INSTALLATION INSTRUCTIONS
The “Quietline” Pump has been designed to work with a variety of lter types
including Sand, Cartridge and Diatomaceous Earth.
The installation of the Quietline Pump should be carried out by an experienced Pool
Plumbing, Pump and Filter Installer.
LOCATION
1. Install at a distance no more than 12 metres from the Pool or Spa and no more
than 1 metre above water level or 1 metre below water level. If the pool is to
be installed outside these parameters, seek the advice of your local Poolrite
Distributor.
2. The Pump should be placed on a secure and level concrete or similar base 600
x 300mm in size (Pump only) and should be placed in a location that cannot be
ooded by storm water or by accidental immersion.
3. The rear of the Motor should be no closer than 150mm from a wall, fence or any
other barrier to allow for adequate airow to cool the Motor.
PIPE CONNECTION
4. The Suction and Discharge Ports are provided with Union Adaptors for quick
disconnection. These connectors will accept either 40mm or 50mm PVC pipe and
should be joined to the pipe with PVC Solvent Cement. Suction lines should be no
smaller than as follows:-
Pump Model Max Suction Line Length Min. PVC pipe size
SQI 400 12m 50mm
SQI 500 12m 50mm
SQI 600 12m 50mm
SQI 700 12m 2 x 50mm
Discharge pipe should be no smaller than 40mm for Pump sizes SQI 400, SQI 500
and SQI 600. Pump SQI 700 should use 50mm pipe.
When installed below water level, Shut-off Valves should be tted to the Suction and
Discharge Lines which should be free from air leaks. The discharge from the Pump
Outlet should be connected to the Inlet of the Filter and the Suction Port connected to
the Skimmer Box or Suction Outlet from the Pool or Spa.
WEATHER PROTECTION
5. The Quietline Pump is completely Weatherproof and therefore no enclosure is
necessary. However should it be desirable to install the Pump in an enclosure, the
enclosure must have both a ventilation inlet and outlet opening to allow cooling
airow around the Pump Motor. Each opening should be at least 200 sq cm in
area as close as practicable to the Pump.
POWER CONNECTION
6. The Quietline Pump is designed to be connected to a nominal 240 volt
50Hz power supply and is supplied with a 1.8 metre lead and 3 Pin Plug. A
Weatherproof 3 Pin Power Point should be tted by an electrician in a dry place,
shielded from pool water splash over.
EXTENSION LEADS ARE NOT RECOMMENDED FOR USE WITH THIS EQUIPMENT
BECAUSE THEY ARE UNSAFE IN AND AROUND THE POOL ZONE.
OPERATING INSTRUCTIONS
STARTING PUMP
Before switching the pump ON check that all Pipework is properly sealed and that the
pool water is at the recommended level (check with your Pool Builder).
1. First prime the Pump by removing the Clear Lid by loosening the Clamp Knobs
and allowing them to swing aside.
Fill the Strainer Pot with water to the Suction Port. Replace the Lid ensuring that it
is sealed on the Gasket properly. Do not overtighten the Clamp Knobs.
2. Connect to power supply and switch ON.
3. Allow Pump to run discharging the water back to the pool.
4. If ow is not established within approximately 1 minute, switch off the Pump
and repeat procedure. Continued failure to prime may indicate an air leak in the
suction line which should be rectied.
ROUTINE MAINTENANCE
The Strainer Basket should be inspected frequently through the Clear Lid and emptied
as follows when a build-up of rubbish is evident.
1. Switch off Pump.
2. Remove Clear Lid.
3. Remove Strainer Basket.
4. Empty accumulated rubbish and hose Strainer Basket clean.
5. Replace Strainer Basket.
6. If Strainer Pot has emptied of water, repeat steps in “Starting the Pump”.
WATER LEAKS
7. Water leaking from under the Pump and Motor should be attended to immediately
as this would indicate a failure of the Pump Shaft Seal. If this seal is not
immediately replaced damage may occur.
8. Pool water leaking onto the pump motor from associated plumbing should be
attended to immediately before damage occurs.
MOTOR NOISE
9. If the Pump Motor starts to get “noisy” the Motor should be checked by a Pool
Technician to ascertain whether the Motor Bearings need replacement. This
should be attended to immediately as Bearing failure may cause Motor burn out.
LARGE AIR BUBBLES UNDER THE STRAINER POT LID
10. Check the Gasket under the Clear Lid and check the pipe connection to the
Suction Port at the front of the Pump to make sure it is tight - do not overtighten.
CHEMICAL BALANCE GUIDE
11. The unit is designed to be used for Spa or Swimming Pool water, balanced in
accordance with Langlier Saturation Index, with a pH level of 7.0 to 8.0 and is
regularly treated with a chlorine Sanitising agent, the level not exceeding 3 PPM.
TROUBLE SHOOTING GUIDE
If the Pump and Motor runs but there is little or no water ow, the following conditions
may apply:-
1. Check to see if the Filter needs cleaning or is blocked - refer to Filter Instruction
Manual.
2. Pump is not primed - re-prime as per instructions in “Starting Pump”.
3. Air leaks in suction lines - Check for air bubbles under Clear Lid and tighten.
Check all pipes and connections and repair if necessary.
4. Water on ground under the Pump and Motor usually indicates a damaged Pump
Shaft Seal - this should be repaired immediately or further damage may occur.
5. Pump unable to draw water from the pool - check that Valves to the Pump are
fully open and that the water level is correct in the pool.
6. Blockages - Check Strainer Basket and Pool Skimmer Basket are free of
obstruction. If a blockage is suspected inside the Pump or in the Pipework the
advice of your pool service technician should be sought.
If the motor does not run, the problem could be that:-
1. Power not connected - Check power point by plugging in a portable appliance to
ensure power is available. Also check Fuses and Main Power Supply Switch.
2. Overload tripped - Poolrite Motors incorporate an Internal Switch that will reset
automatically after the Motor has cooled.
3. Blockage preventing Pump from rotating.
4. Motor fused or “burnt out” - “burning” smell evident - replacement may be
required.
Warning
The Pump Motor is an electrical device and as such should not be disassembled or
serviced by anyone other than an authorised Poolrite Service Technician or qualied
Electricial Service Company.
If the supply cord is damaged it must be replaced by the manufacturer, its service
agent or similarly qualied persons in order to avoid a hazard.
This appliance is not intended for use by young children or inrm persons unless they
have been adequately supervised by a responsible person to ensure that they can use
the appliance safely.
Young children should be supervised to ensure that they do not play with the
appliance.
Also, any other problems that cannot be corrected by routine maintenance should be
attended to by an experienced Pool Service Technician.
QUIETLINE PUMP WARRANTY
In addition to the conditions of sale and warranties implied at law and which may not be
excluded, Evolve Group warrants the Quietline Pump to be free from defect for a period of:
(In-store sale & installed) 3 years for motor, 2 years for internals, 10 years on main
pump housing;
(In-store sale) 2 years for motor, 2 years for internals, 10 years on main pump housing;
(Online sale) 1 year for motor, 1 year for internals, 1 year on main pump housing;
from the date of purchase by the Owner from Evolve Group or an authorised supplier of
the Quietline Pump.*
Evolve Group will authorise a qualied technician to repair the Quietline Pump provided that:
• Evolve Group is notied within seven (7) days of the defect being detected;
• the Quietline Pump is not operated subsequent to detection of the defect;
• the Quietline Pump has not undergone any unauthorised modication or been tted with
other than genuine Poolrite approved parts; and
• the Quietline Pump has been installed and operated in accordance with the Installation
Instructions and Operating Instructions, respectively.
Evolve Group will not be liable to repair the Quietline Pump if the repair is neccessary
because of misuse, accidental damage, entry of foreign objects or materials into the
equipment, improper or inadequate maintenance or repair or incorrect operation of the
Quietline Pump.
This warranty does not extend to reasonable wear and tear of the Quietline Pump.
All repairs must be undertaken by a technician authorised by Evolve Group.
The Owner will be responsible for all freight and/or travelling charges. Evolve Group accepts
no responsibility for goods while in transit.
Evolve Group accepts no responsibility for representations other than as expressly
contained in literature published by Evolve Group. In particular Evolve Group has made no
representation as to the tness of the Quietline Pump for any particular purpose except as
contained in such literature.
Customer Record
Purchased From: _______________________________________________
_______________________________________________________
Purchase Date:_________________________________________________
Quietline
SQI Series
SWIMMING POOL PUMP
QUICK START GUIDE
The Evolve Group
PO Box 1491, Browns Plains QLD 4118
Phone: +61 7 3803 6222
Email: [email protected] | www.poolrite.com
Register your Warranty Registration Form
by scanning the QR code below
Complete, detach and return to Poolrite.
WARRANTY CARD
Name of Purchaser:
Address:
Purchased From:
Date:
Equipment and Model:
POOLRITE EQUIPMENT PTY LTD
A.B.N. 11 001 674 004
415 Creek Road, Mt. Gravatt. 4122
QLD. Australia
Telephone: (07) 3323 6555
Fax: (07) 3323 6500
pppppppppppppppppppppppp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pppppppppppppppppppppppp
QUIETLINE PUMP WARRANTY
In addition to the conditions of sale and warranties implied at law
and which may not be excluded, Poolrite warrants the Quietline
Pump to be free from defect for a period of three (3) years (one (1)
year on Mechanical Seal) from the date of purchase by the Owner
from Poolrite or an authorised supplier of the Quietline Pump.
Poolrite will repair, or authorise a qualified technician to repair, the
Quietline Pump provided that:
●Poolrite is notified within seven (7) days of the defect being
detected;
●the Quietline Pump is not operated subsequent to detection
of the defect;
●the Quietline Pump has not undergone any unauthorised
modification or been fitted with other than genuine Poolrite
approved parts; and
●the Quietline Pump has been installed and operated in
accordance with the Installation Instructions and Operating
Instructions, respectively.
Poolrite will not be liable to repair the Quietline Pump if the
repair is neccessary because of misuse, accidental damage,
entry of foreign objects or materials into the equipment,
improper or inadequate maintenance or repair or incorrect
operation of the Quietline Pump.
This warranty does not extend to reasonable wear and tear of
the Quietline Pump.
All repairs must be undertaken by Poolrite or a technician
authorised by Poolrite.
The Owner will be responsible for all freight and/or travelling
charges. Poolrite accepts no responsibility for goods while in
transit.
Poolrite accepts no responsibility for representations other than
as expressly contained in literature published by Poolrite. In
particular Poolrite has made no representation as to the fitness
of the Quietline Pump for any particular purpose except as
contained in such literature.
CUSTOMER RECORD
Purchased From:
Purchase Date:
Item No. 22520
Stella Print
(8/06) Rev. 2
150mm
(min.)
UNION ADAPTOR
DISCHARGE PORT
CLEAR LID CLAMP KNOB
(GASKET)
UNION
ADAPTOR
SUCTION
PORT
(STRAINER BASKET)
STRAINER POT
✄ ✄✄
Quietline
SQ I Ser i es
swimming pool & spa pool pump
IN STA LLATIO N
I N STRU CTI O N S
PO O LRITE EQ U I PM EN T PTY LTD
A.B.N. 11 001 674 004
415 Creek Road, Mt. Gravatt. 4122 QLD. Australia
Telephone: (07) 3323 6555 Fax: (07) 3323 6500
Complete, detach and return to Poolrite.
WARRANTY CARD
Name of Purchaser:
Address:
Purchased From:
Date:
Equipment and Model:
POOLRITE EQUIPMENT PTY LTD
A.B.N. 11 001 674 004
415 Creek Road, Mt. Gravatt. 4122
QLD. Australia
Telephone: (07) 3323 6555
Fax: (07) 3323 6500
pppppppppppppppppppppppp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pp
pppppppppppppppppppppppp
QUIETLINE PUMP WARRANTY
In addition to the conditions of sale and warranties implied at law
and which may not be excluded, Poolrite warrants the Quietline
Pump to be free from defect for a period of three (3) years (one (1)
year on Mechanical Seal) from the date of purchase by the Owner
from Poolrite or an authorised supplier of the Quietline Pump.
Poolrite will repair, or authorise a qualified technician to repair, the
Quietline Pump provided that:
●Poolrite is notified within seven (7) days of the defect being
detected;
●the Quietline Pump is not operated subsequent to detection
of the defect;
●the Quietline Pump has not undergone any unauthorised
modification or been fitted with other than genuine Poolrite
approved parts; and
●the Quietline Pump has been installed and operated in
accordance with the Installation Instructions and Operating
Instructions, respectively.
Poolrite will not be liable to repair the Quietline Pump if the
repair is neccessary because of misuse, accidental damage,
entry of foreign objects or materials into the equipment,
improper or inadequate maintenance or repair or incorrect
operation of the Quietline Pump.
This warranty does not extend to reasonable wear and tear of
the Quietline Pump.
All repairs must be undertaken by Poolrite or a technician
authorised by Poolrite.
The Owner will be responsible for all freight and/or travelling
charges. Poolrite accepts no responsibility for goods while in
transit.
Poolrite accepts no responsibility for representations other than
as expressly contained in literature published by Poolrite. In
particular Poolrite has made no representation as to the fitness
of the Quietline Pump for any particular purpose except as
contained in such literature.
CUSTOMER RECORD
Purchased From:
Purchase Date:
Item No. 22520
Stella Print
(8/06) Rev. 2
150mm
(min.)
UNION ADAPTOR
DISCHARGE PORT
CLEAR LID CLAMP KNOB
(GASKET)
UNION
ADAPTOR
SUCTION
PORT
(STRAINER BASKET)
STRAINER POT
✄ ✄✄
Quietline
SQ I Ser i es
swimming pool & spa pool pump
IN STA LLATIO N
I N STRU CTI O N S
PO O LRITE EQ U IPM EN T PTY LTD
A.B.N. 11 001 674 004
415 Creek Road, Mt. Gravatt. 4122 QLD. Australia
Telephone: (07) 3323 6555 Fax: (07) 3323 6500

Other PoolRite Swimming Pool Pump manuals

PoolRite QuietlineSQI Series User manual

PoolRite

PoolRite QuietlineSQI Series User manual

PoolRite Enduro EP 750 User manual

PoolRite

PoolRite Enduro EP 750 User manual

PoolRite SQI 400 User manual

PoolRite

PoolRite SQI 400 User manual

PoolRite Enduro EP 750 User manual

PoolRite

PoolRite Enduro EP 750 User manual

PoolRite Enduro EP 750 User manual

PoolRite

PoolRite Enduro EP 750 User manual

Popular Swimming Pool Pump manuals by other brands

Pentair Pool Products SuperFlo Installation and user guide

Pentair Pool Products

Pentair Pool Products SuperFlo Installation and user guide

KWAD Green Energy ECO 3 User and service manual

KWAD

KWAD Green Energy ECO 3 User and service manual

Intex Krystal Clear 638G owner's manual

Intex

Intex Krystal Clear 638G owner's manual

OBlue SUPER CLEAN AC-90573A owner's manual

OBlue

OBlue SUPER CLEAN AC-90573A owner's manual

Pentair STA-RITE SILENTFLO SF550100 owner's manual

Pentair

Pentair STA-RITE SILENTFLO SF550100 owner's manual

Pontec PondoMax Eco 1500 operating instructions

Pontec

Pontec PondoMax Eco 1500 operating instructions

Intex CS15220 owner's manual

Intex

Intex CS15220 owner's manual

Xtreme Power 75131 Owner's manual and safety instructions

Xtreme Power

Xtreme Power 75131 Owner's manual and safety instructions

Astral Pool Viron P320 eVo Original instructions

Astral Pool

Astral Pool Viron P320 eVo Original instructions

Astral Pool VICTORIA PLUS SILENT manual

Astral Pool

Astral Pool VICTORIA PLUS SILENT manual

Hybrid+ 55 Installation and operation manual

Hybrid+

Hybrid+ 55 Installation and operation manual

POLYGROUP LIMITED RX600-NF owner's manual

POLYGROUP LIMITED

POLYGROUP LIMITED RX600-NF owner's manual

Aquagem IP20 Installation and operation manual

Aquagem

Aquagem IP20 Installation and operation manual

Calpeda NMP operating instructions

Calpeda

Calpeda NMP operating instructions

Space Bad Boy Charlie quick start guide

Space

Space Bad Boy Charlie quick start guide

Harmopool Harmo Kubi ZVWX4015 instruction manual

Harmopool

Harmopool Harmo Kubi ZVWX4015 instruction manual

T.I.P. CoverOne 1500 AUT Translation of original operating instructions

T.I.P.

T.I.P. CoverOne 1500 AUT Translation of original operating instructions

AES EFI Series Installation and operation manual

AES

AES EFI Series Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.