Prorelax DuoComfort Wireless User manual

1
1639
TENS+EMS
DuoComfort Wireless
KIT
OPERATING INSTRUCTION

2 3
3
Signs and Symbols
4
Package Content
5
Getting to know your Device
7
Important Notes
12
About Remore Control
12
About Receivers
13
About Rechargeable Batteries
13
Charging the Remote Using the AC Adaptor
13
Charging the Receiver
15
Step by Step Operation Guide for Treatment
15
Placement of Electrode
16
Placement of Electrode
17
Turning ON/OFF Remote
17
Turning On/O Receiver
18
Communication between Remote and Receiver(s)
19
Selecting the Program
22
Selecting the Therapy Time
22
Selecting the Therapy Intensity Level
23
Pod Channel Pairing
24
Rechargeable Battery
24
Replacement Parts and Wearing Parts
25
Cleaning and Storage
26
Notes on Electromagnetic Compatibility
26
Disposal
27
Technical Data
28
Warranty
ENGLISH
Read these instructions for use carefully and keep them for
later use, be sure to make them accessible to other users
and observe the information they contain.
Signs and Symbols
WARNING
Warning instruction indicating a risk of injury or damage to health
IMPORTANT
Safety note indicating possible damage to the device/accessory
Note
Note on important information
Observe the instructions for use
IP22
Protected against ingress of solid foreign objects greater than
12.5mm in diameter. Protected against drops of water falling at up to
15° from vertical.
Serial number
Application part, type BF
Disposal in accordance with the Waste Electrical and Electronic
Equipment EC Directive – WEEE
1639
The CE labelling certies that the product complies with the essential requirements
of Directive 93/42/EEC on medical products.
Manufacturer
The manufacturer wants to signal that it complies with the regulations
of the Packaging Ordinance.

4 5
Getting to know your Device
What is a TENS+EMS DuoComfort Wireless unit and what can it
do?
EMS/TENS units fall into the electrostimulation device category. They
provide three basic functions suitable for combined operation:
1. Electrical stimulation of nerve tracts (TENS)
2. Electrical stimulation of muscle tissue (EMS)
3. A massage eect triggered by electrical signals
The unit also features two independent stimulation channels and four self-
adhesive electrodes. It oers a wide range of functions for increasing gene-
ral well-being, pain relief, maintaining physical tness, relaxation, muscle
revitalisation and combating tiredness. For these purposes, you can either
choose from pre-set programs or specify your own to suit your individual
needs.
The principle of electrostimulation devices is based on the imitation of im-
pulses in our bodies that are transferred to nerve and muscle bres using
electrodes via our skin. The electrodes can be applied to many parts of the
body; the electrical impulses are completely harmless and virtually painless.
In certain applications you will merely notice a slight tingling or vibrating
sensation. The electrical impulses that are sent into the tissue inuence the
transmission of stimulation into nerves, nerve centres and muscle groups in
the application area.
Electrostimulation usually only has an eect after regular applications. With
regard to muscles, electrostimulation does not replace regular training.
However, it is a sensible, supplementary training element.
TENS, or transcutaneous electrical nerve stimulation, relates to the electrical
stimulation of the nerves via the skin. TENS is an eective non-pharmacolo-
gical method of treating dierent types of pain that have a variety of causes.
It has no side-eects if administered correctly. The method has been clini-
cally tested and approved and can be used for simple self-treatment. The
pain-relieving or pain-suppressing eect is achieved by inhibiting the trans-
ference of pain to nerve bres (caused mainly by high-frequency impulses)
and by increasing the secretion of endorphins in the body. Their eect on
Package Content
1. Remote 1x
2. Belt Clip 1x
3. Receiver 2x
4. USB Cable x1
5. Electrode (CM13070C)
6. Electrode (CM7070)
7. Adaptor

6 7
the central nervous system reduces the sensation of pain. The method is
scientically substantiated and approved as a form of medical treatment.
Any symptoms that could be relieved using TENS must be checked by your
GP. Your doctor will also give you instructions on how to carry out a TENS
self-treatment regime.
TENS is clinically tested and approved to treat the following
complaints:
• Back pain, particularly in the lumbar/cervical spine area
• Sore joints (e.g. knee, hip and shoulder joints)
• Neuralgia
• Menstrual cramps in women
• Pain resulting from injury to the musculoskeletal system
• Pain caused by circulatory disorders
• Chronic pain with various causes.
Electrical muscle stimulation (EMS) is a widespread and generally recog-
nised method and has been used in sports medicine and rehabilitation
for years. In sports and tness, EMS is used to complement conventional
muscle training, to increase the performance of muscle groups and to ad-
just physical proportions to achieve the desired aesthetic results. There are
two dierent types of EMS application: one is for targeted strengthening of
the muscles (activating application), and the other is to achieve a relaxing,
restful eect (relaxing application).
The activating application involves:
• Muscle training to increase endurance and/or
• Muscle training to support the strengthening of specic muscles or muscle
groups, and to achieve the desired changes to physical proportions
The relaxing application involves:
• Muscle relaxation for easing muscle tension
• Improving symptoms of muscular fatigue
• Acceleration of muscle regeneration after high muscle performance (e.g.
after a marathon)
Thanks to integrated massage technology, TENS+EMS DuoComfort Wireless
units are also able to relieve muscle tension and combat fatigue with a pro-
gram based on the sensation and eects of a real massage.
The positioning suggestions and program tables in these instructions for
use allow you to quickly and simply determine the corresponding applicati-
on (depending on the aected area of the body) and set the unit to achieve
the desired eects.
Thanks to the two separately adjustable channels, the TENS+EMS DuoCom-
fort Wireless unit oers you the advantage of being able to set the intensity
of the impulses independently from each other for two treatment areas on
the body, for example to cover both sides of your body or to evenly stimula-
te larger areas of tissue. The option to individually set the intensity of each
channel also enables you to treat two separate areas of the body simulta-
neously instead of having to treat the individual areas in turn, which saves
you time.
Important Notes
The device is not a substitute for medical consultation and treatment. Con-
sult your doctor rst if you are experiencing any pain or are suering from
an illness.
WARNING!
To avoid damage to health, we strongly advise against using the TENS+EMS
DuoComfort Wireless unit in the following situations:
• With implanted electrical devices (such as a pacemaker)
• In the case of metal implants
• If you use an insulin pump
• If you have a high temperature (e.g. > 39°C)
• If you have a known or acute cardiac arrhythmia, or disorders of the
heart’s impulse and conduction system
• If you suer from a seizure disorder (e.g. epilepsy)
• If you are pregnant
• If you have cancer
• After an operation, if strong muscle contractions could aect the healing
process
• The device must never be used near to the heart. The stimulation elec-
trodes must not be placed on any part of the front ribcage (where the

8 9
ribs and breastbone are located), especially not on the two large pecto-
rals. this can increase the risk of ventricular brillation and induce cardiac
arrest.
• On the skeletal skull structure, or around the mouth, throat or larynx
• In the neck/carotid artery area
• In the genital area
• On acutely or chronically diseased (injured or irritated) skin (e.g. inamed
skin – whether painful or not, reddened skin, rashes, e.g. allergies, burns,
bruises, swellings, both open and healing wounds, and post-operative
scars where the healing process could be aected)
• In humid environments (e.g. in the bathroom) / when bathing or showering
• Do not use after consuming alcohol
• If connected to a high-frequency surgical device
• In the case of acute or chronic diseases of the gastrointestinal tract
• The stimulation should not be applied above or through the head, direct-
ly onto the eyes, covering the mouth, to the front of the neck (especially
not to the carotid artery), or with the electrode surfaces placed on the
chest and upper back or across the heart.
Before using the device, consult your doctor if any of the following
applies to you:
• Serious illnesses, in particular if you suspect or have been diagnosed
with high blood pressure, a blood coagulation disorder, propensity to
thrombo-embolic conditions or recurrent malignant growths
• Any skin conditions
• Unexplained chronic pain in any part of the body
• Diabetes
• Any sensory impairment that reduces the feeling of pain (e.g. metabolic
disorders)
• If you are receiving medical treatment
• In the event of complaints linked to stimulation treatment
• If you suer from persistently irritated skin due to long-term stimulation
at the same electrode site
IMPORTANT!
Only use TENS+EMS DuoComfort Wireless units:
• On adults
• For the intended purpose and as specied in these instructions for use.
Improper use can be dangerous.
• For external use
• With the original accessories supplied, which can be re-ordered. Failure
to do so invalidates the warranty.
PRECAUTIONS:
• Always pull rmly on electrodes to remove them from the skin to prevent
injuries in the unusual case of highly sensitive skin.
• Keep the device away from sources of heat and do not use it in close
proximity (approx. 1 m) to shortwave or microwave devices (e.g. mobile
phones), as doing so can result in unpleasant current peaks.
• Do not expose the device to direct sunlight or high temperatures.
• Protect the device from dust, dirt and humidity.
• Never immerse the device in water or other liquids.
• The device is suitable for self-treatment.
• For hygiene reasons, the electrodes may only be used on one person.
• If the device does not work properly, or you feel unwell or experience
pain, stop using it immediately.
• Switch o the unit or the respective channel rst before removing or re-
locating electrodes to prevent unintentional stimulation.
• Do not modify electrodes (e.g. by cutting them). This increases the
current intensity, which is potentially hazardous (max. recommended
output value for the electrodes is 9 mA/cm², an eective current intensity
beyond 2 mA/cm² requires increased awareness).
• Do not use the device whilst asleep, driving a vehicle or operating machi-
nery.
• Do not use whilst undertaking any activity where an unexpected reaction
(e.g. strong muscle contractions even at low intensity) could be dange-
rous.
• Ensure that no metallic objects (e.g. belt buckles or necklaces) come
into contact with the electrodes during stimulation. If you are wearing

10 11
jewellery or have piercings in the area to be treated (e.g. a navel piercing),
these must be removed before using the device. Failure to do so could
result in spot burns.
• Keep the device away from children.
• Make sure not to confuse the electrode cables including contacts with
your headphones or other devices and do not connect the electrodes to
other devices.
• Do not use the device whilst using other devices that transmit electrical
impulses into your body.
• Do not use in the vicinity of highly ammable substances, gases or ex-
plosives.
• Do not use rechargeable batteries and always use the same battery types.
• During the initial few minutes, use the device while sitting or lying down
to minimise the risk of injuries as a consequence of isolated cases of vagal
responses (feeling of faintness). If you feel faint, immediately switch o
the device, lie down and support the legs in an elevated position (approx.
5-10 min).
• Treatment of the skin with moisturising lotions or ointments beforehand
is not recommended as this considerably increases the electrode wear
and may cause unpleasant current peaks.
• This device is not intended for use by people with restricted physical, sen-
sory (e.g. reduced sensitivity to pain) or mental skills or a lack of experien-
ce and/or lack of knowledge, unless they are supervised by a person who
is responsible for their safety or are instructed by such a person in how to
use the device.
• If the adhesive capability of the adhesive electrodes decreases, please
replace them immediately. Only use the device again with new adhesive
electrodes. Otherwise the unequal adhesion of the adhesive electrodes
may lead to skin injuries. Replace the electrodes with new ones after
having used them 20 times at the latest.
Damage
• If the device is damaged, do not use it and contact your retailer or the
specied Customer Services address.
• In order to perform the eectiveness of function by the device, do not
drop the device or disassemble the device.
• Check the device for signs of wear and tear or damage. If there are such
signs of wear and tear or damage or if the device was used improperly, it
must be returned to the manufacturer or retailer before further use.
• Switch the device o immediately if it is faulty or not working properly.
• Do not attempt to open and/or repair the device yourself. Repairs may
only be carried out by Customer Services or authorised retailers. Failure
to comply will result in voiding of the warranty.
• The manufacturer is not liable for damage resulting from improper or
careless use.

12 13
About Remore Control
1. Up key: increase
2. CH key
3. Down key: decrease
4. SET key
5. Power ON/OFF
6. USB charger socket
About Receivers
7. CH1-Receiver: Power On/O key
8. CH2-Receiver: Power On/O key
9. Snaps for Electrode
10. USB charger socket
About Rechargeable Batteries
Please fully charge the batteries in both the remote unit and the receivers before
using this device.
Charging the Remote Using the AC Adaptor
1. Connect the small end of the USB cable to the remote and the larger end to the
AC adaptor.
2. Plug the adaptor into any standard wall outlet.
When the remote has nished charging the battery an icon will indicate “full”.
Charging the Receiver
1. Connect the small end of the USB cable to the receiver and the other end into the
AC adaptor.
2. Plug the adaptor into any standard wall outlet.
Orange light indicates the receiver is now in charge mode, once fully charged
the Orange light will change to Green indicating that the receiver is fully
charged.

14 15
Note: For important precautions for use with AC adaptor, please be informed:
To prevent the risk of electric shock, make sure power cord is unplugged from wall sock-
et. To fully disengage the power to the unit, please disconnect the power cord from
the AC outlet. Do not remove cover (or back). No user serviceable parts inside. Refer
servicing to qualied service personnel. The AC outlet shall be readily available and
accessible.
Note: For important precautions regarding the batteries please
be informed:
• It is recommended to use a manufacturer supplied or approved battery charger in
order to maximize battery life.
• Do not connect the battery to metal objects placed in your pocket or backpack or
other containers.
• Do not short the metal (+)(-) terminals. Wishing to put batteries or electrical
devices do not end when (+)(-) device error.
• Do not dismantle or modify the battery.
• Please do not take a hammer or other items to hammer blow, or throw batteries
and trampling, falls, and fall causing a strong impact, heavy blow, etc.
• Do not use sharp utensils or metal objects to scratch or puncture the battery.
• Do not place the battery into a microwave, oven, or dryer. Do not place the battery
into high-pressure or high temperature environments.
• Do not mix this product with other brands or other types of batteries
• Before charging or discharging the battery, read the manual.
• Stay away from conductive objects during battery charging and discharging.
• Keep batteries away from children.
• When the device(s) system is not in use, store in a low humidity, low temperature
environment.
• In the event the battery uid comes into contact with your eyes, do not rub your
eyes. Rinse with water and immediately seek treatment.
• If you detect abnormal heat, odors, or ames coming from the battery, discontinue
using the battery.
• If the battery uid leaks and comes into contact with the skin, wash with clean
water.
• Do not throw into a re.
• When discarding or recycling batteries, make sure not to short-circuit (+)(-) the
terminals.
• Please recycle. Do not dispose of old batteries with your household waste; dis
pose of them safely at your recycling centre or business where the batteries were
purchased.
Step by Step Operation Guide for Treatment
PREPARING THE SKIN FOR RUNNING A SESSION
Proper preparation of the skin covered by the electrodes allows more stimulation
to reach targeted tissues, prolongs electrode life, and reduces the risk of skin irri-
tation. After connecting the wireless units to the electrode pads, use the following
steps to prepare your skin at the electrode placement sites:
1. Determine the placement sites for the electrodes.
2. Wash the area with mild soap and water (do not use alcohol). Rinse and dry
thoroughly.
3. Trim excess body hair from the area with scissors (do not shave).
4. Optionally, apply skin prep to the area to form a protective barrier on your skin.
Apply, let dry, and apply electrode as directed. This will both reduce the chance
of skin irritation and extend the life of your electrodes.
5. When removing electrodes, always remove by pulling in the direction of hair
growth.
6. It may be helpful to apply skin lotion on electrode placement area when not
wearing electrodes.
Placement of Electrode
1. Place the electrode with the contact
plugs up onto a at surface. Place the
wireless unit with the contact jacks
down onto the Electrode pad so that
plugs and jacks are aligned. Then press
down until completely snapped in.
2. Do not remove the clear plastic shield
from Electrode until the unit is ready to
be placed on the body.

16 17
Shoulder
Calf
Muscle
Low
Back
Upper
Back
Bottom
ABS
Back of
Thighs
Front of
Thighs
Turning ON/OFF Remote
1. To turn on the Remote , press and hold the power button
for one (1) second to turn on the device. All the treatment
status displays clearly on the big LCD screen, with backlight
for 10 seconds, with each entry of button. The most recently
selected program will display on the screen.
2. To turn o the Remote, press and hold the power button for
three (3) seconds to turn o the device. Or it will be automat-
ically o when no button is pressed for 3 minutes.
Note: Do not turn the unit on until the receiver(s) are properly
attached.
Note: When stimulating the muscles of the arms or legs bear in
mind that the muscle contraction may cause involuntary limb
movement which could cause injury to you or others. Always
ensure the limb is secured to prevent movement.
Turning On/Off Receiver
1. Turn on the receiver, press the Power button.
2. Blue backlight will be lighted up, and lasting on 60
seconds, then it will light o if no other entry.
3. Blue backlight of the receiving unit is then ashing whist
the identical wireless unit receives the signal from the remote.
4. To turn o the receiver pod(s)
• When treatment minutes are remaining, reduce intensity to “0” then press
and hold the power button for 3 seconds.
• When treatment minutes have not been set, press and hold the power
button for 3 seconds.
Note: In an emergency you may take o the receiver(s) and electrodes directly
from treatment site(s).
Note: To prevent unpleasant electric shocks, never remove o the device while it
is still turned on.
LOWER BACK
Place a pair of pads
horizontally either side of
your spine on the lower part
of the back.
UPPER BACK
Place a pair of pads
horizontally either side of
your spine on the upper part
of the back.
BOTTOM
Place a pair of pads
horizontally across the
buttocks halfway between
the midline and the side of
your body.
FRONT OF THIGHS
Place each pair of pads
vertically across each
thigh muscle.
SHOULDER
Place on half of the pad on
the front of your shoulder
and the other on the side.
BACK OF THIGHS
Place each pair of pads
vertically across your
hamstrings.
CALF MUSCLES
Place each pair of pads
vertically across each
calf muscle. Do not
place them too low on
the leg, as this can result
in an uncomfortable
contraction.
ABS
Place each pair of pads
horizontally either side of
your navel.
Placement of Electrode

18 19
Communication between Remote and Receiver(s)
Radio Frequency Wireless technology 2.4G is used in this system, for good quality
of service between the remote and wireless unit(s) requirement requires 3 meters
(9 feet).
1. LCD symbol on the remote control and LED indicator guide on wireless unit(s):
1. It shows Mode, Timer, Intensity Level, and wireless unit by
Channel number on the LCD display when Power ON, LED back-
light for 10 seconds.
2. If the paired wireless is connected, it will display: or
3. If low battery symbol shows , battery power is low.
When charging the remote , the device will shut o automat-
ically.
1. When Power ON, Blue LED light on.
2. LED in Blue blinking on the Channel in use, when it receives
signal transmitting from the Remote Control.
3. LED in Red Flashing, battery power is low.
Receiver unit will turn on when charging the battery, Orange
light lasting until fully charged, then it turns o.
2. There is one (1) Remote with two (2) receivers (Ch1 or Ch2 printed on the front)
supplied for use with this system. Additional two (2) receivers (Ch3,Ch4) might be
available for replacement purpose, please contact authorized distributors.
3. Whenever the receivers turns on, the remote control unit shall display the identi-
cal number of receiver(s) . Make sure the identical receiver is turned on and prop-
erly placed before setting up Program /Timer / Intensity Level.
4. The Remote will display treatment status on the LCD sequentially in turn to the
Channel of receiver(s). Or, you could turn o the remote when all set.
Selecting the Program
The Device oers 8 dierent preset treatment programs respectively for TENS
and 6 programs for EMS modes; the programs dier with respect to varying
pulse widths and frequencies.
Choice of the appropriate mode and treatment program
The mode you choose determines the kind of work that is imposed upon the stimu-
lated muscles. Choose the mode that is appropriate to your needs or gives you the
greatest pleasure.
How to Select TENS/EMS Mode
1. Press the“SET” button , the preset (default) therapy modeTENS/EMS will ash on
the display. Use UP or the button DOWN, if you would like to change the therapy
mode.
2. Press the SET button again, the numeric number of program is then ashing.
3. Press the button UP (to increase) or the button DOWN (to decrease) for choice of
program of the selected modality.
Note: Make sure the identical receiver is turned on and properly placed.

20 21
For TENS programs:
When using any of the 8 programs for pain relief always start with the lowest
intensity and gradually increase the level of intensity until you feel a “tingling”
sensation. All programs are dierent and therefore feel dierently. You may try
all 8 programs in the beginning and choose one that feels pleasant. Never in-
crease the intensity to a level so that it hurts, always stay under the point of
discomfort. Start with short sessions of 5 or 10 minutes until your body gets
used to the stimulation.
Mode Puls width Frequency Mode type
P1
P2
P3
P4
P5
P6
P7
260
P8
260~156
260
260
260~156
260
260~156
Cycle P1~P7
15
60
60
2~60
60
60
7~60
Constant
Burst
Constant
Dense-Disperese
Modulation Pulse Width
SD Pulse Rate (MR)
SD Pulse Width (MW)
All electrical specication ±20%
For EMS programs:
When using the device for muscle stimulation (EMS) any of the 6 programs may
be used. The intent is to cause a muscle to contract, and then release. All 6 pro-
grams will achieve contraction and vary mainly by the rate and duration of the
contractions. As with any exercise regiment, start out slowly with low intensity
levels for a warm-up (5~10min). You may increase intensity level and treatment
time as you progress with your muscle performance. Use the device regularly
over a longer period of time as to maintain the benet you may have gained
during “exercise”.
Mode
P1
P2
P3
P4
P5
P6
P7
P8
All electrical specication ±20%
Ramp up Ramp down
On Time O Time Mode type
(µS)
Pulse width
(Hz)
Frequency
Synchronous
Alternation
Alternation
Alternation
Constant
260
260
260
260
260
260
260
260 7~60
60
60
70
70
50
50
50
2
2
2
2
2
2
2
3 2
2
2
2
2
2
2
- -- -
2
4
5
6
2
4
6
3
4
5
6
8
10
Synchronous
Synchronous
Synchronous

22 23
Selecting the Therapy Time
1. Press the “SET” button again, the preset (default)
treatment time will ash on the display.
2. To increase or decrease the treatment time, press
the button UP (to increase) or the button Down (to
decrease) repeatedly until the desired duration ap-
pears on the display.
3. The treatment time you selected will appear on the
display the next time you turn the device on.
Note: If you change programs during the course of
a therapy session, the treatment time will not set
unless you manually reset it by performing the steps
described above.
Selecting the Therapy Intensity Level
The Device oers 25 intensity levels!
Intensity is adjustable according to the receiver
selected. Make sure the identical wireless unit is
turned on and properly placed.
1. Press the “SET”button, the numeric number of
program is then ashing.
2. To increase or decrease the intensity, press the
button UP (to increase) or the button Down (to decrease) repeatedly until the
desired intensity level ashes on the display.
Note: You will feel the intensity increase or decrease as you select the intensity
level. You can use this as a guide to select a level that is comfortable for you.
Note: If you change therapy mode/program during the course of a therapy ses-
sion, the intensity level will reset to“0” for safety reason.
Pod Channel Pairing
You may use as many pods as you would like on a single channel. The settings and
intensity levels will be shared to all pods paired as that respective channel.
The two pods that are included are paired as CH1 but may be paired as an alternate
channel (CH2, CH3, or CH4) in the event you would like to control the pods inde-
pendently of each other.
Pod pairing sets as follows:
STEP 1: Turn on wireless remote and receiver pod(s) you
wish to pair.
Note: All pods powered on at this time will be paired.
Turn o all pod(s) you wish not to pair or you may
unintentionally pair any pod(s) within 9-10 feet.
STEP 2: Hold the UP and POWER buttons for 3 seconds to access the channel
pairing screen.
STEP 3: While in pairing screen, press the CH button to
navigate to desired channel (CH1, CH2, CH3, CH4). Once
you have selected the channel, then press SET button.
Note: When the receiver pods are paired, the button on
the pod(s) will blink twice, which means that the chan-
nel pairing was successful. The LCD on the remote will
display SS.
Note: If the receiver pod(s) did not pair successfully, the
button on the receiver pod(s) will not blink. The LCD on
the remote will display FF.
STEP 4: To exit pairing screen, press the SET button to
return to the standby screen.
Note: Your receiver pod(s) will now be programmed to the channel you selected.
Repeat the process with additional pod(s) if desired.

24 25
Rechargeable Battery
The rechargeable Battery is built-in the device(s). Please do not at-
tempt to disassemble or force open the built-in battery. To maximize
battery life, please charge the system every 3 months when not in use.
Do not dispose of the device(s) in a re. The battery could explode
causing injury or death.
Replacement Parts and Wearing Parts
www.healthy-at-home.de
Cleaning and Storage
Adhesive electrodes
• To ensure that the adhesive electrodes remain adhesive for as long as
possible, clean them carefully with a damp, lint-free cloth or clean the
underside of the electrodes under lukewarm, running water and pat dry
with a lint-free cloth. Before cleaning with water, remove the connection
cables from the electrodes.
• Reapply the electrodes to the carrier foil following treatment.
Cleaning the device
• Remove the batteries from the device before cleaning.
• Clean the device after use with a soft, slightly damp cloth. If it is very dirty,
you can also moisten the cloth with a mild soapy solution.
• Do not use any chemical or abrasive cleaning agents. Ensure that no water
enters the device.
Reuse of the device
Once it has been properly prepared, the device can be used again. Prepara-
tion includes replacement of the treatment electrodes as well as cleaning of
the surface of the device using a cloth moistened with a mild soapy solution.
Storage
• Do not make sharp bends in the connection cables and electrodes.
• Disconnect the connection cables from the electrodes.
• Reapply the electrodes to the carrier foil after use.
• Store the device and accessories in a cool, well-ventilated space.
• Never place any heavy objects on the device.

26 27
Technical Data
** All electrical specications are ±10%
at 500Ω load.
Notes on Electromagnetic Compatibility
WARNING!
The device is suitable for use in all environments listed in these instructions for use,
including domestic environments. The use of the device may be limited in the presence
of electromagnetic disturbances. This could result in issues such as error messages or
the failure of the display/device. Avoid using this device directly next to other devices
or stacked on top of other devices, as this could lead to faulty operation. If, however,
it is necessary to use the device in the manner stated, this device as well as the other
devices must be monitored to ensure they are working properly. The use of accessories
other than those specied or provided by the manufacturer of this device can lead to
an increase in electromagnetic emissions or a decrease in the device’s electromagnetic
immunity; this can result in faulty operation. Keep portable RF communication devices
(including peripheral equipment, such as antenna cables or external antennas) at least
30 cm away from all device parts, including all cables included in delivery. Failure to
comply with the above can impair the performance of the device. Failure to comply
with the above can impair the performance of the device.
Disposal
For environmental reasons, do not dispose of the device in the household
waste at the end of its useful life. Dispose of the unit at a suitable local collec-
tion or recycling point. Dispose of the device in accordance with EC Directive –
WEEE (Waste Electrical and Electronic Equipment). If you have any questions,
please contact the local authorities responsible for waste disposal.
Note
The codes below are printed on batteries containing harmful substances: Pb = Battery
contains lead, Cd = Battery contains cadmium, Hg = Battery contains mercury.
Channel: Dual , 2 wireless units independent and individually adjust-
able channels, electrically insulated from one another
Pulse Rate: As pre-programmed, in operation mode
Pulse Width: As pre-programmed, in operation mode
Timer: 5~60 min. selectable
Wave Form: Symmetrical Bi-Phasic square pulse
Max Charge per Pulse: 20.8 micro-coulombs maximum
Input rating: 5Vdc, 1A
Power Source: Remote Control Battery 3.7V /260 mAh Lithium polymer
(LiPo) battery. Wireless unit 3.7V /180 mAh Lithium polymer
(LiPo) battery.
AC Adaptor manufac-
turer/model:
FranMar International Inc. / FRM06-S05-z, 28.1x64.1x42
mm( LxWxH)
AC Adaptor I/P: 100-240Vac, 50/60Hz, 0.45A; Output: 5Vdc, 1A
Weight & Dimension: Remote Control 60 grams (battery included),
156.98x47x15.50 mm
Wireless Unit: 30 grams (battery included), 60x60x15.65 mm
Operating Conditions: + 50°F (10°C) to +104° (40°C), 40-90% max. Relative
humidity
Transport and Storage
Conditions:
+14°F (-10°C) to +140° (60°C), 30-95% max. Relative
humidity
Operation altitude: 3000m
Operating Atmospheric
pressure range:
700~1013 hPa
Transport and Storage
Atmospheric pressure
range:
500~1060 hPa
Radiations Frequency: 2.4GHz
Frequency Band: 2400~2483.5MHz
GFSK typical: GFSK

28 29
EUROMEDICS GmbH, Hauptstraße
169 D-59846 Sundern, Germany
(hereinafter called “EUROMEDICS”)
provides a warranty for the prorelax®
TENS+EMS DUO COMFORT WIRELESS
(hereinafter called the “Product”)
subject to the following preconditi-
ons and in the scope described be-
low.
The warranty conditions described
below do not aect the legally pre-
scribed warranty obligations of the
seller from the contract of purchase
with the buyer. Moreover, the war-
ranty applies irrespective of manda-
tory legal liability provisions, such
as those according to the product
liability law, or in cases of mala de
intent or gross negligence, or owing
to injury to life and limb, or to health
by EUROMEDICS or its agents.
EUROMEDICS guarantees the de-
fect-free operability and the com-
pleteness of the product, especially
that the product is free of material
defects, manufacturing defects and
construction defects. The decisive
factor in this regard is the state of the
art of the science and technology at
the time of manufacturing. The pro-
If the purchaser wishes to file a war-
ranty claim, he must first contact
EUROMEDICS customer service:
EUROMEDICS Customer Service
Grandkaule 3
Tel: +49 (0)2208/9217999
D-53859 Niederkassel
E-Mail: [email protected]
The purchaser will then get further
information on how to process the
guarantee case, for example, where
he can send the device free of cost
and what documentation is required.
Filing a warranty claim can only come
into
consideration if the buyer can submit
- a copy of the invoice/proof of
purchase and
- the original product
to EUROMEDICS or to a service cen-
tre nominated by EUROMEDICS upon
demand.
duct must have manifested the de-
fect that caused the damage at that
time itself.
The warranty period is 2 years from
the date of purchase of a new, un-
used product by the purchaser.
The warranty applies worldwide, i.e.
regardless of the country in which
EUROMEDICS has marketed the pro-
duct and the purchaser has purcha-
sed it.
This warranty only applies to pro-
ducts that the purchaser has procu-
red as a consumer and exclusively for
personal purposes in the framework
of domestic use (i.e. not for products
that were procured or used in the
framework of a commercial or inde-
pendent professional activity).
If the product is found to be decient
in operability in accordance with the
following provisions during the war-
ranty period, EUROMEDICS will pro-
vide a free replacement according to
these warranty conditions.
Expressly excepted from this warran-
ty are
- products that are used, cleaned,
stored or maintai- ned incorrect-
ly and/or not in compliance with
the conditions laid down in the
operating manual, as well as pro-
ducts that were opened, repaired
or modied by the purchaser or by
a service centre not authorised by
EUROMEDICS;
- products that were sold as second
quality or used articles;
- consequential damages arising
from a defect in the product (ho-
wever, in this case, there may be
entitlements from product liability
or from other mandatory legal lia-
bility regulations).
Warranty

30
MDSS GmbH
Schiffgraben 41, D-30175
Hannover, Germany
Well-Life Healthcare Ltd.
6F., No. 168, Lide St., Jhonghe District,
New Taipei City, 23512, Taiwan
EXCLUSIVELY IMPORTED AND
DISTRIBUTED IN EUROPE BY: EUROMEDICS GmbH
Hauptstraße 169 D-59846 Sundern Germany
[email protected] www.euromedics.de
prorelax.com
1639
Other manuals for DuoComfort Wireless
1
Table of contents
Other Prorelax Personal Care Product manuals
Popular Personal Care Product manuals by other brands

Lola&Lykke
Lola&Lykke Core Restore Postpartum Support Belt Instructions for use

Madeli
Madeli Slique TRANQUILITY IM-TR2036-00 Specifications, Installation and User’s Guide

Harvest Healthcare
Harvest Healthcare HANDLING GLOVE General User/ Safety Guide

Tescom
Tescom Nobby NTE10 manual

Orliman
Orliman oneplus OPL161 Use and maintenance instructions

mychway
mychway MS-54D4S user manual