High vacuum pumps, exhausters and blowers operating manual
WARNING
The lack of the overpressure/depression valve can cause serious damages, the valve must be installed next to
the machine flanges without the interposition of non return valve.
3.1.2 - EXHAUSTERS –AC EXHAUSTERS
Exhausters are pumps operating without oil inside the hydraulic chambers. They include the centrifugal-volumetric
blowers series, from size 73 to size 103 and the volumetric series from size 163 to size 883. They are intended to be
used as a component of a more complex system that processes clean air or not aggressive/explosive gases. They are
suitable to operate with positive back pressure in delivery, pressure Max 1 bar(g), or negative in suction, depression Max
–0,5 bar(g), within the permitted temperature limits. The temperature at suction inlet must be from 12 to 40 ° C.
For more information about features and performance of pumps, please refer to the available documentation.
They can be run by belt through a pulley mounted overhanging on the shaft or direct with flexible coupling.
3.1.3 –HIGH VACUUM PUMPS, BOOSTER HV e FP SERIES
The high vacuum centrifugal-volumetric pumps , from size 103 to size 1083 described in this manual, are pumps operating
without oil inside the hydraulic chambers. They are intended to be used as a component of a more complex system that
processes clean air or not aggressive/explosive gases and small quantities of water vapors. They are suitable to operate
in series upstream of a primary vacuum pump in order to improve the reachable vacuum, or rather to accelerate the
attainment. For the HV series, the lowest attainable pressure is 0.01 mbar (a).
The FP series is optimized for the food packaging and can reach a pressure of 0.5 mbar (a).
The applications must remain within the limits of permissible suction temperature from 12 to 40 ° C.
Pompetravaini- BORA can provide vacuum systems composed by a vacuum volumetric pump in combination with a liquid
ring vacuum pump with Hydrotwin system series.
They can be run by flexible coupling with coupling insert.
3.2 - INTENTED USE AND CONTRAINDICATIONS
3.2.1 - INTENTED USE
The volumetric pumps described in this manual are intended to be used as components of a more complex system
that works with clean air, inert gas or small amounts of water vapor in the low and medium vacuum, or in low pressure.
The pump transfers a gas from the suction-inlet to the blowing-outlet with a delivery consistent with the characteristic
performance curve applicable for each size/version in the machines available range.
The temperature at suction inlet must be from 12 to 40 ° C
Any other use is prohibited. The Supplier is not liable for any damage to persons and/or property caused by improper
use of the pump..
3.2.2 –CONTRAINDICATIONS
Any use other than that for which the pump was constructed is to be considered an abnormal
condition and therefore can cause damage to the pump and pose a serious danger to the operator.
Below is a series of operations involving improper use of the pump, which are not permitted under any circumstance.
•Do not use the pump in non-industrial installations unless all necessary precautions and protective measures
have been taken (e.g. protection against contact for child safety).
•Do not use the pump in conditions other than those indicated in the tables shown in point 3.3 of this manual.
•Do not operate the pump Booster, HV/FP if the priming pressure has not been reached.
•Do not use the pump in an explosive (classified areas according to ATEX 94/9 CE Directive) or aggressive atmosphere
or in an atmosphere with a high concentration of dust or oily substances and do not use it to pump explosive, flammable
or corrosive gases or gases that form particles. The pumps in the standard version are not suitable for evacuating
oxygen at higher concentrations than that of atmospheric concentrations. Using the pump in these atmospheres and
with these types of gases can cause injury, explosion, fire or seriously damage the pump.
•Do not use the pump without installing an intake filter suitable for the applications for which it has been intended.
•Do not change or transform the pump, carry out repair or maintenance work of your own initiative. Maintenance work
can only be carried out in compliance with Maintenance chapter of this manual.
•Only use original spare parts or parts provided by the Supplier.
•Do not use the pump to pump solid materials, chemicals, powders, solvents or other substances differing from those
permitted. These kinds of materials may damage the unit, limit its performance or reduce its lifespan.
•Do not expose the pump to rain, steam, excessive humidity or direct sunlight.
•Do not install the pump in places subject to possible flooding.
•Do not place or store near flammable or combustible materials or substances.
•Do not open oil fill or drain plug while pump is working.