Prime Wire & Cable TNOLED02 User manual

1. INSTALL TIMER to a vertical
flat surface close to a
properly installed outdoor-
rated grounded receptacle
a. Using a screw or hook (not
included), secure the
MOUNTING TAB at the top
of the timer to a wall or post.
b. For a more secure mounting,
use the two MOUNTING
HOLES on the back of the
timer.
• Create a mounting
template by placing a
sheet of paper over the
back of the timer and
punching holes through the
paper where the mounting
holes are located on the timer.
• Temporarily secure the mounting template to
the flat surface where the timer is to be mounted.
• Drill two 3/32 inch pilot holes where indicated
on the mounting template.
• Insert two #6 sheet metal screws (not included),
leaving screw heads protruding 1/8 inch from the
surface.
• Place the timer over the screw heads and push
down to lock into place.
2. Plug timer into an
ELECTRICAL OUTLET
Use an outdoor-rated three-
pronged grounded electrical
outlet. Do not use extension
cords to connect the timer to
the power source.
Light Sensing
Digital
Countdown Timer
Model: TNOLED02
STEP-BY-STEP
INSTRUCTIONS
3. Set the desired “OPERATING
MODE”
Press the “SET” button to cycle
the LED’s to the desired mode.
After 5 seconds, LED will flash
rapidly to confirm selection.
4. Attach up to TWO DEVICES
to the timer
Plug the devices into the outlets
on the bottom of the timer.
HELPFUL TIPS
• This timer is weather-resistant and rated for Outdoor
Use. The timer will function outdoors when installed
and operated as outlined in this manual.
• This timer operates using a light-sensitive photocell
that senses when the environment is getting dark
(dusk) or light (dawn). The photocell is located above
the “SET” button on the face of the timer.
• Once programming activates at dusk in the 2hr, 4hr,
6hr, 8hr, 12hr or dusk-to-dawn mode, the program
cycle will complete before the timer resets.
Headlights, porch lights, street lamps and other
external lighting sources will not interfere with the
active timer program.
• When set to “ON”, the timer will provide continual
power to attached devices until the timer is switched
to “OFF”, or to any of the other Operating Modes.
• The LED next to the programmed mode will glow red
when the timer programming is activated and power
is being provided to attached devices.
• To view the program that is currently set when the
timer is not providing power to the attached devices,
press the “SET” button. The LED next to the
programmed mode will illuminate.
WARNING
Risk of Electric Shock
Keep children away. Unplug timer before cleaning. Fully
insert plug. Do not use near standing water.
Risk of Fire
Do not use to control appliances that contain heating
elements (cooking appliances, heaters, irons, etc.). Do not
exceed electrical ratings.
IN CASE OF POWER FAILURE
Timer will stop operating if the power goes out. Once
power is restored, reset the desired operating mode as
explained in step 3 of the instructions.
ON - Power is on to attached devices
2 Hrs - Power will turn on at dusk and
remain on for 2 hours
4 Hrs - Power will turn on at dusk and
remain on for 4 hours
6 Hrs - Power will turn on at dusk and
remain on for 6 hours
8 Hrs - Power will turn on at dusk and
remain on for 8 hours
12 Hrs
- Power will turn on at dusk and
remain on for 12 hours
Dusk-Dawn - Power will turn on at
dusk and remain on until dawn
OFF - Power is off to attached devices
b
aAVERTISSEMENT
Risque de choc électrique
Garder hors de portée des enfants. Débrancher la
minuterie avant de nettoyer. Insérer complètement la fiche.
Ne pas utiliser près de l’eau stagnante.
Risque d’incendie
Ne pas utiliser pour contrôler les appareils contenant des
éléments chauffants (équipements de cuisine, radiateurs,
fers à repasser, etc.). Ne pas excéder la capacité électrique.
FCC REGULATORY STATEMENT
WARNING: Changes or modifications to this unit not expressly
approved by the party responsible for compliance could void the
user authority to operate the equipment.
This device complies with part 15 of the FCC rules. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including
interference that may cause undesired operation.
Notes: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
4. Consult the dealer or an experienced radio/TV technician for
help.
IC REGULATORY STATEMENT
Under Industry Canada regulations, this radio transmitter may only
operate using an antenna of a type and maximum (or lesser) gain
approved for the transmitter by Industry Canada. To reduce potential
radio interference to other users, the antenna type and its gain
should be so chosen that the equivalent isotropically radiated power
(e.i.r.p.) is not more than that necessary for successful
communication.
This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions: (1)
this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause
undesired operation of the device.
LIMITED 1 YEAR WARRANTY
Prime warrants this product to be free from manufacturing defects for
a period of one year from the original date of purchase (“warranty
period”). This warranty is limited to the repair or replacement of this
product only and Prime is not liable for any consequential or incidental
damage to other products that may be used with this unit. This
warranty is effective only if such unit is returned to Prime not later than
thirty (30) days after the expiration of the warranty period. Warranty is
void if damage is due to neglect, misuse, alteration, modification,
improper installation, or repair by other than Prime. This warranty is in
lieu of all other warranties express or implied. Some states do not
allow limitations on how long an implied warranty lasts or permit the
exclusion or limitation of incidental or consequential damages, so the
above limitations may not apply to you.
It is our experience that a product that fails prematurely due to a
manufacturing defect in materials or workmanship, will generally do
so very early in the product’s life cycle, often the first or second time
the product is used. Products that are returned for warranty inspection
after months or years of continuous reliable service are usually the
result of normal wear and tear, which is not considered a defect in
materials or workmanship and therefore is not covered by the
warranty.
This warranty gives you specific rights, and you may also have other
rights which vary from state to state. If unit should prove defective
within the warranty period, return within the time period set forth
above prepaid with the original purchase receipt to:
Prime Wire & Cable, Inc.
ATTN: Timer Warranty
280 Machlin Court
City of Industry, CA 91789
Service - (888) 445-9955 • www.primewirecable.com
SAFETY INFORMATION & SPECIFICATIONS
THIS TIMER IS A “GROUNDED” DEVICE. The male
plug contains a ground pin and is only intended for
use with a three-pronged grounded outlet.
THIS TIMER IS FOR USE WITH A 125VAC POWER SOURCE.
125VAC / 60Hz
DO NOT ATTACH A DEVICE THAT EXCEEDS THE UNIT
RATINGS:
15A / 1875W Resistive (General Purpose)
8A / 1000W Tungsten (Incandescent)
1/3 HP (Horsepower Motor)

1. INSTALL TIMER to a vertical
flat surface close to a
properly installed outdoor-
rated grounded receptacle
a. Using a screw or hook (not
included), secure the
MOUNTING TAB at the top
of the timer to a wall or post.
b. For a more secure mounting,
use the two MOUNTING
HOLES on the back of the
timer.
• Create a mounting
template by placing a
sheet of paper over the
back of the timer and
punching holes through the
paper where the mounting
holes are located on the timer.
• Temporarily secure the mounting template to
the flat surface where the timer is to be mounted.
• Drill two 3/32 inch pilot holes where indicated
on the mounting template.
• Insert two #6 sheet metal screws (not included),
leaving screw heads protruding 1/8 inch from the
surface.
• Place the timer over the screw heads and push
down to lock into place.
2. Plug timer into an
ELECTRICAL OUTLET
Use an outdoor-rated three-
pronged grounded electrical
outlet. Do not use extension
cords to connect the timer to
the power source.
Light Sensing
Digital
Countdown Timer
Model: TNOLED02
STEP-BY-STEP
INSTRUCTIONS
3. Set the desired “OPERATING
MODE”
Press the “SET” button to cycle
the LED’s to the desired mode.
After 5 seconds, LED will flash
rapidly to confirm selection.
4. Attach up to TWO DEVICES
to the timer
Plug the devices into the outlets
on the bottom of the timer.
HELPFUL TIPS
• This timer is weather-resistant and rated for Outdoor
Use. The timer will function outdoors when installed
and operated as outlined in this manual.
• This timer operates using a light-sensitive photocell
that senses when the environment is getting dark
(dusk) or light (dawn). The photocell is located above
the “SET” button on the face of the timer.
• Once programming activates at dusk in the 2hr, 4hr,
6hr, 8hr, 12hr or dusk-to-dawn mode, the program
cycle will complete before the timer resets.
Headlights, porch lights, street lamps and other
external lighting sources will not interfere with the
active timer program.
• When set to “ON”, the timer will provide continual
power to attached devices until the timer is switched
to “OFF”, or to any of the other Operating Modes.
• The LED next to the programmed mode will glow red
when the timer programming is activated and power
is being provided to attached devices.
• To view the program that is currently set when the
timer is not providing power to the attached devices,
press the “SET” button. The LED next to the
programmed mode will illuminate.
WARNING
Risk of Electric Shock
Keep children away. Unplug timer before cleaning. Fully
insert plug. Do not use near standing water.
Risk of Fire
Do not use to control appliances that contain heating
elements (cooking appliances, heaters, irons, etc.). Do not
exceed electrical ratings.
IN CASE OF POWER FAILURE
Timer will stop operating if the power goes out. Once
power is restored, reset the desired operating mode as
explained in step 3 of the instructions.
ON - Power is on to attached devices
2 Hrs - Power will turn on at dusk and
remain on for 2 hours
4 Hrs - Power will turn on at dusk and
remain on for 4 hours
6 Hrs - Power will turn on at dusk and
remain on for 6 hours
8 Hrs - Power will turn on at dusk and
remain on for 8 hours
12 Hrs
- Power will turn on at dusk and
remain on for 12 hours
Dusk-Dawn - Power will turn on at
dusk and remain on until dawn
OFF - Power is off to attached devices
b
aAVERTISSEMENT
Risque de choc électrique
Garder hors de portée des enfants. Débrancher la
minuterie avant de nettoyer. Insérer complètement la fiche.
Ne pas utiliser près de l’eau stagnante.
Risque d’incendie
Ne pas utiliser pour contrôler les appareils contenant des
éléments chauffants (équipements de cuisine, radiateurs,
fers à repasser, etc.). Ne pas excéder la capacité électrique.
FCC REGULATORY STATEMENT
WARNING: Changes or modifications to this unit not expressly
approved by the party responsible for compliance could void the
user authority to operate the equipment.
This device complies with part 15 of the FCC rules. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including
interference that may cause undesired operation.
Notes: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
4. Consult the dealer or an experienced radio/TV technician for
help.
IC REGULATORY STATEMENT
Under Industry Canada regulations, this radio transmitter may only
operate using an antenna of a type and maximum (or lesser) gain
approved for the transmitter by Industry Canada. To reduce potential
radio interference to other users, the antenna type and its gain
should be so chosen that the equivalent isotropically radiated power
(e.i.r.p.) is not more than that necessary for successful
communication.
This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions: (1)
this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause
undesired operation of the device.
LIMITED 1 YEAR WARRANTY
Prime warrants this product to be free from manufacturing defects for
a period of one year from the original date of purchase (“warranty
period”). This warranty is limited to the repair or replacement of this
product only and Prime is not liable for any consequential or incidental
damage to other products that may be used with this unit. This
warranty is effective only if such unit is returned to Prime not later than
thirty (30) days after the expiration of the warranty period. Warranty is
void if damage is due to neglect, misuse, alteration, modification,
improper installation, or repair by other than Prime. This warranty is in
lieu of all other warranties express or implied. Some states do not
allow limitations on how long an implied warranty lasts or permit the
exclusion or limitation of incidental or consequential damages, so the
above limitations may not apply to you.
It is our experience that a product that fails prematurely due to a
manufacturing defect in materials or workmanship, will generally do
so very early in the product’s life cycle, often the first or second time
the product is used. Products that are returned for warranty inspection
after months or years of continuous reliable service are usually the
result of normal wear and tear, which is not considered a defect in
materials or workmanship and therefore is not covered by the
warranty.
This warranty gives you specific rights, and you may also have other
rights which vary from state to state. If unit should prove defective
within the warranty period, return within the time period set forth
above prepaid with the original purchase receipt to:
Prime Wire & Cable, Inc.
ATTN: Timer Warranty
280 Machlin Court
City of Industry, CA 91789
Service - (888) 445-9955 • www.primewirecable.com
SAFETY INFORMATION & SPECIFICATIONS
THIS TIMER IS A “GROUNDED” DEVICE. The male
plug contains a ground pin and is only intended for
use with a three-pronged grounded outlet.
THIS TIMER IS FOR USE WITH A 125VAC POWER SOURCE.
125VAC / 60Hz
DO NOT ATTACH A DEVICE THAT EXCEEDS THE UNIT
RATINGS:
15A / 1875W Resistive (General Purpose)
8A / 1000W Tungsten (Incandescent)
1/3 HP (Horsepower Motor)

1. INSTALL TIMER to a vertical
flat surface close to a
properly installed outdoor-
rated grounded receptacle
a. Using a screw or hook (not
included), secure the
MOUNTING TAB at the top
of the timer to a wall or post.
b. For a more secure mounting,
use the two MOUNTING
HOLES on the back of the
timer.
• Create a mounting
template by placing a
sheet of paper over the
back of the timer and
punching holes through the
paper where the mounting
holes are located on the timer.
• Temporarily secure the mounting template to
the flat surface where the timer is to be mounted.
• Drill two 3/32 inch pilot holes where indicated
on the mounting template.
• Insert two #6 sheet metal screws (not included),
leaving screw heads protruding 1/8 inch from the
surface.
• Place the timer over the screw heads and push
down to lock into place.
2. Plug timer into an
ELECTRICAL OUTLET
Use an outdoor-rated three-
pronged grounded electrical
outlet. Do not use extension
cords to connect the timer to
the power source.
Light Sensing
Digital
Countdown Timer
Model: TNOLED02
STEP-BY-STEP
INSTRUCTIONS
3. Set the desired “OPERATING
MODE”
Press the “SET” button to cycle
the LED’s to the desired mode.
After 5 seconds, LED will flash
rapidly to confirm selection.
4. Attach up to TWO DEVICES
to the timer
Plug the devices into the outlets
on the bottom of the timer.
HELPFUL TIPS
• This timer is weather-resistant and rated for Outdoor
Use. The timer will function outdoors when installed
and operated as outlined in this manual.
• This timer operates using a light-sensitive photocell
that senses when the environment is getting dark
(dusk) or light (dawn). The photocell is located above
the “SET” button on the face of the timer.
• Once programming activates at dusk in the 2hr, 4hr,
6hr, 8hr, 12hr or dusk-to-dawn mode, the program
cycle will complete before the timer resets.
Headlights, porch lights, street lamps and other
external lighting sources will not interfere with the
active timer program.
• When set to “ON”, the timer will provide continual
power to attached devices until the timer is switched
to “OFF”, or to any of the other Operating Modes.
• The LED next to the programmed mode will glow red
when the timer programming is activated and power
is being provided to attached devices.
• To view the program that is currently set when the
timer is not providing power to the attached devices,
press the “SET” button. The LED next to the
programmed mode will illuminate.
WARNING
Risk of Electric Shock
Keep children away. Unplug timer before cleaning. Fully
insert plug. Do not use near standing water.
Risk of Fire
Do not use to control appliances that contain heating
elements (cooking appliances, heaters, irons, etc.). Do not
exceed electrical ratings.
IN CASE OF POWER FAILURE
Timer will stop operating if the power goes out. Once
power is restored, reset the desired operating mode as
explained in step 3 of the instructions.
ON - Power is on to attached devices
2 Hrs - Power will turn on at dusk and
remain on for 2 hours
4 Hrs - Power will turn on at dusk and
remain on for 4 hours
6 Hrs - Power will turn on at dusk and
remain on for 6 hours
8 Hrs - Power will turn on at dusk and
remain on for 8 hours
12 Hrs
- Power will turn on at dusk and
remain on for 12 hours
Dusk-Dawn - Power will turn on at
dusk and remain on until dawn
OFF - Power is off to attached devices
b
aAVERTISSEMENT
Risque de choc électrique
Garder hors de portée des enfants. Débrancher la
minuterie avant de nettoyer. Insérer complètement la fiche.
Ne pas utiliser près de l’eau stagnante.
Risque d’incendie
Ne pas utiliser pour contrôler les appareils contenant des
éléments chauffants (équipements de cuisine, radiateurs,
fers à repasser, etc.). Ne pas excéder la capacité électrique.
FCC REGULATORY STATEMENT
WARNING: Changes or modifications to this unit not expressly
approved by the party responsible for compliance could void the
user authority to operate the equipment.
This device complies with part 15 of the FCC rules. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including
interference that may cause undesired operation.
Notes: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
4. Consult the dealer or an experienced radio/TV technician for
help.
IC REGULATORY STATEMENT
Under Industry Canada regulations, this radio transmitter may only
operate using an antenna of a type and maximum (or lesser) gain
approved for the transmitter by Industry Canada. To reduce potential
radio interference to other users, the antenna type and its gain
should be so chosen that the equivalent isotropically radiated power
(e.i.r.p.) is not more than that necessary for successful
communication.
This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions: (1)
this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause
undesired operation of the device.
LIMITED 1 YEAR WARRANTY
Prime warrants this product to be free from manufacturing defects for
a period of one year from the original date of purchase (“warranty
period”). This warranty is limited to the repair or replacement of this
product only and Prime is not liable for any consequential or incidental
damage to other products that may be used with this unit. This
warranty is effective only if such unit is returned to Prime not later than
thirty (30) days after the expiration of the warranty period. Warranty is
void if damage is due to neglect, misuse, alteration, modification,
improper installation, or repair by other than Prime. This warranty is in
lieu of all other warranties express or implied. Some states do not
allow limitations on how long an implied warranty lasts or permit the
exclusion or limitation of incidental or consequential damages, so the
above limitations may not apply to you.
It is our experience that a product that fails prematurely due to a
manufacturing defect in materials or workmanship, will generally do
so very early in the product’s life cycle, often the first or second time
the product is used. Products that are returned for warranty inspection
after months or years of continuous reliable service are usually the
result of normal wear and tear, which is not considered a defect in
materials or workmanship and therefore is not covered by the
warranty.
This warranty gives you specific rights, and you may also have other
rights which vary from state to state. If unit should prove defective
within the warranty period, return within the time period set forth
above prepaid with the original purchase receipt to:
Prime Wire & Cable, Inc.
ATTN: Timer Warranty
280 Machlin Court
City of Industry, CA 91789
Service - (888) 445-9955 • www.primewirecable.com
SAFETY INFORMATION & SPECIFICATIONS
THIS TIMER IS A “GROUNDED” DEVICE. The male
plug contains a ground pin and is only intended for
use with a three-pronged grounded outlet.
THIS TIMER IS FOR USE WITH A 125VAC POWER SOURCE.
125VAC / 60Hz
DO NOT ATTACH A DEVICE THAT EXCEEDS THE UNIT
RATINGS:
15A / 1875W Resistive (General Purpose)
8A / 1000W Tungsten (Incandescent)
1/3 HP (Horsepower Motor)

1. INSTALL TIMER to a vertical
flat surface close to a
properly installed outdoor-
rated grounded receptacle
a. Using a screw or hook (not
included), secure the
MOUNTING TAB at the top
of the timer to a wall or post.
b. For a more secure mounting,
use the two MOUNTING
HOLES on the back of the
timer.
• Create a mounting
template by placing a
sheet of paper over the
back of the timer and
punching holes through the
paper where the mounting
holes are located on the timer.
• Temporarily secure the mounting template to
the flat surface where the timer is to be mounted.
• Drill two 3/32 inch pilot holes where indicated
on the mounting template.
• Insert two #6 sheet metal screws (not included),
leaving screw heads protruding 1/8 inch from the
surface.
• Place the timer over the screw heads and push
down to lock into place.
2. Plug timer into an
ELECTRICAL OUTLET
Use an outdoor-rated three-
pronged grounded electrical
outlet. Do not use extension
cords to connect the timer to
the power source.
Light Sensing
Digital
Countdown Timer
Model: TNOLED02
STEP-BY-STEP
INSTRUCTIONS
3. Set the desired “OPERATING
MODE”
Press the “SET” button to cycle
the LED’s to the desired mode.
After 5 seconds, LED will flash
rapidly to confirm selection.
4. Attach up to TWO DEVICES
to the timer
Plug the devices into the outlets
on the bottom of the timer.
HELPFUL TIPS
• This timer is weather-resistant and rated for Outdoor
Use. The timer will function outdoors when installed
and operated as outlined in this manual.
• This timer operates using a light-sensitive photocell
that senses when the environment is getting dark
(dusk) or light (dawn). The photocell is located above
the “SET” button on the face of the timer.
• Once programming activates at dusk in the 2hr, 4hr,
6hr, 8hr, 12hr or dusk-to-dawn mode, the program
cycle will complete before the timer resets.
Headlights, porch lights, street lamps and other
external lighting sources will not interfere with the
active timer program.
• When set to “ON”, the timer will provide continual
power to attached devices until the timer is switched
to “OFF”, or to any of the other Operating Modes.
• The LED next to the programmed mode will glow red
when the timer programming is activated and power
is being provided to attached devices.
• To view the program that is currently set when the
timer is not providing power to the attached devices,
press the “SET” button. The LED next to the
programmed mode will illuminate.
WARNING
Risk of Electric Shock
Keep children away. Unplug timer before cleaning. Fully
insert plug. Do not use near standing water.
Risk of Fire
Do not use to control appliances that contain heating
elements (cooking appliances, heaters, irons, etc.). Do not
exceed electrical ratings.
IN CASE OF POWER FAILURE
Timer will stop operating if the power goes out. Once
power is restored, reset the desired operating mode as
explained in step 3 of the instructions.
ON - Power is on to attached devices
2 Hrs - Power will turn on at dusk and
remain on for 2 hours
4 Hrs - Power will turn on at dusk and
remain on for 4 hours
6 Hrs - Power will turn on at dusk and
remain on for 6 hours
8 Hrs - Power will turn on at dusk and
remain on for 8 hours
12 Hrs
- Power will turn on at dusk and
remain on for 12 hours
Dusk-Dawn - Power will turn on at
dusk and remain on until dawn
OFF - Power is off to attached devices
b
aAVERTISSEMENT
Risque de choc électrique
Garder hors de portée des enfants. Débrancher la
minuterie avant de nettoyer. Insérer complètement la fiche.
Ne pas utiliser près de l’eau stagnante.
Risque d’incendie
Ne pas utiliser pour contrôler les appareils contenant des
éléments chauffants (équipements de cuisine, radiateurs,
fers à repasser, etc.). Ne pas excéder la capacité électrique.
FCC REGULATORY STATEMENT
WARNING: Changes or modifications to this unit not expressly
approved by the party responsible for compliance could void the
user authority to operate the equipment.
This device complies with part 15 of the FCC rules. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including
interference that may cause undesired operation.
Notes: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
4. Consult the dealer or an experienced radio/TV technician for
help.
IC REGULATORY STATEMENT
Under Industry Canada regulations, this radio transmitter may only
operate using an antenna of a type and maximum (or lesser) gain
approved for the transmitter by Industry Canada. To reduce potential
radio interference to other users, the antenna type and its gain
should be so chosen that the equivalent isotropically radiated power
(e.i.r.p.) is not more than that necessary for successful
communication.
This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions: (1)
this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause
undesired operation of the device.
LIMITED 1 YEAR WARRANTY
Prime warrants this product to be free from manufacturing defects for
a period of one year from the original date of purchase (“warranty
period”). This warranty is limited to the repair or replacement of this
product only and Prime is not liable for any consequential or incidental
damage to other products that may be used with this unit. This
warranty is effective only if such unit is returned to Prime not later than
thirty (30) days after the expiration of the warranty period. Warranty is
void if damage is due to neglect, misuse, alteration, modification,
improper installation, or repair by other than Prime. This warranty is in
lieu of all other warranties express or implied. Some states do not
allow limitations on how long an implied warranty lasts or permit the
exclusion or limitation of incidental or consequential damages, so the
above limitations may not apply to you.
It is our experience that a product that fails prematurely due to a
manufacturing defect in materials or workmanship, will generally do
so very early in the product’s life cycle, often the first or second time
the product is used. Products that are returned for warranty inspection
after months or years of continuous reliable service are usually the
result of normal wear and tear, which is not considered a defect in
materials or workmanship and therefore is not covered by the
warranty.
This warranty gives you specific rights, and you may also have other
rights which vary from state to state. If unit should prove defective
within the warranty period, return within the time period set forth
above prepaid with the original purchase receipt to:
Prime Wire & Cable, Inc.
ATTN: Timer Warranty
280 Machlin Court
City of Industry, CA 91789
Service - (888) 445-9955 • www.primewirecable.com
SAFETY INFORMATION & SPECIFICATIONS
THIS TIMER IS A “GROUNDED” DEVICE. The male
plug contains a ground pin and is only intended for
use with a three-pronged grounded outlet.
THIS TIMER IS FOR USE WITH A 125VAC POWER SOURCE.
125VAC / 60Hz
DO NOT ATTACH A DEVICE THAT EXCEEDS THE UNIT
RATINGS:
15A / 1875W Resistive (General Purpose)
8A / 1000W Tungsten (Incandescent)
1/3 HP (Horsepower Motor)
Table of contents
Other Prime Wire & Cable Timer manuals
Popular Timer manuals by other brands

Competition Electronics
Competition Electronics ProTimer BT operating manual

TFA
TFA 38.2027 operating instructions

NSI
NSI Tork SA130 Programming instructions

Busch-Jaeger
Busch-Jaeger Busch-Timer 6455 operating instructions

Tempatron
Tempatron UMT500 manual

Stanley
Stanley TimerMax Digislims TM213 user manual