Pro-face RS-232C User manual

1
RS-232C/485 Isolation Unit
Installation Guide
Thank you for purchasing Pro-face's RS-
232C/485 Isolation Unit (CA3-ISO232-01/
CA3-ISO485-01). This unit is designed to
utilize Pro-face product, Display(Unit) serial
interface connector (D-Sub 9-pin), and
electrically separates the serial interface
signal from the Display's chassis.
For the details of the applicable models,
please refer to each Display's Hardware
Manual or Pro-face Home Page.
http://www.pro-face.com/
Global Code
A global code is assigned to every Pro-face
product as a universal model number.
For more information on product models and
their matching global codes, please refer to
the following URL.
http://www.pro-face.com/product/globalcode.html
Safety Precautions
• When disposing of this product, be
sure to do so according to your
country's standards for industrial waste
disposal.
Package Contents
(1) Isolation Unit
RS-232C Isolation Unit CA3-ISO232-01
RS-485 Isolation Unit CA3-ISO485-01
(2) Attachment Screws (2)
(3) Installation Guide <this document>
This product has been carefully packed with
special attention to quality. However, should
you find anything damaged or missing,
please contact your local distributor.
WARNING
HAZARD OF ELECTRIC SHOCK OR EXPLO-
SION
• To avoid an electric shock, prior to connecting
this unit to the Display's serial interface, con-
firm that the Display's power supply is com-
pletely turned OFF, via a breaker, or similar
unit.
• Do not modify this unit. Doing so may cause
a fire or an electric shock.
• Do not use this unit in an environment where
flammable gases are present, since operat-
ing this unit may cause an explosion.
• Do not allow water, liquids, metal or charged
particles to enter inside this unit, since they
can cause either a unit malfunction or an
electrical shock.
Failure to follow these instructions can result
in death, serious injury, or equipment damage.
WARNING
UNINTENDED EQUIPMENT OPERATION OR
LOSS OF CONTROL
• Do not use or store this unit in direct sunlight,
in excessively dusty or dirty environments or
where excessive vibration can occur.
• Do not store or use this unit where strong jolt-
ing can occur.
• Do not store or use this unit where chemicals
(such as organic solvents, etc.) and acids can
evaporate, or where chemicals and acids are
present in the air.
Failure to follow these instructions can result
in death, serious injury, or equipment damage.

2
Dimensions
Units: mm [in.]
General Specifications
Electrical Specifications
RS-232C Isolation Unit RS-485 Isolation Unit
AInput
(Display Side)
Communication
Method RS-232C RS-485
Interface D-Sub 9-pin socket D-Sub 9-pin plug
BOutput
(PLC Side)
Communication
Method RS-232C / RS-422
(via DIP Switch) RS-485 / RS-422
(via DIP Switch)
Interface D-Sub 9-pin plug D-Sub 9-pin socket
Power
Supply
Rated Input Voltage DC 5V (supplied from the Display)
Input Voltage Limits 1.25 W or less
Input Voltage Endurance AC1000V 20mA 1min(When attached to the Display)
Insulation Resistance DC500V 10MΩor higher(When attached to the
Display)
110[4.33]
40[1.57]
27[1.06]
PLC Display
to
to
AGP
AGP
420[16.54] 48[1.89]
to
to
AGP
AGP
31
[1.22]
B
A

3
Environmental Specifications
External Specifications
Serial Interface Specifications
RS-232C Isolation Unit
The RS-232C/RS-422 type.
D-Sub 9-pin plug connector's pin assignments are as follows.
Use the DIP switch on the unit to change communication methods.
• For Display side settings please refer to “Display side settings”.
Physical Environment
Ambient Operating
Temperature 0...50 °C (32...122 °F)
Storage Temperature -20...60 °C (-4...140 °F)
Ambient and Storage
Humidity 10...90 % RH (Non condensing, wet bulb
temperature 39 °C [102.2 °F] or less)
Dust 0.1 mg/m3(10-7 oz/ft3) or less (non-conductive levels)
Pollution Degree For use in Pollution Degree 2 environment
Atmosphere Free of corrosive gases
Atmospheric Pressure
(Operating Altitude) 800...1114 hPa (2000 m [6561 ft] or lower)
Mechanical
Environment
Vibration Resistance
IEC/EN 61131-2 compliant
5...9 Hz Single amplitude 3.5 mm (0.14 in.)
9...150 Hz Fixed acceleration: 9.8 m/s2
X, Y, Z directions for 10 cycles (100 min.)
Concussion Resistance IEC/EN 61131-2 compliant
(147 m/s2, X, Y, Z directions for 3 times)
Electrical
Environment
Noise immunity
Noise Voltage: 1000 Vp-p
Pulse Width: 1 µs
Rise Time: 1 ns
(via noise simulator)
Electrostatic Discharge
Immunity Contact Discharge Method: 6 kV (IEC/EN61000-4-2
Level 3)
Cooling Method Natural air circulation
Weight 170 g (0.37 lb) or less
External
Dimensions W110 x H40 X D27 mm (W4.33 x H1.57 x D1.06 in.)
RS232C
RS422

4
RS-232C
RS-422
Unit's Connector : XM2C-0942-132L<made by OMRON>
Recommended Connector : XM2D-0901 <made by OMRON>
Recommended Cover : XM2S-0913 <made by OMRON>
Jack Screw : XM2Z-0073 <made by OMRON>
Stacking Metal Fittings require #4-40 inch screw.
• This unit does not correspond to RS-422/485 (2 wire) communication.
• This unit does not correspond to Serial Multilink communication.
Pin Arrangement Pin # RS-232C
Signal Name Direction Meaning
1 CD Input Carrier Detect
2 RD (RXD) Input Receive Data
3 SD (TXD) Output Send Data
4 ER (DTR) Output Data Terminal Ready
5 SG - Signal Ground
6 DR (DSR) Input Data Set Ready
7 RS (RTS) Output Request to Send
8 CS (CTS) Input Clear to Send
9 NC - No connection
Shell FG - Frame Ground
Pin Arrangement Pin # RS-422
Signal Name Direction Meaning
1 RDA Input Receive Data A(+)
2 RDB Input Receive Data B(-)
3 SDA Output Send Data A(+)
4 ERA Output Data Terminal Ready A(+)
5 SG - Signal Ground
6 CSB Input Send Possible B(-)
7 SDB Output Send Data B(-)
8 CSA Input Send Possible A(+)
9 ERB Output Data Terminal Ready B(-)
Shell FG - Frame Ground
5
16
9
5
16
9

5
RS-485 Isolation Unit
The RS-485/RS-422 type.
D-Sub 9-pin socket connector's pin assignments are as follows.
The communication method is switched with a change switch.
• For Display side settings please refer to “Display side settings”.
• This unit can not be used for GP4000 Series.
RS-485
Pin Arrangement Pin # RS-485
Signal Name Direction Meaning
1TRMRX - Termination
(Receive side: 100Ω)
2RDA / SDA --
3Input /
Output Receive Data A(+) /
Send Data A (+)
4 NC - No connection
5 SG - Signal Ground
6VCC - +5V±5% output 0.05A*1
*1 The VCC output for Pin #6 is not protected against overcurrent. To prevent
damage or unit malfunctions, use only the rated current.
7RDB / SDB --
8Input /
Output Receive Data B(-) /
Send Data B(-)
9 TRMTX - Termination (Send side: 100Ω)
Shell FG - Frame Ground
RS422
RS485
5
16
9

6
RS-422
Unit's Connector : XM3B-0942-132L<made by OMRON>
Recommended Connector : XM2A-0901 <made by OMRON>
Recommended Cover : XM2S-0913 <made by OMRON>
Jack Screw : XM2Z-0073 <made by OMRON>
Stacking Metal Fittings require #4-40 inch screw.
Attachment Method
• For the GP-4200 series, attach the unit to the panel.
Attaching the Unit directly to the Display
When attaching the unit on the rear side of the Display, among the 4 screws shown in the diagram
below, use 2 horizontally positioned or 2 vertically positioned screws to attach the unit. If the
Display already has an attachment, it may restrict the direction in which you can place the unit.
Pin Arrangement Pin # RS-422
Signal Name Direction Meaning
1TRMRX - Termination
(Receive side: 100Ω)
2 RDA Input Receive Data A(+)
3 SDA Output Send Data A (+)
4 NC - No connection
5 SG - Signal Ground
6VCC - +5V±5% output 0.05A*1
*1 The VCC output for Pin #6 is not protected against overcurrent. To prevent
damage or unit malfunctions, use only the rated current.
7 RDB Input Receive Data B(-)
8 SDB Output Send Data B(-)
9 TRMTX - Termination (Send side: 100Ω)
Shell FG - Frame Ground
5
16
9
75[2.95]
75[2.95]
EXT*

7
1) Attach one screw to the Display's rear side.
Use a torque of 0.5 N•m to 0.6 N•m (4.4 lb-in
to 5.3 lb-in).
2) Attach the unit to the Display.
3) Slide the unit in the direction of the arrow
so the unit is hooked by the screw from step1.
4) Fix the unit in place with another screw.
Use a torque of 0.5 N•m to 0.6 N•m (4.4 lb-in
to 5.3 lb-in).
• When attaching the unit to the Display, be
careful with the attachment position.
• Attach the unit to a stable surface. Do not
leave the unit hanging by its cord.
• Be careful with wire placement.
Overlapping cords may cause noise.
• When attaching another unit to the
Display, be careful of the place for the
attachment.
• If this unit and Pro-face Product, VM Unit
(GP2000-VM41) are attached to AGP-
35*0T at the same time, only when this
unit is attached in the position as shown
below, it's possible to attach the VM Unit
with it at the same time.
• Make sure the unit is placed inside the
edges of the Display.
Correct
Incorrect
• Do not place the unit over the slits.
Correct
Incorrect
Rear face of Display
Rear face of Display
Rear face of Display
Rear face of Display
to
to
AGP
AGP
VM Unit
to
to
AGP
AGP
to
to
AGP
AGP
to
to
AGP
AGP
to
to
AGP
AGP

8
Attaching the Unit to a Panel
When attaching the unit to a panel other than
the Display’s main unit, attach it at the two
points identified in the diagram below. Drill
holes suitable for screws as shown in the
diagram. For attachment information, refer to
“Attaching the unit directly to the Display”.
Unit mm:[in.]
Display side settings
When connecting the RS-232C isolation unit,
the following two settings are made in the
Display's Offline mode or using the screen
creation software.
• Setting the Display's communication
method to RS-232C
• Setting the Serial Interface port's number
9 pin to VCC
In the case of the operation in the Offline
mode, change it with [Peripheral Settings] of
[Device PLC/Settings]. For the software's
operation, refer to “Device/PLC Connection
Manual”.
CE Marking
• The CA3-ISO232-01 and CA3-ISO485-
01 are a CE marked, EMC compliant
products.
These units conform to EN55011 Class A
and EN61000-6-2 directives.
Digital Electronics Corporation
8-2-52 Nanko-higashi
Suminoe-ku, Osaka 559-0031
JAPAN
TEL: +81-(0)6-6613-3116
FAX: +81-(0)6-6613-5888
http://www.pro-face.com/
© Copyright 2006 Digital Electronics
Corporation. All rights reserved.
75[2.95]
2-M3[0.12] or less
φ
9±
0.1[0.35±0.00]
0.7±
0.1[0.03±0.00]
(2.7[0.11])
φ
6.5±
0.1
3.3±
0.05[0.13±0.00] 4+0
-0.2
M3 SCREW
[0.16 ]
+0.00
-0.01
[0.26±0.00]
Inquiry
If you experience difficulties or have
questions about this product, please
contact us any time.
You can access our support site
“Otasuke Pro!” whenever you need
help with a solution.
http://www.pro-face.com/otasuke/
Please be aware that Digital Electronics
Corporation shall not be held liable by the
user for any damages, losses, or third-
party claims arising from the use of this
product.
Note