special hazards
temperature measurement
staff qualification
- The sensor has been designed exclusively for the intended use described here or in the
datasheet and may only be used in this way.
- The technical specifications contained in these operating instructions must be observed.
- Improper handling or operation of the device outside of its technical specifications
requires the device to be taken out of service immediately and an inspection by
promesstec.
- When the device is transported from a cold into a warm environment the formation
of condensation may result in the device malfunctioning.
- Before putting it back into operation wait for the device temperature and the room
temperature to equalise.
The manufacturer shall not be liable for claims of any type based on operation contrary
to the intended use!!
hazards when operating the device
promesstec GmbH * Niedersachsenstraße
4 * 48465 Schüttorf * T
el.:+49 (0)5
923/ 90229
-0 * Fax +49 (0)5923/
90229-29 * E-Mail:
[email protected] * Internet: www
.promesstec.com
short manual resistance thermometer WTR 190
intended use of the product
safety instructions !!!
page 1/4
Improper handling can result in considerable personal injury and damage to equipment.
The activities described in these operating instructions may only be carried out by skilled
staff who have the appropriate qualifications. For installation and starting of the sensor
the relevant regulations and directives of the country and the norms must be observed.
Especially during installation of the sensor it is possible depending on the use to come
into contact with aggressive media. The safety instructions must be observed. There will
be danger to life if live parts are touched. Electrical installation and commissioning may
only be carried out by qualified and skilled personnel.
Residual media in dismantled devices can endanger persons the environment and
equipment. Sufficient precautionary measures must be taken here. The devices must
not be used in safety or emergency stop equipment. Incorrect application or operation
of the device can lead to injuries. Depending on the application aggressive media with
extreme temperatures and high pressure or vacuum may be present at the device in the
event of a fault. We recommend installing and removing the device only at ambient
temperature and in a depressurized state.
Our units have a very high protection class when properly assembled and installed.
When cleaning your unit with high-pressure cleaners steam cleaners etc. make sure
that both the cover and the cable gland are not directly exposed to the pressure jet. If
the temperature falls below the dew point condensation may form in the terminal
compartment of the unit. For such extreme applications contact our sales and technical