Specification
Troubleshooting
www.procetpoe.com
Input
PoE Standard
Class Level
PoE Power Pins
Work Temp.
50-57Vdc 2.0A
IEEE802.3 af/at/bt
Class 8
Network Protocol RJ45:100M/1000M/2.5G/5G/10G,SFP:10G
Data Speed
IEEE802.3u/ab/bz/an IEEE802.3ae
Output
PT-PSE105GBS-D-10
EMC
Dimensions & NW 144.5mm X 95mm X 35.4mm 485g
Failure
Phenomena Cause Analysis Solutions
Power LED
Light off
Not plugged in / no power Plug in the power cord
Load
Indicator
Light Off
EN 55032:2015/A11:2020 EN 55035:2017/A11:2020
Model
4/5(+),7/8(-)& 3/6(+),1/2(-)
Poor Power outlet
Poor Power cord
Power cable is not plugged in
-40°C to 65
48-55Vdc 1750mA
°C
firmly
Check if the socket connection
is loose, if the AC cable is
damaged, or if the power
supply is abnormal.
Device issues Device replacement
Poor network cable contact or
network cable failure.
Non-PoE compliant PD or
unsupported PD or
Re-plug the network cable
or replace the network
cable.
mismatched PD PD replacement
PD Damage PD replacement
Check if the total length of the
network connection cable exceeds
100 meters.
Shorten the connection
distance, or add an extender/
repeater.
SFP port signal source malfunction Check if the switch working
properly.
Ethernet data transmission failure
Data
Transmission
Check if the cable comply with
the EIA/TIA568B or 568A.
Change good network cable if
the previous cable is poor.
Abnormality
Caution
1. Please read the instructions carefully and follow the
standard operating procedures before using.
2. Please place it in a well-ventilated and dry area, and it is
for indoor use only.
3. Connect the DC power cable with positive and negative
wires into the DC terminal block of Procet Injector.
4. Connect a fiber cable with SFP+ optical module at 10G
from your switch into the injector's SFP slot for data Input.
(The optical module does not include in the package). You
can choose either single-mode or multi-mode SFP
transceivers.
5. Connect a CAT6 cable with the RJ45 connector into the
RJ45 socket labeled PoE. On the other end of the CAT6
cable, connect to your PoE Device (such as IP Cameras etc)
. The total Ethernet cable length can not exceed 100
meters.
6. The device must be placed on a stable surface,
preferably affixed and mounted permanently. Do not
leave it "dangling" and use plugged-in cables in tension
as support. Drops, falls, and impacts experienced by the
injector can compromise the internal components & cause
premature failure.
7. Do not place heavy objects on top of this injector. Allow
at least 5cm of clearance on all sides of the device for
heat ventilation / natural convection.