
Page 3 of 121
8COMMISSIONING ...........................................................................................................................................54
8.1 SWITCH-ON BEHAVIOR DURING COMMISSIONING................................................................................................54
8.2 DEFINING METERING AND CONTROL PROCESSES.............................................................................................54
9PROGRAMMING THE INPUTS.......................................................................................................................54
9.1 ANALOG AND DIGITAL INPUTS ..........................................................................................................................55
9.1.1 Enable an Analog or Digital Input: ...........................................................................................................55
9.1.2 Enable a CTFS [Conductivity, Temp, Flow, Serial] Sensor .....................................................................56
9.2 CHANGING A DESCRIPTOR...............................................................................................................................57
9.3 SELECTING AN ANALOG SENSOR TYPE.............................................................................................................57
9.3.1 Selecting the sensor type:........................................................................................................................57
9.4 ANALOG SENSOR CLEANING AND CALIBRATION ................................................................................................59
9.4.1
Generalremarks
......................................................................................................................................59
9.4.2 Sensor Commissioning............................................................................................................................59
9.4.3
Calibrating and checking probes
............................................................................................................59
9.4.3.1
Calibrating pH probes
.....................................................................................................................59
9.4.3.2
Checking redox/ORP probes
.........................................................................................................59
9.4.4 Cleaning and servicing probes................................................................................................................60
9.4.4.1
Storage
............................................................................................................................................60
9.4.4.2 Service life........................................................................................................................................60
9.4.5 Calibration Notes......................................................................................................................................61
9.5 GENERAL SENSOR CALIBRATION .....................................................................................................................61
9.6 CALIBRATING AN AMPEROMETRIC SENSOR.......................................................................................................63
9.7 ANALOG SENSOR ALARMS...............................................................................................................................64
9.7.1 Analog Alarm Configuration.....................................................................................................................64
9.8 ANALOG SENSOR DIAGNOSTICS.......................................................................................................................65
9.8.1 pH-ORP Driver card Diagnostics .............................................................................................................66
9.8.2 CT (Conductivity, Boiler Cond., Condensate and Temperature) Driver card Diagnostics.......................66
9.8.3 The 4-20mA Input Driver Card Diagnostics .............................................................................................66
9.8.4 The 4-20mA output Driver Card Diagnostics...........................................................................................67
9.8.5 Serial Sensors (CTFs, LPR, DP) Driver Card Diagnostics ......................................................................67
9.9 CONFIGURING DIGITAL INPUTS.........................................................................................................................68
9.9.1 Configure a Digital Input as a Water Meter:.............................................................................................68
9.9.2 Link a Water Meter to a Relay (Applies to all relays )..............................................................................69
9.10 FAIL TO FEED (FEED VERIFICATION)............................................................................................................70
9.11 DISABLE AN ANALOG OR DIGITAL INPUT.......................................................................................................71
9.11.1 Changing or Unlinking an Analog Input Tied to an Output Relay ............................................................72
9.11.2 Changing or Unlinking Analog Inputs Tied to a 4-20mA Output:.............................................................73
9.11.3 Changing or Unlinking a Digital Input Tied to a Digital Output.................................................................73
9.11.4 Changing or Unlinking a Digital Input Tied to a 4-20mA Output..............................................................74
9.12 PHANTOM INPUTS.......................................................................................................................................74
10 PROGRAMMING THE CONTROL OUTPUTS (RELAY AND 4-20MA).........................................................74
10.1 FREQUENCY/PULSE OUTPUTS:....................................................................................................................75
10.2 DETERMINE IF A RELAY IS ENABLED:............................................................................................................75
10.3 ENABLE AND CONFIGURE A RELAY ..............................................................................................................75
10.4 NAMING THE OUTPUT .................................................................................................................................76
10.5 CONFIGURING A BLOWDOWN RELAY............................................................................................................77
10.6 CONFIGURING A FEED RELAY......................................................................................................................77
10.6.1 Feed Based on a Water Meter.................................................................................................................78
10.6.2 Feed Based on a Sensor .........................................................................................................................78
10.6.3 Feed Based on Bleed and/or Feed..........................................................................................................79
10.6.3.1 Bleed then Feed...............................................................................................................................79
10.6.3.2 Bleed and Feed................................................................................................................................79
10.6.4 Feed Based on Percent Time & Base Feed ............................................................................................80
10.6.5 Feed Based on a Sensor with Event Control...........................................................................................80
10.6.6 Set up a relay using the Feed mode with an oxidant sensor; ORP or any 4-20mA input........................80
10.6.7 Choosing a Cycle.....................................................................................................................................80
10.7 CONFIGURING AN EVENT-OTHER RELAY......................................................................................................81
10.7.1 Schedules, Prebleeding, Lockout and With a Sensor..............................................................................81
10.7.1.1 Prebleed/Lockout .............................................................................................................................82
10.7.2 Add, Remove, Edit Events .......................................................................................................................83