manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Polycom
  6. •
  7. Server
  8. •
  9. Polycom RealPresence RMX 1800 Datasheet

Polycom RealPresence RMX 1800 Datasheet

Installation Quick Start Guide for RealPresence
Collaboration Server (RMX)1800
Basic Setup Connecting the Cables to the RealPresence Collaboration Server 1800
System
1Insert the power cable into the power connector on the rear panel of the system.
2Connect the Management Network cable to LAN 1 port.
3Connect the media and signaling cable to LAN 2 port
4For systems that have three DSP media cards, connect E1/T1 cables to the PRI ports
also.
Configuring the LAN Properties on the USB Key
1Insert the USB key provided with your system into the PC workstation.
The Polycom RealPresence Collaboration Server(RMX) Documentation Library
&
Initial
Setup Tools window opens.
aSelect Open Folder to view files using Windows Explorer.
bDouble-click the index.hta file.
2Select the documentation language. from the language window.
3In the Polycom End User License Agreement window, click the Accept Agreement
button.
4In the Product Type Selection
window, click the RealPresence Collaboration Server
1800 hyperlink.
5Click LAN Configuration Utility.
The LAN Configuration Utility dialog box opens.
6Modify the parameters in the utility’s dialog box using the information supplied by
your network administrator.
7Click OK.
8Remove the USB key from the PC.
First-time Power-up and Connection to MCU
1Insert the USB key containing the modified IP addresses into either of the USB
ports on the RealPresence Collaboration Server 1800 system’s back panel
The following graphic illustrates RealPresence Collaboration Server 1800 systems
with three DSP media cards. Other systems don’t have PRI ports..
2Power the system ON.
The PWR LED is lit. System power-up sequence may take approximately five
minutes.
3In your network browser, enter the IP address of the RealPresence Collaboration
Server 1800 system’s Control Unit and press Enter.
4After the Welcome screen is displayed, remove the USB key from the system.
5.
Before installing the system and performing the basic setup, please read the
Important Safeguards described in the Polycom RealPresence Collaboration
Server 1800 Hardware Guide.
For detailed description of unpacking and rack mounting instructions, see
the Polycom RealPresence Collaboration Server 1800 Hardware Guide.
Button/LED Description
ON/OFF button Power the RealPresence Collaboration Server 1800 System on or off
LAN 1 LED Off - No network connection
Green - Network connected
Flickering green - In use
LAN 2 LED Off - No network connection
Green - Network connected
Flickering green - In use
STATUS LED
Red - System alarms
Green - Endpoints are connected to a meeting
Flickering green - No system alarms and no endpoints connected to the
meeting
Flickering blue - Diagnostic tests are running
Blue - Diagnostic tests are completed. Remove the USB key (if applicable)
and restart the system
M/S LED
Blue - System upgrade completed, waiting for reboot
Flickering blue - System upgrading in progress
Green - The system works normally, either in single mode, or as the
master MCU in the hot backup mode
Flickering green - The system works normally, as the slave MCU in the hot
backup mode
M/S LED PWR LED
ON/OFF button
LAN 2 LED
LAN1 LED
STATUS LED
PWR LED Green - Power normal
Red - Power alarms
Button/LED Description
LAN 2
Built-in
powersocket
and fan
RS232 USB 2
USB 1 LAN 1
Click Login.
Enter POLYCOM.
Enter POLYCOM.
Click Polycom Resource
Center and follow the on screen
instructions to obtain the Product
Activation Key.
Enter or paste the Product
Activation Key obtained.
Click OK.
Accept the license
agreement
RealPresence® Collaboration Server (RMX®)1800
11725-74861-000A
Polycom Moscow
T +7-495-924-25-25
[email protected]
www.polycom-moscow.ru
Initial System Configuration
This section describes the definition of H.323 Network Service, setting the RMX time,
modifying the default Administrator user and setting basic system flags. For detailed
description of H.323, SIP and ISDN Network Service definitions, see the RealPresence
Collaboration Server (RMX) 1800/2000/4000 Getting Started Guide, “First Time Installation
and Configuration”.
>> In the Fast Configuration Wizard, select Next to move from one window to another.
1Configure signaling and media network IP address.
2Configure the router for signaling and media network.
3Configure DNS settings.
4In the Network Type tab, IP Network Type field, select H.323 and click Next.
5
6
7Click the Save & Continue button. In the IP Network Service creation confirmation
window, click OK.
8
9
10
11 Click Save & Close.
12 In the Success Message box confirming successful configuration, click OK.
13 In the Reset Confirmation dialog box, click Yes.
14 In the Please wait for system reset message box, click OK.
System restart may take up to 10 minutes.
15 Refresh the browser periodically until the Login screen is displayed and Login.
In the Main Screen an MCU State indicator displays the time remaining until the
system start-up is complete.
When the default system User is replaced and the system Time is set and if there are
no System Errors, the green STATUS LED on the system’s front panel turns ON.
Connecting to a Conference Directly or via Entry
Queue
The RMX is shipped with pre-configured default conferencing entities that can be used
to dial in and start conferences. Default (Transit) Entry Queue ID: 1000, default Meeting
Room IDs: 1001, 1002, 1003, and 1004.
H.323 Participants
Dial: [MCU Prefix in Gatekeeper][Conference or Entry Queue ID/Name]
For example, if the MCU prefix in the gatekeeper is 925, enter 925 or 9251000 to connect
to the EQ or 9251001/2/3/4 to connect directly to the conference. When connected to
the EQ, enter the destination Meeting Room ID (i.e. 1001, 1002, 1003 or 1004).
Alternatively, use the EQ or conference name. For example, if the conference name is
Maple_Room, the participant can dial: 925Maple_Room.
SIP Participants
Dial: conference_routing _name@domain_name. Conference routing name must be
registered with the SIP server. For example, enter 1001@polycom.com if conference
routing name is 1001 and the domain name is polycom.com.
Conference Control Using DTMF Codes
IPv4 is the default protocol for setting the IP Network Service in the Fast Configuration
Wizard.
Change the default service name
if required.
Signalling host IP address is the
same as the media IP address.
Enter the media network IP
address
Enter the subnet mask for the
signaling and media network.
Enter the router address of the
signaling and media network.
Enter the name of the MCU on
the network.
Select whether to enable DNS
service.
Optional. Define the DNS server
properties:
•Registration mode
•The name of the MCU
domain
•The static IP address of the
primary DNS server
Enter the name of the MCU on
the network service.
Select Specify to configure the
gatekeeper parameters.
Enter gatekeeper’s host name
or IP address.
Enter the string with which the
MCU registers itself with the
gatekeeper.
Enter the alias that identifies
the RMX’s Signaling Host within
the network. Up to five aliases
can be defined for each RMX.
Select this check box only if the
authentication is enabled on the
gatekeeper, to enable the
Collaboration Server to register
with the gatekeeper. Otherwise,
skip this tab.
Enter the user name and
password the Collaboration
Server will use to authenticate
itself with the gatekeeper. The
name and password must be
defined in the gatekeeper.
Option 1: Using the arrows, set
the GMT Time on the RMX.
Using the arrows, set the time
zone difference between
Greenwich and the RMX’s
physical location.
Option 2: Click to automatically
update the RMX's GMT Date,
Time and Offset to match that of
the workstation.
Option 3: Select this check box
to synchronize RMX time with up
to three external NTP servers
and enter their IP addresses.
Enter the new user name of the
new administrator user.
Enter the password for the new
administrator user.
Enter the new password again
to confirm the new password.
Optional. Modify the default
settings of the system flags
that define the general
system behavior such as the
number of digits in the
conference ID assigned by
the MCU.
These flags can be modified
later, if required, by clicking
Setup menu > System
Configuration.
Operation DTMF String
Mute My Line *6
Unmute My Line #6
Play Help Menu *83
Change To Chairperson *78
Request private assistance *0
Request assistance for conference 00
21725-74861-000A
RealPresence® Collaboration Server (RMX®) 1800

Other Polycom Server manuals

Polycom DOC2557A Installation instructions

Polycom

Polycom DOC2557A Installation instructions

Polycom KIRK KWS8000 User manual

Polycom

Polycom KIRK KWS8000 User manual

Polycom DOC2709A Installation instructions

Polycom

Polycom DOC2709A Installation instructions

Polycom RealPresence RMX 1500 Service manual

Polycom

Polycom RealPresence RMX 1500 Service manual

Polycom Real-Time Media Conferencing Platform RMX... Datasheet

Polycom

Polycom Real-Time Media Conferencing Platform RMX... Datasheet

Polycom KIRK 600v3 User manual

Polycom

Polycom KIRK 600v3 User manual

Polycom SpectraLink 1725-36033-001 Instruction Manual

Polycom

Polycom SpectraLink 1725-36033-001 Instruction Manual

Polycom RSS 2000 User manual

Polycom

Polycom RSS 2000 User manual

Polycom SpectraLink 1725-36032-001 Instruction Manual

Polycom

Polycom SpectraLink 1725-36032-001 Instruction Manual

Polycom realpresence 1800 Installation instructions

Polycom

Polycom realpresence 1800 Installation instructions

Polycom KIRK 2500 User manual

Polycom

Polycom KIRK 2500 User manual

Polycom DOC2558A Installation instructions

Polycom

Polycom DOC2558A Installation instructions

Polycom RSS 2000 V1.0 User manual

Polycom

Polycom RSS 2000 V1.0 User manual

Polycom DOC2557B Installation instructions

Polycom

Polycom DOC2557B Installation instructions

Polycom DOC2558B Installation instructions

Polycom

Polycom DOC2558B Installation instructions

Polycom DMA 7000 User manual

Polycom

Polycom DMA 7000 User manual

Polycom RSS 2000 User manual

Polycom

Polycom RSS 2000 User manual

Polycom DOC2559C Installation instructions

Polycom

Polycom DOC2559C Installation instructions

Polycom RSS 2000 User manual

Polycom

Polycom RSS 2000 User manual

Polycom Collaboration Server (RMX) 1500 Quick reference guide

Polycom

Polycom Collaboration Server (RMX) 1500 Quick reference guide

Polycom KIRK 300 Operator's manual

Polycom

Polycom KIRK 300 Operator's manual

Polycom Realpresence collaboration server 1500 Service manual

Polycom

Polycom Realpresence collaboration server 1500 Service manual

Polycom RMX 1500 Installation instructions

Polycom

Polycom RMX 1500 Installation instructions

Polycom DOC2559B Installation instructions

Polycom

Polycom DOC2559B Installation instructions

Popular Server manuals by other brands

Planet ICS-2200T Quick installation guide

Planet

Planet ICS-2200T Quick installation guide

Avtech AVC733 user manual

Avtech

Avtech AVC733 user manual

Black Box LWS401A quick start guide

Black Box

Black Box LWS401A quick start guide

FrontRow DRS5000 Setup guide

FrontRow

FrontRow DRS5000 Setup guide

Multitech MultiModem iSMS SF100-G User guide for system administrators

Multitech

Multitech MultiModem iSMS SF100-G User guide for system administrators

Tripp Lite USB Device Server US-4A Specification sheet

Tripp Lite

Tripp Lite USB Device Server US-4A Specification sheet

IPEX PH485Ex2 user manual

IPEX

IPEX PH485Ex2 user manual

Multitech PROXYSERVER MTPSR1-120 user guide

Multitech

Multitech PROXYSERVER MTPSR1-120 user guide

Planet 1-Bay SATA NAS Server NAS-7100 Quick installation guide

Planet

Planet 1-Bay SATA NAS Server NAS-7100 Quick installation guide

HIK VISION DS-IE1032-03U/BA quick start guide

HIK VISION

HIK VISION DS-IE1032-03U/BA quick start guide

Oracle netra X5-2 installation guide

Oracle

Oracle netra X5-2 installation guide

AirLive MU-5000FS user manual

AirLive

AirLive MU-5000FS user manual

Blackbe;rry Enterprise Server 4.1 manual

Blackbe;rry

Blackbe;rry Enterprise Server 4.1 manual

Black Box 37687 user and administration guide

Black Box

Black Box 37687 user and administration guide

Multitech SocketWireless MT800SWM reference guide

Multitech

Multitech SocketWireless MT800SWM reference guide

Blackbe;rry ENTERPRISE SERVER FOR IBM LOTUS DOMINO Upgrade guide

Blackbe;rry

Blackbe;rry ENTERPRISE SERVER FOR IBM LOTUS DOMINO Upgrade guide

Santec SVS-1001 Quick installation guide

Santec

Santec SVS-1001 Quick installation guide

Cayin CMS-SE quick start guide

Cayin

Cayin CMS-SE quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.