Quatro Jet-Stream User manual

© Quatro Air Technologies| JUNE 2019 | All rights reserved |
Operation and Maintenance Manual
Compact Dust Collectors
With i Series Controls
JS-5293 and JHL-5293 Models

© Quatro Air Technologies| JUNE 2019 | All rights reserved |
Jet-Stream Series Operation and Maintenance Manual
Contents
Page 2
Introduction...................................................... 4
Key Features .........................................................................4
Contacting Quatro Air .............................................. 4
Contact Information ....................................................................5
System Contents ................................................. 6
Important Precautions and Instructions ................................ 7
Pre-Startup Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Startup ......................................................... 8
iSeries Controls ................................................. 9
Important Notes for Proper Function of Controls ..............................................9
i Series Controls and Alarms/Status Conditions ..............................................9
Alarm Mute Feature ................................................................10
Light Diagnostics Table (Rev 17.0 and Higher) ...................................................11
Variable Digital Speed Control and AUTOFLOW .............................................13
Remote Operation ....................................................................13
Remote (Automatic) Operation and Remote Status ...........................................14
DB9 Pin Out Information................................................................14
Remote Operation .................................................................15
Remote Status ....................................................................15
Filter Service and Replacement ..................................... 17
Replacement Instructions ...............................................................17
Resetting Service Filters Alert ...........................................................18
Replacement Filter Part Numbers ........................................................19

© Quatro Air Technologies| JUNE 2019 | All rights reserved |
Jet-Stream Series Operation and Maintenance Manual
Contents
Page 3
General Filter Maintenance Guide ........................................................19
Motor Service and Replacement .................................... 20
Motor Access ........................................................................20
Servicing Motors With Quick Change Brushes...............................................21
Motor Replacement ...................................................................22
Troubleshooting ................................................. 24
Specications ................................................... 24
JS Series ...........................................................................24
JHL Series ..........................................................................24
Replacement Parts............................................... 25
Warranty ...................................................... 26
Disclaimer...........................................................................26

© Quatro Air Technologies| JUNE 2019 | All rights reserved |
Jet-Stream Series Operation & Maintenance Manual
Page 4
Introduction
Introduction
Congratulation on your purchase of a Quatro Air Technologies Jet-Stream Series
System—an advanced eective indoor dust and fume collection system designed
specically to remove particulate matter contaminants at the source. You can expect a
noticeable improvement in air quality as the system begins the process of reducing
microscopic airborne particulate.
Key Features
• Compact space saving design
• Health-smart; contains anti-microbial bag lter
• Medical Grade HEPA lter included
• Ultra-quiet performance
• Innite speed control
• Quick access motor compartment
• Customizable for OEM applications
The Jet-Stream normally features 2 stages of ltration:
1. A Bag Filter. This captures large debris.
2. A HEPA Filter for ne harmful particles.
This document contains important safety, Installation, operation, and maintenance instructions.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
WARNING: To reduce the risk of damage to your system read and follow all instructions. Failure to follow these
guidelines may result in undesired operation or damage that will not be covered under warranty.
Contacting Quatro Air
If you require assistance with this or any other Quatro Air product, please call or email technical support
(tech@quatroair.com). We value your comments.
• To help us assist you more eectively with problem reports, the following information may be required when contacting
Quatro Air Support:
• Equipment model (e.g., iVac, AF400, BioScan).
• The serial number of any component you believe to be defective.

© Quatro Air Technologies| JUNE 2019 | All rights reserved |
Jet-Stream Series Operation & Maintenance Manual
Page 5
Contacting Quatro Air
• Actions performed immediately before the problem occurred, if applicable.
• Any additional comments.
Contact Information
Phone
1-877-978-2876 (US and Canada)
1-514-630-4444 (local calling)
Fax
1-514-630-4454
email
General inquiries: info@quatroair.com
Technical Support: tech@quatroair.com
Sales: sales@quatroair.com
Address (Head Oce)
30 Hymus Blvd.
Montreal, Quebec, Canada
H9R 1C9

© Quatro Air Technologies| JUNE 2019 | All rights reserved |
Jet-Stream Series Operation & Maintenance Manual
Page 6
System Contents
System Contents
MODELS NAME ACCESSORIES
JS-5293L-16
JS-5293L-25
JHL-5293
JetStream120V c/w “Innity” Motor
JetStream230V c/w “Innity” Motor
JHL (CADCAM)
• (1) O&M Manual
• (1) Power Cord
• (1) Piece Of The 1.5” Hose (Per Inlet)
• (1) Remote Cable (AE427) Only For iSeries Units
Equipped With DB9 Remote Connector
• For JHL series:
• (1) 6-ft hose with Rubber Cu (PN: H425-06C)
• (1) Auto-Start cable*
* This standard unit ships with a mill-specic Auto-Start cable to connect to your milling machine. Since every Milling Machine has
a dierent Auto-Start plug, this cable will work with ALL milling machines, however you need to adapt it to your machine. Follow
instructions depending on the type of signal your milling machine provides.
For a seamless, automatic and user-friendly operation, opt for QUATRO’s "Custom Kits". These are specic auto-start cables (or hoses
if necessary) to match your milling machine's exact specications, call your dealer to order.

© Quatro Air Technologies| JUNE 2019 | All rights reserved |
Jet-Stream Series Operation & Maintenance Manual
Page 7
Important Precautions and Instructions
Important Precautions and Instructions
This manual contains critical operating information which if not followed may result in undesired operation
and cause damage to the system not covered by warranty. To reduce the risk of severe injury and equipment
damage, read and follow all instructions.
• Read and understand this manual before operating the system.
• Store the manual in a safe place for future reference.
• ALWAYS turn system o and disconnect power prior to accessing unit, replacing lters, or servicing
motor(s).
• To reduce the risk of electric shock, do not expose to excessive moisture, water or rain. Do not
operate the system in areas with excessive moisture
• Ensure to use proper voltage as indicated on the system.
• Use only on a grounded electrical circuit. Do not use any two-prong electrical adapters
(ground lift) to defeat the purpose of three-pronged plug on the end of the cord.
• When servicing the motors, be careful when touching the exterior of the motor as soon as
it has been turned o; it may be hot enough to be painful or cause injury. With modern
motors, this condition is normal when operated at rated load and voltage, as they are built to
operate at higher temperatures.
Allow the unit to cool for 45 minutes before performing any service.
• Do not install or operate the system in an enclosed space or against a wall. Unit may overheat and shut
down. Keep all objects at least 6” away from the casing, especially the discharge grill.
NEVER place the system up against a wall.
• Do not kink hose or restrict airow in any way.
• All lters must be in place whenever this machine is in operation.
IMPORTANT: THE SYSTEM IS DESIGNED TO BE CONSTANTLY POWERED
(PLUGGED IN). USE THE ON/OFF ONLY SWITCH TO TURN THE SYSTEM ON
and OFF.
ALWAYS SWITCH THE POWER OFF BEFORE UNPLUGGING THE SYSTEM
FROM THE MAIN POWER SOURCE OR BEFORE CUTTING POWER TO THE
RECEPTACLE. FAILURE TO DO SO MAY CAUSE DAMAGE TO THE SYSTEM
THAT IS NOT COVERED UNDER WARRANTY.
QUATRO IS NOT LIABLE FOR MISAPPLIED EQUIPMENT. ALWAYS CHECK
SYSTEM VOLTAGE BEFORE PLUGGING INTO POWER SOURCE.
NOTE:)This is a class A product. In a domestic environment, this product may cause radio interference, in which case
the user may be required to take adequate measures.

© Quatro Air Technologies| JUNE 2019 | All rights reserved |
Jet-Stream Series Operation & Maintenance Manual
Page 8
Pre-Startup Checklist
Pre-Startup Checklist
1. Position the unit in the chosen location.
2. Open the lter access panel and install the lters in the correct order. See "Filter Service and Replacement" on page
17 for more info.
WARNING: All lters must be in place before operating the system.
3. Connect the supplied hose (or optional arm) to the Quatro System.
Startup
REMINDER:)Ensure to use proper voltage and sucient amperage as indicated on the system before powering
up the unit.
ONLY USE THE POWER CORD SUPPLIED WITH THE EQUIPMENT.
Always plug the unit directly into the wall outlet. Do not use extension cords or power bars. Ideally the unit should be
plugged into it’s own dedicated circuit.
1. Connect the power cord to the unit and then to the power source.
2. Turn the Jet-Stream System On.
The system does not need to be on all the time nor does it need a warm up period. It can be turned on and o as
needed.
Your Jet-Stream should now be functioning and operational;
3. Adjust controls to desired airow. If noise and suction are acceptable operate at max speed for maximum removal.
NOTE:)The lters in this system are not cleanable. They need to be removed and disposed of periodically.
See "Specications" on page 18 and "Filter Service and Replacement" on page 13.

© Quatro Air Technologies| JUNE 2019 | All rights reserved |
Jet-Stream Series Operation & Maintenance Manual
Page 9
i Series Controls
iSeries Controls
Important Notes for Proper Function of Controls
• Do not connect the power cord to an outlet that is controlled by a switch.
• Never use any form of remote control that switches the power source on and o. In doing so, serious
damage to the controls and motors may occur. Contact QUATRO if power switching is the only way you
have to control the unit remotely.
• Quatro Air has many power switching adapters available for SAFE and reliable control.
i Series Controls and Alarms/Status Conditions
The iSeries controls feature soft touch Power (On/O), Speed Up and Speed Down Buttons. It also features a
series of LEDs that indicate the status of the lter(s) and motor(s) and inform you of any alarms. These alarms
are accompanied by an audible alert.
See the table on the following page to understand the meanings of the LEDs and the alarms.

© Quatro Air Technologies| JUNE 2019 | All rights reserved |
Jet-Stream Series Operation & Maintenance Manual
Page 10
i Series Controls
1. System On LED (L1)
2. Service Motors LED (L2)
3. Service Filters LED (L3)
4. Menu LED: This LED is visible only when the unit is illuminated in Programming mode. It is a menu selection indicator.
5. Remote/Standby LED (L5)
6. Power Button
7. Speed UP button
8. Speed UP button
9. DB9 connector
10. Circuit breaker
11. Power inlet
Alarm Mute Feature
All alarms can be muted for a period of 8 hours OPERATING TIME. After 8 hours, the alarm will return and can be muted
again.
When mute is enabled, L1 Flashes and the muted alarms stay SOLID. The level of the alert will not be displayed until the
8 hour mute period is over.

© Quatro Air Technologies| JUNE 2019 | All rights reserved |
Jet-Stream Series Operation & Maintenance Manual
Page 11
i Series Controls
To mute:
• Press SPD UP and DN quickly at the same time.
When the buttons are released the alarm(s) will mute and L1 will start ashing. Alarm LED will go SOLID.
If there are any additional alarms when MUTED, mute will disable itself until muted again, then BOTH alarms will be
muted.
Muted alarms will only be displayed while the unit is in operation.
If the unit is turned o and then on during the 8 hour mute, the balance of the 8 hour mute will continue after the unit is
turned on again.
Light Diagnostics Table (Rev 17.0 and Higher)
Light
(LED)
Status Audible
Alert
Condition Description/Action
System
ON
LED 1
(L1)
SOLID Unit is ON N/A
Fading
IN-OUT
Temporary ON Mode POWER Button Had Been Used To Temporarily Turn
Unit On While In Remote Mode
See Temporary On Mode on page 14
Flashing
Slowly
AUDIBLE ALERT MUTED Alarm Condition MUTED, See L2 OR L3 For Specic
Alarm Condition
Service Motors
LED 2 (L2)
SOLID Beep Every
4 Hrs
Motor(s) Will Soon Need Service “Quick Change” Brush Motor(s) WILL SOON Require
Brush Replacement
Innity Brush Motor(s) WILL SOON Require Complete
Replacement
Brushless Motor Is Almost At The End Of The Predict-
ed Service Life
RESET ALERT After Service
See "Motor Service and Replacement" on page 20
SOLID Beep Every
15 Min
Motor(s) Service Becoming Urgent “Quick Change” Brush Motors ONLY: Replace Brush-
es ASAP And RESET ALERT
See "Motor Service and Replacement" on page 20
SOLID Beep Every
5 Min
Motor(s) Service
Required
IMMEDIATELY
“Quick Change” Brush Motors ONLY: Replace Brush-
es IMMEDIATELY And RESET ALERT
See "Motor Service and Replacement" on page 20
SOLID Motor Alarm Muted
L1 Flashing Slowly
Replace Brushes OR Motor(s) ASAP And RESET
ALERT
Alarm Mute Details On Previous Page
See "Motor Service and Replacement" on page 20

© Quatro Air Technologies| JUNE 2019 | All rights reserved |
Jet-Stream Series Operation & Maintenance Manual
Page 12
i Series Controls
Light
(LED)
Status Audible
Alert
Condition Description/Action
Service
Filter(s)
LED 3
(L3)
Flashing
Slowly
Filter Pressure High Prepare To Service/Replace Filters
See "Filter Service and Replacement" on page
17
Flashing
Slowly
Beep
Every
Hour
Filter Pressure Near Critical.
Service Becoming Urgent
Replace Filters.
Continued Operation May Result In Unit
Shutdown.
High Pressure Causes Excess Motor Heat
and Accelerates Brush Wear.
See "Filter Service and Replacement" on page
17
Flashing
Slowly
Beep
Every
Sec-
ond
Critical Pressure Unit Has Shutdown To Prevent Damage From
Excess Pressure
Verify Blockage – Remove Blockage
Verify All Filters – Clean/Replace Filters Accord-
ingly
See "Filter Service and Replacement" on page
17 For More Info
SOLID Beep
Every
Hour
Filter(s) Service Life Expired Replace Filter(s) ASAP And RESET ALERT
See "Filter Service and Replacement" on page
17 For More Info and Reset Alert Instructions
SOLID Filter Alarm Muted
L1 Flashing Slowly
Replace Filter(s) ASAP And RESET ALERT
Alarm Mute Details On Previous Page
See "Filter Service and Replacement" on page
17
Remote
Standby
LED 5
(L5)
SOLID Receiving Remote Signal Remote Switch Closed (On) OR Receiving Re-
mote Signal From Another Piece Of Equipment
Fading
IN-OUT
Shutdown Delay Quatro System Continues To Run For 30-45 Sec-
onds To Remove All Debris From Work Area
Flashing
Slowly
Unit Is In Standby Waiting For Remote Switch To Close (Turn On)
OR To Receiving Remote Signal From Another
Piece Of Equipment
ALL LEDS Flashing
Slowly
Beep Every
Second
Low System Pressure Abnormally Low Pressure, Unit will BEEP and Shut-
down In 5 Seconds
Unit Will Continue To Shutdown Unit Until The Issue Is
Addressed
-Motor(s) Not Operating Due To Service Required Or
Failure
See "Motor Service and Replacement" on page 20
-Motors Not Operating Due To Excess Heat.
See "Filter Service and Replacement" on page 17
-Access Door(s) Open. Close All Access Doors
-Filters Not Or Improperly Installed. Verify Filters

© Quatro Air Technologies| JUNE 2019 | All rights reserved |
Jet-Stream Series Operation & Maintenance Manual
Page 13
i Series Controls
Normal (Manual) Operation
Manual operation of the unit is accomplished by using the (Red) POWER button.
Variable Digital Speed Control and AUTOFLOW
Speed control is available in all modes of operation (manual and automatic) and is adjusted with the UP and DOWN
arrows.
AUTOFLOW is an automatic system pressure compensation system. After setting the minimum speed required to
properly evacuate your equipment, the controls will automatically increase the motor speed to compensate for the
increased pressure as a result of lters getting dirty or a system blockage until maximum speed is reached. After a
lter change, system will automatically decrease the speed to the original set point. Please verify that you are achieving
adequate ventilation after a lter change. If not, adjust blower speed.
Remote Operation
Remote Operation Mode simply means that the ON/OFF button on the control panel will be temporarily disabled if the
system is receiving a signal form a remote source to operate.
To enable the remote system startup simply supply a remote signal after the power supply and
remote cable are connected to the system. The Jet-Stream System will respond by illuminating LED 1 (System On) and
LED 5 (Remote/Standby).
Whenever the remote signal is supplied the unit will instantly start, when the remote signal is stopped the unit will stop
after a 30 second delay.
Set the shut o delay in your control software to the shortest possible interval. The Jet-Stream System has a 30-second
delay that cannot be turned o.

© Quatro Air Technologies| JUNE 2019 | All rights reserved |
Jet-Stream Series Operation & Maintenance Manual
Page 14
i Series Controls
NOTE:)When operating by remote control the use of the On/O (Power) button on the panel is disabled while the
Remote/Standby light is ON Solid Or Fading In And Out.
If you wish to use the On/O button on the panel after Remote Operation has been enabled the function is only available
when the Remote/Standby light is ashing slowly. While in operation via the ON/O (Power) button, remote operation is
temporarily disabled. Turn the unit o with the ON/O (Power) button to go back into Remote Operation.
Remote (Automatic) Operation and Remote Status
The Quatro System is designed to be used with other pieces of equipment that can support remote operation and/or
remote status monitoring. The connection is made using the AE427 QUATRO Universal Remote Cable.
QUATRO has some custom remote cables for specic applications. Contact us for more information on available
applications and part numbers. The Quatro System supports Closed Contact and 1-30V AC or DC remote operation as
well as Remote Status signals.
NOTE:)Switching power to control the QUATRO System system remotely WILL NOT WORK and can damage
the unit.
Temporary ON Mode allows you to temporarily override your automatic remote control of the system to perform a quick
cleaning of work surface. Temporary ON Mode is only available when the Remote/Standby (L5) light is ashing slowly.
Use of this mode will temporarily BLOCK OR DISENGAGE all other functions.
To initiate:
• Press POWER (On/O) button to start unit, System ON LED will FADE In-Out, unit will start.
• When you nish using this feature, press POWER (On/O) again. All other functions will be unblocked.
DB9 Pin Out Information
Jet-Streams support remote operation. Connect the AE427 remote cable in between the Quatro System and the other
piece of equipment using only the wires required as per the diagram below.

© Quatro Air Technologies| JUNE 2019 | All rights reserved |
Jet-Stream Series Operation & Maintenance Manual
Page 15
i Series Controls
Remote Operation
• If choosing the Dry Contact (closed contact) remote option, connect the black and red wires to anything that can close
a contact and short these 2 wires together.
• If choosing the 1-30V AC/DC remote option, connect the white and the green wires to the remote signal.
WARNING: RESPECT THE INDICATED POLARITY WHEN MAKING THIS CONNECTION. DO NOT EXCEED 30V
AC/DC.
To enable the remote system startup for either remote option, rst plug the system into power and then connect remote
cable. Then simply have the other piece of equipment close (short) the dry contact or supply a remote control voltage.
When the unit is stopped the QUATRO System will shut down after a short delay.
After Remote Sensing Has Been Activated:
• If the unit is RECEIVING a remote signal: System ON and Remote ON Lights will be FULLY Illuminated
• If the unit is WAITING FOR a remote signal: System ON will be OFF and Remote ON Lights will be FLASHING
Unplugging the power cord will automatically deactivate Remote Sensing Feature.
Remote Status
The System can output status signals to your equipment.
• The Run Signal contact is CLOSED whenever the system is turned on (motor(s) are functioning).
The contact is OPEN when the unit is turned o (motor(s) are not functioning). This includes when the unit goes into
Remote/Standby and if the unit shuts down due to a problem.
Run signal will NOT open when the motor(s) shut o for a lter cleaning when operating in “Online” lter cleaning
mode. Critical Filter Pressure Alarms (high and low pressure) will OPEN the Run Signal and shut the motor(s) o.
• The Fault Signal can be used either with a Normally Open (NO) or Normally Closed (NC) contact depending on
which wire you choose to use (see diagram on previous page).
When there ARE NO alarm conditions present the NO contact will remain open and the NC contact will remain closed.
When there ARE alarm conditions the NO contact will CLOSE and the NC contact will OPEN.
ALL LEVELS of Filter and Motor(s) service alarms will trip the Fault Signal.
The Quatro Run Signal can only shut down the piece of equipment controlling it remotely if the piece of equipment
supports that function. The piece of equipment must be set or programmed to shut itself o when the Quatro Run signal is
OPENED. Contact your equipment manufacturer to verify if your equipment supports that function.
The status signals can either return a “signal” provided by your equipment or output a 12VDC+ or 12VDC-, depending on
how the AE427 remote cable is wired. The Quatro System uses a single “common” for both the Run and Fault Signals.
a. To return a “signal” connect your signal to the Brown wire (Pin 5).
• The “returned” Run signal is available on the Violet wire (Pin 9).
• The “returned” Fault NC (Normally Closed) is available on the Blue wire (Pin 6).
• The “returned” Fault NO (Normally Open) is available on the Orange wire (Pin 7).
b. To be supplied with a 12vdc signal where the + is being switched, connect the Yellow Wire (Pin 8) to the Brown wire

© Quatro Air Technologies| JUNE 2019 | All rights reserved |
Jet-Stream Series Operation & Maintenance Manual
Page 16
i Series Controls
(Pin 5).
• The 12VDC+ Run signal is available across the Violet wire (Pin 9+) and the Black Wire (Pin 1-).
• The 12VDC+ Fault NC (Normally Closed) is available across the Blue wire (Pin 6+) and the Black Wire (Pin 1-).
• The 12VDC+ Fault NO (Normally Open) is available across the Orange wire (Pin 7+) and the Black Wire (Pin 1-).
• Any combination of the Dry Contact, Run Signal and Fault Signal being used means the Black Wire (Pin 1) must
be shared.
c. To be supplied with a 12vdc signal where the - is being switched, connect the Black Wire (Pin 1) to the Brown wire
(Pin 5).
• The 12VDC- Run signal is available across the Violet wire (Pin 9-) and the Yellow Wire (Pin 8+).
• The 12VDC+ Fault NC (Normally Closed) is available across the Blue wire (Pin 6-) and the Yellow Wire (Pin 8+)
• The 12VDC+ Fault NO (Normally Open) is available across the Orange wire (Pin 7-) and the Yellow Wire (Pin 8+).
• Any combination of the Dry Contact, Run Signal and Fault Signal being used means the Black Wire (Pin 1) must
be shared.
Your “signal” will be managed as indicated on the table below. The combination of the Run and Fault Signals can tell you if
the unit is still running but has an alarm condition or if there is an alarm condition and the unit has shut down completely.
Run Signal Contact Fault Signal Contact Condition
Closed NC: Closed
NO: Open
Unit Is Operating Normally
Closed NC: Open
NO: Closed
Unit Is Operating Normally
Motors or Filters Will Require Service Soon
See "Light Diagnostics Table (Rev 17.0 and Higher)" on page 11 For More Info
Open NC: Open
NO: Closed
Unit Has Shut Down
Motors or Filters Require Service Immediately
See "Light Diagnostics Table (Rev 17.0 and Higher)" on page 11 For More Info

© Quatro Air Technologies| JUNE 2019 | All rights reserved |
Jet-Stream Series Operation & Maintenance Manual
Page 17
Filter Service and Replacement
Filter Service and Replacement
Proper maintenance is critical to extend the life of the ltration system. The information presented below outlines basic
maintenance procedures ensuring the unit will provide trouble-free operation for years to come. The Jet-Stream is
designed to allow quick access to the lters.
LED Diagnostic Table - “Service Filter(s)” Alerts (iSeries Controls)
• If “Service Filter(s)” alert is FLASHING SLOWLY most likely the bag lter need to be replaced.
• If “Service Filter(s)” alert is ON SOLID replace the HEPA lter.
Replacement Instructions
Access to all lters is through the lter-side cover for the Jet-Stream System.
1. Unfasten the 2 thumb wheel nuts that secure the lter access panel to the chassis and
remove the panel.
The lter bag is now visible.
2. Slide the lter bag downward o the inlet collar and remove.
The HEPA lter is housed behind a protective grill secured with 2 thumb wheel nuts.
3. Remove the two nuts and lift out the grill.
The HEPA lter is now visible.
4. Replace your lters using the appropriate parts.
NOTE:)Disposal of both odor and particulate lters is the responsibility of the end user. Please contact local authorities
for proper and legal disposal of spent lters.

© Quatro Air Technologies| JUNE 2019 | All rights reserved |
Jet-Stream Series Operation & Maintenance Manual
Page 18
Filter Service and Replacement
Resetting Service Filters Alert
If the Service Filters LED does not extinguish on its own after changing the lters, follow this reset procedure.
1. Ensure lter access door is closed.
2. Plug power back to the unit.
3. When you Press “POWER”, MOTOR WILL START.
4. While motor is operating, press and hold SPD UP and SPD DN simultaneously until unit beeps.
Hold for 10+ seconds; when panel is beeping continuously, release buttons.
In this condition, “System ON” LED is FLASHING quickly.
5. Press SPD DN until “Service Filters” LED is FLASHING.
6. Press and HOLD POWER button while Service Filter(s) LED is FLASHING and unit is BEEPING continuously.
Release button when unit stops BEEPING
7. LED will be OFF and unit will be ready to operate again

© Quatro Air Technologies| JUNE 2019 | All rights reserved |
Jet-Stream Series Operation & Maintenance Manual
Page 19
Filter Service and Replacement
Replacement Filter Part Numbers
Qty Description Part No. Filter Stage
1 (Bag Filter) WHITE Standard (5 Pack) AG143-5 Stage 1
1(Bag Filter)YELLOW Anti-Microbial (5 Pack) AG113-5 Stage 1
1High Capacity lter for JHL series AG208-2 Stage 1
1 HEPA Standard F160 Stage 2
1 HEPA Optional F191S Stage 2
NOTE:)Verify the lter(s) in your Quatro System for the correct part numbers before ordering.
General Filter Maintenance Guide
Stage Filter Reccomended Filter Change Interval iSeries Control Panel
1Bag Filter Every 3 Months None
2HEPA Every 6-18 Months Service Filters Flashing Or ON

© Quatro Air Technologies| JUNE 2019 | All rights reserved |
Jet-Stream Series Operation & Maintenance Manual
Page 20
Motor Service and Replacement
Motor Service and Replacement
The Replacement Indication System will prompt you when it is time to change the motor brushes by illuminating LED 2
and beeping. (See "Light Diagnostics Table (Rev 17.0 and Higher)" on page 11 for details).
If you ignore the warning, the unit eventually will shut down to prevent damage. This will occur even if your Jet-Stream is
in mid operation. It is advised to change the brushes when prompted or ASAP to avoid a shutdown. See "Servicing Motors
With Quick Change Brushes" on page 21.
Determine which type of motor your system has installed and follow the service or replacement instructions.
• ONLY the Quick Change Motor Brushes can be replaced in the eld.
• Innity motors must be replaced at the end of their service life.
NOTE:)Innity Motors Are Considered Consumables And Will Not Be Changed Under Warranty Unless Found To Be
DEFECTIVE Within The Warranty Period.
Consumed Brushes On Innity Motors Are Not Covered under Warranty.
Motor Access
WARNING: Switch unit o and unplug power cord from wall before servicing the
motor(s).
The motor(s) are accessed through the side access panel (opposite the lter
access door).
• Using a Phillips screwdriver, remove the screws along the perimeter of the side
panel opposite the lter side, and lift o the cover with axed sound-damping
foam to expose the motor compartment.
NOTE:)IMPORTANT NOTE FOR UNITS EQUIPPED WITH INFINITY MOTORS—In cases of heavy production
(continuous hours of daily operation), the brushes on the INFINITY Motors may wear before the warranty is over.
Motors are designed to operate 2000-3000 hours and then be replaced. In some extreme cases motor life can even be
less than 2000 hours and this is usually due to the system being run at a high pressure (dirty lters) for extended periods
of time.
Motor compartment
Cover w/ sound-damping foam