MI CT 05 00000
Series
EPXB
BMA #8 PIN CONTACT :
ASSEMBLY INSTRUCTIONS
FOR .085 cable
Issue
April 12, 12 Page
1 / 2
CREATION
NAME : A. LEBOCQ
DATE : 12/04/2012
APPR.
Y. LE GLOAHEC
ISSUE REVISIONS NAME APPROVED
NOTE:
•We recommend a cable thermal preconditioning before assembly.
STEP 1:
•Take the tool kit R282 120 000.
•Strip the dielectric of the cable up to the center conductor.
- Stripping tool: R282 051 000.
•Trim cable center conductor.
- Pointer gauge: R282 063 000.
•Clean the cable.
STEP 2:
•Slide the centering boot or the sealing boot.
•Slide the solder sleeve onto the cable.
•Position the solder sleeve flush against the solder barrel gauge and solder to the cable or align with the
outer contact.
-Solder barrel gauge : R282 744 300.
Center conductor
Dielectric + jacket
Centering boot
Sealing boot
Solder sleeve
Solder barrel gauge
Solder detail