Provision ISR Ultra-AHD Series User manual

1080P 4 in 1 Ultra-AHD Series
USER MANUAL
1 CAUTIONS
1. To reduce the risk of electric shock, do not open the
machine and maintain by yourself, please consult a
professional service person.
2. To prevent fire or shock hazard, use the power after
safety certification, the input voltage, current, voltage
polarity and operating temperature must meet the
requirements of this camera.
3. Please note the operating temperature and environ-
mental requirements of the camera, avoid too low or
too high temperature. General operating temperature
range of -10°C ~ +50°C (Fahrenheit temperature is
14°F ~ 122°F). Avoid flooding and rain, minimize dust
and moisture erosion, otherwise camera would be
damaged.
4. Cameras in use should avoid direct sunlight, glare,
otherwise the sensor will be damaged.
5. Do not touch the sensor surface, if any foreign
objects exits, a cotton swab or lens paper can be used
to wipe, if it is difficult to remove, a neutral detergent
diluted with water would be useful. Do not use
corrosive solution.
6. In order to make the camera work smoothly and
obtain asatisfactory image, the power cord and video
connection can not be too long, otherwise the increase
of line loss will lead to the inadequate magnitude of the
operating voltage of the camera or video signal
Inadequate.
7. In order to prevent the camera from falling, please
do not place the camera on an unstable bracket, base
or other unstable objects. Otherwise it will lead to
injury, at the same time, the camera will be damaged.
8. The camera cannot be placed near the radiator or
heating resistor.
2 Product Introduction
2.1 Camera Introduction
PROVISION-ISR’s new series of cameras have
adopted a high performance CMOS image sensor
which provides HD resolution and supports high
resolution video output. The cameras support video
transmission distance of around 400M base on Rg59
standard coaxial cable. This series can support
AHD/TVI/CVI/CVBS 960H analog output.
2.2 Product Features
● Dual Coaxial cable with BNC connenctors
● AHD/TVI/CVI/CVBS Output
● True WDR@30fps(Not Available for Analog Output)
● Motorized 2.8-12mm Vari-Focal Auto Focus Lens
● Auto Day/Night (ICR)
● Defog, HBLC, BLC
● 2D/3D Noise Reduction
● Motion Detection, Privacy Mask
3 OSD Controller
3.1 OSD Control:
Center: Enter OSD/ Enter
Up: Navigate OSD up
Down: Navigate OSD Down
Left: adjust OSD Menu values
Right: adjust OSD Menu values
3.2 Lens Cotrol:
Zoom-In: Press UP continuously
Zoom-Out: Press Down continuously
Focus-: Press Left continuously
Focus+: Press Right continuously
3.3 Output adjustment:
AHD: press center for 3 Second and then Right
TVI: press center for 3 Second and then Left
CVI: press center for 3 Second and then Up
4 Control Over Coaxial(CoC)
4.1 AHD/TVI:
Click on “Iris+” button from the DVR’s PTZ interface to
call the OSD Menu. Use the PTZ interface to scroll
through the menu and “Iris+” to confirm.
4.2 CVI:
Click “
►” button from the DVR’s PTZ interface, then
click “ ” and press “Enter” to call the OSD Menu.
5 Product Installation
5.1 General Notes
1. Make sure the unit is powered off before installation.
2. Check power supply voltage consistent with the
electric voltage to prevent voltage unworthy, resulting
in damage to the device.
3. Do not use in the environment beyond the boundar-
ies of the temperature, and maintain good ventilation
to prevent the rain in order to reduce the risk of fire or
electric shock.
4. The installation and maintenance of this product
should be professional, please do not in any way to
remove or modify the equipment; can only use the
required accessories of manufacturers. Problems
caused by unauthorized repair are at your own risk.
5.2 Installation Tools and Information
Prepare the required engineering data and instruc-
tions. Before installation please prepare the following
tools and instrumentation: A straight or a
Phillips-head screwdriver, multi-meter, scissors,
needle nose pliers, tape measure, pencil and so on.
5.3 Installation Method
1. Check the equipment whether it is damaged.
2. Mounting bracket or base.
① If the cement wall, install the expansion screws
(expansion screw holes need stand or base hole), and
then mount bracket or base.
② If the wooden wall, use self-tapping screws to
mount.
3. Mounting the camera
a. Dome Camera
Adjust the lens position and make it aim at the
monitoring points and present a clear picture, manual-
ly fix lens location and adjust the hemisphere cover.
Re-examine the screen whether the character meets
the requirement. Tighten the hemisphere cover.
b. Bullet Camera
Adjust the body so that the lens aims at the monitoring
points and presents a clear picture. Tighten the
screws, to ensure that it does not move.
Note:
The wall needs to bear at least
3X weight of bracket (base) and
camera.
5.4 Connections
Connection as shown in the figure below:
5.5 Lens Control
Use the DVR PTZ interface Zoom+/- to control the
motorized lens.
5.6 OSD Control
The preffered control method is CoC (Control over
Coax). If your AHD DVR supports this function*, Use
the DVR’s PTZ interface to call Preset 95 or press on
“Iris+” to open the OSD menu. Navigate through the
OSD menu by the PTZ direction arrows. “Iris+”
performs as “Enter”.
*All of Provision-ISR’s DVRs support CoC Starting from version 3.4.4

1
Contents 1 CAUTIONS
1. To reduce the risk of electric shock, do not open the
machine and maintain by yourself, please consult a
professional service person.
2. To prevent fire or shock hazard, use the power after
safety certification, the input voltage, current, voltage
polarity and operating temperature must meet the
requirements of this camera.
3. Please note the operating temperature and environ-
mental requirements of the camera, avoid too low or
too high temperature. General operating temperature
range of -10°C ~ +50°C (Fahrenheit temperature is
14°F ~ 122°F). Avoid flooding and rain, minimize dust
and moisture erosion, otherwise camera would be
damaged.
4. Cameras in use should avoid direct sunlight, glare,
otherwise the sensor will be damaged.
5. Do not touch the sensor surface, if any foreign
objects exits, a cotton swab or lens paper can be used
to wipe, if it is difficult to remove, a neutral detergent
diluted with water would be useful. Do not use
corrosive solution.
6. In order to make the camera work smoothly and
obtain asatisfactory image, the power cord and video
connection can not be too long, otherwise the increase
of line loss will lead to the inadequate magnitude of the
operating voltage of the camera or video signal
Inadequate.
7. In order to prevent the camera from falling, please
do not place the camera on an unstable bracket, base
or other unstable objects. Otherwise it will lead to
injury, at the same time, the camera will be damaged.
8. The camera cannot be placed near the radiator or
heating resistor.
2 Product Introduction
2.1 Camera Introduction
PROVISION-ISR’s new series of cameras have
adopted a high performance CMOS image sensor
which provides HD resolution and supports high
resolution video output. The cameras support video
transmission distance of around 400M base on Rg59
standard coaxial cable. This series can support
AHD/TVI/CVI/CVBS 960H analog output.
2.2 Product Features
● Dual Coaxial cable with BNC connenctors
● AHD/TVI/CVI/CVBS Output
● True WDR@30fps(Not Available for Analog Output)
● Motorized 2.8-12mm Vari-Focal Auto Focus Lens
● Auto Day/Night (ICR)
● Defog, HBLC, BLC
● 2D/3D Noise Reduction
● Motion Detection, Privacy Mask
3 OSD Controller
3.1 OSD Control:
Center: Enter OSD/ Enter
Up: Navigate OSD up
Down: Navigate OSD Down
Left: adjust OSD Menu values
Right: adjust OSD Menu values
3.2 Lens Cotrol:
Zoom-In: Press UP continuously
Zoom-Out: Press Down continuously
Focus-: Press Left continuously
Focus+: Press Right continuously
3.3 Output adjustment:
AHD: press center for 3 Second and then Right
TVI: press center for 3 Second and then Left
CVI: press center for 3 Second and then Up
4 Control Over Coaxial(CoC)
4.1 AHD/TVI:
Click on “Iris+” button from the DVR’s PTZ interface to
call the OSD Menu. Use the PTZ interface to scroll
through the menu and “Iris+” to confirm.
4.2 CVI:
Click “
►” button from the DVR’s PTZ interface, then
click “ ” and press “Enter” to call the OSD Menu.
5 Product Installation
5.1 General Notes
1. Make sure the unit is powered off before installation.
2. Check power supply voltage consistent with the
electric voltage to prevent voltage unworthy, resulting
in damage to the device.
3. Do not use in the environment beyond the boundar-
ies of the temperature, and maintain good ventilation
to prevent the rain in order to reduce the risk of fire or
electric shock.
4. The installation and maintenance of this product
should be professional, please do not in any way to
remove or modify the equipment; can only use the
required accessories of manufacturers. Problems
caused by unauthorized repair are at your own risk.
5.2 Installation Tools and Information
Prepare the required engineering data and instruc-
tions. Before installation please prepare the following
tools and instrumentation: A straight or a
Phillips-head screwdriver, multi-meter, scissors,
needle nose pliers, tape measure, pencil and so on.
5.3 Installation Method
1. Check the equipment whether it is damaged.
2. Mounting bracket or base.
① If the cement wall, install the expansion screws
(expansion screw holes need stand or base hole), and
then mount bracket or base.
② If the wooden wall, use self-tapping screws to
mount.
3. Mounting the camera
a. Dome Camera
Adjust the lens position and make it aim at the
monitoring points and present a clear picture, manual-
ly fix lens location and adjust the hemisphere cover.
Re-examine the screen whether the character meets
the requirement. Tighten the hemisphere cover.
b. Bullet Camera
Adjust the body so that the lens aims at the monitoring
points and presents a clear picture. Tighten the
screws, to ensure that it does not move.
Note:
The wall needs to bear at least
3X weight of bracket (base) and
camera.
5.4 Connections
Connection as shown in the figure below:
5.5 Lens Control
Use the DVR PTZ interface Zoom+/- to control the
motorized lens.
5.6 OSD Control
The preffered control method is CoC (Control over
Coax). If your AHD DVR supports this function*, Use
the DVR’s PTZ interface to call Preset 95 or press on
“Iris+” to open the OSD menu. Navigate through the
OSD menu by the PTZ direction arrows. “Iris+”
performs as “Enter”.
*All of Provision-ISR’s DVRs support CoC Starting from version 3.4.4
CAUTIONS
Production Introduction
2.1 Camera Introduction
2.2 Product Features
OSD Controller
3.1 OSD Control
3.2 Lens Control
3.3 Output adjustment
Control Over Coaxial(CoC)
4.1 AHD/TVI
4.2 CVI
Product Installation
5.1 General Notes
5.2 Installation Tools and Information
5.3 Installation Method
5.4 Connections
5.5 Lens Control
5.6 OSD Control
5.7 OSD Layout Scheme
Comments & Special Features
Specifications
1) 2
2)
3)
4)
5)
6)
7)
3
4
5
5
11
12

2 3
1 CAUTIONS
1. To reduce the risk of electric shock, do not open the
machine and maintain by yourself, please consult a
professional service person.
2. To prevent fire or shock hazard, use the power after
safety certification, the input voltage, current, voltage
polarity and operating temperature must meet the
requirements of this camera.
3. Please note the operating temperature and environ-
mental requirements of the camera, avoid too low or
too high temperature. General operating temperature
range of -10°C ~ +50°C (Fahrenheit temperature is
14°F ~ 122°F). Avoid flooding and rain, minimize dust
and moisture erosion, otherwise camera would be
damaged.
4. Cameras in use should avoid direct sunlight, glare,
otherwise the sensor will be damaged.
5. Do not touch the sensor surface, if any foreign
objects exits, a cotton swab or lens paper can be used
to wipe, if it is difficult to remove, a neutral detergent
diluted with water would be useful. Do not use
corrosive solution.
6. In order to make the camera work smoothly and
obtain asatisfactory image, the power cord and video
connection can not be too long, otherwise the increase
of line loss will lead to the inadequate magnitude of the
operating voltage of the camera or video signal
Inadequate.
7. In order to prevent the camera from falling, please
do not place the camera on an unstable bracket, base
or other unstable objects. Otherwise it will lead to
injury, at the same time, the camera will be damaged.
8. The camera cannot be placed near the radiator or
heating resistor.
2 Product Introduction
2.1 Camera Introduction
PROVISION-ISR’s new series of cameras have
adopted a high performance CMOS image sensor
which provides HD resolution and supports high
resolution video output. The cameras support video
transmission distance of around 400M base on Rg59
standard coaxial cable. This series can support
AHD/TVI/CVI/CVBS 960H analog output.
2.2 Product Features
● Dual Coaxial cable with BNC connenctors
● AHD/TVI/CVI/CVBS Output
● True WDR@30fps(Not Available for Analog Output)
● Motorized 2.8-12mm Vari-Focal Auto Focus Lens
● Auto Day/Night (ICR)
● Defog, HBLC, BLC
● 2D/3D Noise Reduction
● Motion Detection, Privacy Mask
3 OSD Controller
3.1 OSD Control:
Center: Enter OSD/ Enter
Up: Navigate OSD up
Down: Navigate OSD Down
Left: adjust OSD Menu values
Right: adjust OSD Menu values
3.2 Lens Cotrol:
Zoom-In: Press UP continuously
Zoom-Out: Press Down continuously
Focus-: Press Left continuously
Focus+: Press Right continuously
3.3 Output adjustment:
AHD: press center for 3 Second and then Right
TVI: press center for 3 Second and then Left
CVI: press center for 3 Second and then Up
4 Control Over Coaxial(CoC)
4.1 AHD/TVI:
Click on “Iris+” button from the DVR’s PTZ interface to
call the OSD Menu. Use the PTZ interface to scroll
through the menu and “Iris+” to confirm.
4.2 CVI:
Click “
►” button from the DVR’s PTZ interface, then
click “ ” and press “Enter” to call the OSD Menu.
5 Product Installation
5.1 General Notes
1. Make sure the unit is powered off before installation.
2. Check power supply voltage consistent with the
electric voltage to prevent voltage unworthy, resulting
in damage to the device.
3. Do not use in the environment beyond the boundar-
ies of the temperature, and maintain good ventilation
to prevent the rain in order to reduce the risk of fire or
electric shock.
4. The installation and maintenance of this product
should be professional, please do not in any way to
remove or modify the equipment; can only use the
required accessories of manufacturers. Problems
caused by unauthorized repair are at your own risk.
5.2 Installation Tools and Information
Prepare the required engineering data and instruc-
tions. Before installation please prepare the following
tools and instrumentation: A straight or a
Phillips-head screwdriver, multi-meter, scissors,
needle nose pliers, tape measure, pencil and so on.
5.3 Installation Method
1. Check the equipment whether it is damaged.
2. Mounting bracket or base.
① If the cement wall, install the expansion screws
(expansion screw holes need stand or base hole), and
then mount bracket or base.
② If the wooden wall, use self-tapping screws to
mount.
3. Mounting the camera
a. Dome Camera
Adjust the lens position and make it aim at the
monitoring points and present a clear picture, manual-
ly fix lens location and adjust the hemisphere cover.
Re-examine the screen whether the character meets
the requirement. Tighten the hemisphere cover.
b. Bullet Camera
Adjust the body so that the lens aims at the monitoring
points and presents a clear picture. Tighten the
screws, to ensure that it does not move.
Note:
The wall needs to bear at least
3X weight of bracket (base) and
camera.
5.4 Connections
Connection as shown in the figure below:
5.5 Lens Control
Use the DVR PTZ interface Zoom+/- to control the
motorized lens.
5.6 OSD Control
The preffered control method is CoC (Control over
Coax). If your AHD DVR supports this function*, Use
the DVR’s PTZ interface to call Preset 95 or press on
“Iris+” to open the OSD menu. Navigate through the
OSD menu by the PTZ direction arrows. “Iris+”
performs as “Enter”.
*All of Provision-ISR’s DVRs support CoC Starting from version 3.4.4

4 5
1 CAUTIONS
1. To reduce the risk of electric shock, do not open the
machine and maintain by yourself, please consult a
professional service person.
2. To prevent fire or shock hazard, use the power after
safety certification, the input voltage, current, voltage
polarity and operating temperature must meet the
requirements of this camera.
3. Please note the operating temperature and environ-
mental requirements of the camera, avoid too low or
too high temperature. General operating temperature
range of -10°C ~ +50°C (Fahrenheit temperature is
14°F ~ 122°F). Avoid flooding and rain, minimize dust
and moisture erosion, otherwise camera would be
damaged.
4. Cameras in use should avoid direct sunlight, glare,
otherwise the sensor will be damaged.
5. Do not touch the sensor surface, if any foreign
objects exits, a cotton swab or lens paper can be used
to wipe, if it is difficult to remove, a neutral detergent
diluted with water would be useful. Do not use
corrosive solution.
6. In order to make the camera work smoothly and
obtain asatisfactory image, the power cord and video
connection can not be too long, otherwise the increase
of line loss will lead to the inadequate magnitude of the
operating voltage of the camera or video signal
Inadequate.
7. In order to prevent the camera from falling, please
do not place the camera on an unstable bracket, base
or other unstable objects. Otherwise it will lead to
injury, at the same time, the camera will be damaged.
8. The camera cannot be placed near the radiator or
heating resistor.
2 Product Introduction
2.1 Camera Introduction
PROVISION-ISR’s new series of cameras have
adopted a high performance CMOS image sensor
which provides HD resolution and supports high
resolution video output. The cameras support video
transmission distance of around 400M base on Rg59
standard coaxial cable. This series can support
AHD/TVI/CVI/CVBS 960H analog output.
2.2 Product Features
● Dual Coaxial cable with BNC connenctors
● AHD/TVI/CVI/CVBS Output
● True WDR@30fps(Not Available for Analog Output)
● Motorized 2.8-12mm Vari-Focal Auto Focus Lens
● Auto Day/Night (ICR)
● Defog, HBLC, BLC
● 2D/3D Noise Reduction
● Motion Detection, Privacy Mask
3 OSD Controller
3.1 OSD Control:
Center: Enter OSD/ Enter
Up: Navigate OSD up
Down: Navigate OSD Down
Left: adjust OSD Menu values
Right: adjust OSD Menu values
3.2 Lens Cotrol:
Zoom-In: Press UP continuously
Zoom-Out: Press Down continuously
Focus-: Press Left continuously
Focus+: Press Right continuously
3.3 Output adjustment:
AHD: press center for 3 Second and then Right
TVI: press center for 3 Second and then Left
CVI: press center for 3 Second and then Up
4 Control Over Coaxial(CoC)
4.1 AHD/TVI:
Click on “Iris+” button from the DVR’s PTZ interface to
call the OSD Menu. Use the PTZ interface to scroll
through the menu and “Iris+” to confirm.
4.2 CVI:
Click “
►” button from the DVR’s PTZ interface, then
click “ ” and press “Enter” to call the OSD Menu.
5 Product Installation
5.1 General Notes
1. Make sure the unit is powered off before installation.
2. Check power supply voltage consistent with the
electric voltage to prevent voltage unworthy, resulting
in damage to the device.
3. Do not use in the environment beyond the boundar-
ies of the temperature, and maintain good ventilation
to prevent the rain in order to reduce the risk of fire or
electric shock.
4. The installation and maintenance of this product
should be professional, please do not in any way to
remove or modify the equipment; can only use the
required accessories of manufacturers. Problems
caused by unauthorized repair are at your own risk.
5.2 Installation Tools and Information
Prepare the required engineering data and instruc-
tions. Before installation please prepare the following
tools and instrumentation: A straight or a
Phillips-head screwdriver, multi-meter, scissors,
needle nose pliers, tape measure, pencil and so on.
5.3 Installation Method
1. Check the equipment whether it is damaged.
2. Mounting bracket or base.
① If the cement wall, install the expansion screws
(expansion screw holes need stand or base hole), and
then mount bracket or base.
② If the wooden wall, use self-tapping screws to
mount.
3. Mounting the camera
a. Dome Camera
Adjust the lens position and make it aim at the
monitoring points and present a clear picture, manual-
ly fix lens location and adjust the hemisphere cover.
Re-examine the screen whether the character meets
the requirement. Tighten the hemisphere cover.
b. Bullet Camera
Adjust the body so that the lens aims at the monitoring
points and presents a clear picture. Tighten the
screws, to ensure that it does not move.
Note:
The wall needs to bear at least
3X weight of bracket (base) and
camera.
5.4 Connections
Connection as shown in the figure below:
5.5 Lens Control
Use the DVR PTZ interface Zoom+/- to control the
motorized lens.
5.6 OSD Control
The preffered control method is CoC (Control over
Coax). If your AHD DVR supports this function*, Use
the DVR’s PTZ interface to call Preset 95 or press on
“Iris+” to open the OSD menu. Navigate through the
OSD menu by the PTZ direction arrows. “Iris+”
performs as “Enter”.
*All of Provision-ISR’s DVRs support CoC Starting from version 3.4.4

6 7
1 CAUTIONS
1. To reduce the risk of electric shock, do not open the
machine and maintain by yourself, please consult a
professional service person.
2. To prevent fire or shock hazard, use the power after
safety certification, the input voltage, current, voltage
polarity and operating temperature must meet the
requirements of this camera.
3. Please note the operating temperature and environ-
mental requirements of the camera, avoid too low or
too high temperature. General operating temperature
range of -10°C ~ +50°C (Fahrenheit temperature is
14°F ~ 122°F). Avoid flooding and rain, minimize dust
and moisture erosion, otherwise camera would be
damaged.
4. Cameras in use should avoid direct sunlight, glare,
otherwise the sensor will be damaged.
5. Do not touch the sensor surface, if any foreign
objects exits, a cotton swab or lens paper can be used
to wipe, if it is difficult to remove, a neutral detergent
diluted with water would be useful. Do not use
corrosive solution.
6. In order to make the camera work smoothly and
obtain asatisfactory image, the power cord and video
connection can not be too long, otherwise the increase
of line loss will lead to the inadequate magnitude of the
operating voltage of the camera or video signal
Inadequate.
7. In order to prevent the camera from falling, please
do not place the camera on an unstable bracket, base
or other unstable objects. Otherwise it will lead to
injury, at the same time, the camera will be damaged.
8. The camera cannot be placed near the radiator or
heating resistor.
2 Product Introduction
2.1 Camera Introduction
PROVISION-ISR’s new series of cameras have
adopted a high performance CMOS image sensor
which provides HD resolution and supports high
resolution video output. The cameras support video
transmission distance of around 400M base on Rg59
standard coaxial cable. This series can support
AHD/TVI/CVI/CVBS 960H analog output.
2.2 Product Features
● Dual Coaxial cable with BNC connenctors
● AHD/TVI/CVI/CVBS Output
● True WDR@30fps(Not Available for Analog Output)
● Motorized 2.8-12mm Vari-Focal Auto Focus Lens
● Auto Day/Night (ICR)
● Defog, HBLC, BLC
● 2D/3D Noise Reduction
● Motion Detection, Privacy Mask
3 OSD Controller
3.1 OSD Control:
Center: Enter OSD/ Enter
Up: Navigate OSD up
Down: Navigate OSD Down
Left: adjust OSD Menu values
Right: adjust OSD Menu values
3.2 Lens Cotrol:
Zoom-In: Press UP continuously
Zoom-Out: Press Down continuously
Focus-: Press Left continuously
Focus+: Press Right continuously
3.3 Output adjustment:
AHD: press center for 3 Second and then Right
TVI: press center for 3 Second and then Left
CVI: press center for 3 Second and then Up
4 Control Over Coaxial(CoC)
4.1 AHD/TVI:
Click on “Iris+” button from the DVR’s PTZ interface to
call the OSD Menu. Use the PTZ interface to scroll
through the menu and “Iris+” to confirm.
4.2 CVI:
Click “
►” button from the DVR’s PTZ interface, then
click “ ” and press “Enter” to call the OSD Menu.
5 Product Installation
5.1 General Notes
1. Make sure the unit is powered off before installation.
2. Check power supply voltage consistent with the
electric voltage to prevent voltage unworthy, resulting
in damage to the device.
3. Do not use in the environment beyond the boundar-
ies of the temperature, and maintain good ventilation
to prevent the rain in order to reduce the risk of fire or
electric shock.
4. The installation and maintenance of this product
should be professional, please do not in any way to
remove or modify the equipment; can only use the
required accessories of manufacturers. Problems
caused by unauthorized repair are at your own risk.
5.2 Installation Tools and Information
Prepare the required engineering data and instruc-
tions. Before installation please prepare the following
tools and instrumentation: A straight or a
Phillips-head screwdriver, multi-meter, scissors,
needle nose pliers, tape measure, pencil and so on.
5.3 Installation Method
1. Check the equipment whether it is damaged.
2. Mounting bracket or base.
① If the cement wall, install the expansion screws
(expansion screw holes need stand or base hole), and
then mount bracket or base.
② If the wooden wall, use self-tapping screws to
mount.
3. Mounting the camera
a. Dome Camera
Adjust the lens position and make it aim at the
monitoring points and present a clear picture, manual-
ly fix lens location and adjust the hemisphere cover.
Re-examine the screen whether the character meets
the requirement. Tighten the hemisphere cover.
b. Bullet Camera
Adjust the body so that the lens aims at the monitoring
points and presents a clear picture. Tighten the
screws, to ensure that it does not move.
Note:
The wall needs to bear at least
3X weight of bracket (base) and
camera.
5.4 Connections
Connection as shown in the figure below:
5.5 Lens Control
Use the DVR PTZ interface Zoom+/- to control the
motorized lens.
5.6 OSD Control
The preffered control method is CoC (Control over
Coax). If your AHD DVR supports this function*, Use
the DVR’s PTZ interface to call Preset 95 or press on
“Iris+” to open the OSD menu. Navigate through the
OSD menu by the PTZ direction arrows. “Iris+”
performs as “Enter”.
*All of Provision-ISR’s DVRs support CoC Starting from version 3.4.4

8 9
1 CAUTIONS
1. To reduce the risk of electric shock, do not open the
machine and maintain by yourself, please consult a
professional service person.
2. To prevent fire or shock hazard, use the power after
safety certification, the input voltage, current, voltage
polarity and operating temperature must meet the
requirements of this camera.
3. Please note the operating temperature and environ-
mental requirements of the camera, avoid too low or
too high temperature. General operating temperature
range of -10°C ~ +50°C (Fahrenheit temperature is
14°F ~ 122°F). Avoid flooding and rain, minimize dust
and moisture erosion, otherwise camera would be
damaged.
4. Cameras in use should avoid direct sunlight, glare,
otherwise the sensor will be damaged.
5. Do not touch the sensor surface, if any foreign
objects exits, a cotton swab or lens paper can be used
to wipe, if it is difficult to remove, a neutral detergent
diluted with water would be useful. Do not use
corrosive solution.
VGA
Analog Signal
AHD Signal
5.7 OSD Layout Scheme
MODE
LEVEL
IMAGE DEFOG
OFF
ON AUTO、MANUAL
LOW、MIDDLE、HIGH
ELC
ALC
BRIGHTNESS
SHUTTER
SENS-UP
AGC
KELVIN
R-GAIN
B-GAIN
MODE
LEVEL
H-POS
V-POS
H-SIZE
V-SIZE
WDR WEIGHT
DNR
MODE
DELAY
D->N LEVEL
N->D LEVEL
IR LED
SMART-IR LVL
POLARITY
SHARPNESS
COLOR GAIN
FREEZ E
FLIP
ACE
GAMMA
0~20
0~20
0
~20
0
~20
OFF
0~20
OFF、H-INV、V-INV、HV-INV
OFF、ON
0~20
0~10
HIGH、LOW
0~20
AUTO、MANUAL、FLICKER
OFF、X2、X4、X 8、X16、X32
0~20
AUTO
AUTOext
IMAGE
0~20
0~20
0~20
AUTO、COLOR、B&W、EXTERN
0~20
A
LL DAY、
NIGHT ONLY
Main M enu Secondary menu
NORMAL 、DEBLUR
INDOOR、OUTDOOR、DEBLUR
0~20
OFF、LOW、MIDDLE、HIGH
0.45
、
0.5
、
0.55
、
0.6
、
0.65
、
0.7
、
0.75
OFF、ON
LENS
EXPOSURE
WHITE BAL MANUAL
PRESET
C-TEMP 3000K/5000K/8000K
BACKLIGHT
HLC
BLC
OFF、LOW、MIDDLE、HIGH
NORMAL/ROI
0
~20
DAY&NIGH
T
6. In order to make the camera work smoothly and
obtain asatisfactory image, the power cord and video
connection can not be too long, otherwise the increase
of line loss will lead to the inadequate magnitude of the
operating voltage of the camera or video signal
Inadequate.
7. In order to prevent the camera from falling, please
do not place the camera on an unstable bracket, base
or other unstable objects. Otherwise it will lead to
injury, at the same time, the camera will be damaged.
8. The camera cannot be placed near the radiator or
heating resistor.
2 Product Introduction
2.1 Camera Introduction
PROVISION-ISR’s new series of cameras have
adopted a high performance CMOS image sensor
which provides HD resolution and supports high
resolution video output. The cameras support video
transmission distance of around 400M base on Rg59
standard coaxial cable. This series can support
AHD/TVI/CVI/CVBS 960H analog output.
2.2 Product Features
● Dual Coaxial cable with BNC connenctors
● AHD/TVI/CVI/CVBS Output
● True WDR@30fps(Not Available for Analog Output)
● Motorized 2.8-12mm Vari-Focal Auto Focus Lens
● Auto Day/Night (ICR)
● Defog, HBLC, BLC
● 2D/3D Noise Reduction
● Motion Detection, Privacy Mask
3 OSD Controller
3.1 OSD Control:
Center: Enter OSD/ Enter
Up: Navigate OSD up
Down: Navigate OSD Down
Left: adjust OSD Menu values
Right: adjust OSD Menu values
3.2 Lens Cotrol:
Zoom-In: Press UP continuously
Zoom-Out: Press Down continuously
Focus-: Press Left continuously
Focus+: Press Right continuously
3.3 Output adjustment:
AHD: press center for 3 Second and then Right
TVI: press center for 3 Second and then Left
CVI: press center for 3 Second and then Up
4 Control Over Coaxial(CoC)
4.1 AHD/TVI:
Click on “Iris+” button from the DVR’s PTZ interface to
call the OSD Menu. Use the PTZ interface to scroll
through the menu and “Iris+” to confirm.
4.2 CVI:
Click “
►” button from the DVR’s PTZ interface, then
click “ ” and press “Enter” to call the OSD Menu.
5 Product Installation
5.1 General Notes
1. Make sure the unit is powered off before installation.
2. Check power supply voltage consistent with the
electric voltage to prevent voltage unworthy, resulting
in damage to the device.
3. Do not use in the environment beyond the boundar-
ies of the temperature, and maintain good ventilation
to prevent the rain in order to reduce the risk of fire or
electric shock.
4. The installation and maintenance of this product
should be professional, please do not in any way to
remove or modify the equipment; can only use the
required accessories of manufacturers. Problems
caused by unauthorized repair are at your own risk.
5.2 Installation Tools and Information
Prepare the required engineering data and instruc-
tions. Before installation please prepare the following
tools and instrumentation: A straight or a
Phillips-head screwdriver, multi-meter, scissors,
needle nose pliers, tape measure, pencil and so on.
5.3 Installation Method
1. Check the equipment whether it is damaged.
2. Mounting bracket or base.
① If the cement wall, install the expansion screws
(expansion screw holes need stand or base hole), and
then mount bracket or base.
② If the wooden wall, use self-tapping screws to
mount.
3. Mounting the camera
a. Dome Camera
Adjust the lens position and make it aim at the
monitoring points and present a clear picture, manual-
ly fix lens location and adjust the hemisphere cover.
Re-examine the screen whether the character meets
the requirement. Tighten the hemisphere cover.
b. Bullet Camera
Adjust the body so that the lens aims at the monitoring
points and presents a clear picture. Tighten the
screws, to ensure that it does not move.
Note:
The wall needs to bear at least
3X weight of bracket (base) and
camera.
5.4 Connections
Connection as shown in the figure below:
5.5 Lens Control
Use the DVR PTZ interface Zoom+/- to control the
motorized lens.
5.6 OSD Control
The preffered control method is CoC (Control over
Coax). If your AHD DVR supports this function*, Use
the DVR’s PTZ interface to call Preset 95 or press on
“Iris+” to open the OSD menu. Navigate through the
OSD menu by the PTZ direction arrows. “Iris+”
performs as “Enter”.
*All of Provision-ISR’s DVRs support CoC Starting from version 3.4.4

10 11
1 CAUTIONS
1. To reduce the risk of electric shock, do not open the
machine and maintain by yourself, please consult a
professional service person.
2. To prevent fire or shock hazard, use the power after
safety certification, the input voltage, current, voltage
polarity and operating temperature must meet the
requirements of this camera.
3. Please note the operating temperature and environ-
mental requirements of the camera, avoid too low or
too high temperature. General operating temperature
range of -10°C ~ +50°C (Fahrenheit temperature is
14°F ~ 122°F). Avoid flooding and rain, minimize dust
and moisture erosion, otherwise camera would be
damaged.
4. Cameras in use should avoid direct sunlight, glare,
otherwise the sensor will be damaged.
5. Do not touch the sensor surface, if any foreign
objects exits, a cotton swab or lens paper can be used
to wipe, if it is difficult to remove, a neutral detergent
diluted with water would be useful. Do not use
corrosive solution.
6 Comments & Special Features:
1) The Ultra AHD Series supports True WDR, which
means that the camera will take two exposures with
different settings and then process it into one.
2) While WDR is off, the two exposures will be used for
AHD and Analog (One exposures for each), and the
output (AHD/TVI/CVI/CVBS) is automatically enabled.
3) While WDR is on, the two exposures are used for
HD Output so the Analog output is disabled automati-
cally.
4) While WDR is on the FPS of the camera drops to
30FPS.
5) Any change in the “Special/System” OSD menu
might result with losing the camera’s image and CoC
control. Please do not make any changes without fully
understanding the consequences.
6) In any case of losing picture/CoC control while the
OSD Menu is still open - disconnect the camera from
power and reconnect it to revert the changes.
OUTPUT M ODE
COLOR SPACE
FRAME RATE
CVBS
USER OFFSET 0~32
VERSION
LANGUAGE
SENSITIVITY
WINDOW TONE
WINDOW USE
WINDOW ZONE
DET H-POS
DET V-POS
DET H-SIZE
DET V-SIZE
ALARM
ON WEIGHT 0%~100%
ON
MOTION
OFF/ON
0~34
0~60
0~34
OFF/ON
SHADING
SPECIAL
0~3
OFF
OFF
0~10
OFF/ON
ENG
、
CHN
SYSTEM
1080P
HD-CbCr
、
YUV
、
SD-CbCr
25/30
、
50/60
PAL
、
NTSC
BLACK LEVEL
FULL
COMP
0~60
ON
COLOR BAR OFF/ON
LENS ADJ L+L+R+R+C
6. In order to make the camera work smoothly and
obtain asatisfactory image, the power cord and video
connection can not be too long, otherwise the increase
of line loss will lead to the inadequate magnitude of the
operating voltage of the camera or video signal
Inadequate.
7. In order to prevent the camera from falling, please
do not place the camera on an unstable bracket, base
or other unstable objects. Otherwise it will lead to
injury, at the same time, the camera will be damaged.
8. The camera cannot be placed near the radiator or
heating resistor.
2 Product Introduction
2.1 Camera Introduction
PROVISION-ISR’s new series of cameras have
adopted a high performance CMOS image sensor
which provides HD resolution and supports high
resolution video output. The cameras support video
transmission distance of around 400M base on Rg59
standard coaxial cable. This series can support
AHD/TVI/CVI/CVBS 960H analog output.
2.2 Product Features
● Dual Coaxial cable with BNC connenctors
● AHD/TVI/CVI/CVBS Output
● True WDR@30fps(Not Available for Analog Output)
● Motorized 2.8-12mm Vari-Focal Auto Focus Lens
● Auto Day/Night (ICR)
● Defog, HBLC, BLC
● 2D/3D Noise Reduction
● Motion Detection, Privacy Mask
3 OSD Controller
3.1 OSD Control:
Center: Enter OSD/ Enter
Up: Navigate OSD up
Down: Navigate OSD Down
Left: adjust OSD Menu values
Right: adjust OSD Menu values
3.2 Lens Cotrol:
Zoom-In: Press UP continuously
Zoom-Out: Press Down continuously
Focus-: Press Left continuously
Focus+: Press Right continuously
3.3 Output adjustment:
AHD: press center for 3 Second and then Right
TVI: press center for 3 Second and then Left
CVI: press center for 3 Second and then Up
4 Control Over Coaxial(CoC)
4.1 AHD/TVI:
Click on “Iris+” button from the DVR’s PTZ interface to
call the OSD Menu. Use the PTZ interface to scroll
through the menu and “Iris+” to confirm.
4.2 CVI:
Click “
►” button from the DVR’s PTZ interface, then
click “ ” and press “Enter” to call the OSD Menu.
5 Product Installation
5.1 General Notes
1. Make sure the unit is powered off before installation.
2. Check power supply voltage consistent with the
electric voltage to prevent voltage unworthy, resulting
in damage to the device.
3. Do not use in the environment beyond the boundar-
ies of the temperature, and maintain good ventilation
to prevent the rain in order to reduce the risk of fire or
electric shock.
4. The installation and maintenance of this product
should be professional, please do not in any way to
remove or modify the equipment; can only use the
required accessories of manufacturers. Problems
caused by unauthorized repair are at your own risk.
5.2 Installation Tools and Information
Prepare the required engineering data and instruc-
tions. Before installation please prepare the following
tools and instrumentation: A straight or a
Phillips-head screwdriver, multi-meter, scissors,
needle nose pliers, tape measure, pencil and so on.
5.3 Installation Method
1. Check the equipment whether it is damaged.
2. Mounting bracket or base.
① If the cement wall, install the expansion screws
(expansion screw holes need stand or base hole), and
then mount bracket or base.
② If the wooden wall, use self-tapping screws to
mount.
3. Mounting the camera
a. Dome Camera
Adjust the lens position and make it aim at the
monitoring points and present a clear picture, manual-
ly fix lens location and adjust the hemisphere cover.
Re-examine the screen whether the character meets
the requirement. Tighten the hemisphere cover.
b. Bullet Camera
Adjust the body so that the lens aims at the monitoring
points and presents a clear picture. Tighten the
screws, to ensure that it does not move.
Note:
The wall needs to bear at least
3X weight of bracket (base) and
camera.
5.4 Connections
Connection as shown in the figure below:
5.5 Lens Control
Use the DVR PTZ interface Zoom+/- to control the
motorized lens.
5.6 OSD Control
The preffered control method is CoC (Control over
Coax). If your AHD DVR supports this function*, Use
the DVR’s PTZ interface to call Preset 95 or press on
“Iris+” to open the OSD menu. Navigate through the
OSD menu by the PTZ direction arrows. “Iris+”
performs as “Enter”.
*All of Provision-ISR’s DVRs support CoC Starting from version 3.4.4
RESET ON
EXIT
OFF
ZONE NUM
H-POS
ZONE DISP
V-POS
H-SIZE
V-SIZE
Y LEVEL
CR LEVEL
CB LEVEL
0~15
OFF/ON
0~60
0~34
0~60
0~34
0~20
0~20
TRANS 0~3
0~20
PRIVACY

12 13
1 CAUTIONS
1. To reduce the risk of electric shock, do not open the
machine and maintain by yourself, please consult a
professional service person.
2. To prevent fire or shock hazard, use the power after
safety certification, the input voltage, current, voltage
polarity and operating temperature must meet the
requirements of this camera.
3. Please note the operating temperature and environ-
mental requirements of the camera, avoid too low or
too high temperature. General operating temperature
range of -10°C ~ +50°C (Fahrenheit temperature is
14°F ~ 122°F). Avoid flooding and rain, minimize dust
and moisture erosion, otherwise camera would be
damaged.
4. Cameras in use should avoid direct sunlight, glare,
otherwise the sensor will be damaged.
5. Do not touch the sensor surface, if any foreign
objects exits, a cotton swab or lens paper can be used
to wipe, if it is difficult to remove, a neutral detergent
diluted with water would be useful. Do not use
corrosive solution.
7 Specifications:
4 in 1 Ultra-AHD camera (1080P)
DI-391AHDU-MVF+
I4-391AHDU-MVF+
Model
Image Sensor
Effective Pixels
Scanning System
Resolution
Min. Illumination
Day & Night
IR LED
OSD Menu
CoC Support
Backlight Compensation
S/N Ratio
White Balance
Noise Reduce
Video Output
Defog
Privacy Mask
Motion Detection
D-Effect
Lens
Power
Operation temp.
Dimension
Net Weight
DI-391AHDU-MVF+
3 LED Array (25m)
129.5*90*119mm
476g
1/3" 2MP Sony Sensor
1945(H)×1097(V)
Progressive
Digital:1920×1080P, Analog:960H*
0.01Lux / (0Lux IR On)
EXT, Color, B&W, AUTO
Available
Yes
AHD/TVI/CVI
≥60dB (AGC Off)
AUTO, AUTOext, Manual
3D-DNR (For AHD/TVI/CVI), 2D-DNR (For Analog*)
AHD/TVI/CVI/CVBS Output
Off/On
Off/On (15 Areas)
Off/On (4 Areas)
Freeze, Mirror
2.8-12mm Motorized with Auto Focus
DC12V±10%, ~400mA DC12V±10%, ~480mA
-10°C~+50°C (14°F~122°F)
I4-391AHDU-MVF+
4 LED Array (40m)
286*77*85.6mm
836g
*Analog video output is not available while WDR is on
6. In order to make the camera work smoothly and
obtain asatisfactory image, the power cord and video
connection can not be too long, otherwise the increase
of line loss will lead to the inadequate magnitude of the
operating voltage of the camera or video signal
Inadequate.
7. In order to prevent the camera from falling, please
do not place the camera on an unstable bracket, base
or other unstable objects. Otherwise it will lead to
injury, at the same time, the camera will be damaged.
8. The camera cannot be placed near the radiator or
heating resistor.
2 Product Introduction
2.1 Camera Introduction
PROVISION-ISR’s new series of cameras have
adopted a high performance CMOS image sensor
which provides HD resolution and supports high
resolution video output. The cameras support video
transmission distance of around 400M base on Rg59
standard coaxial cable. This series can support
AHD/TVI/CVI/CVBS 960H analog output.
2.2 Product Features
● Dual Coaxial cable with BNC connenctors
● AHD/TVI/CVI/CVBS Output
● True WDR@30fps(Not Available for Analog Output)
● Motorized 2.8-12mm Vari-Focal Auto Focus Lens
● Auto Day/Night (ICR)
● Defog, HBLC, BLC
● 2D/3D Noise Reduction
● Motion Detection, Privacy Mask
3 OSD Controller
3.1 OSD Control:
Center: Enter OSD/ Enter
Up: Navigate OSD up
Down: Navigate OSD Down
Left: adjust OSD Menu values
Right: adjust OSD Menu values
3.2 Lens Cotrol:
Zoom-In: Press UP continuously
Zoom-Out: Press Down continuously
Focus-: Press Left continuously
Focus+: Press Right continuously
3.3 Output adjustment:
AHD: press center for 3 Second and then Right
TVI: press center for 3 Second and then Left
CVI: press center for 3 Second and then Up
4 Control Over Coaxial(CoC)
4.1 AHD/TVI:
Click on “Iris+” button from the DVR’s PTZ interface to
call the OSD Menu. Use the PTZ interface to scroll
through the menu and “Iris+” to confirm.
4.2 CVI:
Click “
►” button from the DVR’s PTZ interface, then
click “ ” and press “Enter” to call the OSD Menu.
5 Product Installation
5.1 General Notes
1. Make sure the unit is powered off before installation.
2. Check power supply voltage consistent with the
electric voltage to prevent voltage unworthy, resulting
in damage to the device.
3. Do not use in the environment beyond the boundar-
ies of the temperature, and maintain good ventilation
to prevent the rain in order to reduce the risk of fire or
electric shock.
4. The installation and maintenance of this product
should be professional, please do not in any way to
remove or modify the equipment; can only use the
required accessories of manufacturers. Problems
caused by unauthorized repair are at your own risk.
5.2 Installation Tools and Information
Prepare the required engineering data and instruc-
tions. Before installation please prepare the following
tools and instrumentation: A straight or a
Phillips-head screwdriver, multi-meter, scissors,
needle nose pliers, tape measure, pencil and so on.
5.3 Installation Method
1. Check the equipment whether it is damaged.
2. Mounting bracket or base.
① If the cement wall, install the expansion screws
(expansion screw holes need stand or base hole), and
then mount bracket or base.
② If the wooden wall, use self-tapping screws to
mount.
3. Mounting the camera
a. Dome Camera
Adjust the lens position and make it aim at the
monitoring points and present a clear picture, manual-
ly fix lens location and adjust the hemisphere cover.
Re-examine the screen whether the character meets
the requirement. Tighten the hemisphere cover.
b. Bullet Camera
Adjust the body so that the lens aims at the monitoring
points and presents a clear picture. Tighten the
screws, to ensure that it does not move.
Note:
The wall needs to bear at least
3X weight of bracket (base) and
camera.
5.4 Connections
Connection as shown in the figure below:
5.5 Lens Control
Use the DVR PTZ interface Zoom+/- to control the
motorized lens.
5.6 OSD Control
The preffered control method is CoC (Control over
Coax). If your AHD DVR supports this function*, Use
the DVR’s PTZ interface to call Preset 95 or press on
“Iris+” to open the OSD menu. Navigate through the
OSD menu by the PTZ direction arrows. “Iris+”
performs as “Enter”.
*All of Provision-ISR’s DVRs support CoC Starting from version 3.4.4
This manual suits for next models
1
Table of contents
Other Provision ISR Digital Camera manuals

Provision ISR
Provision ISR I3-330WIP536 User manual

Provision ISR
Provision ISR DI-380A-MVF User manual

Provision ISR
Provision ISR DI-390AHD36+ User manual

Provision ISR
Provision ISR MZ-10A-2(IR) User manual

Provision ISR
Provision ISR Effio-E Dome User manual

Provision ISR
Provision ISR DI-390AEVF User manual

Provision ISR
Provision ISR S3 User manual

Provision ISR
Provision ISR EFFIO-E Series User manual

Provision ISR
Provision ISR DI-390AHDE36+ User manual