Pinnacle Smart Thermostat User manual

Smart Thermostat User Guide
Easy Touch. Easy Warm.

02 www.underfloorshop.co.uk • 01284 339 669

04 Installation
05 Wiring Instructions
06 Wifi Connection
08 Thermostat Symbols
09 Start Up Wizard
10 Function & Operation
10 Temporary Override Temperature
10 Mode
10 Key-Lock
11 Menu
12 Clock
12 Event Setting
13 Readout
13 Advanced Setting
15 Open Window Detection
16 Troubleshooting
16 Dimensions
Contents

Introduction
The Pinnacle Smart Thermostat is an intuitive programmable thermostat which can be used to control either
electric or wet underfloor heating systems. It will keep your home at a comfortable temperature whilst minimising
energy use. Simply install the app on your smart phone to control your Pinnacle Smart thermostat remotely.
Technical Specifications
Supply Voltage: 85-265Vac 50/60Hz IP Class: IP21
Standby Power: < 1W/2W (WiFi version) Cable Specification: ≤2.5mm²
Max Load: 16A (Resistive)
Installation
Using your fingers, apply
firm pressure between
the thermostat front and
the outer frame at the
top, and pull towards you.
Connect the thermostat
according to the wiring
diagram.
Carefully click the display
module back in position.
04 www.underfloorshop.co.uk • 01284 339 669
1 2 3 4
Mount and reassemble
the thermostat. Secure
the thermostat to an
electrical wall box using
screws at either side of
the thermostat.

For installations in a bathroom or wet location where the thermostat cannot be installed within the room, please
select either floor sensor, remote air sensor or floor sensor and remote air sensor. A remote air sensor (room-out
sensor) can be purchased separately. All electric underfloor heating must use a floor sensor.
Wiring Instructions
Suggestion: Please keep the max load around 90% of 16A to prolong the lifetime.
FLOOR SENSOR FLOOR SENSOR
ROOM-OUT SENSOR

06 www.underfloorshop.co.uk • 01284 339 669
WiFi Connection
Step 1: Scan the QR code on the inside
cover of this User Guide for the app or
download the WARMME app from your
app provider.
Step 2: Create and account, then login
through the registered phone number or
email address.
Step 3: Click "Add Device"
followed by "Wifi Thermostat"
on the bottom of the screen.
Step 4: Check the thermostat WiFi
flag is fast flashing. If not,operate the
thermostat according to the APP tips
until it flashes quickly. Click the “Make
sure WiFi is flashing quickly” button.
If you experience a problem connecting, we're here to help. Contact us on 0800 056 0494 or email technic[email protected]o.uk

Step 5: Fill in the phone with
the WiFi network password,
click “confirm”.
Step 6: Click “Done” after the APP has connected
successfully to the thermostat.
Step 7: You can check the real-time temperature,
adjust or set the temperature, switch on/off or do
other operations on the main interface.
If you experience a problem connecting, we're here to help. Contact us on 0800 056 0494 or email [email protected]o.uk

08 www.underfloorshop.co.uk • 01284 339 669
Thermostat Symbols
Once the thermostat has been installed and connected to the electric supply, simply turn the thermostat on
using the Master On/Off switch on the side of the thermostat. Slide the switch down to turn on or up to turn off.
Room Temp WiFi
Event
Manual Mode
Actual Temp
Down Key
Floor Temp Day
Key-Lock
Office
On/Off Switch
Heat
Confirm Key
Set Clock
Frost Protection Mode
Home
Percent
Up Key
•Press the to confirm the selection.
•Press the and to select parameter.

There are 5 options:
•00 Floor sensor: run by floor sensor only
(default).
•01 Room-in sensor: uses the built-in
room sensor.
• 02 Room-in sensor and floor sensor: uses the
built-in sensor with floor temperature limit.
• 03 Room-out sensor: uses a remote air
sensor.
• 04 Room-out sensor and floor sensor: uses
a remote air sensor with floor temperature
limit.
* If the thermostat is connected to the WiFi, it
will update the time automatically.
The thermostat can operate in two timer modes, Home or Office.
The Home schedule has two heating periods and two off periods,
whereas the Office mode has one heating and one off period.
See Page 13 for the full schedule and the pre-programmed
times, which can be adjusted to suit.
If you choose room sensor and floor
sensor, floor temperature limit must
be set to protect floor.
Home Office
Clock
Floor Temperature Limit
Sensor Selection
Home or Office
Startup Wizard
Initial settings must be set when the unit is activated for the first time, this will ensure correct and efficient use of
your underfloor heating system.
Day Set Hour Set Minute Set
(If you choose both sensors)

10 www.underfloorshop.co.uk • 01284 339 669
Function & Operation
Temporary Override Temperature
Mode
Key-Lock
On the actual temperature interface, press the and to set temporary
override temperature. The temperature is only valid at the current event and it
will not be saved.
On the main display, Press the to select the mode.
There are 3 modes:
Auto mode: This is the default mode. The thermostat runs according to programmed
time events set in the Event Setting. It will show home if you choose, otherwise it will
show office.
Manual mode: Thermostat will run with the desired set temperature.
Anti-frozen mode: The thermostat will run with the low setting temperature until
changed, the maximum set temperature in this mode is 15°C.
Lock all keys to prevent the settings from being changed. On the actual temperature interface, press and hold
the and for 3 seconds at the same time to lock or unlock all of the keys.

Menu
On the main display, press and hold the for 3 seconds to enter menu.
------Sitemap of the menu
CLK
Set day and time Sensor
Selection
Used for heating
or cooling
Room
Temperature
Calibration
Adaptive
Function
Floor
Temperature
Calibration
Located in Home
or Office
Upper Floor
Temperature Limit Reset to
Factory Settings
Schedule
Selection
EVE
Set event’s
parameters
READ
Read heating
time of a
certain period
SET
Various settings
END
Back to actual
temp page
1 6
2 7
3 8
4 9
5

12 www.underfloorshop.co.uk • 01284 339 669
Clock
Event Setting
The default interface of the menu is CLK. Day and clock is set here.
Event setting is where you can program and change the times your heating is required. When in Auto Mode, the
thermostat switches the heating on and off in-line with the programmed times. On the clock interface, press
the or to select EVE (for event).
1. Press the to enter day setting.
2. Press the or to set day.
3. Press the to enter hour setting.
4. Press the or to set hour.
5. Press the to enter minute setting.
6. Press the or to set minute.
7. Press the to go back to the actual temperature interface.
* If the thermostat is WiFi version, it will update time automatically after connecting to WiFi.
1. Press the to enter day selection of event setting.
2. Press the or to select a day or end.
3. Press the to enter the event selection of the day, or back to the actual temperature interface if you select end.
4. Press the or to select an event.
5. Press the to select event’s start time.
6. Press the or to set the Hour of starting time.
7. Press the to enter the Minute setting.
8. Press the or to set the Minute of starting time.
9. Press the to enter the temperature setting.
10. Press the or to set the temperature.
11. Press the to back to the event selection, or back to day selection if the event is last one.
* If you want to go back to the actual temperature interface, you should go back to the day selection and select end.

Readout
Advanced Setting
Default Parameters
1. Count the heating time (in percent) within a certain period.
2. On the clock interface, press the or to select READ.
3. Press the to enter Readout, the interface will show the heating time of the previous day.
4. Press the or to select 1 day, 30 days, 365 days, it will show the heating time within the certain period.
5. Press the to back to the actual temperature interface.
1. The thermostat provides advanced settings to suit various special situations. These are normally set by technicians
during initial installation.
2. On the clock interface, press the or to select SET.
3. Press the to enter advanced setting.
4. Each setting can be accessed by pressing and parameters adjusted by pressing or .
Day (Wake) (Leave) (Back) (Sleep)
Home
Mon - Fri 06:00 20.0°C 08:30 15.0°C 17:00 20.0°C 23:00 15.0°C
Sat / Sun 06:00 20.0°C 08:30 20.0°C 17:00 20.0°C 23:00 15.0°C
Day (Wake) (Leave)
Office
Mon - Fri 07:00 20.0°C 18:00 15.0°C
Sat / Sun 07:00 15.0°C 18:00 15.0°C

14 www.underfloorshop.co.uk • 01284 339 669
Number Name Default Setting Options
1Sensor Selection 00: Floor Sensor
00: Floor Sensor
01: Room-In Sensor
02: 01+00
03: Room-Out Sensor
04: 03+00
2Room Temp Calibration 0.0°C 5.0°C — 5.0°C
3Floor Temp Calibration 0.0°C 5.0°C — 5.0°C
4Floor Temp Limit 35.0°C 20.0°C — 50.0°C
5Schedule 00: 7 00: 7
01: 5+1+1
6Used For 00: Heating 00: Heating
01: Cooling
7Adaptive Function 00: Adaptive 00: Adaptive
01: No
8Located In 00: Home 00: Home
01: Office
9Reset 00: No 00: No
01: Reset

Open Window Detection
1. Sensor selection:
There are 5 options:
00 Floor sensor: uses the floor sensor only (default).
01 Room-in sensor: uses the built-in room sensor.
02 Room-in sensor and floor sensor: uses the built-in sensor with floor temperature limit.
03 Room-out sensor: uses a remote air sensor.
04 Room-out sensor and floor sensor: uses a remote air sensor with floor temperature limit.
2. Room Temp Calibration: calibrate the temperature detected by room sensor.
3. Floor Temp Calibration: calibrate the temperature detected by floor sensor.
4. Floor Temp Limit: if you choose both sensors, floor temperature limit must be set to protect floor.
5. Schedule: Select a weekly schedule for the event.
There are 2 options
7: each day from Mon to Sun can be set individually.
5+1+1: 5 days from Mon to Fri have the same events, Sat and Sun can be set individually.
6. Used For: heating or cooling.
7. Adaptive Function: after several days of installation and use, Adaptive Function ensures that the required
temperature has already been reached when the next event begins.
8. Located In: Home or Office.
9. Reset: all parameters are restored to default values.
This function only works when either the room sensor or both sensors are selected (refer to 6.2). When this
function is activated, the thermostat will shut off automatically for 15 minutes should it detect a sudden fall in
temperature, for example when a window is opened.

Troubleshooting
E1: Room-in sensor error. E2: Floor sensor error. E4: Room-out sensor error.
Dimensions (mm)
16 www.underfloorshop.co.uk • 01284 339 669
Table of contents
Popular Thermostat manuals by other brands

Honeywell
Honeywell RCT8101 Quick installation guide

DELTA DORE
DELTA DORE Tybox 5701FP quick start guide

Carrier
Carrier DEBONAIR 33CS Installation, start-up, and operating instructions

Heat IQ
Heat IQ HIQ 425 User instructions

Vive
Vive TP-N-801 installation manual

United Electric Controls
United Electric Controls 55HT Series Installation and maintenance instructions

Vemer
Vemer Mithos Color Wi-Fi user manual

DELTA DORE
DELTA DORE TYBOX 5100 quick start guide

CLIMASET
CLIMASET Prossimo Series instruction manual

HOTOWELL
HOTOWELL HTW-21RT manual

RADEMACHER
RADEMACHER 9485 Instruction manual for the electrical connection and for commissioning

Danfoss
Danfoss GET B-RF Installation, commissioning and user instructions