  9. ProMinent DCM 5 Series User manual

ProMinent DCM 5 Series User manual

Visit our XTRANET <www.prominentxtranet.com> to:
• sign up for our electronic newsletter • download literature and manuals • validate your product warranty
BACK ENTER
ProMinent®
OK
ALARM Pool 750.0mV
7.40pH 85.0F
BACK ENTER
ProMinent®
OK
ALARM Pool 750.0mV
7.40pH 85.0F
BACK ENTER
ProMinent®
OK
ALARM
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ER
ER
ER
ER
ER
ER
ER
ER
ER
ER
ER
Editing, or Exit
7.40 pH
BACK ENTER
ProMinent®
OK
ALARM
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ER
ER
ER
ER
ER
ER
ER
ER
ER
ER
ER
Oxidant Pump_3 3
OFF: ppm control
BACK ENTER
ProMinent®
OK
ALARM
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ER
ER
ER
ER
ER
ER
ER
ER
ER
ER
ER
Editing, or Exit
7.40 pH
BACK ENTER
ProMinent®
OK
ALARM
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ER
ER
ER
ER
ER
ER
ER
ER
ER
ER
ER
Editing, or Exit
1.40 pH
BACK ENTER
ProMinent®
OK
ALARM
BA
BA
BA
BA
BA
BA
BA
BA
BA
BA
BA
CK
CK
CK
CK
CK
CK
CK
CK
CK
CK
CK
C
pH Sensor A
7.40 pH
BACK ENTER
ProMinent®
OK
ALARM
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ER
ER
ER
ER
ER
ER
ER
ER
ER
ER
ER
ER
Editing, or Exit
1.50 pH
CAUTION
Before attempting calibration or commissioning of the DCM5 controller, water chemistry must be stable and within normal ranges
of 7.2-7.8 pH, Total Alkalinity 80-120 ppm, Free Chlorine 1-2 ppm
pH Calibration Adjusting Pump Setpoints
(Residual and Temperature calibrations are performed in the same
manner from their respective sensor menus, but eld ORP calibrations
are not normally needed.)
1. Perform a pH test and NOTE the results Note: “Turn OFF Setpoint” is the ideal point where chemical
control is achieved and “Turn ON Setpoint” is the point used to
dene the on/off deadband or proportional span needed.
2. Press 2 times
[Oxidant]
[pH Sensor_C] 1. Press 5 times
[pool Oxidant]
[pH Sensor]
[Acid Pump]
[ORP Sensor_D]
[Oxidant Pump_3]
3. Press 3 times
[Editing, ⏎ or Exit]
[Calibrate]
[Enter Value]
2. Press 3 times to
change the Turn ON
Setpoint [Editing, ⏎
or Exit]
4. Press to
adjust displayed value
to match the tested
value, then press
to accept the change
3. Press to
adjust the Turn ON
Setpoint, usually one
or two units (0.1 ppm)
below the Turn OFF
setpoint for Oxidant
feed systems. Then
press to accept the
new value.
5. Press to return
to the main status
screen
5. Press to
adjust the “Turn OFF
Setpoint”. This is the
point where oxidant
feed is satised, and
considered by most to
be the setpoint when
only 1 setponit is
used. Then press
to accept the new
value.
4. Press then to
change the Turn OFF
Setpoint. (Default is
1.5ppm)
6. Pressing BACK returns to the main status screen
2
1
2
3
5
3
4
5
DCM5_QSG.indd Rev1 (09/25/2012)(p/n: 7500581)
DCM 5 Series Controller
Quick Start Guide
BACK ENTER
ProMinent®
OK
ALARM Pool 750.0mV
7.40pH 85.0F
BACK ENTER
ProMinent®
OK
ALARM Pool 750.0mV
7.40pH 85.0F
BACK ENTER
ProMinent®
OK
ALARM Pool Oxidant
OFF: Setpoints
BACK ENTER
ProMinent®
OK
ALARM Oxidant Pump 3
OFF: Setpoints
BACK ENTER
ProMinent®
OK
ALARM Alarms
A B 1 2
BACK ENTER
ProMinent®
OK
ALARM
ENTER
Oxidant Pump 3
Auto OFF ON
BACK ENTER
ProMinent®
OK
ALARM
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ENT
ER
ER
ER
ER
ER
ER
ER
ER
ER
ER
Pool 750.0mV
7.40pH 85.0F
Alarm Information
Clear (Reset) All Alarms
Changing a Pump/Feeder
Auto to Off - Manual ON
Relays 1 and 3 are factory set as Acid Pump and Oxidant
Pump, using pH Sensor C, and ORP Sensor D, respectively.
They are default in the AUTO mode for ON/OFF control to 7.4
pH and 750mV. They can be set to the on mode for priming or
to the OFF mode to temporarily disable chemical feed.
If the orange ALARM light is ashing, an alarm has activated.
1. Choose the relay you
want to change by
pressing the button
until the selected
(relay 1 or 3) is
shown.
1. Press once to
view active alarms.
The LCD screen will
alternately show the
oxidant feeder status
along with any inputs
(letter) or outputs
(numbers) that have
alarmed.
Note: Alarms may have
been corrected and the
alarm just may need to
be acknowledged.
2. Press and hold the
button and the display
will change to show
⏎AUTO ↓OFF ↑ON
while the button is
held down.
1. When the alarm light
is ashing and you
just want to
acknowlege and clear
the alarms, press
then twice.
[Alarm Status Screen]
[Alarm Menus]
[Clear Alarms]
3. While holding the
button, pressing one
of the three other
buttons , or
will put the output in
that respective mode.
1
1
2
3
3
4
1
DCM 5 Series Controller
Quick Start Guide
The default timeout for the forced ON condition is 10 minutes.
After that delay, the relay will revert to AUTO mode. To adjust
this time, refer to the install manual or ask your ProMinent
Distributor for assistance.
ProMinent Fluid Controls, Inc.
136 Industry Drive • Pittsburgh, Pa 15275
Ph: 412-787-2484 • Fx: 412-787-0704
eMail: [email protected]
www.prominent.us

Other ProMinent Controllers manuals

ProMinent DULCOMETER D2C User manual

ProMinent

ProMinent DULCOMETER D2C User manual

ProMinent DULCOMETER User manual

ProMinent

ProMinent DULCOMETER User manual

ProMinent DCM 2 Series User manual

ProMinent

ProMinent DCM 2 Series User manual

ProMinent DULCOMETER User manual

ProMinent

ProMinent DULCOMETER User manual

ProMinent diaLog DACb Wiring diagram

ProMinent

ProMinent diaLog DACb Wiring diagram

ProMinent DULCOMETER D1C User manual

ProMinent

ProMinent DULCOMETER D1C User manual

ProMinent DULCOMETER D2C User manual

ProMinent

ProMinent DULCOMETER D2C User manual

ProMinent DULCOMETER User manual

ProMinent

ProMinent DULCOMETER User manual

ProMinent DCM3 Series User manual

ProMinent

ProMinent DCM3 Series User manual

ProMinent Splash Control Pro 2 User manual

ProMinent

ProMinent Splash Control Pro 2 User manual

ProMinent Splash Control 2 User manual

ProMinent

ProMinent Splash Control 2 User manual

ProMinent DULCOMETER User manual

ProMinent

ProMinent DULCOMETER User manual

ProMinent DULCOMARIN II Wiring diagram

ProMinent

ProMinent DULCOMARIN II Wiring diagram

ProMinent DULCOMETER D1C User manual

ProMinent

ProMinent DULCOMETER D1C User manual

ProMinent DULCOMETER diaLog DACb Planning guide

ProMinent

ProMinent DULCOMETER diaLog DACb Planning guide

ProMinent multiFLEX M10 User manual

ProMinent

ProMinent multiFLEX M10 User manual

ProMinent DULCOMETER D1C User manual

ProMinent

ProMinent DULCOMETER D1C User manual

ProMinent PROFIBUS DP DULCOMETER diaLog DACb Wiring diagram

ProMinent

ProMinent PROFIBUS DP DULCOMETER diaLog DACb Wiring diagram

ProMinent DULCOMARIN II DXM Series Wiring diagram

ProMinent

ProMinent DULCOMARIN II DXM Series Wiring diagram

ProMinent DULCOMETER D1Cb Operator's manual

ProMinent

ProMinent DULCOMETER D1Cb Operator's manual

ProMinent DULCOMETER D1C User manual

ProMinent

ProMinent DULCOMETER D1C User manual

ProMinent DCM510 User manual

ProMinent

ProMinent DCM510 User manual

ProMinent Aegis-II User manual

ProMinent

ProMinent Aegis-II User manual

ProMinent DULCOMETER Compact User manual

ProMinent

ProMinent DULCOMETER Compact User manual

Popular Controllers manuals by other brands

Pilz PSSuniversal multi PSSu H m F DP ETH SD operating manual

Pilz

Pilz PSSuniversal multi PSSu H m F DP ETH SD operating manual

Contrec 414L introduction

Contrec

Contrec 414L introduction

Fuji Electric CC-M instruction manual

Fuji Electric

Fuji Electric CC-M instruction manual

Doms PSS 5000 Technical manual

Doms

Doms PSS 5000 Technical manual

Sit 630 Eurosit quick start guide

Sit

Sit 630 Eurosit quick start guide

Rain Bird ESP-Me user manual

Rain Bird

Rain Bird ESP-Me user manual

BERNSTEIN SCR OM manual

BERNSTEIN

BERNSTEIN SCR OM manual

Ransburg 9060 Service manual

Ransburg

Ransburg 9060 Service manual

Mitsubishi Electric MELSEC-F FX-USB-AW user manual

Mitsubishi Electric

Mitsubishi Electric MELSEC-F FX-USB-AW user manual

Automationdirect.com D4-454 PLC user manual

Automationdirect.com

Automationdirect.com D4-454 PLC user manual

Airwell RCW22 Installation and owner's manual

Airwell

Airwell RCW22 Installation and owner's manual

FMC Technologies Sening EPE2 installation manual

FMC Technologies

FMC Technologies Sening EPE2 installation manual

ROLA-CHEM RC554XXP operating manual

ROLA-CHEM

ROLA-CHEM RC554XXP operating manual

nekos KATO 253 Manual for installation and use

nekos

nekos KATO 253 Manual for installation and use

Novar NOVAR 300 Operation & maintenance manual

Novar

Novar NOVAR 300 Operation & maintenance manual

Lennox LXTFF01M manual

Lennox

Lennox LXTFF01M manual

Shinko ACS-13A-*A Series instruction manual

Shinko

Shinko ACS-13A-*A Series instruction manual

Epson S1D13700 User's & technical manual

Epson

Epson S1D13700 User's & technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.