pickeringtest.com
PXI/PXIe 1000Base-T1 Fault Insertion Switch 40/42-203
ISSUE 1.2 MAY 2022
yAvailable as PXI or PXIe Modules
yFault Insertion on up to 6 Channels of 2 Wire
Connections
ySuited for 1000Base-T1/100Base-T1 Fault Insertion
yControlled Transmission Line Impedance
ySimple Insertion of Shorted Pair, Open and
Battery/Ground Connection
yVISA, IVI & Kernel Drivers Supplied for Windows
ySupported by PXI or LXI Chassis
y3 Year Warranty
Fault Connections
CH1 In
CH2 In
CH1 Out
CH2 Out
FB1 FB2
M1+
M1-
M2+
M2-
U1+
U1-
U2+
U2-
CH3 In
CH4 In
CH3 Out
CH4 Out
M3+
M3-
M4+
M4-
U3+
U3-
U4+
U4-
CH5 In
CH6 In
CH5 Out
CH6 Out
M5+
M5-
M6+
M6-
U5+
U5-
U6+
U6-
40/42-203-002 2-Wire, 6-Channel 1000Base-T1
Fault Insertion Switch Schematic Diagram
The 40-203 (PXI) and 42-203 (PXIe) are designed to simulate
common faults on high-speed two wire communication
interfaces such as 1000Base-T1. They support up to 6 channels
of two wire serial interfaces. Each channel pair can simulate
an open fault in either or both wires, and using the fault bus
switches can simulate short between both wires or a short to
one of two externally applied fault connections – such as battery
supply or ground - via two fault buses.
Each channel can carry up to 0.8 A and is rated up to 200 V
between wire pairs. The wire pairs have controlled transmission
line impedance suited to most differential signalling systems,
including high-speed 1000Base-T1, the fault buses are capable
of carrying 0.8 A and also have controlled transmission line
impedance. The front panel signal connectors are easy to use
MMCX which are fully supported by our range of connector
accessories. The module uses high quality reed relays designed
for high frequency application with a long service life.
Pickering’s Range of Fault Insertion Switches
Model No. Signal Channels Fault
Buses
Fault
Inputs
Max
Voltage
Max Current
or Bus Type
40-190B 74, 64 or 32 1 or 2 4 or 8 165 V 2 A
40-191A 6 2 2 40 V 30 A
40-192 6 2 2 200 V 10 A
40-193 7 1 or 2 1 or 2 16 V 20 A, 1 A min
40-194 7 1 or 2 1 or 2 16 V 20 A, no min
40-195 22 or 11 pairs — 8 or 4 150 V 1 A
40-196 10 or 5 pairs — 10 or 5 110 V 5 A
40-197A 34 or 16 4 8 300 V 2 A
40-198 20 1 or 2 3 or 6 250 V 5 A
40-199 10 1 or 2 2 250 V 10 A
40-200 4 or 8 differential 4 8 100 V CAN, FlexRay
40-201 4 or 8 differential 2 4 100 V Ethernet/AFDX
/BroadR-Reach
40-202 22 or 11 pairs — 22 or
11 150 V 1 A
40/42-203 3 or 6 differential 2 2 200 V 1000Base-T1
40/42-204 1 or 2 differential 2 2 200V 1000Base-T1
Differential Bus Switching
We also offer the 40-736 and 40-737 multiplexers
which are suitable for switching Ethernet, USB and
other serial communications signals.