PXI Avionics/Automotive 2A Fault Insertion Switch 40-202
ISSUE 1.4 DEC 2019
Supported by
eBIRST
eBIRST switching system test tools simplify switching system fault-
nding by quickly testing the system and graphically identifying the
faulty relay.
For more information go to: pickeringtest.com/ebirst
• 22 or 11 Fault Insertion Channels
• Suitable for Automotive or Avionics Test
Applications
• Multiple Channels Can Be Combined To Form
More Complex Networks
• High Density Low Cost Solution
• Simulation of Various Types of Electrical Fault,
Enabling Rigorous Fault Testing & Simulation
• 2A Hot or Cold Switching
• Switch up to 150 Volts DC with 60W Max Power
• VISA, IVI & Kernel Drivers Supplied for Windows
• Supported by PXI or LXI Chassis
• Supported by
eBIRST
™
• 3 Year Warranty
The 40-202 is a 22 or 11 Channel Fault Insertion Switch, primarily
designed for the simulation of fault conditions in automotive &
avionics applications involving the reliability testing of safety critical
controllers.
It is designed to be able to insert different fault conditions on pairs
of signals between the test xture and the equipment under test:
• Open-Circuit
• Short-Circuit between signal pairs
• Short-Circuit between signal pairs and user applied signals
such as Power or Ground.
Relays in-line with the signal paths allow open circuit conditions to
be simulated on either side or both sides of a signal pair. Relays
between each channel pair enable adjacent signals to be shorted,
and relays between signal paths and the “Fault” connection allow
the application of external fault conditions.
The switching topology of the 40-202 allows switching channels to
be interconnected so that complex fault insertion systems can be
constructed.
Pickering’s Range of PXI Fault Insertion Switches
Model
No. Signal Channels Fault
Buses
Fault
Inputs
Max
Voltage
Max Current
or Bus Type
40-190B 74, 64 or 32 1 or 2 4 or 8 165V 2A
40-191A 62 2 40V 30A
40-192 62 2 200V 10A
40-193 71 or 2 1 or 2 16V 20A, 1A min
40-194 71 or 2 1 or 2 16V 20A, no min
40-195 22 pairs or 11 pairs —8 or 4 150V 1A
40-196 10 pairs or 5 pairs —10 or 5 110V 5A
40-197A 34 or 16 48 300V 2A
40-198 20 1 or 2 3 or 6 250V 5A
40-199 10 1 or 2 2250V 10A
40-200 4 or 8 differential 48 100V CAN, FlexRay
40-201 4 or 8 differential 2 4 100V Ethernet/AFDX
/BroadR-Reach
40-202 22 pairs or 11 pairs —22 or 11 150V 2A
40-202 22-Channel
Fault Insertion Switch
Schematic Diagram
Note: Each channel has an
individual “Fault” input that can
be used to inject external fault
conditions.
In 2 Out 2
Fault 2
In 3 Out 3 In 22 Out 22
Channel 2 Channel 3 Channel 22
In 1 Out 1
Channel 1
40-202-001
External user applied fault conditions
Fault 1 Fault 3 Fault 22