40-191A 6 2 2 40V 30A
40-192 6 2 2 200V 10A
40-193 7 1 or 2 1 or 2 16V 20A, 1A min
40-194 7 1 or 2 1 or 2 16V 20A, no min
40-195 22 or 11 pairs — 8 or 4 150V 1A
40-196 10 or 5 pairs — 10 or 5 110V 5A
40-197 34 or 16 4 8 300V 2A
40-198 20 1 or 2 3 or 6 250V 5A
40-199 10 1 or 2 2 250V 10A
40-200 4 or 8 differential 4 8 100V CAN, FlexRay
40-201 4 or 8 differential 2 4 100V Ethernet/AFDX
/BroadR-Reach
40-202 22 or 11 pairs — 22 or 11 150V 1A
The 40-197 is a 34 Channel Fault Insertion switch, primarily designed
for routing simulated fault conditions in automotive and aerospace
applications involving the reliability testing of safety critical controllers.
A low cost 16 Channel option is also available.
It is designed to be able to route different fault conditions between the
test xture and the equipment under test, including:
• Open-Circuit
• Short-Circuit between UUT connections
• Short-Circuit to other signals such as Power, Ignition & Ground via
fault buses
Through relays on each channel enable signals to be held open-
circuit. Four fault insertion buses allow channels to be shorted
together or to be connected to an external fault condition such as
power, ignition or ground.
For further exibility, each fault bus includes a changeover switch
to select one of two external fault conditions.
The default state of the unit is with all through relays closed and all
fault insertion relays open, giving an un-interrupted path between
the test xture and the equipment under test.