PREPARATION FOR USE
• Unscrew the patented safety cap (B) and fill
the boiler with about 2 litres of water using
the filler bottle (7) making sure that it does
not overflow (Fig 1).
WARNING: When filling a hot boiler, we
recommend adding small amounts of
water to avoid the water evaporating in-
stantly with the risk of burning.
This appliance has been designed to work
with normal tap water.
However, since water contains limescale by
nature, which may cause scaling in the long
run, we recommend using a mixture of 50%
tap water and 50% demineralised water or
treated with water softener systems. To use
tap water only and avoid scale formation,
we recommend the addition of the special
natural scale removal agent Kalstop
FP2003.
Absolutely do not use distilled water,
dryer condensate water, perfumed wa-
ter, rain water, battery water, water from
air conditioning systems and the like. Do
not use chemical substances or deter-
gents.
• Carefully screw on the safety cap to hand
tight (Fig. 2). Make sure the patented safety
cap (B) is fully and correctly screwed on,
otherwise you may experience steam esca-
ping from around the cap. In this case turn
off the appliance, unplug it from the mains
and wait for it to cool before screwing the
cap back on.
• Connect the power supply cable (I) into an
earthed power supply of the correct vol-
tage.
NOTE: when filling, make sure that the water
does not overflow, to avoid wetting the sur-
face on which your Cimex Eradicator is re-
sting.
WARNING: Never leave the filling bottle or
the funnel resting on the mouth of the boi-
ler, with the product connected to the
power supply, since this could cause
burns.
INSTRUCTIONS FOR USE
• Press down the generator on/off switch (F)
and the accessories on/off switch (A) wich
will light up together with the pressure indi-
cator light (G).
• Wait until the steam pressure indicator light
(G) goes out. Cimex Eradicator is now ready
for use.
• Open the cover of the central connector
block (P) and insert the central connector
(R) pressing the connector button (S) and
taking care that the locking tab (Q) is cor-
rectly positioned in the lock-in aperture (U)
on the block (Fig. 3).
• Unscrew the cap of the disposable bottle
(2) (Fig. 5).
• Insert the stopper (3) into the disposable
bottle (fig. 6), until it rests on the base of the
bottle, ensuring that it stays as straight as
possible (Fig. 7).
• Screw the bottle into the bottle fitting, taking
care to ensure that the stopper enters the
hole inside the fitting perfectly, without ben-
ding (Fig. 8).
WARNINGS:
•Do not screw the bottle to the gun
without the stopper.
•If no consumption of HPMED is seen du-
ring use of the product, this means that
the stopper has not been inserted correc-
tly, or has folded within the bottle.
Unscrew the bottle and repeat the inser-
tion procedure, taking care to position it
correctly.
• Do not refill the disposable bottle.
• Wait until the heating lamp (L) turns off.
• Adjust the steam flow by turning the knob
(D) to medium. (see “Steam flow adjust-
ment” section).
• Press the steam delivery push-button (K)
so that steam will be delivered through the
delivery device.
Note:
• The handle is fitted with a safety switch (J)
to prevent the accidental activation of
steam delivery by children or people
ENGLISH
20
CIMEX ERADICATOR
VT CIMEX ERADICATOR -1U01 PRELIMINARE 2014_ver7:VT 2300 M0S05357 1L05 08/04/2014 13.57 Pagina 20