Plymovent SPARKSHIELD User manual

www.plymovent.com
Cyclonic spark arrester
SPARKSHIELD
Installation and user manualEN

0507061510/010921/C SparkShield 1
PREFACE...................................................................................................................................2
1 INTRODUCTION..........................................................................................................2
2 PRODUCT DESCRIPTION .............................................................................................3
3 SAFETY ......................................................................................................................3
4 INSTALLATION ........................................................................................................... 4
5 MAINTENANCE ...........................................................................................................6
6 SPARE PARTS .............................................................................................................7
7 DISPOSAL ..................................................................................................................7
EN | ORIGINAL INSTRUCTION
All rights reserved. The information given in this document has been collected for the general convenience of our clients. It has been based on general data pertaining to construction
material properties and working methods known to us at the time of issue of the document and is therefore subject at any time to change or amendment and the right to change or amend
is hereby expressly reserved. The instructions in this publication only serve as a guideline for installation, use, maintenance and repair of the product mentioned on the cover page of this
document. This publication is to be used for the standard model of the product of the type given on the cover page. Thus the manufacturer cannot be held responsible for any damage
resulting from the application of this publication to the version actually delivered to you. This publication has been written with great care. However, the manufacturer cannot be held
responsible, either for any errors occurring in this publication or for their consequences.
To improve comprehension for people whose rst language is not English, we have written parts of this manual in Simplied Technical English (STE). STE is a controlled
language originally developed for aerospace industry maintenance manuals. It offers a carefully limited and standardized subset of English, along with specic writing rules.
TABLE OF CONTENTS

0507061510/010921/C SparkShield 2
PREFACE
Using this manual
This manual is intended to be used as a work of reference for
professional, well trained and authorised users to be able to
safely install, use, maintain and repair the product mentioned
on the cover of this document.
Pictograms and symbols
The following pictograms and symbols are used in this manual:
TIP
Suggestions and recommendations to simplify
carrying out tasks and actions.
ATTENTION
A remark with additional information for the user. A
remark brings possible problems to the user’s
attention.
CAUTION!
Procedures, if not carried out with the necessary
caution, could damage the product, the workshop or
the environment.
WARNING!
Procedures which, if not carried out with the
necessary caution, may damage the product or
cause serious personal injury.
WARNING!
Fire hazard! Important warning to prevent re.
Personal protective equipment (PPE)
Instruction to use respiratory protection when you
do service, maintenance and repair jobs. We
recommend to use a half-face respirator according
to EN 149:2001 + A1:2009, classe FFP3 (Directive
89/686/EEC).
Personal protective equipment (PPE)
Instruction to use protective gloves when you do
service, maintenance and repair jobs.
Text indicators
Listings indicated by “-” (hyphen) concern enumerations.
Listings indicated by “•” (bullet point) describe steps to
perform.
Service and technical support
For information about specic adjustments, maintenance or
repair jobs which are not dealt with in this manual, please
contact the supplier of the product. He will always be willing to
help you. Make sure you have the following specications at
hand:
- product name
- serial number
1 INTRODUCTION
1.1 General description
The SparkShield is a cyclonic spark arrester that is highly
eective on sparks and cigarette butts. Besides, it is a very
eective in-line pre separator to reduce dust load in the
connected lter system.
For an eective removal of cigarette butts, we
recommend an air velocity in the connected duct of
min. 11 m/s.
1.2 Product combinations
The SparkShield is part of Plymovent’s SHIELD re
safety solutions for prevention, detection and
suppression of re.
You can also use the SparkShield as separate spark arrester in
the extraction duct of central lter systems.
Refer to the available application data sheet for
possible product combinations.
1.3 Options and accessories
The following products are available as an option and/or
accessory:
General:
Inspection hatch IH-200/8 Ø 200 mm / 8 in.
Shut-o valve:
- MD-200 Ø 200 mm
- MD-8 Ø 8 in.
- EFC Industrial detergent
SparkShield-250 | 10:
- Inspection hatch IH-250/10 (2x) Ø 250 mm / 10 in.
SparkShield-400 | 16:
- Inspection hatch IH-400/16 (2x) Ø 400 mm / 16 in.
SparkShield-500 | 20:
- Inspection hatch IH-500/20 (2x) Ø 500 mm / 20 in.
SparkShield-630 | 24:
- Inspection hatch IH-630/24 (2x) Ø 630 mm / 24 in.
1.4 Technical specications
Material:
- housing (inlet + outlet) powder-coated steel
- cyclone SparkTwist galvanized steel
- dustbin tin
- hose spark resistant
glassbre/kevlar/metal
Weight (excl. dustbin):
- SparkShield-250 | 10 25 kg (55 lbs.)
- SparkShield-400 | 16 46 kg (101 lbs.)
- SparkShield-500 | 20 52 kg (115 lbs.)
- SparkShield-630 | 24 118 kg (260 lbs.)
Volume of dustbin 13 litres (± ½ CF)
25 litres (± ⅞ CF)
1.5 Dimensions
Refer to Fig. I on page 8.

0507061510/010921/C SparkShield 3
1.6 Pressure drop
Refer to Fig. II on page 9.
1.7 Working range
Refer to Fig. II on page 9.
Refer to the available product data sheet for
detailed product specications.
2 PRODUCT DESCRIPTION
2.1 Components
The product consists of the following main components and
elements:
Fig. 2.1
A Inlet
B Cyclone SparkTwist
C Duct clamp
D Outlet
E Dustbin cover incl. connection ange + hose
F Dustbin
Additionally for SparkShield-630 | 24:
G Lifting bracket
H Inspection & service hatch (2)
A B C
D
E
F
G
H
A B C
D
E
F
G
H
Fig. 2.1 Main components
2.2 Operation
The SparkShield consists of a horizontally mounted
in-line spark arrester with dustbin underneath. Due
to their weight, sparks and other debris are
separated from the airow by the cyclonic
SparkTwist and end up in the dustbin.
2.3 Options and accessories
2.3.1 Inspection hatches (recommended option)
The use of inspection hatches in the horizontal and vertical
duct (if any) allow visual spark arrester and duct inspection.
Fig. 2.2
A D
B B
CC E
A
FG
H
Inspection hatches
2.3.2 Shut-o valve (MD-200)
You can use a valve to shut o the vertical duct (if any) during
dustbin exchange.
Fig. 2.3
A Shut-o valve open
B Shut-o valve closed
Fig. 2.3
A B
Shut-o valve (open + closed)

0507061510/010921/C SparkShield 4
3 SAFETY
Intended use1
The product has been designed for removal of
sparks from metal and grinding processes. Using
the product for other purposes is considered
contrary to its intended use. The manufacturer accepts no
liability for any damage or injury resulting from such use. The
product has been built in accordance with state-of-the-art
standards and recognised safety regulations. Only use this
product when in technically perfect condition in accordance
with its intended use and the instructions explained in the user
manual.
Installation
- The installation of this product is exclusively reserved to well
authorised, trained and qualied engineers.
- Use sucient climbing gear and safety guards when working
on a higher level than 2 metres (local restrictions may
apply).
- Do not install the product in front of entrances and exits that
must be used for emergency services.
- Make sure the wall, ceiling or support system are strong
enough to carry the product.
Service, maintenance and repairs
- Obey the maintenance intervals given in this manual.
Overdue maintenance can lead to high costs for repair and
revisions and can render the guarantee null and void.
- Always use Personal Protective Equipment (PPE) to avoid
injury. This also applies for persons who enter the work area.
- Use sucient climbing gear and safety guards when working
on a higher level than 2 metres (local restrictions may
apply).
Personal protective equipment (PPE)
Wear respiratory protection and protective
gloves during service, maintenance and
repairs.
1. “Intended use” as explained in EN-ISO 12100-1 is the use for which the
technical product is suited as specied by the manufacturer, inclusive of his
directions in the sales brochure. In case of doubt it is the use which can be
deduced from the construction, the model and the function of the technical
product which is considered normal use. Operating the machine within the
limits of its intended use also involves observing the instructions in the user
manual.
4 INSTALLATION
4.1 Tools and requirements
You need the following materials to install the
product:
Duct >1 m Ø 200 mm/8 inch
(recommended)
Lifting and climbing gear; e.g.
- straps
- fork-lift truck + pallet
- scissor lift
Box spanner:
- SparkShield-250/10: M10 + M13
- SparkShield-400/16: M10 + M13
- SparkShield-500/20: M10 + M13 + M16
- SparkShield-630/24: M10 + M13 + M16
Duct support material
Electric drill + self-tapping screws
Existing duct:
- angle grinder; or
- jigsaw + electric drill
4.2 Unpacking
Make sure that the product is complete. The
package contains:
SparkShield-250 | 400 | 500 | 630:
- spark arrester, consisting of inlet with SparkTwist and outlet,
connected by duct clamp
- dustbin 13 litres
- dustbin 25 litres
- dustbin cover incl. connection ange + hose
For duct connection of the spark arrester:
- connection ring (2) Ø 250/400/500/630 mm
- duct clamp (2) Ø 250/400/500/630 mm
For connection of vertical duct Ø 200 mm (recommended)
between the spark arrester and the dustbin:
- connection ring (2) Ø 200 mm
- duct clamp Ø 200 mm
SparkShield-10 | 16 | 20 | 24:
- spark arrester, consisting of inlet with SparkTwist and outlet,
connected by duct clamp
- dustbin 13 litres (± ½ CF)
- dustbin 25 litres (± ⅞ CF)
- dustbin cover incl. connection ange + hose
For duct connection of the spark arrester:
reducer (2) from metric Ø 250/400/500/630 mm to imperial
- Ø 10/16/20/24 in.
- duct clamp (2) Ø 250/400/500/630 mm
For connection of vertical duct Ø 8 in. (recommended)
between the spark arrester and the dustbin:
- reducer (2) from metric Ø 200 mm to imperial Ø 8 in.
- duct clamp Ø 200 mm
If parts are missing or damaged, contact your supplier.

0507061510/010921/C SparkShield 5
4.3 Mounting
4.3.1 Spark arrester
You can mount the spark arrester:
- during installation of new ductwork
- afterwards in an existing duct2
ATTENTION
Allow sucient space between the duct and the wall
to install the spark arrester.
You can install the spark arrester as a whole. Lift it
with (e.g.):
- straps
- a forklift-truck with pallet
SparkShield-250 | 400 | 500 | 10 | 16 | 20:
When no lifting gear is available, we recommend to
install the inlet and outlet separately and to
reconnect them afterwards.
SparkShield-630 | 24:
You must install the spark arrester as a whole. It is
provided with a lifting bracket to facilitate various
lifting techniques.
To install the spark arrester, do the following.
ATTENTION
Obey the mounting instructions as indicated in:
- Fig. III (airow direction) and
- Fig. IV (duct installation) on page 6
• In case of installation in an existing duct: cut away a piece
of the existing duct. Refer to Fig. V on page 10 (D) for
the duct length to be removed.
• Support the loose ends of the duct.
WARNING
Duct supports must be able to carry the weight of
the spark arrester. Refer to paragraph 1.4 for the
weight of the spark arrester in question.
Fig. 4.1
• Extend all duct clamps.
• Slide a duct clamp Ø 250/400/500/630 mm over both duct
ends.
• Duct metric size (mm):
Place a connection ring Ø 250/400/500/630 mm (A) in
both duct ends and fasten them with self-tapping screws
(min. 6).
• Duct imperial size (inch):
Place a reducer metric-imperial Ø 10/16/20/24 in. (A) in
both duct ends and fasten them with self-tapping screws
(min. 6).
• Lift the spark arrester (C) in line with the duct and mount
it to the connection rings with the duct clamps (B). Tighten
the clamps with a box spanner.
2. The installation of any product(s) not included in the initial design of an
extraction system could add additional static pressure to the overall system
design. By doing so, the result may be a reduction of airow at the extraction
point.
Fig. 4.1
A
B
C
B
SparkShield-250/400/500
SparkShield-10/16/20
A
mm
mm
inch
inch
SparkShield-630
SparkShield-24
C
Mounting of the spark arrester
4.3.2 Dustbin
The SparkShield comes with two dierent dustbins. You can
install the preferred one.
Recommended use:
- SparkShield-250 | 400 | 10 | 16: dustbin 13 litres
- SparkShield-400 | 500 | 630 | 16 | 20 | 24: dustbin 25 litres
You can place the dustbin on the oor or on a frame or small
platform. It is recommended to enlarge the distance between
the spark arrester and the dustbin by a duct Ø 200 mm/8 in.
Although it is possible the install the dustbin directly
to the spark arrester, the installation of a vertical
duct of >1 metre between the spark arrester and
the dustbin enhances re safety. The larger the
distance to the dustbin, the safer.
For weight reasons we recommend to place the
dustbin on a small pallet to facilitate removal.
To install the dustbin, do the following.
WARNING
Due to the specic mass of sparks and other debris,
do not mount the dustbin in hanging position. This
goes for dustbin DB-13 and DB-25.

0507061510/010921/C SparkShield 6
Fig. 4.2
• Put the dustbin cover (B) on the dustbin of your choice and
connect it with the quick connect coupling (C).
Direct mounting to the spark arrester:
• Place the dustbin underneath the spark arrester.
• Connect it to the spark arrester with the duct clamp (A).
Tighten the clamp with a box spanner.
Fig. 4.2
A
B
B
C
B
A
C
D
inch mm
mm
inch
Mounting of the dustbin
In this case the following parts become redundant:
- connection ring (2) Ø 200 mm/8 inch
- duct clamp Ø 200 mm
Mounting via vertical duct Ø 200 mm/8 inch:
Fig. 4.3
• Duct metric size (mm):
Put a connection ring Ø 200 mm (B) at either side of the
duct and fasten them with self-tapping screws (min. 4).
• Duct imperial size (inch):
Put a reducer metric-imperial (B) at either side of the duct
and fasten them with self-tapping screws (min. 4).
• Connect the duct to the spark arrester with a duct clamp
(A). Tighten the clamp with a box spanner.
• Place the dustbin underneath the duct.
• Connect it to the duct with the duct clamp (C). Tighten the
clamp with a box spanner.
Fig. 4.3
A
B
B
C
B
A
C
D
inch mm
mm
inch
Mounting of the dustbin via a vertical duct
4.4 Inspection hatches (recommended option)
Refer to Fig. V on page 10 for the recommended position of
the inspection hatches.
• Make cut outs in the horizontal and/or vertical duct with
the mould supplied with the inspection hatches.
• Insert the hatches in the cut outs.
• Turn the handles 90° to fasten them and make the ducts
airtight.
Refer to the mounting instruction supplied with the
inspection hatches.
4.5 Shut-o valve (option)
You can install the shut-o valve in any appropriate position in
the vertical duct.
• Install the valve in accordance with the instruction sheet
supplied with the valve.
• Turn the handle in vertical position to open the valve.
5 MAINTENANCE
5.1 Periodic maintenance
The spark arrester as well as the dustbin require
periodic maintenance. You must learn from
experience how often this must take place, since the degree of
pollution strongly depends on the welding process and the
intensity of use.
Personal protective equipment (PPE)
Wear respiratory protection and protective
gloves during maintenance.
Maintenance frequency in the initial stage:
Component Action Frequency:
every X
weeks
X=1 X=2
Spark arrester Check for pollution. Clean if
necessary; refer to paragraph 5.2
X
Dustbin Check the level of contents. Replace
the dustbin if necessary; refer to
paragraph 5.3
X
5.2 Cleaning of spark arrester
ATTENTION
To avoid damage to the coating: do not use acid
base detergent.
Use one of the following materials to clean the spark arrester:
- high-pressure cleaner with hot water
- industrial detergent type EFC (supplied by Plymovent)
- industrial vacuum cleaner
- brush
- cleaning cloth with degreasing solvent
To clean the spark arrester, do the following.

0507061510/010921/C SparkShield 7
SparkShield-250 | 400 | 500 | 10 | 16 | 20:
• Support the spark arrester, preferably with straps.
• Demount the entire spark arrester by loosening the duct
clamps at both sides and bring it down.
• Disassemble the spark arrester.
• Clean the SparkTwist and the inlet + outlet of the housing
(inside).
• Assemble and install the spark arrester in reverse order.
SparkShield-630 | 24:
The spark arrester has a hatch for inspection and service
purposes on each side of the housing.
Fig. 5.1
• Open the front hatch (A).
Fig. 5.1
A
Inspection and service hatch
Fig. 5.2
• Remove the cotter pin from the axle.
Fig. 5.2 Cotter pin
Fig. 5.3
• Move the SparkTwist (A) to the hatch.
• Turn the SparkTwist (B) sectionwise and clean it.
Fig. 5.3
AB
Move + clean
• Move the SparkTwist back to the inlet.
• Attach it with the cotter pin.
• Close the hatch and fasten the draw latches.
5.3 Replacement of the dustbin
ATTENTION
The dustbins are disposable. To guarantee a
dust-free procedure we recommend not to empty
the dustbin but to dispose it of and to install a new
one.
The dustbin cover is provided with a exible hose to facilitate
replacement of the dustbin.
To replace the dustbin, do the following.
• Turn o the connected extraction fan.
Without shut-o valve:
• Loosen the quick connect coupling (ref. Fig. 4.2C) and take
the dustbin away.
• Close the dustbin with the lid that is supplied with the new
dustbin.
• Install a new dustbin and connect it in reverse order.
• Turn on the extraction fan.
• Dispose of the used dustbin in accordance with state or
local regulations.
With shut-o valve:
• Put the handle in horizontal position to close the shut-o
valve (ref. Fig. 2.3B).
• Loosen the quick connect coupling (ref. Fig. 4.2C) and take
the dustbin away.
• Close the dustbin with the lid that is supplied with the new
dustbin.
• Place a new dustbin and connect it in reverse order.
• Put the handle in vertical position to open the shut-o
valve (ref. Fig. 2.3A).
• Dispose of the used dustbin in accordance with state or
local regulations.
WARNING
Make sure that the handle of the shut-o valve is in
vertical position (=open) during use.
6 SPARE PARTS
The following spare parts are available for the lter
unit;
- refer to exploded view Fig. VI on page 10
7 DISPOSAL
After life of the product, dispose of it in accordance
with federal, state or local regulations.

0507061510/010921/C SparkShield 8
ANNEX
Fig. I Dimensions
SparkShield-250 | 400 | 500
SparkShield-10 | 16 | 20
SparkShield-630
SparkShield-24
®
SSA 250 super Spark Arrestor assembly
REV: 0
1 2 3
13
5
12
16
4
17
SSA 500 super Spark Arrestor assembly
REV: 0
9 1110
5
12
13
19
4
15
SSA 400 super Spark Arrestor assembly
REV: 0
6 7 8
5
12
13
18
4
14
SECTION B-B
C
C
SECTION C-C
The properties of the Details are
•
equel for all Models
The properties of the Section are
•
equel for all Models
19
- -
1 0102080320
Core SSA 500
900386A0018
0
18
-
1
-
0102080310
Core SSA 400
900386A0018
0
17 1
- -
0501062400 STI SSA 250
900386P0037
0
16 1
- -
0102080300
Core SSA 250
900386A0018
0
15
- -
1 0501062420 STI SSA 500
900386P0037
0
14
-
1
-
0501062410 STI SSA 400
900386P0037
0
13 1 1 1
Dustbin
900386A0006
0
12 1 1 1
SSA Dust Bin Connector
900386A0005
0
11
- -
1 0202971020
Outlet SSA 500
900386A0003
A
10
- -
1 0690020050
Clamp SSA Ø900
900386P0012
0
9
- -
1 0202970020
Inlet SSA 500
900386A0002
A
8
-
1
-
0202971010
Outlet SSA 400
900386A0003
A
7
-
1
-
0690020040
Clamp SSA Ø710
900386P0012
0
6
-
1
-
0202970010
Inlet SSA 400
900386A0002
A
5 1 1 1 0690020000
Clamp SSA Ø200
900386P0012
0
4 1 1 1 0601020770
DIN 933 (M8X80) DIN 933 (M8X80)
0
3 1
- -
0202971000
Outlet SSA 250
900386A0003
A
2 1
- -
0690020030
Clamp SSA Ø500
900386P0012
0
1 1
- -
0202970000
SSA 250 Inlet assembly
900386A0002
A
POS
SSA 250 super
Spark Arrestor
assembly/Qty.
SSA 400 super
Spark Arrestor
assembly/QTY.
SSA 500 super
Spark Arrestor
assembly/QTY.
Euromate_ArtNo
DESCRIPTION
Drawing Number
Rev.
1800 GJ Alkmaar
The Netherlands
GENERAL TOLERANCES ACC. TO ISO 2768 - mK
T: +31-(0)72-5640604
F: +31-(0)72-5644469
TREATMENT:
Plymovent Group BV
P.O. Box 9350
Plymovent Netherlands article number:
DESIGN DATE :
VOLUME:
MATERIAL :
WEIGHT:
ENGINEER :
1 OF 1
mm
1:10
SCALE:
Approved By:
Last Revision text:
:
Plymovent Sweden article number:
0
Creation Date:
RFC:
Revision:
DOCUMENT STATUS: CHECKED_IN
3RD ANGLE PROJECTION
Approval Date:
Designed By:
SURFACE ROUGHNESS ACC. TO ISO 1302 - N9
06-07-10
KV
The information contained in this drawing is the sole
property of Plymovent BV. Any reproduction in part
or as a whole without written permission of
Plymovent BV is prohibited.
7165365.73 mm³
52358.71 g
UNITS:
SHEETSIZE
SHEET :
05-07-10
DESCRIPTION:
Revision
Drawing number:
A1
SSA Super Spark Arrestor assembly
0
900386A0001
KV
D
B
G
BA
C
E
F
B
G
H
D
B
A
C
EF
SparkShield-
250 10 400 16 500 20 630 24
mm inch mm inch mm inch mm inch
AØ 500 Ø 19⅝ Ø 710 Ø 28 Ø 900 Ø 35⅜ Ø 1125 Ø 44¼
BØ 250 Ø 9⅞ Ø 400 Ø 15¾ Ø 500 Ø 19⅝ Ø 630 Ø 24¾
Cmin. 825 min. 32½ min. 970 min. 38 min. 1095 min. 43 min. 1200 min. 47
D433 17 558 22 654 25¾ 770 30⅜
Emin. 1050 min. 41½ min. 1200 min. 47 min. 1325 min. 52 min. 1420 min. 56
FØ 200 Ø 7⅞ Ø 200 Ø 7⅞ Ø 200 Ø 7⅞ Ø 200 Ø 7⅞
G345 13⅝ 385 15⅛ 505 19⅞ 630 24¾
H616 24¼ 866 34⅛ 1086 42¾ 1300 51⅛
I- - - - - - 1590 62⅝
J- - - - - - 330 13
K- - - - - - 675 26⅝

0507061510/010921/C SparkShield 9
ANNEX
Fig. II Pressure drop
PRESSURE DROP & WORKING RANGE SparkShield-
250 400 500 630
10 16 20 24
Pressure drop
Working range
(max. 800 Pa / 3 in. WG)
0
200
400
600
800
1000
1200
1400
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000
Volume d’air (m
3
/h)
Perte de charge (Pa)
Perte de charge (pouces colonne d’eau)
500 1000 1500 2000
1
2
3
4
5
2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000
Volume d’air (pc/min.)
0
200
400
600
800
1000
1200
1400
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000
Cantidad de aire (m
3
/h)
Caída de presión (Pa)
0
200
400
600
800
1000
1200
1400
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000
Luftflöde (m
3
/h)
Tryckfall (Pa)
Caída de presión (pulgadas columna de agua)
500 1000 1500 2000
1
2
3
4
5
2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000
Cantidad de aire (pies cúbicos/min.)
0
200
400
600
800
1000
1200
1400
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000
Luchtstroom (m
3
/h)
Drukval (Pa)
0
200
400
600
800
1000
1200
1400
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000
Luftvolumen (m
3
/h)
Druckverlust (Pa)
0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 16000 18000 20000 22000
Airflow (m³/h)
200
400
600
800
1000
1200
1400
Pressure drop (Pa)
Pressure drop (in. WG)
1
2
3
4
5
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000 9000 10000 11000 12000 13000 14000
24000
Airflow (CFM)
Airflow (m³/h)
2400020000 4000 6000 8000 10000 12000 14000 20000 2200016000 18000 26000 28000 30000 32000 34000 36000 38000 40000
200
400
600
800
1000
1200
1400
Pressure drop (Pa)
1
2
3
4
5
0
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000 9000 10000 11000 12000 13000 14000
Airflow (CFM)
SparkShield-250 | 10
SparkShield-400 | 16
SparkShield-500 | 20 SparkShield-630 | 24
Fig. III Mounting instructions | airow direction
Airow direction
Fig. IV Mounting instructions | duct installation
Perpendicular without bend(s)

0507061510/010921/C SparkShield 10
ANNEX
Fig. V Mounting instructions | installation in an existing duct
A D
B B
CC E
A
FG
H
mm inch
Amin. 1000 min. 40
B± 175 ± 7
C± 250 ± 10
D
SparkShield-250 800 31½
SparkShield-400 970 38¼
SparkShield-500 1180 46½
SparkShield-630 1420 55⅞
SparkShield-10 915 36
SparkShield-16 1085 42¾
SparkShield-20 1295 51
SparkShield-24 1535 60⅜
E± 150 ± 6 F| G| HInspection hatches
Fig. VI Spare parts
9824000300 (1)
9824000310 (5)
9824000400 (1)
9824000410 (5)
0000103074 SparkTwist
0000103081
0000103082
0000103083
0000103084
0690020040
0690020050
Article no. Description
9824000300 DB 13 | Dustbin 13 litres
9824000310 DB 13 | Dustbin 13 litres (5 pcs)
9824000400 DB 25 | Dustbin 25 litres
9824000410 DB 25 | Dustbin 25 litres (5 pcs)
0000103074 Dustbin cover incl. connection ange + hose
0000103081 Duct clamp Ø 200 mm/8 inch
0000103082 Duct clamp Ø 250 mm/10 inch
0000103083 Duct clamp Ø 400 mm/16 inch
Article no. Description
0000103084 Duct clamp Ø 500 mm/20 inch / housing
SparkShield-250 | 10
0690020040 Duct clamp housing SparkShield-400 | 16
0690020050 Duct clamp housing SparkShield-500 | 20
on request SparkTwist-250 | 400 | 500 | 630

www.plymovent.com
0507061510/010921/C SparkShield
Table of contents
Other Plymovent Welding Accessories manuals
Popular Welding Accessories manuals by other brands

Harbor Freight Tools
Harbor Freight Tools 43615 Assembly and operating instructions

Amada
Amada WELTOUCH CT-110E Operation manual

Chicago Electric
Chicago Electric 94739 Assembly and Assembly and operating instructions

GYS
GYS ERGOTECH LCD 5.9 TRUE COLOR instructions

Leister
Leister Welding-Pen A operating instructions

RUD
RUD PowerPoint WPP Series Translation of the original instructions