Applications
These microscopes are suitable for student use in primary and middle
schools for observing various biological specimens, such as spores,
insects and stem sections. Model MS-01L is equipped with three
objectives and the standard disc diaphragm. Model MS-03L has the
additional 100X oil immersion objective, a spiral mounted substage
condenser with iris diaphragm and the mechanical stage slide holder
(optional for MS-01). Both MS-01L and MS-03L are equipped with
a built in rechargeable battery and a detachable AC power cord for
cordless operation.
Specifications
1. Objectives
Magnifying Power Numerical Aperture
4X 0.10
10X 0.25
40X 0.65
100X (MS-03 only) 1.25
2. Eyepiece
Type Magnification Diameter of Field(mm)
Widefield 10X 15
3. Range offocus control: Coarse and Fine--- 8 mm
4. MS-01L: 6 aperture disc diaphragm
MS-03L: Spiral mount condenser with iris diaphragm
5. Illumination: 4.5V LED CoolIllumination System
Optional Upgrade for MS-01L
Mechanical Stage: movable spring clip installed on the stage platform
which holds the microscope slide in place and allows slide to be
moved left/right or forward/backward during observation. Two knobs
controlthe X &Y movement.
Operation
1. Put slide on the observation stage platformand fix with clips.
2. Turn the coarse adjustment (large) knob, observing the image of
the specimen through the eyepiece. Use the fine adjustment
(small) knob for more clarity.
3. MS-01L: The disc diaphragm, located directly below the stage,
has six different size apertures (openings) which allow light to
pass through to shine on the specimen. By rotating this disc, you
can alter the amount of light that is aimed at the specimen.
MS-03L: The spiral mount condenser assembly can be shifted
up or down by means of the control knob (left hand side under
the stage) to effectively move the light beam closer to (up) or
away from (down) the specimen under observation. The iris
diaphragm on the bottom of the condenser can be opened
(slide lever forward) or closed (slide lever back to left) to
control the amount of light directed through the condenser.
Try experimenting with various settings to get the most
effective view of your specimen.
4. Rotate nosepiece as needed for desired magnifications and adjust
fine focus slightly for clearest view.
5. It is important to remember when adjusting the focus that the
objective should never touch the specimen. When increasing
to 100X objective (1000X magnification-Model MS-03L
only), the objective will appear to be very close to the slide.
Because the 100X is an oil immersion objective, a drop of
cedar-wood oil or other immersion oil should be applied in the
gap between the objective and the specimen. (Note: All slides
should be prepared with cover slips over the specimen for
observation under the 100X objective.) The 100X oil
immersion objective should be wiped off with a piece of soft
clean cloth or lens tissue to remove the
immersion oil immediately after using.
STUDENT MICROSCOPES
Maintenance
1. Keep the instrument in dryand coolplace.
2. Keep the objectives and eyepiece clean. Clean the opticalglasses
when needed with lens paper. If necessary, apply a small amount
of optical glass cleaner (commercially available—the type used on
cameras and other optical lens).
Recharging
Insert the cord into the AC adaptor, found at the base of the
microscope, and then plug into the wall. Charging only takes place
when the microscope is “OFF.” We recommend that the
microscope be recharged only when the battery is fully drained, so
as to prolong the battery’s lifespan.
MS-01L MS-03L
USER’S MANUAL
Models MS-01L & MS-03L
Thank you for purchasing this Microscope.
Before use, please read this manual to learn about all the available
features to obtain the best results from your microscope.
Warning:
To prevent fire or shock hazard, do not expose this unit to rain or moisture.
This equipment should be used with AC 110V, 60Hz in the USA or Canada.
No user-serviceable parts inside. Refer servicing to qualified service personnel.
Premiere®trademark reg. No. 1713212 USA
The manufacturer warrants this instrument to be free from defects in
material and workmanship under normal use for five years from the date
of purchase (one year for electrical components). It does not cover
damage resulting from abuse or misuse, repairs or alterations performed
by other than authorized repair technicians, or damage occurring in
transit. If you have questions concerning this product or warranty, contact
the dealer from whom it was purchased. For warranty service,
microscope should be well packed to avoid damage in transit, preferably
in original box and packing. Include your complete return address and
telephone number as well as a description of the difficulty, date and
place of purchase, and ship to the address below. It will be repaired or
replaced at no charge and returned. If misuse, alterations, accident or
abnormal conditions of operation caused failure, an estimate for repairs
will be provided for your approval prior to work being performed.
Premiere Microscope Service Department
7241 Gabe Court
Manassas, VA 20109
(703) 330-1413
(7/1)

Other manuals for MS-01L

1

This manual suits for next models

1

Other premiere Microscope manuals

premiere MRJ-01 User manual

premiere

premiere MRJ-01 User manual

premiere Vetlab 125 User manual

premiere

premiere Vetlab 125 User manual

premiere SMZ-05 User manual

premiere

premiere SMZ-05 User manual

premiere Vetlab Premiere 500 User manual

premiere

premiere Vetlab Premiere 500 User manual

premiere MRP-3000 User manual

premiere

premiere MRP-3000 User manual

premiere MS-01L User manual

premiere

premiere MS-01L User manual

Popular Microscope manuals by other brands

AmScope ZM-1 Series user manual

AmScope

AmScope ZM-1 Series user manual

Optika Italy 4083.2 instruction manual

Optika Italy

Optika Italy 4083.2 instruction manual

Olympus FHT-521 instruction manual

Olympus

Olympus FHT-521 instruction manual

Bresser Biorit ICD-CS instruction manual

Bresser

Bresser Biorit ICD-CS instruction manual

Olympus BX53M instructions

Olympus

Olympus BX53M instructions

KERN Optics OBE 121 User instructions

KERN Optics

KERN Optics OBE 121 User instructions

Eurotops 49929 manual

Eurotops

Eurotops 49929 manual

Motic PA53MET user manual

Motic

Motic PA53MET user manual

Viavi FiberChek quick start guide

Viavi

Viavi FiberChek quick start guide

Labomed Magna user manual

Labomed

Labomed Magna user manual

Optika B-500TiFL Operation manual

Optika

Optika B-500TiFL Operation manual

Meiji Techno MT7500 series instruction manual

Meiji Techno

Meiji Techno MT7500 series instruction manual

Zeiss Axiocam MR Installation and reference guide

Zeiss

Zeiss Axiocam MR Installation and reference guide

Caltex LX-100 user guide

Caltex

Caltex LX-100 user guide

Zeiss opmi lumera 700 Basic instructions

Zeiss

Zeiss opmi lumera 700 Basic instructions

SMART Solutions SM-1080BL3DHD1 user manual

SMART Solutions

SMART Solutions SM-1080BL3DHD1 user manual

Unitron LX Microscopes MIDAS user manual

Unitron

Unitron LX Microscopes MIDAS user manual

STEINDORFF NYMCS-1701 user manual

STEINDORFF

STEINDORFF NYMCS-1701 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.