PSA Products Panacom PANAIPDS User manual

TCP/IP DOOR PANEL
QUICK SETUP GUIDE
MODEL NO: PANAIPDS

2 3
1. Technical Specifications 4
2. Packing Contents 5
3. Name And Functions Of Each Part 6
3.1 Front And Rear Part 6
4. Connection Diagram 7
4.1 System Layout 7
4.2 Wiring Diagram 8
4.3 Electric Lock Connection 9
5. Installation 10
6. Door Panel Quick Setup 11
6.1 Main Screen 11
6.2 Setup Page 11
6.3 Set Encoder And Device ID 12
6.4 Program Access cards 13
6.5 Copy Cards To Another Door Panel 14
7. Door Panel Manual 15
Please follow these instructions to prevent any personal danger or property loss.
Warning: To avoid death or serious injury
Do not disassemble, install, or repair this product on your own accord
Do not place the product near a hot or humid place
Do not forcibly bend the cord or put a heavy object on the product
Do not use water, thinner or a detergent for removing oil products when
cleaning the exterior
Do not connect to other products while in use
Make sure to clean with a dry cloth to prevent any breakdown or electric
shock
If the product emits a peculiar noise, odour or smoke, immediately
disconnect the power, and then contact PSA Products.
Do not insert the power plug into a 240VAC mains socket with a wet hand
Caution: To avoid personal injury or property loss
Ensure that dust or foreign substances do not collect on the product
Ensure foreign substances do not enter the product
Avoid direct sunlight or heat upon the device
Install the product on a flat & stable location
Unplug the product from AC Mains power if it would not be used for a long time
Do not unplug the micro SD card while recording, as this may cause loss of data
TABLE OF CONTENTS WARNING AND CAUTION

4 5
• 3.5” TFT LCD screen. Resolution: 320*240 pixels
• White LED for night vision
• Wide angle horizontal 128°
• Operating System: Linux System
• Network Connection: POE
• Operating Voltage: 18V (POE)
•
Operation Temperature: -40 ~ 55ºC
• Operating Current: 180 mA (max: 500 mA, stand-by: 90 mA)
• Dust-proof and waterproof (IP64)
• Flush Mounted
• Anti-Vandal
• Dimensions (mm): 318(W) x 130(H) x 51(D).
Main Body Embedded Box DC Connector 2*8 pin connector Quick Setup Guide
M5.1mm Screwdriver
HM M2*5mm
For securing
card reader panel
KA M4*35mm
mounting screws
M4*35mm
plastic expansion pipe
1. TECHNICAL SPECIFICATIONS 2. PACKING CONTENTS

6 7
3.1 FRONT AND REAR PART
NO. Part Name
1Camera
2LED for night vision
3Screen
4Speaker
5 Keypad Buttons
6 Access Card Reader
7 Microphone
8 IR sensor
9 Connection port
10 RJ45 Connector
11 12 V DC power supply
12 Tamper button
13 Screw for xing Access Card Reader panel
4.1 SYSTEM LAYOUT
Remark:
• The distance between devices (indoor monitor, door panel, network switch, guard unit,
and POE Switch) and PoE Switch is limited to 70 meters.
• The system supports up to 98 buildings. Each Building supports a maximum of 19
building panels.
• The system supports a maximum of 19 entrance panels.
• The system supports up to 32 IP cameras.
• One room supports up to 3 monitors.
• The address of other devices can be set only after the first building panel (5-digit:01801,
6-digit:019001) in the system is successfully set.
3. NAME AND FUNCTIONS OF EACH PART 4. CONNECTION DIAGRAM

8 9
4.2 WIRING DIAGRAM
Attention:
• The panel uses its own special POE power supply system. (Part No: PANAIPPOE)
Do not connect the Panel to a standard POE switch!!!
• Ensure correct polarity for all wirings
4.3 ELECTRIC LOCK CONNECTION
Note:
1. Ensure the external power supply is selected to suit the door lock. The door lock power
consumption must not exceed 30VDC @ 2A.
2. The Entrance Panel supports two NO/NC locks, whereas the Block Panel supports only
one NO/NC lock.
3. There are two methods of controlling the Door Lock:
Type 1: Power-on-to-unlock Type 2: Power-off-to-unlock
4. CONNECTION DIAGRAM (CONTINUED)
(Part No: PANAIPPOE)

10 11
CAMERA INSTALLATION LOCATION
Standard installation height of door panel puts the lens about 1550mm above the oor.
Hence, the centre of the camera should be about 1540mm above ground level.
1650
1540
1550
WIRING AND INSTALLATION OF DOOR PANEL
1. Prepare a niche in the wall
measuring 305 x 110 x 45 mm for
installation of the embedded box.
2. Remove the embedded box from
behind the door panel and fix it on
the wall with screws.
3. Install the cable and connect the
system according to the wiring
diagrams in Section 4.
4. Fix the door panel onto the
embedded box and fasten it with
its screw.
5. Fix the access card reader panel
to the door panel with screw.
6.1 MAIN SCREEN
When in standby mode, and if movement is detected, the screen will turn on. A sample
screen, like the following, is displayed. The Button backlight and Access Card Reader
indicator will light up.
Building Panel Entrance Panel
REMARK:
• The IR illumination distance ≤700mm.
• In night vision mode, the Button backlight and Access Card Reader indicator stay lit.
6.2 SETUP PAGE
To enter Setup page
Press: + + 99
Enter password: (Default:0000)
5. INSTALLATION 6. DOOR PANEL QUICK SETUP

12 13
6.3 SET ENCODER AND DEVICE ID
Use or to navigate
Select Device Information + #
Press to select 5 Digit encoding.
Press #to confirm
Press to clear the number.
Enter Building number: eg. 1
Press to move to Device ID
Press to clear the number
Enter Device ID for:
1st Door Panel: 801+ +
(For 2nd Door Panel, enter:
802+ + )
The system will reboot.
Door panel is now ready. Please refer
to Monitor Quick Setup Manual to
continue.
6.4 PROGRAM ACCESS CARDS
Before the access cards are programmed, all the monitors must first be configured into the system.
To enter Setup page
Press: + + 99
Enter password: (Default:0000)
Select “Access” + #
Select “Access Card” + #
Select “Add New Card” + ##
Select Name (Room/Unit Number) to
associate an access card to. Then press #,
the screen will prompt you to present an
access card. Touch an unprogrammed
access card onto the access card reader to
program it. Screen will prompt “successful“.
Press to select another name (Room/
Unit Number) to associate card to unit.
Each room/unit can register up to 5 cards.
6. DOOR PANEL QUICK SETUP (CONTINUED)

14 15
6. DOOR PANEL QUICK SETUP (CONTINUED)
6.5 COPY CARDS TO ANOTHER DOOR PANEL
Select [Copy To] + #to enter door panel
list page;
Select the Door Panel you want to copy to,
and then press #to confirm.
A Building Panel can directly copy access card
registrations to the selected Building Panel.
To download Door Station manual, go to: www.psaproducts.com.au
7. DOOR PANEL MANUAL

17 Millicent Street, Burwood, VIC 3125 Australia
Tel: 1300 PSA PRODUCTS (1300 772 776)
Fax: (03) 9888 9993
Table of contents