Quell Q10YHL User manual

PHOTOELECTRIC
SMOKE ALARM
User Manual
10 Year sealed battery
Model: Q10YHL, Q10YL, Q10YB
Photoelectric smoke alarms are designed to detect
visible particles (associated with slow smouldering res).
Quell®is a registered trademark of Kidde Australia Pty Ltd
Copyright © 2021 Kidde Australia Pty Ltd. All rights reserved
0312-7202-01 11/21
P/N:137069 (Model Q10YL), 137065 (Model Q10YB), 137066 (Model Q10YHL)
AS3786:2014
Lic: SMK1377
SAI Global
©2021 Carrier. All Rights Reserved.
Q10YHL
Q10YL
Q10YB

IMPORTANT: READ ALL INSTRUCTIONS BEFORE INSTALLATION
AND KEEP THIS MANUAL NEAR THE ALARM FOR FUTURE REFERENCE
CONTENTS OF THIS MANUAL
1. Product Features................................................................................. 1
2. Product Specications........................................................................2
3. Recommended Locations for Alarms................................................3
4. Locations to Avoid...............................................................................7
5. Installation............................................................................................8
6. Operating and Test............................................................................. 9
7. Nuisance Alarms and Hush Function............................................... 10
8. Alarm Visual and Audible Indicators................................................ 10
9. BATTERY...............................................................................................12
10. Cleaning Your Alarm......................................................................... 13
11. Limitations of Smoke Alarms.......................................................... 13
12. Good Safety Habits...........................................................................14
13. What to do When the Alarm Sounds...............................................15
14. Warranty & Contact Details............................................................. 17
Thank you for purchasing this smoke alarm. It is an important part of
your family’s home safety plan. You can trust Quell to provide the highest
quality safety products.
Please take a few minutes to thoroughly read this user guide, and save
it for future reference. Teach children how to respond to the alarms, and
that they should never play with the smoke alarm.
If you have any questions about the operation or installation of your
alarm, please call our toll free Customer Service at 1800 654 435

1
IMPORTANT: READ ALL INSTRUCTIONS BEFORE INSTALLATION
AND KEEP THIS MANUAL NEAR THE ALARM FOR FUTURE REFERENCE
1. Product Features
Model Q10YL/Q10YB/Q10YHL is powered from a non-replaceable
battery. The smoke alarm ensures protection in the event of a power
failure.
• Hush feature silences nuisance alarms for up to 10 minutes.
• The smoke alarm will sound a short beep about once every 40
seconds if the battery is low.
• Red LED ashes every 60 seconds for 10 minutes following power on
or reset. After initial 10 minutes, LED will ash once every 10 minutes
to indicate it is working normally, or is in alarm(Red LED ashing
every second).
• Loud alarm sounder – 85 dB
• Test button checks smoke alarm operation.
• After ten (10) years of cumulative power up, the smoke alarm will
“chirp” two times every 30 seconds. This is an “operational end of
life” feature which will indicate that it is time to replace the alarm.
The smoke alarm is a sealed unit, return to supplier for any repairs.

2
2. Product Specications
Model Q10YL
Q10YHL with Light
Q10YB with Voice
Electrical Rating 3V sealed lithium battery
Sensor Photoelectric
Operating Temperature 0 °C to 40°C
Operating Humidity Up to 93% Humidity
(Non-Condensing)
Storage and Transport
Conditions
-20° C to +60° C, 5-95%RH
(non-condensing)
Loud alarm 85 decibels at 3 metres

3
3. Recommended Locations for Alarms
Laws on smoke alarms vary from state to state and you should
be aware of what the requirements are in your state - for more
information please refer to your local re emergency services or
state regulations.
Recommended Locations
• In each room where an occupant sleeps with the door closed. (A
closed door may prevent an alarm located outside the room from
waking the occupant).
• In the immediate area of bedrooms and the exit path from all sleeping
areas (Figure 1A).
• In stairwells, as stairwells act like chimneys for smoke heat. see
Figure 1B.
• In any room where large electrical appliances are operated
(e.g. portable heaters or humidiers).
• If a hallway or room is more than 7m long install alarms at both ends.
• For maximum household protection see Figure 1C.
Things to Consider
For Ceiling Mounting:
Smoke, heat and other combustion products will rise to the ceiling and
spread horizontally. Mounting the alarm in the centre of the ceiling
positions it closest to all points in the room.
• When mounting an alarm on the ceiling, locate it at a minimum of
300mm from the side wall (Figure 2A).
• For sloped, peaked or cathedral ceilings the alarm should be placed
between 500mm and 1500mm from the highest point of the ceiling
(Figure 2B).
• The alarms in rooms with ceiling slopes greater than 1m in 8m
horizontally, should be located on the high side of the room
(Figure 2B).
For Wall Mounting:
• When mounting the alarm on the wall, use an interior wall with the
top edge of the alarm at a minimum of 100mm and a maximum of
300mm below the ceiling (Figure 2A).

4
3. Recommended Locations for Alarms
DINING
ROOM
LIVING
ROOM
KITCHEN BEDROOM
BEDROOM
BEDROOM
LIVING
ROOM KITCHEN
BEDROOMBEDROOM HALL
BASEMENT
Figure 1A
Figure 1C
Figure 1B
SINGLE FLOOR PLAN MULTIPLE FLOOR PLAN
BEDROOM
FAMILY ROOM
WORKSHOPBASEMENT
KITCHEN
HALL
GARAGE
MASTER
BEDROOM
FIRE
EXTINGUISHERS
SMOKE
ALARMS
FIRE BLANKET
TOTAL HOME PROTECTION
Smoke Alarms for Minimum Protection
Smoke alarms for Additional Protection
Not within 3m of cooking appliances

5
3. Recommended Locations for Alarms
CEILING
300 mm
MINIMUM
MINIMUM
MAXIMUM
SIDE WALL
BEST
PLACEMENT
ACCEPTABLE
PLACEMENT
DO NOT INSTALL
DEADAIR
NOT IN
THIS AREA
ANYWHERE IN THIS
AREA
500 mm
1000 mm
DEAD AIR
DO NOT INSTALL
Figure 2A
300 mm
CEILING APEX
100 mm

6
3. Recommended Locations for Alarms
NOT IN
THIS AREA
ANYWHERE IN THIS
AREA
SLOPED CEILING
1000 mm
500 mm
DEAD AIR
DO NOT INSTALL
Figure 2C
Figure
• When mounting the alarm on a sloping ceiling, it should not exceed
1500mm away from the apex. The spacing of additional alarms, if
any, should be based on a horizontal distance measurement, not a
measurement along the slope of the ceiling (see Figure 2B )
2B
• In rooms with open joists or beams not exceeding 300 mm, ceiling
mounted alarms shall be located on the bottom of such beams. (See
Figure 2C )
• Alarms installed on an open-joist ceiling shall have the smooth ceiling
spacing reduced to no more than half of the listed spacing when
measured at right angles to the solid joist. (See Figure 2C)
The alarm should be
located between 500
mm and 1500 mm of
the highest point.

7
3. Recommended Locations for Alarms
Mobile Home Installation:
For Well Insulated Mobile Homes
Install alarms as recommended on the previous pages.
In mobile homes that are not well insulated extreme heat or cold can
be transfered through poorly insulated walls and roofs. This may create
a thermal barrier which can prevent the smoke from reaching an alarm
mounted on the ceiling.
For Poorly Insulated Mobile Homes
Install the alarm on an inside wall with the top edge of the alarm at a
minimum of 100mm and a maximum of 300mm below the ceiling
(Figure 2A).
For minimum protection, install at least one alarm close to the bedrooms.
For additional protection, see Figure 1A.
Warning: test your alarm operation after caravan or mobile
home vehicle has been in storage, before each trip and at least
once a week during use.
4. Locations To Avoid
!
• Smoke alarms should not be installed within 0.9m(3 ft)
• of the door to a bathroom containing a tub or shower
• forced air supply ducts used for heating or cooling
• ceiling or whole house ventilating fans
• other high air ow areas
• Areas where curtains or other objects will block the sensor. Smoke
must be able to reach the sensor to accurately detect conditions.
• Install at least 300mm away from a light tting.
• No closer than 400 mm outside the circumference of a ceiling fan.
• Keep out of insect infested areas.
• Avoid excessively dusty, dirty or greasy areas.
• Do not install in areas where the temperature is colder than 0°C or
hotter than 40°C.
• Do not install in areas where the relative humidity (RH) is greater
than 93%.
• Normal cooking may cause nuisance alarms. If a kitchen alarm is
desired, it should have an alarm silence feature and should not be
installed within 3m of cooking appliances.
• Avoid dead air spaces such as the peak of an “A” frame ceiling.
“Dead Air” at the top may prevent smoke from reaching the alarm in
time to provide early warning. Refer to Figure 2A and 2B.
Note: Smoke alarms are not to be used with detector guards unless
the combination (alarm and guard) has been evaluated and found
suitable for that purpose.

8
5. Installation
ATTACHING MOUNTING PLATE
OPTION 1:
Easy Mount – Drywall Only
1. Choose a mounting location (wall or ceiling)
and drill a 3/16”(5mm) diameter hole at least
1/2”(12mm) deep.
2. Insert the provided screw through the
mounting plate aligning the ribs on the screw
with the slots on the mounting plate.
3. Tighten the screw/mounting plate to wall or
ceiling until mounting plate is snug against
surface. DO NOT over-tighten.
OPTION 2:
Mounting on Other Surfaces
1. Choose a mounting location (wall or ceiling)
and using the mounting plate provided as a
template, mark three-hole locations.
2. Install the three provided screws through the mounting plate and tighten.
DO NOT over-tighten screws. (If mounting in plasterboard or similar sur-
face, drill 3/16”(5mm) holes and use the plastic anchors provided.)
Anchors are not required for mounting on hard surfaces such as wood.
ATTACHING AND ACTIVATING THE ALARM
This model is equipped with a feature that
automatically activates the alarm when the
alarm is attached to the mounting plate for
the rst time. Once activated, the battery will
supply power to the alarm for the life of the
alarm (10 years) under normal conditions.
Align the alarm with the mounting plate and
rotate clockwise (right) approximately 20°,
until the unit stops and clicks into place. DO
NOT over-tighten.
If unit needs to be re-aligned, rotate the alarm
counter clockwise, remove and rotate to
desired alignment.
NOTE: The alarm will mount to the plate in one position.
When mounting, the side rib (see picture below) on
the plate should be aligned to t with the bigger
slot (see picture below) on the back of the alarm.
You will know power has been supplied when
alarm briey chirps. Unit will remain on until unit
is disabled by the user at alarm’s end of life. Do
not over tighten the alarm as damage to alarm or
mounting surface may occur.
The alarm is now activated! After installation/
activation, test your alarm as described in
Operation and Testing section.
WARNING: Failure to properly install and activate this alarm will prevent
proper operation of this alarm and will prevent its response to re hazards.
Quell® Long-Life “Bedroom” smoke alarm model Q10YB (
137065
) will issue a
voice prompt at activation asking the user to press the test button.
!
Ribs (2
places)
Mounting Option 1
Slots
Mounting
Option 2
Bigger slots
Side rib

9
6. Operation And Test
The smoke alarm is operating once it is activated and testing is com-
plete. When the smoke alarm senses smoke, the horn will sound a loud
(85db) pulsating alarm( 3 beeps repeating).
Red LED indicator:
This smoke alarm features a red LED indicators that can be seen through
the Push-to-Test button.
RED
Red LED will ash every 60 seconds for 10 minutes following power
on or reset. After initial 10 minutes, LED will ash once every 10
minutes.
– Indicating normal operation.
Red LED Flashes once a second
– Smoke alarm senses smoke and simultaneously sounds an
audible alarm
Red LED Flashes once every 10 seconds
– Smoke alarm is in hush mode.
Testing the smoke alarm
Test the unit, to ensure proper operation, by pressing the Test/Hush
button for at least 5 seconds (or until the unit sounds). This will sound
the alarm if the electronic circuitry, horn, and battery are working.
CAUTION: Due to the loudness (85 decibels) of the alarm, stand at
arm’s length from the smoke alarm when testing. The alarm sounder is
loud to alert you to an emergency and can be harmful to hearing when
you are too close.
Test the smoke alarm weekly and upon returning from holiday, or when
the house has been unoccupied for several days.
NOTE: WEEKLY TESTING IS RECOMMENDED.
WARNING: If alarm sounder activates, and smoke alarm is not
being tested, the smoke alarm is sensing smoke. THE ACTIVATION
OF THE ALARM SOUNDER REQUIRES YOUR IMMEDIATE
ATTENTION AND ACTION.
!
!

10
7. Nuisance Alarms and Hush Function
This alarm is designed to minimise nuisance alarms. Cigarette smoke will
not normally cause the unit to alarm, unless the smoke is blown directly
into the alarm. Combustion particles from cooking may set off the alarm
if it is located too close to a cooking appliance. Large quantities of
combustible particles are generated from spills or when boiling. Using
the fan on a range hood which vents to the outside (non-recirculating
type) will also help prevent nuisance alarms from occurring by removing
these combustible products from the kitchen.
HUSH
If you know why the alarm is sounding, and you can verify that it is not
a life threatening situation, you can push the button on the alarm to
silence the alarm for up to 11 minutes. If the smoke is not too dense,
that alarm will silence. After the Hush period, the smoke alarm will
automatically reset and sound the alarm if particles of combustion are
still present. You can use Hush repeatedly until the air has been cleared
of the condition causing the alarm.
Note: Dense smoke will override Hush and sound a continuous
alarm. If no re is present, check to see if one of the reasons listed
in page 7. LOCATIONS TO AVOID may have caused the alarm. If a re
is discovered, exit the building and call the re brigade.
The following tables describes the visual and audible alarm conditions
the unit may report and illustrates how the unit will indicate normal
standby, alarm and error conditions.
Alarm
Mode
Model Visual Indications Audible
Indications
Smoke
or Fire
detected
Living Area
Model
Q10YL
Part No. 137069
3 blinks
synchronized with
audible alarm
3 long
beeps(ISO8201),
repeating
Bedroom with Voice
Model Q10YB
Part No.
137065
3 blinks
synchronized with
audible alarm
3 long
beeps(ISO8201),
repeating with
voice “Fire”
announced
Hallway with
Emergency
Safety Light
Model Q10YHL
Part No.
137066
3 blinks
synchronized with
audible alarm
& amber light
illuminated
3 Long beeps(ISO
8201), repeating
If you require further information please contact Service on 1800 654 435
or visit our website at www.quell.com.au.
8. Alarm Visual and Audible Indicators

11
Operational
Mode
Model Visual
Indications
Audible
Indications
Note:
Normal
Operation
All Flash once
every 60
seconds
None LED will flash
every 60
seconds for
10 minutes
following power
on or reset.
After initial
10 minutes,
LED will flash
once every 10
minutes
Test/Hush
Button
Press
All Flash with each
alarm pattern
Two sets of
3 long beeps
Test/Hush
button press
will initiate test
sequence
Q10YB
137065
Voice “Fire”
announced
“Bedroom”
smoke alarm
with voice
Model Q10YB
Part No. 137065
Smoke
Alarm
Hush
All Flash once
every 10
seconds
None (smoke
alarm
silenced)
Alarm hush
feature silences
smoke alarm
for approx.
10 minutes.
See page 13
for additional
instructions.
Low Battery All Flash once
every 30
seconds
Chirp every 60
seconds
Chirp every 60
seconds
Q10YB
137065
Voice “Low
Battery”
announced
“Bedroom”
smoke alarm
with voice
Model Q10YB
Part No.137065.
Fault Mode All Fault code (2-12
flashes every
30 seconds)
Chirp every 30
seconds
Remove, turn
off and replace
alarm
End of Unit
Life*
All 2 Flash every
30 seconds
2 chirps every
30 seconds
Remove, turn
off and replace
alarm
* End of life hush feature. Silences end of life indication 3 days at a time
for a maximum of 30 days.
8. Alarm Visual and Audible Indicators

12
End of Life Hush™
This alarm has End of Life Hush™ which allows you to silence the trouble
chirp for three days giving you extra time to replace the unit at a more
convenient time. To activate, press the Test/Hush button. While in the End
of Life Hush™ mode, the alarm will still detect Smoke.
The End of Life signal can be reset a maximum of 10 times for a total of 30
days. After 10 resets the end of life signal can no longer be silenced and
the alarm must be replaced immediately.
8. Alarm Visual and Audible Indicators
BATTERY ACTIVATION
The battery automatically activates when the alarm is attached to the
mounting plate for the rst time.
NOTE: One Lithium battery, permanently sealed inside the alarm, powers
this unit; no battery installation or replacement is necessary for the life
of the alarm.
IMPORTANT: Constant exposure to high or low humidity may reduce
battery life.
WARNING! DO NOT ATTEMPT TO OPEN THE ALARM FOR ANY REASON!
Do not try to repair the smoke alarm yourself. No serviceable parts included.
Low battery: This alarm is equipped with a low battery monitor circuit
which will cause the alarm to produce a single “chirp” approximately
every 60 seconds and blink the Red LED every 30 seconds, for 30 days
should the battery become low.
The unit must be replaced within 30 days of the rst occurrence of the
“Low Battery Warning” to provide continuous alarm protection.
END OF UNIT LIFE: WHEN THE END OF UNIT LIFE STATUS (SEE
SECTION 8: ALARM VISUAL AND AUDIBLE INDICATORS) HAS
BEEN REACHED PLEASE PRESS AND RELEASE THE WHITE SMALL
SQUARE BUTTON TO POWER OFF THE ALARM. DISPOSE OF ALARM
AFTERWARDS. SEE BELOW IMAGE.
!WARNING: ONCE THIS BUTTON IS PRESSED THE UNIT WILL NO
LONGER DETECT SMOKE.
9. BATTERY
!
Small square button
END OF UNIT LIFE:
Two chirps every 30 seconds
indicates the end of unit life.
Pressing the Test/Hush button
will stop the end of unit
life signal for 3 days.
Press and release the
white small square button
to power off the alarm
when END OF UNIT LIFE
status has been reached.
Dispose of Alarm Afterwards!
This model automatically
activates when the alarm is
attached to the mounting plate
for the first time.

13
YOUR ALARM SHOULD BE CLEANED AT LEAST ONCE A YEAR
To clean your alarm, remove it from the mounting bracket. You can clean
the interior of your alarm (sensing chamber) by using compressed air or
a vacuum cleaner hose and blowing or vacuuming through the openings
around the perimeter of the alarm. The outside of the alarm can be
wiped with a damp cloth.
After cleaning, reinstall your alarm and test your alarm by using the test
button. If cleaning does not restore the alarm to normal operation the
alarm should be replaced.
After cleaning, reinstall your alarm and check that the Red LED
ashes once every 60 seconds. Then test your alarm by using the
test button.
10. Cleaning Your Alarm
11. Limitations Of Smoke Alarms
Warning! Smoke alarms are devices that can provide early
warning of possible res; however, alarms have sensing limitations.
Ionisation sensing alarms may detect invisible re particles (associated
with fast aming res) sooner than photoelectric alarms. Photoelectric
sensing alarms may detect visible re particles (associated with slow
smouldering res) sooner than ionisation alarms.
Home res develop in different ways and are often unpredictable.
For maximum protection, subject to applicable legal requirements in
each State and Territory, Quell recommends that both ionisation and
photoelectric alarms be installed.
Loose batteries, where tted, must be of the specied type, in good
condition and installed properly. AC only powered alarms will not operate
if AC power has been cut off such as by an electrical re, an open fuse
or loss of mains supply. All alarms must be tested regularly to make sure
the batteries and the alarm circuits are in good operating condition.
Life safety from re in residential occupancies is based primarily on
early notication to occupants of the need to escape, followed by the
appropriate egress actions by those occupants. If the alarm is located
outside the sleeping room or on a different oor, it may not wake up a
sound sleeper. The use of alcohol or drugs may also impair one’s ability
to hear the smoke alarm. For maximum protection, a smoke alarm
should be installed in each sleeping area on every level of a home.
Smoke alarms cannot provide an alarm if smoke does not reach the unit.
Therefore, smoke alarms may not sense res starting in chimneys, walls,
on roofs, on the other side of a closed door or on a different oor.
Hearing impaired occupiers should consider tting additional
accessories to give a visual or tactile(Vibrating pad) alarm.
Although smoke alarms can help save lives by providing an early
warning of a re, they do not prevent property damage. Home owners
and renters should have adequate insurance to protect their property. If
after reviewing this user guide you feel that your smoke alarm isdefective
in any way,do not tamper with the unit. Refer to Section 14 Warranty and
Contact Details.
!

14
12. Good Safety Habits
DEVELOP AND PRACTICE A PLAN OF ESCAPE:
• Install and maintain re extinguishers on every level of the home
and in the kitchen, basement and garage. Know how to use a re
extinguisher prior to an emergency.
• Make a oor plan indicating all doors and windows and at least two
(2) escape routes from each room. Second story windows may need
a rope or chain ladder.
• Have a family meeting and discuss your escape plan, showing
everyone what to do in case of re.
• Determine a place outside your home where you all can meet if a
re occurs.
• Familiarise everyone with the sound of the alarm and train them to
leave your home when they hear it.
• Practice a re drill at least every six months, including re drills at
night. Ensure that small children hear the alarm and wake when it
sounds. They must wake up in order to execute the escape plan.
Practice allows all occupants to test your plan before an emergency.
You may not be able to reach your children. It is important they know
what to do.
• Current studies have shown alarms may not awaken all sleeping
individuals. It is the responsibility of individuals in the household that
are capable of assisting others to provide assistance to those who
may not be awakened by the alarm sound, or to those who may be
incapable of safely evacuating the area unassisted.

15
13. What To Do When The Alarm Sounds
• Leave immediately by your escape plan. Every second counts, so
don’t waste time getting dressed or picking up valuables.
• While leaving, don’t open any inside door without rst feeling its
surface. If hot, or if you see smoke seeping through cracks, don’t
open that door! Instead, use your alternate exit. If the inside of the
door is cool, place your shoulder against it, open it slightly and be
ready to slam it shut if heat and smoke rush in.
• Stay close to the oor if the air is smoky. Breathe shallowly through
a cloth, wet if possible.
• Once outside, go to your selected meeting place and make sure
everyone is there.
• Call the re department from your neighbour’s home - not from
yours!
• Don’t return to your home until the re ofcials say that it is all right
to do so.
• There are situations where a smoke alarm may not be effective to
protect against re.
For instance:
a) smoking in bed
b) leaving children home alone
c) cleaning with ammable liquids, such as petrol

16
TEN YEAR WARRANTY
Warranty
Quell warrants to the original consumer purchaser that each new alarm
will be free from defects in materials and workmanship under normal
use for a period of 10 years from the date of purchase. To the extent
permitted by law, Quell agrees to repair or replace (at our discretion)
any defective product on presentation of the proof of purchase.
Australia warranty claims:
Where the goods are offered for sale in Australia, the benets to the
consumer given by this warranty are in addition to other rights and
remedies of the consumer under the Australian Consumer Law and
other applicable laws relating to the goods. Our goods come with
guarantees that cannot be excluded under the Australian Consumer
Law. You are entitled to a replacement or refund for a major failure
and compensation for any other reasonably foreseeable loss or dam-
age. You are also entitled to have the goods repaired or replaced if the
goods fail to be of acceptable quality and the failure does not amount
to a major failure.
New Zealand warranty claims:
Where the goods are offered for sale in New Zealand, the benets to
the consumer given by this warranty are in addition to other rights and
remedies of the consumer under relevant New Zealand consumer pro-
tection laws and other applicable laws relating to the goods. Our goods
come with guarantees that cannot be excluded under relevant New
Zealand consumer protection laws. You are entitled to a replacement or
refund for a major failure and compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the goods
repaired or replaced if the goods fail to be of acceptable quality and the
failure does not amount to a major failure.
Exclusions
Subject to non-excludable laws, this warranty does not cover:
• normal wear and tear to the product or parts
• batteries or other consumables included with this product (excluding
sealed non replaceable battery models)
• damage to the product caused by accidents, misuse, abuse, lack
of reasonable care, tampering or repair by a person not authorised
by Quell
• any product that has not been installed, operated or maintained in
accordance with the manual or operating instructions provided with
the product
• any damage caused by improper power input or improper cable
connection
• any indirect, special or consequential loss or damage of any kind
13. Warranty & Contact Details

17
To make a claim
If a defect in the product appears within the time frame stated,
you are entitled to submit a warranty claim by returning your
product to the address shown below. Please contact Quell on the
telephone numbers provided below, Monday to Friday during
9.00AM - 5.00PM. When returning the product, please ensure it is
properly packaged so that no damage occurs during transit. Any
postage and packaging expenses required to return the product to
Quell will be at your cost.
Please provide the original or a copy of the proof of purchase.
Also, please make sure you have included an explanation of the
problem.
If Quell elects to repair the product, please note that goods
presented for repair may be replaced by refurbished goods of the
same type rather than being repaired. Refurbished parts may be
used to repair the goods.
14. Warranty & Contact Details
This warranty is provided by:
Kidde Australia Pty Ltd
ABN 68 006 252 428
10 Ferntree Place, Notting Hill, Vic, 3168
Telephone: 1800 654 435
Website: www.quell.com.au
ABN 68 006 252 428
Made in China
This manual suits for next models
2
Table of contents
Other Quell Smoke Alarm manuals
Popular Smoke Alarm manuals by other brands

Trader
Trader Bear BESMOKEY4 Installation and user manual

Ramtech Electronics
Ramtech Electronics WES+ Installation and operation manual

emerald alarms
emerald alarms EP-VC-240-10 user manual

SITERWELL ELECTRONICS CO.,LIMITED
SITERWELL ELECTRONICS CO.,LIMITED GS522 user manual

Halma
Halma Ampac TITANUS PRO-SENS Technical manual

Trox
Trox RM-O-3-D OPERATING AND INSTALLATION Manual