RadonFTLab RadonEye Plus 2 User manual

FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
Smart Radon Gas Monitor
RADONEYE +
Operation Manual
RD200P2
•Type : pulsed ion chamber
•First reliable data out : < 60min
•Data interval : 10min update (60min moving average)
•Sensitivity : 0.5cpm/pCi/l at 10pCi/l (30cph/pCi/l)
•Operating range : 10℃ ~ 40℃ (50°F ~ 100°F), RH < 80%
•Measurement range : 0.1 ~ 255 pCi/l (9,435 Bq/㎥)
* Environment reference value 4pCi/l (148 Bq/㎥)
•Precision : < ±10% at 10pCi/l
•Accuracy : < ±10% (min. error <±0.5pCi/l ) at 10pCi/l
•Interval of measurement value saving : 60 minutes
•Storage capacity : 1 year
•Power consumption : DC12 ± 0.1V, 0.1A ( Use 12V DC adapter)
•Size : Φ80(mm) x 120(mm)
•Display : 0.96 inch OLED
•Data communication : Wi-Fi (internet), Bluetooth
•Weight : 520g
•Altitude : Up to 2000 m
•pollution degree : 2
* Radon Eye Plus 2 is a function upgraded version of Radon Eye Plus that enhances
Wi-Fi setup convenience by adding BLE communication to previous Radon Eye Plus
products.
* In March 2019, the model name of RadonEye Plus2 changes from RD200P to
RD200P2.
Product Specifications
Descriptive labeling in accordance with Quality
Management and Safety Control Act for Industrial Goods.
Instrument type: RD200P2
Instrument name : RADONEYE +
Kind : For home(indoor) use
Material : ABS
Manufactured date : Indicated separately
Manufacturer : FTLab
* Only the manufacturer or agency will inspect and supply
Country of manufacture : Republic of Korea
Questions : www.radonftlab.com
FTLAB succeeded in developing a real-time Radon
sensor in 2015, and also succeeded in mass production
in 2016, we launched RADON FTLAB.
COPYRIGHT (C)FTLAB Co., Ltd ALL RIGHT RESREVED.
503ho, 8, 330beon-gil,
Haebong-ro, Danwon-gu,
Ansan-si, Gyeonggi-do, Korea
FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
① BLE access : Indicates it is connected with smartphone using BLE communication
② Shock detect sign : It appears when a shock or vibration from outside is sensed, and
the measurement stops at the time
③ Radon concentration : Measured value of Radon shown in 10 minute interval
④ Unit of measure : Shown in pCi/l or Bq/㎥. Unit can be changed by smartphone app.
⑤ Information display : SN, peak value, 1/2/7 day and month average, measurement time,
pulse count per 10 minute measurement (present value/last value)
Name and function of each part
BLE Access
Shock detection
Radon concentration
Unit
Information
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Name and function of each part
Front
LED : Red LED flashes for 30 seconds when Radon value exceeds
reference value.
Green LED flashes when Wi-Fi connection is not normal.
Ventilation window
LCD : Information display window for Wi-Fi access, shock detection,
Radon concentration, etc.
Rear
Power
12V DC
Radon ?
1. Radon is a colorless, odorless and tasteless radioactive gas.
Radon, a gas originating from radium which is generated by the collapse of
uranium in soil, is everywhere on earth. It penetrates indoors mainly from the
ground or building materials. The gases that cause sick house syndrome and
other noxious gases luckily smell. Urban gas and LPG were deliberately
smelled. However, radon does not smell nor can be seen. And no matter how
many years have passed, it is constantly released from the wall, ceiling and
floor.
2. Radon is 8 times heavier than air and is easily concentrated in the house.
Radon has the half-life of 3.8 days and makes alpha decay. The alpha particle
emitted from radon has the smallest penetration power among the radiation
rays and can not penetrate even a single piece of paper, but its destructive
power is so great that the cells are damaged if they are directly impacted by
radon, even having a nickname of "silent murderer". This is why radon detec-
tion sensor is absolutely needed in home.
3. Radon gas causes lung cancer.
Three causes of modern female lung cancer are passive smoking, ultrafine
particles and radon. When radon gas enters the lung through breathing, alpha
particles released from radon damage the lung cells. Since once destroyed
lung cells are not regenerated, prolonged exposure to high concentration of
radon gas will increase the likelihood of lung cancer. Therefore, the United
States Environmental Protection Agency(EPA) designated Radon as a must
be managed hazardous gas for healthy life.
- Accurate measurement value of the average radon level can be obtained when
the house is empty for 1 or 2 days.
- Reliable value can be obtained about 1 hour after start of the measurement.
- Radon concentration in the house is generally high at dawn and low at daytime,
so continuous measurement for more than 24 hours is necessary.
Precautions
•Please, Measure in an environment free from vibration.
•Shock or disassembly will cause the equipment to malfunction and will not
be included in the warranty. (the unit will display “ERR” message)
•Abnormal data can be measured when using near a strong electromagnetic
radiation source such as high voltage transmission line, subway line, Wifi
transmitter(1Meter or less), microwave oven(1M or less) ('OVER'
message)
•Use only indoors. No waterproof.
•Use the provided DC 12V adapter.
•Continuous use in an environment with relative humidity of 80% or
higher is prohibited.
•A warning message may be sent to the set mobile device when it is higher
than the set radon concentration.
•Proper operating temperature range is 10℃ ~ 40℃ (50°F ~ 100°F)
•The warranty period is one year after purchase.
<Radon concentration fluctuation graph>
Seasonal radon concentration
WinterAutumnSummerSpring
Daily radon concentration
Day Evening Day
Dawn
Precautions when using
Example of proper installation
· please, let the device where there is no ventilation
environment to check the area's usual radon status.
Prohibited
· Install at least 50cm apart from wall, window and floor.
· In general, proper places to install are on desk, table
in the living room, or on dining table in the kitchen.
Caution
1. For accurate measurement, close windows and doors tightly.
2. When RadonEye + is connected to DC 12V adaptor, measurement
starts automatically.
3. After the power is on, the wait time (10 minutes) is indicated by ‘- -’.
When wait time is over, the measured values are displayed from
10 minutes later. Measurements are displayed in 10 minute interval,
and saved in 1 hour interval.
To start the device
RADONEYE +
C_device
P_device
Measured value
12h 24h36h
Actual value
1h
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Precautions before using App.
This is the User's Manual for controlling RadonEye + device made in
Radon FTLab. Please refer to the detailed manual on the Radon FTLab
website (http://RadonFTLab.com) for the equipment and PC program
manual.
• Since it is an application that operates on a Wi-Fi base, there may be
operational limitations.
• It works properly in Android 4.3 version or iOS 8.0 version or later
• If the distance between the device and the smart device increases,
the
connection may be lost.
• In the 5G Internet environment, there are restrictions in the use of the
product, so please use 2.4G.
• We recommend user to agree to the privacy policy during the app
setting stage for trouble-free data transfer.
• Bluetooth and GPS must be enabled before using
• The time in the area where the equipment is installed is applied to the
data recorded after app setting/direct connection. The factory
Bluetooth & GPS function of
mobile device should be
activated for
RadonEye + setting
GPS
Bluetooth
RadonEye +
RadonEye + is the world's first IoT smart radon detector that is used in connec-
tion with web database based on WiFi. Therefore, RadonEye + is suitable for
real-time radon monitoring and easy to create Real-Time Radon Map. Manufac-
turer, Radon FTLab provides web database, radon-net.com, which means the
user can access the data every time, everywhere by smart phone, tablet or
internet connected desktop PC.
The sensitivity performance of RadonEye + is like a standard instrument. It is 20
times higher when it is compared with other general customer’s radon detector,
so the measurement data is fast and precise. Radon measurement data can be
recorded within 1 hour with below
±
10% error from starting time of measurement
and the data will be updated every 10 minutes so the user will get to know the
diminishing trend of indoor radon level just within 30 minutes by ventilation or
window open.
RadonEye + has added temperature & humidity sensor and measurement time
recording and extended the measurement range to 255pCi / l.
RadonEye + offers free web uploading service at least 2 years.
Measurement
Range
Precision
Accuracy
Data log
Display
Mobile control
Sensing factor
Time checking
Web access
Mobile notification
WiFi, Bluetooth
Radon,Humidity,Temperature
O
O
O
0.1~255 pCi/l
(1 ~9,435 Bq/㎥)
Model RadonEye (RD200) RadonEye + (RD200P2)
Bluetooth
Radon
X
X
X
0.1~100 pCi/l
(1 ~3,700 Bq/㎥)
< ±10%at 10pCi/l (370Bq/㎥)
< ±10%(min. error <±0.5pCi/l)
max1year(1hour interval)
0.96 inch OLED
< RadonEye VS RadonEye + >
1. What should I do under condition of no Wi-Fi around available?
A : RadonEye Plus2 automatically starts measuring when power is simply connected, so all you need to do is just select 'Connected Devices'
menu in your smartphone application even if you don't have a Wi-Fi
2. Tell me how to set up an app. when errors.
2.1. RadonEye Plus2 you are trying to set is not on the list.
A (iPhone) : Switch Bluetooth off and on to update the list again.
A (Android) : Click the "Rescan" button to update the list again.
2.2. The Wi-Fi list displayed on the app. does not contain the desired Wi-Fi I’d like to connect to.
A : Click the ‘refresh’ icon to update the Wi-Fi list. for your reference, 5GHz Wi-Fi is not supported and will not appear in the list.
2.3. If 'Wi-Fi settings failed' is displayed when next button is clicked after entering the Wi-Fi information.
A : If the green LED on RadonEye Plus2 keeps blinking and Wi-Fi connection is not successful, please check if Wi-Fi password is entered
correctly and internet connection status of the Router.
2.4. If the message 'RadonEye Plus2 registration failed' is displayed when the button is clicked after entering the Wi-Fi information,
A : Smartphone should also be Internet-connected through Wi-Fi / LTE / 3G
Check the Internet connection status of the smart device and proceed with setting under this circumstance.
2.5. If other cases of setting failure
A : Check the Wi-Fi and GPS connection on your smartphone, then turn the device off and on and run.
3. How can I change RadonEye Plus2 wifi connection that’s been already set into previous wifi place?
A : If you have Wi-Fi in your environment, you can set it up again and use it easily by clicking ‘Main’-‘Sub Menu’-‘Network’
4. It continues to show the high concentration figure, Is it out of order?
A : In this case, leave it in a well ventilated location for about two days and try to measure the low concentration at veranda, indoor air quality,
and high concentration in sequence
Q&A
RADON NET
RadonEye + provides Remote Radon Monitoring Network Service. You can
check radon value in the web browser by registering the registration key which
is given when you access the radon-net.com website when setting the app.
You can also check the local radon value at any time through Radon Map.
· My Devices
· Information
· Device Location
· Device Log (Graph)
· Radon Map
Sign In
Guest
Email
RADON NET
Password
Good
Normal
Warning
Bad
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
Smart Radon Gas Monitor
RADONEYE +
Operation Manual
RD200P2
•Type : pulsed ion chamber
•First reliable data out : < 60min
•Data interval : 10min update (60min moving average)
•Sensitivity : 0.5cpm/pCi/l at 10pCi/l (30cph/pCi/l)
•Operating range : 10℃ ~ 40℃ (50°F ~ 100°F), RH < 80%
•Measurement range : 0.1 ~ 255 pCi/l (9,435 Bq/㎥)
* Environment reference value 4pCi/l (148 Bq/㎥)
•Precision : < ±10% at 10pCi/l
•Accuracy : < ±10% (min. error <±0.5pCi/l ) at 10pCi/l
•Interval of measurement value saving : 60 minutes
•Storage capacity : 1 year
•Power consumption : DC12 ± 0.1V, 0.1A ( Use 12V DC adapter)
•Size : Φ80(mm) x 120(mm)
•Display : 0.96 inch OLED
•Data communication : Wi-Fi (internet), Bluetooth
•Weight : 520g
•Altitude : Up to 2000 m
•pollution degree : 2
* Radon Eye Plus 2 is a function upgraded version of Radon Eye Plus that enhances
Wi-Fi setup convenience by adding BLE communication to previous Radon Eye Plus
products.
* In March 2019, the model name of RadonEye Plus2 changes from RD200P to
RD200P2.
Product Specifications
Descriptive labeling in accordance with Quality
Management and Safety Control Act for Industrial Goods.
Instrument type: RD200P2
Instrument name : RADONEYE +
Kind : For home(indoor) use
Material : ABS
Manufactured date : Indicated separately
Manufacturer : FTLab
* Only the manufacturer or agency will inspect and supply
Country of manufacture : Republic of Korea
Questions : www.radonftlab.com
FTLAB succeeded in developing a real-time Radon
sensor in 2015, and also succeeded in mass production
in 2016, we launched RADON FTLAB.
COPYRIGHT (C)FTLAB Co., Ltd ALL RIGHT RESREVED.
503ho, 8, 330beon-gil,
Haebong-ro, Danwon-gu,
Ansan-si, Gyeonggi-do, Korea
FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
① BLE access : Indicates it is connected with smartphone using BLE communication
② Shock detect sign : It appears when a shock or vibration from outside is sensed, and
the measurement stops at the time
③ Radon concentration : Measured value of Radon shown in 10 minute interval
④ Unit of measure : Shown in pCi/l or Bq/㎥. Unit can be changed by smartphone app.
⑤ Information display : SN, peak value, 1/2/7 day and month average, measurement time,
pulse count per 10 minute measurement (present value/last value)
Name and function of each part
BLE Access
Shock detection
Radon concentration
Unit
Information
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Name and function of each part
Front
LED : Red LED flashes for 30 seconds when Radon value exceeds
reference value.
Green LED flashes when Wi-Fi connection is not normal.
Ventilation window
LCD : Information display window for Wi-Fi access, shock detection,
Radon concentration, etc.
Rear
Power
12V DC
Radon ?
1. Radon is a colorless, odorless and tasteless radioactive gas.
Radon, a gas originating from radium which is generated by the collapse of
uranium in soil, is everywhere on earth. It penetrates indoors mainly from the
ground or building materials. The gases that cause sick house syndrome and
other noxious gases luckily smell. Urban gas and LPG were deliberately
smelled. However, radon does not smell nor can be seen. And no matter how
many years have passed, it is constantly released from the wall, ceiling and
floor.
2. Radon is 8 times heavier than air and is easily concentrated in the house.
Radon has the half-life of 3.8 days and makes alpha decay. The alpha particle
emitted from radon has the smallest penetration power among the radiation
rays and can not penetrate even a single piece of paper, but its destructive
power is so great that the cells are damaged if they are directly impacted by
radon, even having a nickname of "silent murderer". This is why radon detec-
tion sensor is absolutely needed in home.
3. Radon gas causes lung cancer.
Three causes of modern female lung cancer are passive smoking, ultrafine
particles and radon. When radon gas enters the lung through breathing, alpha
particles released from radon damage the lung cells. Since once destroyed
lung cells are not regenerated, prolonged exposure to high concentration of
radon gas will increase the likelihood of lung cancer. Therefore, the United
States Environmental Protection Agency(EPA) designated Radon as a must
be managed hazardous gas for healthy life.
- Accurate measurement value of the average radon level can be obtained when
the house is empty for 1 or 2 days.
- Reliable value can be obtained about 1 hour after start of the measurement.
- Radon concentration in the house is generally high at dawn and low at daytime,
so continuous measurement for more than 24 hours is necessary.
Precautions
•Please, Measure in an environment free from vibration.
•Shock or disassembly will cause the equipment to malfunction and will not
be included in the warranty. (the unit will display “ERR” message)
•Abnormal data can be measured when using near a strong electromagnetic
radiation source such as high voltage transmission line, subway line, Wifi
transmitter(1Meter or less), microwave oven(1M or less) ('OVER'
message)
•Use only indoors. No waterproof.
•Use the provided DC 12V adapter.
•Continuous use in an environment with relative humidity of 80% or
higher is prohibited.
•A warning message may be sent to the set mobile device when it is higher
than the set radon concentration.
•Proper operating temperature range is 10℃ ~ 40℃ (50°F ~ 100°F)
•The warranty period is one year after purchase.
<Radon concentration fluctuation graph>
Seasonal radon concentration
WinterAutumnSummerSpring
Daily radon concentration
Day Evening Day
Dawn
Precautions when using
Example of proper installation
· please, let the device where there is no ventilation
environment to check the area's usual radon status.
Prohibited
· Install at least 50cm apart from wall, window and floor.
· In general, proper places to install are on desk, table
in the living room, or on dining table in the kitchen.
Caution
1. For accurate measurement, close windows and doors tightly.
2. When RadonEye + is connected to DC 12V adaptor, measurement
starts automatically.
3. After the power is on, the wait time (10 minutes) is indicated by ‘- -’.
When wait time is over, the measured values are displayed from
10 minutes later. Measurements are displayed in 10 minute interval,
and saved in 1 hour interval.
To start the device
RADONEYE +
C_device
P_device
Measured value
12h 24h36h
Actual value
1h
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Precautions before using App.
This is the User's Manual for controlling RadonEye + device made in
Radon FTLab. Please refer to the detailed manual on the Radon FTLab
website (http://RadonFTLab.com) for the equipment and PC program
manual.
• Since it is an application that operates on a Wi-Fi base, there may be
operational limitations.
• It works properly in Android 4.3 version or iOS 8.0 version or later
• If the distance between the device and the smart device increases,
the
connection may be lost.
• In the 5G Internet environment, there are restrictions in the use of the
product, so please use 2.4G.
• We recommend user to agree to the privacy policy during the app
setting stage for trouble-free data transfer.
• Bluetooth and GPS must be enabled before using
• The time in the area where the equipment is installed is applied to the
data recorded after app setting/direct connection. The factory
Bluetooth & GPS function of
mobile device should be
activated for
RadonEye + setting
GPS
Bluetooth
RadonEye +
RadonEye + is the world's first IoT smart radon detector that is used in connec-
tion with web database based on WiFi. Therefore, RadonEye + is suitable for
real-time radon monitoring and easy to create Real-Time Radon Map. Manufac-
turer, Radon FTLab provides web database, radon-net.com, which means the
user can access the data every time, everywhere by smart phone, tablet or
internet connected desktop PC.
The sensitivity performance of RadonEye + is like a standard instrument. It is 20
times higher when it is compared with other general customer’s radon detector,
so the measurement data is fast and precise. Radon measurement data can be
recorded within 1 hour with below
±
10% error from starting time of measurement
and the data will be updated every 10 minutes so the user will get to know the
diminishing trend of indoor radon level just within 30 minutes by ventilation or
window open.
RadonEye + has added temperature & humidity sensor and measurement time
recording and extended the measurement range to 255pCi / l.
RadonEye + offers free web uploading service at least 2 years.
Measurement
Range
Precision
Accuracy
Data log
Display
Mobile control
Sensing factor
Time checking
Web access
Mobile notification
WiFi, Bluetooth
Radon,Humidity,Temperature
O
O
O
0.1~255 pCi/l
(1 ~9,435 Bq/㎥)
Model RadonEye (RD200) RadonEye + (RD200P2)
Bluetooth
Radon
X
X
X
0.1~100 pCi/l
(1 ~3,700 Bq/㎥)
< ±10%at 10pCi/l (370Bq/㎥)
< ±10%(min. error <±0.5pCi/l)
max1year(1hour interval)
0.96 inch OLED
< RadonEye VS RadonEye + >
1. What should I do under condition of no Wi-Fi around available?
A : RadonEye Plus2 automatically starts measuring when power is simply connected, so all you need to do is just select 'Connected Devices'
menu in your smartphone application even if you don't have a Wi-Fi
2. Tell me how to set up an app. when errors.
2.1. RadonEye Plus2 you are trying to set is not on the list.
A (iPhone) : Switch Bluetooth off and on to update the list again.
A (Android) : Click the "Rescan" button to update the list again.
2.2. The Wi-Fi list displayed on the app. does not contain the desired Wi-Fi I’d like to connect to.
A : Click the ‘refresh’ icon to update the Wi-Fi list. for your reference, 5GHz Wi-Fi is not supported and will not appear in the list.
2.3. If 'Wi-Fi settings failed' is displayed when next button is clicked after entering the Wi-Fi information.
A : If the green LED on RadonEye Plus2 keeps blinking and Wi-Fi connection is not successful, please check if Wi-Fi password is entered
correctly and internet connection status of the Router.
2.4. If the message 'RadonEye Plus2 registration failed' is displayed when the button is clicked after entering the Wi-Fi information,
A : Smartphone should also be Internet-connected through Wi-Fi / LTE / 3G
Check the Internet connection status of the smart device and proceed with setting under this circumstance.
2.5. If other cases of setting failure
A : Check the Wi-Fi and GPS connection on your smartphone, then turn the device off and on and run.
3. How can I change RadonEye Plus2 wifi connection that’s been already set into previous wifi place?
A : If you have Wi-Fi in your environment, you can set it up again and use it easily by clicking ‘Main’-‘Sub Menu’-‘Network’
4. It continues to show the high concentration figure, Is it out of order?
A : In this case, leave it in a well ventilated location for about two days and try to measure the low concentration at veranda, indoor air quality,
and high concentration in sequence
Q&A
RADON NET
RadonEye + provides Remote Radon Monitoring Network Service. You can
check radon value in the web browser by registering the registration key which
is given when you access the radon-net.com website when setting the app.
You can also check the local radon value at any time through Radon Map.
· My Devices
· Information
· Device Location
· Device Log (Graph)
· Radon Map
Sign In
Guest
Email
RADON NET
Password
Good
Normal
Warning
Bad
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
Smart Radon Gas Monitor
RADONEYE +
Operation Manual
RD200P2
•Type : pulsed ion chamber
•First reliable data out : < 60min
•Data interval : 10min update (60min moving average)
•Sensitivity : 0.5cpm/pCi/l at 10pCi/l (30cph/pCi/l)
•Operating range : 10℃ ~ 40℃ (50°F ~ 100°F), RH < 80%
•Measurement range : 0.1 ~ 255 pCi/l (9,435 Bq/㎥)
* Environment reference value 4pCi/l (148 Bq/㎥)
•Precision : < ±10% at 10pCi/l
•Accuracy : < ±10% (min. error <±0.5pCi/l ) at 10pCi/l
•Interval of measurement value saving : 60 minutes
•Storage capacity : 1 year
•Power consumption : DC12 ± 0.1V, 0.1A ( Use 12V DC adapter)
•Size : Φ80(mm) x 120(mm)
•Display : 0.96 inch OLED
•Data communication : Wi-Fi (internet), Bluetooth
•Weight : 520g
•Altitude : Up to 2000 m
•pollution degree : 2
* Radon Eye Plus 2 is a function upgraded version of Radon Eye Plus that enhances
Wi-Fi setup convenience by adding BLE communication to previous Radon Eye Plus
products.
* In March 2019, the model name of RadonEye Plus2 changes from RD200P to
RD200P2.
Product Specifications
Descriptive labeling in accordance with Quality
Management and Safety Control Act for Industrial Goods.
Instrument type: RD200P2
Instrument name : RADONEYE +
Kind : For home(indoor) use
Material : ABS
Manufactured date : Indicated separately
Manufacturer : FTLab
* Only the manufacturer or agency will inspect and supply
Country of manufacture : Republic of Korea
Questions : www.radonftlab.com
FTLAB succeeded in developing a real-time Radon
sensor in 2015, and also succeeded in mass production
in 2016, we launched RADON FTLAB.
COPYRIGHT (C)FTLAB Co., Ltd ALL RIGHT RESREVED.
503ho, 8, 330beon-gil,
Haebong-ro, Danwon-gu,
Ansan-si, Gyeonggi-do, Korea
FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
① BLE access : Indicates it is connected with smartphone using BLE communication
② Shock detect sign : It appears when a shock or vibration from outside is sensed, and
the measurement stops at the time
③ Radon concentration : Measured value of Radon shown in 10 minute interval
④ Unit of measure : Shown in pCi/l or Bq/㎥. Unit can be changed by smartphone app.
⑤ Information display : SN, peak value, 1/2/7 day and month average, measurement time,
pulse count per 10 minute measurement (present value/last value)
Name and function of each part
BLE Access
Shock detection
Radon concentration
Unit
Information
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Name and function of each part
Front
LED : Red LED flashes for 30 seconds when Radon value exceeds
reference value.
Green LED flashes when Wi-Fi connection is not normal.
Ventilation window
LCD : Information display window for Wi-Fi access, shock detection,
Radon concentration, etc.
Rear
Power
12V DC
Radon ?
1. Radon is a colorless, odorless and tasteless radioactive gas.
Radon, a gas originating from radium which is generated by the collapse of
uranium in soil, is everywhere on earth. It penetrates indoors mainly from the
ground or building materials. The gases that cause sick house syndrome and
other noxious gases luckily smell. Urban gas and LPG were deliberately
smelled. However, radon does not smell nor can be seen. And no matter how
many years have passed, it is constantly released from the wall, ceiling and
floor.
2. Radon is 8 times heavier than air and is easily concentrated in the house.
Radon has the half-life of 3.8 days and makes alpha decay. The alpha particle
emitted from radon has the smallest penetration power among the radiation
rays and can not penetrate even a single piece of paper, but its destructive
power is so great that the cells are damaged if they are directly impacted by
radon, even having a nickname of "silent murderer". This is why radon detec-
tion sensor is absolutely needed in home.
3. Radon gas causes lung cancer.
Three causes of modern female lung cancer are passive smoking, ultrafine
particles and radon. When radon gas enters the lung through breathing, alpha
particles released from radon damage the lung cells. Since once destroyed
lung cells are not regenerated, prolonged exposure to high concentration of
radon gas will increase the likelihood of lung cancer. Therefore, the United
States Environmental Protection Agency(EPA) designated Radon as a must
be managed hazardous gas for healthy life.
- Accurate measurement value of the average radon level can be obtained when
the house is empty for 1 or 2 days.
- Reliable value can be obtained about 1 hour after start of the measurement.
- Radon concentration in the house is generally high at dawn and low at daytime,
so continuous measurement for more than 24 hours is necessary.
Precautions
•Please, Measure in an environment free from vibration.
•Shock or disassembly will cause the equipment to malfunction and will not
be included in the warranty. (the unit will display “ERR” message)
•Abnormal data can be measured when using near a strong electromagnetic
radiation source such as high voltage transmission line, subway line, Wifi
transmitter(1Meter or less), microwave oven(1M or less) ('OVER'
message)
•Use only indoors. No waterproof.
•Use the provided DC 12V adapter.
•Continuous use in an environment with relative humidity of 80% or
higher is prohibited.
•A warning message may be sent to the set mobile device when it is higher
than the set radon concentration.
•Proper operating temperature range is 10℃ ~ 40℃ (50°F ~ 100°F)
•The warranty period is one year after purchase.
<Radon concentration fluctuation graph>
Seasonal radon concentration
WinterAutumnSummerSpring
Daily radon concentration
Day Evening Day
Dawn
Precautions when using
Example of proper installation
· please, let the device where there is no ventilation
environment to check the area's usual radon status.
Prohibited
· Install at least 50cm apart from wall, window and floor.
· In general, proper places to install are on desk, table
in the living room, or on dining table in the kitchen.
Caution
1. For accurate measurement, close windows and doors tightly.
2. When RadonEye + is connected to DC 12V adaptor, measurement
starts automatically.
3. After the power is on, the wait time (10 minutes) is indicated by ‘- -’.
When wait time is over, the measured values are displayed from
10 minutes later. Measurements are displayed in 10 minute interval,
and saved in 1 hour interval.
To start the device
RADONEYE +
C_device
P_device
Measured value
12h 24h36h
Actual value
1h
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Precautions before using App.
This is the User's Manual for controlling RadonEye + device made in
Radon FTLab. Please refer to the detailed manual on the Radon FTLab
website (http://RadonFTLab.com) for the equipment and PC program
manual.
• Since it is an application that operates on a Wi-Fi base, there may be
operational limitations.
• It works properly in Android 4.3 version or iOS 8.0 version or later
• If the distance between the device and the smart device increases,
the
connection may be lost.
• In the 5G Internet environment, there are restrictions in the use of the
product, so please use 2.4G.
• We recommend user to agree to the privacy policy during the app
setting stage for trouble-free data transfer.
• Bluetooth and GPS must be enabled before using
• The time in the area where the equipment is installed is applied to the
data recorded after app setting/direct connection. The factory
Bluetooth & GPS function of
mobile device should be
activated for
RadonEye + setting
GPS
Bluetooth
RadonEye +
RadonEye + is the world's first IoT smart radon detector that is used in connec-
tion with web database based on WiFi. Therefore, RadonEye + is suitable for
real-time radon monitoring and easy to create Real-Time Radon Map. Manufac-
turer, Radon FTLab provides web database, radon-net.com, which means the
user can access the data every time, everywhere by smart phone, tablet or
internet connected desktop PC.
The sensitivity performance of RadonEye + is like a standard instrument. It is 20
times higher when it is compared with other general customer’s radon detector,
so the measurement data is fast and precise. Radon measurement data can be
recorded within 1 hour with below
±
10% error from starting time of measurement
and the data will be updated every 10 minutes so the user will get to know the
diminishing trend of indoor radon level just within 30 minutes by ventilation or
window open.
RadonEye + has added temperature & humidity sensor and measurement time
recording and extended the measurement range to 255pCi / l.
RadonEye + offers free web uploading service at least 2 years.
Measurement
Range
Precision
Accuracy
Data log
Display
Mobile control
Sensing factor
Time checking
Web access
Mobile notification
WiFi, Bluetooth
Radon,Humidity,Temperature
O
O
O
0.1~255 pCi/l
(1 ~9,435 Bq/㎥)
Model RadonEye (RD200) RadonEye + (RD200P2)
Bluetooth
Radon
X
X
X
0.1~100 pCi/l
(1 ~3,700 Bq/㎥)
< ±10%at 10pCi/l (370Bq/㎥)
< ±10%(min. error <±0.5pCi/l)
max1year(1hour interval)
0.96 inch OLED
< RadonEye VS RadonEye + >
1. What should I do under condition of no Wi-Fi around available?
A : RadonEye Plus2 automatically starts measuring when power is simply connected, so all you need to do is just select 'Connected Devices'
menu in your smartphone application even if you don't have a Wi-Fi
2. Tell me how to set up an app. when errors.
2.1. RadonEye Plus2 you are trying to set is not on the list.
A (iPhone) : Switch Bluetooth off and on to update the list again.
A (Android) : Click the "Rescan" button to update the list again.
2.2. The Wi-Fi list displayed on the app. does not contain the desired Wi-Fi I’d like to connect to.
A : Click the ‘refresh’ icon to update the Wi-Fi list. for your reference, 5GHz Wi-Fi is not supported and will not appear in the list.
2.3. If 'Wi-Fi settings failed' is displayed when next button is clicked after entering the Wi-Fi information.
A : If the green LED on RadonEye Plus2 keeps blinking and Wi-Fi connection is not successful, please check if Wi-Fi password is entered
correctly and internet connection status of the Router.
2.4. If the message 'RadonEye Plus2 registration failed' is displayed when the button is clicked after entering the Wi-Fi information,
A : Smartphone should also be Internet-connected through Wi-Fi / LTE / 3G
Check the Internet connection status of the smart device and proceed with setting under this circumstance.
2.5. If other cases of setting failure
A : Check the Wi-Fi and GPS connection on your smartphone, then turn the device off and on and run.
3. How can I change RadonEye Plus2 wifi connection that’s been already set into previous wifi place?
A : If you have Wi-Fi in your environment, you can set it up again and use it easily by clicking ‘Main’-‘Sub Menu’-‘Network’
4. It continues to show the high concentration figure, Is it out of order?
A : In this case, leave it in a well ventilated location for about two days and try to measure the low concentration at veranda, indoor air quality,
and high concentration in sequence
Q&A
RADON NET
RadonEye + provides Remote Radon Monitoring Network Service. You can
check radon value in the web browser by registering the registration key which
is given when you access the radon-net.com website when setting the app.
You can also check the local radon value at any time through Radon Map.
· My Devices
· Information
· Device Location
· Device Log (Graph)
· Radon Map
Sign In
Guest
Email
RADON NET
Password
Good
Normal
Warning
Bad
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
Smart Radon Gas Monitor
RADONEYE +
Operation Manual
RD200P2
•Type : pulsed ion chamber
•First reliable data out : < 60min
•Data interval : 10min update (60min moving average)
•Sensitivity : 0.5cpm/pCi/l at 10pCi/l (30cph/pCi/l)
•Operating range : 10℃ ~ 40℃ (50°F ~ 100°F), RH < 80%
•Measurement range : 0.1 ~ 255 pCi/l (9,435 Bq/㎥)
* Environment reference value 4pCi/l (148 Bq/㎥)
•Precision : < ±10% at 10pCi/l
•Accuracy : < ±10% (min. error <±0.5pCi/l ) at 10pCi/l
•Interval of measurement value saving : 60 minutes
•Storage capacity : 1 year
•Power consumption : DC12 ± 0.1V, 0.1A ( Use 12V DC adapter)
•Size : Φ80(mm) x 120(mm)
•Display : 0.96 inch OLED
•Data communication : Wi-Fi (internet), Bluetooth
•Weight : 520g
•Altitude : Up to 2000 m
•pollution degree : 2
* Radon Eye Plus 2 is a function upgraded version of Radon Eye Plus that enhances
Wi-Fi setup convenience by adding BLE communication to previous Radon Eye Plus
products.
* In March 2019, the model name of RadonEye Plus2 changes from RD200P to
RD200P2.
Product Specifications
Descriptive labeling in accordance with Quality
Management and Safety Control Act for Industrial Goods.
Instrument type: RD200P2
Instrument name : RADONEYE +
Kind : For home(indoor) use
Material : ABS
Manufactured date : Indicated separately
Manufacturer : FTLab
* Only the manufacturer or agency will inspect and supply
Country of manufacture : Republic of Korea
Questions : www.radonftlab.com
FTLAB succeeded in developing a real-time Radon
sensor in 2015, and also succeeded in mass production
in 2016, we launched RADON FTLAB.
COPYRIGHT (C)FTLAB Co., Ltd ALL RIGHT RESREVED.
503ho, 8, 330beon-gil,
Haebong-ro, Danwon-gu,
Ansan-si, Gyeonggi-do, Korea
FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
① BLE access : Indicates it is connected with smartphone using BLE communication
② Shock detect sign : It appears when a shock or vibration from outside is sensed, and
the measurement stops at the time
③ Radon concentration : Measured value of Radon shown in 10 minute interval
④ Unit of measure : Shown in pCi/l or Bq/㎥. Unit can be changed by smartphone app.
⑤ Information display : SN, peak value, 1/2/7 day and month average, measurement time,
pulse count per 10 minute measurement (present value/last value)
Name and function of each part
BLE Access
Shock detection
Radon concentration
Unit
Information
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Name and function of each part
Front
LED : Red LED flashes for 30 seconds when Radon value exceeds
reference value.
Green LED flashes when Wi-Fi connection is not normal.
Ventilation window
LCD : Information display window for Wi-Fi access, shock detection,
Radon concentration, etc.
Rear
Power
12V DC
Radon ?
1. Radon is a colorless, odorless and tasteless radioactive gas.
Radon, a gas originating from radium which is generated by the collapse of
uranium in soil, is everywhere on earth. It penetrates indoors mainly from the
ground or building materials. The gases that cause sick house syndrome and
other noxious gases luckily smell. Urban gas and LPG were deliberately
smelled. However, radon does not smell nor can be seen. And no matter how
many years have passed, it is constantly released from the wall, ceiling and
floor.
2. Radon is 8 times heavier than air and is easily concentrated in the house.
Radon has the half-life of 3.8 days and makes alpha decay. The alpha particle
emitted from radon has the smallest penetration power among the radiation
rays and can not penetrate even a single piece of paper, but its destructive
power is so great that the cells are damaged if they are directly impacted by
radon, even having a nickname of "silent murderer". This is why radon detec-
tion sensor is absolutely needed in home.
3. Radon gas causes lung cancer.
Three causes of modern female lung cancer are passive smoking, ultrafine
particles and radon. When radon gas enters the lung through breathing, alpha
particles released from radon damage the lung cells. Since once destroyed
lung cells are not regenerated, prolonged exposure to high concentration of
radon gas will increase the likelihood of lung cancer. Therefore, the United
States Environmental Protection Agency(EPA) designated Radon as a must
be managed hazardous gas for healthy life.
- Accurate measurement value of the average radon level can be obtained when
the house is empty for 1 or 2 days.
- Reliable value can be obtained about 1 hour after start of the measurement.
- Radon concentration in the house is generally high at dawn and low at daytime,
so continuous measurement for more than 24 hours is necessary.
Precautions
•Please, Measure in an environment free from vibration.
•Shock or disassembly will cause the equipment to malfunction and will not
be included in the warranty. (the unit will display “ERR” message)
•Abnormal data can be measured when using near a strong electromagnetic
radiation source such as high voltage transmission line, subway line, Wifi
transmitter(1Meter or less), microwave oven(1M or less) ('OVER'
message)
•Use only indoors. No waterproof.
•Use the provided DC 12V adapter.
•Continuous use in an environment with relative humidity of 80% or
higher is prohibited.
•A warning message may be sent to the set mobile device when it is higher
than the set radon concentration.
•Proper operating temperature range is 10℃ ~ 40℃ (50°F ~ 100°F)
•The warranty period is one year after purchase.
<Radon concentration fluctuation graph>
Seasonal radon concentration
WinterAutumnSummerSpring
Daily radon concentration
Day Evening Day
Dawn
Precautions when using
Example of proper installation
· please, let the device where there is no ventilation
environment to check the area's usual radon status.
Prohibited
· Install at least 50cm apart from wall, window and floor.
· In general, proper places to install are on desk, table
in the living room, or on dining table in the kitchen.
Caution
1. For accurate measurement, close windows and doors tightly.
2. When RadonEye + is connected to DC 12V adaptor, measurement
starts automatically.
3. After the power is on, the wait time (10 minutes) is indicated by ‘- -’.
When wait time is over, the measured values are displayed from
10 minutes later. Measurements are displayed in 10 minute interval,
and saved in 1 hour interval.
To start the device
RADONEYE +
C_device
P_device
Measured value
12h 24h36h
Actual value
1h
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Precautions before using App.
This is the User's Manual for controlling RadonEye + device made in
Radon FTLab. Please refer to the detailed manual on the Radon FTLab
website (http://RadonFTLab.com) for the equipment and PC program
manual.
• Since it is an application that operates on a Wi-Fi base, there may be
operational limitations.
• It works properly in Android 4.3 version or iOS 8.0 version or later
• If the distance between the device and the smart device increases,
the
connection may be lost.
• In the 5G Internet environment, there are restrictions in the use of the
product, so please use 2.4G.
• We recommend user to agree to the privacy policy during the app
setting stage for trouble-free data transfer.
• Bluetooth and GPS must be enabled before using
• The time in the area where the equipment is installed is applied to the
data recorded after app setting/direct connection. The factory
Bluetooth & GPS function of
mobile device should be
activated for
RadonEye + setting
GPS
Bluetooth
RadonEye +
RadonEye + is the world's first IoT smart radon detector that is used in connec-
tion with web database based on WiFi. Therefore, RadonEye + is suitable for
real-time radon monitoring and easy to create Real-Time Radon Map. Manufac-
turer, Radon FTLab provides web database, radon-net.com, which means the
user can access the data every time, everywhere by smart phone, tablet or
internet connected desktop PC.
The sensitivity performance of RadonEye + is like a standard instrument. It is 20
times higher when it is compared with other general customer’s radon detector,
so the measurement data is fast and precise. Radon measurement data can be
recorded within 1 hour with below
±
10% error from starting time of measurement
and the data will be updated every 10 minutes so the user will get to know the
diminishing trend of indoor radon level just within 30 minutes by ventilation or
window open.
RadonEye + has added temperature & humidity sensor and measurement time
recording and extended the measurement range to 255pCi / l.
RadonEye + offers free web uploading service at least 2 years.
Measurement
Range
Precision
Accuracy
Data log
Display
Mobile control
Sensing factor
Time checking
Web access
Mobile notification
WiFi, Bluetooth
Radon,Humidity,Temperature
O
O
O
0.1~255 pCi/l
(1 ~9,435 Bq/㎥)
Model RadonEye (RD200) RadonEye + (RD200P2)
Bluetooth
Radon
X
X
X
0.1~100 pCi/l
(1 ~3,700 Bq/㎥)
< ±10%at 10pCi/l (370Bq/㎥)
< ±10%(min. error <±0.5pCi/l)
max1year(1hour interval)
0.96 inch OLED
< RadonEye VS RadonEye + >
1. What should I do under condition of no Wi-Fi around available?
A : RadonEye Plus2 automatically starts measuring when power is simply connected, so all you need to do is just select 'Connected Devices'
menu in your smartphone application even if you don't have a Wi-Fi
2. Tell me how to set up an app. when errors.
2.1. RadonEye Plus2 you are trying to set is not on the list.
A (iPhone) : Switch Bluetooth off and on to update the list again.
A (Android) : Click the "Rescan" button to update the list again.
2.2. The Wi-Fi list displayed on the app. does not contain the desired Wi-Fi I’d like to connect to.
A : Click the ‘refresh’ icon to update the Wi-Fi list. for your reference, 5GHz Wi-Fi is not supported and will not appear in the list.
2.3. If 'Wi-Fi settings failed' is displayed when next button is clicked after entering the Wi-Fi information.
A : If the green LED on RadonEye Plus2 keeps blinking and Wi-Fi connection is not successful, please check if Wi-Fi password is entered
correctly and internet connection status of the Router.
2.4. If the message 'RadonEye Plus2 registration failed' is displayed when the button is clicked after entering the Wi-Fi information,
A : Smartphone should also be Internet-connected through Wi-Fi / LTE / 3G
Check the Internet connection status of the smart device and proceed with setting under this circumstance.
2.5. If other cases of setting failure
A : Check the Wi-Fi and GPS connection on your smartphone, then turn the device off and on and run.
3. How can I change RadonEye Plus2 wifi connection that’s been already set into previous wifi place?
A : If you have Wi-Fi in your environment, you can set it up again and use it easily by clicking ‘Main’-‘Sub Menu’-‘Network’
4. It continues to show the high concentration figure, Is it out of order?
A : In this case, leave it in a well ventilated location for about two days and try to measure the low concentration at veranda, indoor air quality,
and high concentration in sequence
Q&A
RADON NET
RadonEye + provides Remote Radon Monitoring Network Service. You can
check radon value in the web browser by registering the registration key which
is given when you access the radon-net.com website when setting the app.
You can also check the local radon value at any time through Radon Map.
· My Devices
· Information
· Device Location
· Device Log (Graph)
· Radon Map
Sign In
Guest
Email
RADON NET
Password
Good
Normal
Warning
Bad
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
Smart Radon Gas Monitor
RADONEYE +
Operation Manual
RD200P2
•Type : pulsed ion chamber
•First reliable data out : < 60min
•Data interval : 10min update (60min moving average)
•Sensitivity : 0.5cpm/pCi/l at 10pCi/l (30cph/pCi/l)
•Operating range : 10℃ ~ 40℃ (50°F ~ 100°F), RH < 80%
•Measurement range : 0.1 ~ 255 pCi/l (9,435 Bq/㎥)
* Environment reference value 4pCi/l (148 Bq/㎥)
•Precision : < ±10% at 10pCi/l
•Accuracy : < ±10% (min. error <±0.5pCi/l ) at 10pCi/l
•Interval of measurement value saving : 60 minutes
•Storage capacity : 1 year
•Power consumption : DC12 ± 0.1V, 0.1A ( Use 12V DC adapter)
•Size : Φ80(mm) x 120(mm)
•Display : 0.96 inch OLED
•Data communication : Wi-Fi (internet), Bluetooth
•Weight : 520g
•Altitude : Up to 2000 m
•pollution degree : 2
* Radon Eye Plus 2 is a function upgraded version of Radon Eye Plus that enhances
Wi-Fi setup convenience by adding BLE communication to previous Radon Eye Plus
products.
* In March 2019, the model name of RadonEye Plus2 changes from RD200P to
RD200P2.
Product Specifications
Descriptive labeling in accordance with Quality
Management and Safety Control Act for Industrial Goods.
Instrument type: RD200P2
Instrument name : RADONEYE +
Kind : For home(indoor) use
Material : ABS
Manufactured date : Indicated separately
Manufacturer : FTLab
* Only the manufacturer or agency will inspect and supply
Country of manufacture : Republic of Korea
Questions : www.radonftlab.com
FTLAB succeeded in developing a real-time Radon
sensor in 2015, and also succeeded in mass production
in 2016, we launched RADON FTLAB.
COPYRIGHT (C)FTLAB Co., Ltd ALL RIGHT RESREVED.
503ho, 8, 330beon-gil,
Haebong-ro, Danwon-gu,
Ansan-si, Gyeonggi-do, Korea
FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
① BLE access : Indicates it is connected with smartphone using BLE communication
② Shock detect sign : It appears when a shock or vibration from outside is sensed, and
the measurement stops at the time
③ Radon concentration : Measured value of Radon shown in 10 minute interval
④ Unit of measure : Shown in pCi/l or Bq/㎥. Unit can be changed by smartphone app.
⑤ Information display : SN, peak value, 1/2/7 day and month average, measurement time,
pulse count per 10 minute measurement (present value/last value)
Name and function of each part
BLE Access
Shock detection
Radon concentration
Unit
Information
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Name and function of each part
Front
LED : Red LED flashes for 30 seconds when Radon value exceeds
reference value.
Green LED flashes when Wi-Fi connection is not normal.
Ventilation window
LCD : Information display window for Wi-Fi access, shock detection,
Radon concentration, etc.
Rear
Power
12V DC
Radon ?
1. Radon is a colorless, odorless and tasteless radioactive gas.
Radon, a gas originating from radium which is generated by the collapse of
uranium in soil, is everywhere on earth. It penetrates indoors mainly from the
ground or building materials. The gases that cause sick house syndrome and
other noxious gases luckily smell. Urban gas and LPG were deliberately
smelled. However, radon does not smell nor can be seen. And no matter how
many years have passed, it is constantly released from the wall, ceiling and
floor.
2. Radon is 8 times heavier than air and is easily concentrated in the house.
Radon has the half-life of 3.8 days and makes alpha decay. The alpha particle
emitted from radon has the smallest penetration power among the radiation
rays and can not penetrate even a single piece of paper, but its destructive
power is so great that the cells are damaged if they are directly impacted by
radon, even having a nickname of "silent murderer". This is why radon detec-
tion sensor is absolutely needed in home.
3. Radon gas causes lung cancer.
Three causes of modern female lung cancer are passive smoking, ultrafine
particles and radon. When radon gas enters the lung through breathing, alpha
particles released from radon damage the lung cells. Since once destroyed
lung cells are not regenerated, prolonged exposure to high concentration of
radon gas will increase the likelihood of lung cancer. Therefore, the United
States Environmental Protection Agency(EPA) designated Radon as a must
be managed hazardous gas for healthy life.
- Accurate measurement value of the average radon level can be obtained when
the house is empty for 1 or 2 days.
- Reliable value can be obtained about 1 hour after start of the measurement.
- Radon concentration in the house is generally high at dawn and low at daytime,
so continuous measurement for more than 24 hours is necessary.
Precautions
•Please, Measure in an environment free from vibration.
•Shock or disassembly will cause the equipment to malfunction and will not
be included in the warranty. (the unit will display “ERR” message)
•Abnormal data can be measured when using near a strong electromagnetic
radiation source such as high voltage transmission line, subway line, Wifi
transmitter(1Meter or less), microwave oven(1M or less) ('OVER'
message)
•Use only indoors. No waterproof.
•Use the provided DC 12V adapter.
•Continuous use in an environment with relative humidity of 80% or
higher is prohibited.
•A warning message may be sent to the set mobile device when it is higher
than the set radon concentration.
•Proper operating temperature range is 10℃ ~ 40℃ (50°F ~ 100°F)
•The warranty period is one year after purchase.
<Radon concentration fluctuation graph>
Seasonal radon concentration
WinterAutumnSummerSpring
Daily radon concentration
Day Evening Day
Dawn
Precautions when using
Example of proper installation
· please, let the device where there is no ventilation
environment to check the area's usual radon status.
Prohibited
· Install at least 50cm apart from wall, window and floor.
· In general, proper places to install are on desk, table
in the living room, or on dining table in the kitchen.
Caution
1. For accurate measurement, close windows and doors tightly.
2. When RadonEye + is connected to DC 12V adaptor, measurement
starts automatically.
3. After the power is on, the wait time (10 minutes) is indicated by ‘- -’.
When wait time is over, the measured values are displayed from
10 minutes later. Measurements are displayed in 10 minute interval,
and saved in 1 hour interval.
To start the device
RADONEYE +
C_device
P_device
Measured value
12h 24h36h
Actual value
1h
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Precautions before using App.
This is the User's Manual for controlling RadonEye + device made in
Radon FTLab. Please refer to the detailed manual on the Radon FTLab
website (http://RadonFTLab.com) for the equipment and PC program
manual.
• Since it is an application that operates on a Wi-Fi base, there may be
operational limitations.
• It works properly in Android 4.3 version or iOS 8.0 version or later
• If the distance between the device and the smart device increases,
the
connection may be lost.
• In the 5G Internet environment, there are restrictions in the use of the
product, so please use 2.4G.
• We recommend user to agree to the privacy policy during the app
setting stage for trouble-free data transfer.
• Bluetooth and GPS must be enabled before using
• The time in the area where the equipment is installed is applied to the
data recorded after app setting/direct connection. The factory
Bluetooth & GPS function of
mobile device should be
activated for
RadonEye + setting
GPS
Bluetooth
RadonEye +
RadonEye + is the world's first IoT smart radon detector that is used in connec-
tion with web database based on WiFi. Therefore, RadonEye + is suitable for
real-time radon monitoring and easy to create Real-Time Radon Map. Manufac-
turer, Radon FTLab provides web database, radon-net.com, which means the
user can access the data every time, everywhere by smart phone, tablet or
internet connected desktop PC.
The sensitivity performance of RadonEye + is like a standard instrument. It is 20
times higher when it is compared with other general customer’s radon detector,
so the measurement data is fast and precise. Radon measurement data can be
recorded within 1 hour with below
±
10% error from starting time of measurement
and the data will be updated every 10 minutes so the user will get to know the
diminishing trend of indoor radon level just within 30 minutes by ventilation or
window open.
RadonEye + has added temperature & humidity sensor and measurement time
recording and extended the measurement range to 255pCi / l.
RadonEye + offers free web uploading service at least 2 years.
Measurement
Range
Precision
Accuracy
Data log
Display
Mobile control
Sensing factor
Time checking
Web access
Mobile notification
WiFi, Bluetooth
Radon,Humidity,Temperature
O
O
O
0.1~255 pCi/l
(1 ~9,435 Bq/㎥)
Model RadonEye (RD200) RadonEye + (RD200P2)
Bluetooth
Radon
X
X
X
0.1~100 pCi/l
(1 ~3,700 Bq/㎥)
< ±10%at 10pCi/l (370Bq/㎥)
< ±10%(min. error <±0.5pCi/l)
max1year(1hour interval)
0.96 inch OLED
< RadonEye VS RadonEye + >
1. What should I do under condition of no Wi-Fi around available?
A : RadonEye Plus2 automatically starts measuring when power is simply connected, so all you need to do is just select 'Connected Devices'
menu in your smartphone application even if you don't have a Wi-Fi
2. Tell me how to set up an app. when errors.
2.1. RadonEye Plus2 you are trying to set is not on the list.
A (iPhone) : Switch Bluetooth off and on to update the list again.
A (Android) : Click the "Rescan" button to update the list again.
2.2. The Wi-Fi list displayed on the app. does not contain the desired Wi-Fi I’d like to connect to.
A : Click the ‘refresh’ icon to update the Wi-Fi list. for your reference, 5GHz Wi-Fi is not supported and will not appear in the list.
2.3. If 'Wi-Fi settings failed' is displayed when next button is clicked after entering the Wi-Fi information.
A : If the green LED on RadonEye Plus2 keeps blinking and Wi-Fi connection is not successful, please check if Wi-Fi password is entered
correctly and internet connection status of the Router.
2.4. If the message 'RadonEye Plus2 registration failed' is displayed when the button is clicked after entering the Wi-Fi information,
A : Smartphone should also be Internet-connected through Wi-Fi / LTE / 3G
Check the Internet connection status of the smart device and proceed with setting under this circumstance.
2.5. If other cases of setting failure
A : Check the Wi-Fi and GPS connection on your smartphone, then turn the device off and on and run.
3. How can I change RadonEye Plus2 wifi connection that’s been already set into previous wifi place?
A : If you have Wi-Fi in your environment, you can set it up again and use it easily by clicking ‘Main’-‘Sub Menu’-‘Network’
4. It continues to show the high concentration figure, Is it out of order?
A : In this case, leave it in a well ventilated location for about two days and try to measure the low concentration at veranda, indoor air quality,
and high concentration in sequence
Q&A
RADON NET
RadonEye + provides Remote Radon Monitoring Network Service. You can
check radon value in the web browser by registering the registration key which
is given when you access the radon-net.com website when setting the app.
You can also check the local radon value at any time through Radon Map.
· My Devices
· Information
· Device Location
· Device Log (Graph)
· Radon Map
Sign In
Guest
Email
RADON NET
Password
Good
Normal
Warning
Bad
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
Smart Radon Gas Monitor
RADONEYE +
Operation Manual
RD200P2
•Type : pulsed ion chamber
•First reliable data out : < 60min
•Data interval : 10min update (60min moving average)
•Sensitivity : 0.5cpm/pCi/l at 10pCi/l (30cph/pCi/l)
•Operating range : 10℃ ~ 40℃ (50°F ~ 100°F), RH < 80%
•Measurement range : 0.1 ~ 255 pCi/l (9,435 Bq/㎥)
* Environment reference value 4pCi/l (148 Bq/㎥)
•Precision : < ±10% at 10pCi/l
•Accuracy : < ±10% (min. error <±0.5pCi/l ) at 10pCi/l
•Interval of measurement value saving : 60 minutes
•Storage capacity : 1 year
•Power consumption : DC12 ± 0.1V, 0.1A ( Use 12V DC adapter)
•Size : Φ80(mm) x 120(mm)
•Display : 0.96 inch OLED
•Data communication : Wi-Fi (internet), Bluetooth
•Weight : 520g
•Altitude : Up to 2000 m
•pollution degree : 2
* Radon Eye Plus 2 is a function upgraded version of Radon Eye Plus that enhances
Wi-Fi setup convenience by adding BLE communication to previous Radon Eye Plus
products.
* In March 2019, the model name of RadonEye Plus2 changes from RD200P to
RD200P2.
Product Specifications
Descriptive labeling in accordance with Quality
Management and Safety Control Act for Industrial Goods.
Instrument type: RD200P2
Instrument name : RADONEYE +
Kind : For home(indoor) use
Material : ABS
Manufactured date : Indicated separately
Manufacturer : FTLab
* Only the manufacturer or agency will inspect and supply
Country of manufacture : Republic of Korea
Questions : www.radonftlab.com
FTLAB succeeded in developing a real-time Radon
sensor in 2015, and also succeeded in mass production
in 2016, we launched RADON FTLAB.
COPYRIGHT (C)FTLAB Co., Ltd ALL RIGHT RESREVED.
503ho, 8, 330beon-gil,
Haebong-ro, Danwon-gu,
Ansan-si, Gyeonggi-do, Korea
FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
① BLE access : Indicates it is connected with smartphone using BLE communication
② Shock detect sign : It appears when a shock or vibration from outside is sensed, and
the measurement stops at the time
③ Radon concentration : Measured value of Radon shown in 10 minute interval
④ Unit of measure : Shown in pCi/l or Bq/㎥. Unit can be changed by smartphone app.
⑤ Information display : SN, peak value, 1/2/7 day and month average, measurement time,
pulse count per 10 minute measurement (present value/last value)
Name and function of each part
BLE Access
Shock detection
Radon concentration
Unit
Information
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Name and function of each part
Front
LED : Red LED flashes for 30 seconds when Radon value exceeds
reference value.
Green LED flashes when Wi-Fi connection is not normal.
Ventilation window
LCD : Information display window for Wi-Fi access, shock detection,
Radon concentration, etc.
Rear
Power
12V DC
Radon ?
1. Radon is a colorless, odorless and tasteless radioactive gas.
Radon, a gas originating from radium which is generated by the collapse of
uranium in soil, is everywhere on earth. It penetrates indoors mainly from the
ground or building materials. The gases that cause sick house syndrome and
other noxious gases luckily smell. Urban gas and LPG were deliberately
smelled. However, radon does not smell nor can be seen. And no matter how
many years have passed, it is constantly released from the wall, ceiling and
floor.
2. Radon is 8 times heavier than air and is easily concentrated in the house.
Radon has the half-life of 3.8 days and makes alpha decay. The alpha particle
emitted from radon has the smallest penetration power among the radiation
rays and can not penetrate even a single piece of paper, but its destructive
power is so great that the cells are damaged if they are directly impacted by
radon, even having a nickname of "silent murderer". This is why radon detec-
tion sensor is absolutely needed in home.
3. Radon gas causes lung cancer.
Three causes of modern female lung cancer are passive smoking, ultrafine
particles and radon. When radon gas enters the lung through breathing, alpha
particles released from radon damage the lung cells. Since once destroyed
lung cells are not regenerated, prolonged exposure to high concentration of
radon gas will increase the likelihood of lung cancer. Therefore, the United
States Environmental Protection Agency(EPA) designated Radon as a must
be managed hazardous gas for healthy life.
- Accurate measurement value of the average radon level can be obtained when
the house is empty for 1 or 2 days.
- Reliable value can be obtained about 1 hour after start of the measurement.
- Radon concentration in the house is generally high at dawn and low at daytime,
so continuous measurement for more than 24 hours is necessary.
Precautions
•Please, Measure in an environment free from vibration.
•Shock or disassembly will cause the equipment to malfunction and will not
be included in the warranty. (the unit will display “ERR” message)
•Abnormal data can be measured when using near a strong electromagnetic
radiation source such as high voltage transmission line, subway line, Wifi
transmitter(1Meter or less), microwave oven(1M or less) ('OVER'
message)
•Use only indoors. No waterproof.
•Use the provided DC 12V adapter.
•Continuous use in an environment with relative humidity of 80% or
higher is prohibited.
•A warning message may be sent to the set mobile device when it is higher
than the set radon concentration.
•Proper operating temperature range is 10℃ ~ 40℃ (50°F ~ 100°F)
•The warranty period is one year after purchase.
<Radon concentration fluctuation graph>
Seasonal radon concentration
WinterAutumnSummerSpring
Daily radon concentration
Day Evening Day
Dawn
Precautions when using
Example of proper installation
· please, let the device where there is no ventilation
environment to check the area's usual radon status.
Prohibited
· Install at least 50cm apart from wall, window and floor.
· In general, proper places to install are on desk, table
in the living room, or on dining table in the kitchen.
Caution
1. For accurate measurement, close windows and doors tightly.
2. When RadonEye + is connected to DC 12V adaptor, measurement
starts automatically.
3. After the power is on, the wait time (10 minutes) is indicated by ‘- -’.
When wait time is over, the measured values are displayed from
10 minutes later. Measurements are displayed in 10 minute interval,
and saved in 1 hour interval.
To start the device
RADONEYE +
C_device
P_device
Measured value
12h 24h36h
Actual value
1h
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Precautions before using App.
This is the User's Manual for controlling RadonEye + device made in
Radon FTLab. Please refer to the detailed manual on the Radon FTLab
website (http://RadonFTLab.com) for the equipment and PC program
manual.
• Since it is an application that operates on a Wi-Fi base, there may be
operational limitations.
• It works properly in Android 4.3 version or iOS 8.0 version or later
• If the distance between the device and the smart device increases,
the
connection may be lost.
• In the 5G Internet environment, there are restrictions in the use of the
product, so please use 2.4G.
• We recommend user to agree to the privacy policy during the app
setting stage for trouble-free data transfer.
• Bluetooth and GPS must be enabled before using
• The time in the area where the equipment is installed is applied to the
data recorded after app setting/direct connection. The factory
Bluetooth & GPS function of
mobile device should be
activated for
RadonEye + setting
GPS
Bluetooth
RadonEye +
RadonEye + is the world's first IoT smart radon detector that is used in connec-
tion with web database based on WiFi. Therefore, RadonEye + is suitable for
real-time radon monitoring and easy to create Real-Time Radon Map. Manufac-
turer, Radon FTLab provides web database, radon-net.com, which means the
user can access the data every time, everywhere by smart phone, tablet or
internet connected desktop PC.
The sensitivity performance of RadonEye + is like a standard instrument. It is 20
times higher when it is compared with other general customer’s radon detector,
so the measurement data is fast and precise. Radon measurement data can be
recorded within 1 hour with below
±
10% error from starting time of measurement
and the data will be updated every 10 minutes so the user will get to know the
diminishing trend of indoor radon level just within 30 minutes by ventilation or
window open.
RadonEye + has added temperature & humidity sensor and measurement time
recording and extended the measurement range to 255pCi / l.
RadonEye + offers free web uploading service at least 2 years.
Measurement
Range
Precision
Accuracy
Data log
Display
Mobile control
Sensing factor
Time checking
Web access
Mobile notification
WiFi, Bluetooth
Radon,Humidity,Temperature
O
O
O
0.1~255 pCi/l
(1 ~9,435 Bq/㎥)
Model RadonEye (RD200) RadonEye + (RD200P2)
Bluetooth
Radon
X
X
X
0.1~100 pCi/l
(1 ~3,700 Bq/㎥)
< ±10%at 10pCi/l (370Bq/㎥)
< ±10%(min. error <±0.5pCi/l)
max1year(1hour interval)
0.96 inch OLED
< RadonEye VS RadonEye + >
1. What should I do under condition of no Wi-Fi around available?
A : RadonEye Plus2 automatically starts measuring when power is simply connected, so all you need to do is just select 'Connected Devices'
menu in your smartphone application even if you don't have a Wi-Fi
2. Tell me how to set up an app. when errors.
2.1. RadonEye Plus2 you are trying to set is not on the list.
A (iPhone) : Switch Bluetooth off and on to update the list again.
A (Android) : Click the "Rescan" button to update the list again.
2.2. The Wi-Fi list displayed on the app. does not contain the desired Wi-Fi I’d like to connect to.
A : Click the ‘refresh’ icon to update the Wi-Fi list. for your reference, 5GHz Wi-Fi is not supported and will not appear in the list.
2.3. If 'Wi-Fi settings failed' is displayed when next button is clicked after entering the Wi-Fi information.
A : If the green LED on RadonEye Plus2 keeps blinking and Wi-Fi connection is not successful, please check if Wi-Fi password is entered
correctly and internet connection status of the Router.
2.4. If the message 'RadonEye Plus2 registration failed' is displayed when the button is clicked after entering the Wi-Fi information,
A : Smartphone should also be Internet-connected through Wi-Fi / LTE / 3G
Check the Internet connection status of the smart device and proceed with setting under this circumstance.
2.5. If other cases of setting failure
A : Check the Wi-Fi and GPS connection on your smartphone, then turn the device off and on and run.
3. How can I change RadonEye Plus2 wifi connection that’s been already set into previous wifi place?
A : If you have Wi-Fi in your environment, you can set it up again and use it easily by clicking ‘Main’-‘Sub Menu’-‘Network’
4. It continues to show the high concentration figure, Is it out of order?
A : In this case, leave it in a well ventilated location for about two days and try to measure the low concentration at veranda, indoor air quality,
and high concentration in sequence
Q&A
RADON NET
RadonEye + provides Remote Radon Monitoring Network Service. You can
check radon value in the web browser by registering the registration key which
is given when you access the radon-net.com website when setting the app.
You can also check the local radon value at any time through Radon Map.
· My Devices
· Information
· Device Location
· Device Log (Graph)
· Radon Map
Sign In
Guest
Email
RADON NET
Password
Good
Normal
Warning
Bad
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

① ADD NEW DEVICE : To set up
RadonEye + to connect with Wi-Fi
The set up RadonEye + will be
registered in the smart device.
② DEVICE CONNECTON : Directly connect
to RadonEye + having no network
setting and check data
App Execution Screen
DEVICE CONNECTION
New Members Screen
Email
Password
Log in
Sign up
Log in
Add New Device
① Need to activate GPS and Bluetooth
Select Device
① Check the serial number
shown in the bottom of the device
② Select device from the list.
Accepting Privacy Policy Statement
① Privacy protection (required)
② Reveal device location,
radon value (select)
Users who do not agree the agreement
can't use Radon Monitoring Network Service.
(If the WiFi connection is not possible, the equipment data
can be directly managed by communication with BLE)
Setting Installed Location and Number
① Device Name : Enter directly within
20 characters
② In case of push alarm,
it is shown as the set information
Device Name
Wi-Fi Setting
① Wi-Fi to be connected to RadonEye +
② Enter Wi-Fi password
RadonEye + does not
support 5GHz Wi-Fi
Wi-Fi Setting Successful
Wi-Fi setting successful
Agree to all
Privacy protection
Reveal device location,
radon value
Close
DEVICE CONNECTION
① Activate sub-menu by clicking arrow button
② Network : To reset network
③ Alarm : To set Daily Alarm and Warning Alarm
④ Cloud : Real time data can be checked from outside
⑤ Delete : To delete selected device from the list
Main Screen ③ Push Alarm Setting
•Daily Enable : Measured value
is sent by Alarm message
at the set time everyday
•Warning Enable : When
measured value is higher
than the set value,
Alarm message is sent
④To Use Cloud
• Real time data can be
checked remotely without
connecting RadonEye +
⑤Delete
• To delete selected device from the list
Do you want to delete the
selected device from the list?
DEVICE CONNECTION
1. App Installation & Wi-Fi Setting
2. Sub-menu Setting in App Main Menu 3. App Features and the Use
Features of ‘OPERATION’ Screen
① Displays the measurement time
② Peak Value / 1day Average / 2day Average / 7day Average / 1Month Average
- Peak Value : The maximum value of the measured radon value
(The value is displayed after 1 hour from the device plugged in)
- 1/2/7 day Average : Average value of radon data measured for 1/2/7 day
(From the time 1/2/7 day after the measurement time, it is displayed alternately with Value)
- 1Month Average : Average value of radon data measured for 1month
(From the time 1month after the measurement time, it is displayed alternately with Peak Value, 1/2/7day Average)
③ Temperature & humidity
④ Status Display Window
-Icon at the top : Smartphone <-> RadonEye + Device connection status
-Icon at middle : Wi-Fi Connection Status on RadonEye +
-Icon at bottom : Showing status when the instrument is unstable or not in proper condition
⑤ Measured Radon Value Display Window
-The radon value measured by RadonEye + is updated in 10 minute interval
⑥ Measured Radon Value Graph
-The values measured by 1 hour interval in the device is saved in log value
and shown in graph(maximum 24 values)
-When checking the whole data, Detailed analysis is possible through MORE DATA
in the upper right corner
⑦ Clear button : To initialize the data saved in RadonEye + device
⑧ Data Reload button : To retrieve the data saved in RadonEye + device
-Possible to output in pCi/l or Bq/㎥ values through Radio button
-Zoom In, Zoom Out are possible
-Possible to set display period using buttons in the bottom
⑨ Sava As button : To save the data in the device retrieved through Data Reload
as a txt file in smartphone
※ The location of the file to be saved in smartphone
· Android smart devices : File Manager -> \Radon FTLab folder
· iPhone PC connection : iTunes -> File sharing-> App -> RadonEye Plus2 - Document
‘SETTING’ Screen
① Selecting Unit
- To change the unit of the radon value
in RadonEye +
② To select Alarm Use/Not-use
- Display in LED of RadonEye +
- Interval : The interval of LED display
when alarm status is maintained
③ To select temperature unit
- To select Centigrade(°C) or Fahrenheit(°F)
To disconnect Wi-Fi
- To disconnect Wi-Fi from RadonEye +
- Cloud and Radon Net cannot be used,
and data can be checked only through
direct connection
Buzzer sounds
- Mute during connection and setting
Unit
Alarm ON
Centigrade (°C) Fahrenheit (°F)
Temperature unit
③
Buzzer sounds
APPLY
To disconnect Wi-Fi
RadonEye +
⑥
⑥ AI Speaker
Radon Net
Log in
File Load
What is Radon?
Radon Net(RMNS)
AI Speaker
• With the success of Wi-fi setup,
RadonEye + can use the
affiliated AI voice service
Please check if Wi-Fi is connected alright.
Alexa
OPERATION
① ② ③
⑤
⑥
⑦ ⑧ ⑨
SETTING
0.51
Clear
Data Reload Save As
RadonEye +
④
2
2
22
Search ‘Radoneye plus2’ App
(Note : This is not ‘Radoneye plus’ App)

① ADD NEW DEVICE : To set up
RadonEye + to connect with Wi-Fi
The set up RadonEye + will be
registered in the smart device.
② DEVICE CONNECTON : Directly connect
to RadonEye + having no network
setting and check data
App Execution Screen
DEVICE CONNECTION
New Members Screen
Email
Password
Log in
Sign up
Log in
Add New Device
① Need to activate GPS and Bluetooth
Select Device
① Check the serial number
shown in the bottom of the device
② Select device from the list.
Accepting Privacy Policy Statement
① Privacy protection (required)
② Reveal device location,
radon value (select)
Users who do not agree the agreement
can't use Radon Monitoring Network Service.
(If the WiFi connection is not possible, the equipment data
can be directly managed by communication with BLE)
Setting Installed Location and Number
① Device Name : Enter directly within
20 characters
② In case of push alarm,
it is shown as the set information
Device Name
Wi-Fi Setting
① Wi-Fi to be connected to RadonEye +
② Enter Wi-Fi password
RadonEye + does not
support 5GHz Wi-Fi
Wi-Fi Setting Successful
Wi-Fi setting successful
Agree to all
Privacy protection
Reveal device location,
radon value
Close
DEVICE CONNECTION
① Activate sub-menu by clicking arrow button
② Network : To reset network
③ Alarm : To set Daily Alarm and Warning Alarm
④ Cloud : Real time data can be checked from outside
⑤ Delete : To delete selected device from the list
Main Screen ③ Push Alarm Setting
•Daily Enable : Measured value
is sent by Alarm message
at the set time everyday
•Warning Enable : When
measured value is higher
than the set value,
Alarm message is sent
④To Use Cloud
• Real time data can be
checked remotely without
connecting RadonEye +
⑤Delete
• To delete selected device from the list
Do you want to delete the
selected device from the list?
DEVICE CONNECTION
1. App Installation & Wi-Fi Setting
2. Sub-menu Setting in App Main Menu 3. App Features and the Use
Features of ‘OPERATION’ Screen
① Displays the measurement time
② Peak Value / 1day Average / 2day Average / 7day Average / 1Month Average
- Peak Value : The maximum value of the measured radon value
(The value is displayed after 1 hour from the device plugged in)
- 1/2/7 day Average : Average value of radon data measured for 1/2/7 day
(From the time 1/2/7 day after the measurement time, it is displayed alternately with Value)
- 1Month Average : Average value of radon data measured for 1month
(From the time 1month after the measurement time, it is displayed alternately with Peak Value, 1/2/7day Average)
③ Temperature & humidity
④ Status Display Window
-Icon at the top : Smartphone <-> RadonEye + Device connection status
-Icon at middle : Wi-Fi Connection Status on RadonEye +
-Icon at bottom : Showing status when the instrument is unstable or not in proper condition
⑤ Measured Radon Value Display Window
-The radon value measured by RadonEye + is updated in 10 minute interval
⑥ Measured Radon Value Graph
-The values measured by 1 hour interval in the device is saved in log value
and shown in graph(maximum 24 values)
-When checking the whole data, Detailed analysis is possible through MORE DATA
in the upper right corner
⑦ Clear button : To initialize the data saved in RadonEye + device
⑧ Data Reload button : To retrieve the data saved in RadonEye + device
-Possible to output in pCi/l or Bq/㎥ values through Radio button
-Zoom In, Zoom Out are possible
-Possible to set display period using buttons in the bottom
⑨ Sava As button : To save the data in the device retrieved through Data Reload
as a txt file in smartphone
※ The location of the file to be saved in smartphone
· Android smart devices : File Manager -> \Radon FTLab folder
· iPhone PC connection : iTunes -> File sharing-> App -> RadonEye Plus2 - Document
‘SETTING’ Screen
① Selecting Unit
- To change the unit of the radon value
in RadonEye +
② To select Alarm Use/Not-use
- Display in LED of RadonEye +
- Interval : The interval of LED display
when alarm status is maintained
③ To select temperature unit
- To select Centigrade(°C) or Fahrenheit(°F)
To disconnect Wi-Fi
- To disconnect Wi-Fi from RadonEye +
- Cloud and Radon Net cannot be used,
and data can be checked only through
direct connection
Buzzer sounds
- Mute during connection and setting
Unit
Alarm ON
Centigrade (°C) Fahrenheit (°F)
Temperature unit
③
Buzzer sounds
APPLY
To disconnect Wi-Fi
RadonEye +
⑥
⑥ AI Speaker
Radon Net
Log in
File Load
What is Radon?
Radon Net(RMNS)
AI Speaker
• With the success of Wi-fi setup,
RadonEye + can use the
affiliated AI voice service
Please check if Wi-Fi is connected alright.
Alexa
OPERATION
① ② ③
⑤
⑥
⑦ ⑧ ⑨
SETTING
0.51
Clear
Data Reload Save As
RadonEye +
④
2
2
22
Search ‘Radoneye plus2’ App
(Note : This is not ‘Radoneye plus’ App)

① ADD NEW DEVICE : To set up
RadonEye + to connect with Wi-Fi
The set up RadonEye + will be
registered in the smart device.
② DEVICE CONNECTON : Directly connect
to RadonEye + having no network
setting and check data
App Execution Screen
DEVICE CONNECTION
New Members Screen
Email
Password
Log in
Sign up
Log in
Add New Device
① Need to activate GPS and Bluetooth
Select Device
① Check the serial number
shown in the bottom of the device
② Select device from the list.
Accepting Privacy Policy Statement
① Privacy protection (required)
② Reveal device location,
radon value (select)
Users who do not agree the agreement
can't use Radon Monitoring Network Service.
(If the WiFi connection is not possible, the equipment data
can be directly managed by communication with BLE)
Setting Installed Location and Number
① Device Name : Enter directly within
20 characters
② In case of push alarm,
it is shown as the set information
Device Name
Wi-Fi Setting
① Wi-Fi to be connected to RadonEye +
② Enter Wi-Fi password
RadonEye + does not
support 5GHz Wi-Fi
Wi-Fi Setting Successful
Wi-Fi setting successful
Agree to all
Privacy protection
Reveal device location,
radon value
Close
DEVICE CONNECTION
① Activate sub-menu by clicking arrow button
② Network : To reset network
③ Alarm : To set Daily Alarm and Warning Alarm
④ Cloud : Real time data can be checked from outside
⑤ Delete : To delete selected device from the list
Main Screen ③ Push Alarm Setting
•Daily Enable : Measured value
is sent by Alarm message
at the set time everyday
•Warning Enable : When
measured value is higher
than the set value,
Alarm message is sent
④To Use Cloud
• Real time data can be
checked remotely without
connecting RadonEye +
⑤Delete
• To delete selected device from the list
Do you want to delete the
selected device from the list?
DEVICE CONNECTION
1. App Installation & Wi-Fi Setting
2. Sub-menu Setting in App Main Menu 3. App Features and the Use
Features of ‘OPERATION’ Screen
① Displays the measurement time
② Peak Value / 1day Average / 2day Average / 7day Average / 1Month Average
- Peak Value : The maximum value of the measured radon value
(The value is displayed after 1 hour from the device plugged in)
- 1/2/7 day Average : Average value of radon data measured for 1/2/7 day
(From the time 1/2/7 day after the measurement time, it is displayed alternately with Value)
- 1Month Average : Average value of radon data measured for 1month
(From the time 1month after the measurement time, it is displayed alternately with Peak Value, 1/2/7day Average)
③ Temperature & humidity
④ Status Display Window
-Icon at the top : Smartphone <-> RadonEye + Device connection status
-Icon at middle : Wi-Fi Connection Status on RadonEye +
-Icon at bottom : Showing status when the instrument is unstable or not in proper condition
⑤ Measured Radon Value Display Window
-The radon value measured by RadonEye + is updated in 10 minute interval
⑥ Measured Radon Value Graph
-The values measured by 1 hour interval in the device is saved in log value
and shown in graph(maximum 24 values)
-When checking the whole data, Detailed analysis is possible through MORE DATA
in the upper right corner
⑦ Clear button : To initialize the data saved in RadonEye + device
⑧ Data Reload button : To retrieve the data saved in RadonEye + device
-Possible to output in pCi/l or Bq/㎥ values through Radio button
-Zoom In, Zoom Out are possible
-Possible to set display period using buttons in the bottom
⑨ Sava As button : To save the data in the device retrieved through Data Reload
as a txt file in smartphone
※ The location of the file to be saved in smartphone
· Android smart devices : File Manager -> \Radon FTLab folder
· iPhone PC connection : iTunes -> File sharing-> App -> RadonEye Plus2 - Document
‘SETTING’ Screen
① Selecting Unit
- To change the unit of the radon value
in RadonEye +
② To select Alarm Use/Not-use
- Display in LED of RadonEye +
- Interval : The interval of LED display
when alarm status is maintained
③ To select temperature unit
- To select Centigrade(°C) or Fahrenheit(°F)
To disconnect Wi-Fi
- To disconnect Wi-Fi from RadonEye +
- Cloud and Radon Net cannot be used,
and data can be checked only through
direct connection
Buzzer sounds
- Mute during connection and setting
Unit
Alarm ON
Centigrade (°C) Fahrenheit (°F)
Temperature unit
③
Buzzer sounds
APPLY
To disconnect Wi-Fi
RadonEye +
⑥
⑥ AI Speaker
Radon Net
Log in
File Load
What is Radon?
Radon Net(RMNS)
AI Speaker
• With the success of Wi-fi setup,
RadonEye + can use the
affiliated AI voice service
Please check if Wi-Fi is connected alright.
Alexa
OPERATION
① ② ③
⑤
⑥
⑦ ⑧ ⑨
SETTING
0.51
Clear
Data Reload Save As
RadonEye +
④
2
2
22
Search ‘Radoneye plus2’ App
(Note : This is not ‘Radoneye plus’ App)

FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
Smart Radon Gas Monitor
RADONEYE +
Operation Manual
RD200P2
•Type : pulsed ion chamber
•First reliable data out : < 60min
•Data interval : 10min update (60min moving average)
•Sensitivity : 0.5cpm/pCi/l at 10pCi/l (30cph/pCi/l)
•Operating range : 10℃ ~ 40℃ (50°F ~ 100°F), RH < 80%
•Measurement range : 0.1 ~ 255 pCi/l (9,435 Bq/㎥)
* Environment reference value 4pCi/l (148 Bq/㎥)
•Precision : < ±10% at 10pCi/l
•Accuracy : < ±10% (min. error <±0.5pCi/l ) at 10pCi/l
•Interval of measurement value saving : 60 minutes
•Storage capacity : 1 year
•Power consumption : DC12 ± 0.1V, 0.1A ( Use 12V DC adapter)
•Size : Φ80(mm) x 120(mm)
•Display : 0.96 inch OLED
•Data communication : Wi-Fi (internet), Bluetooth
•Weight : 520g
•Altitude : Up to 2000 m
•pollution degree : 2
* Radon Eye Plus 2 is a function upgraded version of Radon Eye Plus that enhances
Wi-Fi setup convenience by adding BLE communication to previous Radon Eye Plus
products.
* In March 2019, the model name of RadonEye Plus2 changes from RD200P to
RD200P2.
Product Specifications
Descriptive labeling in accordance with Quality
Management and Safety Control Act for Industrial Goods.
Instrument type: RD200P2
Instrument name : RADONEYE +
Kind : For home(indoor) use
Material : ABS
Manufactured date : Indicated separately
Manufacturer : FTLab
* Only the manufacturer or agency will inspect and supply
Country of manufacture : Republic of Korea
Questions : www.radonftlab.com
FTLAB succeeded in developing a real-time Radon
sensor in 2015, and also succeeded in mass production
in 2016, we launched RADON FTLAB.
COPYRIGHT (C)FTLAB Co., Ltd ALL RIGHT RESREVED.
503ho, 8, 330beon-gil,
Haebong-ro, Danwon-gu,
Ansan-si, Gyeonggi-do, Korea
FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
① BLE access : Indicates it is connected with smartphone using BLE communication
② Shock detect sign : It appears when a shock or vibration from outside is sensed, and
the measurement stops at the time
③ Radon concentration : Measured value of Radon shown in 10 minute interval
④ Unit of measure : Shown in pCi/l or Bq/㎥. Unit can be changed by smartphone app.
⑤ Information display : SN, peak value, 1/2/7 day and month average, measurement time,
pulse count per 10 minute measurement (present value/last value)
Name and function of each part
BLE Access
Shock detection
Radon concentration
Unit
Information
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Name and function of each part
Front
LED : Red LED flashes for 30 seconds when Radon value exceeds
reference value.
Green LED flashes when Wi-Fi connection is not normal.
Ventilation window
LCD : Information display window for Wi-Fi access, shock detection,
Radon concentration, etc.
Rear
Power
12V DC
Radon ?
1. Radon is a colorless, odorless and tasteless radioactive gas.
Radon, a gas originating from radium which is generated by the collapse of
uranium in soil, is everywhere on earth. It penetrates indoors mainly from the
ground or building materials. The gases that cause sick house syndrome and
other noxious gases luckily smell. Urban gas and LPG were deliberately
smelled. However, radon does not smell nor can be seen. And no matter how
many years have passed, it is constantly released from the wall, ceiling and
floor.
2. Radon is 8 times heavier than air and is easily concentrated in the house.
Radon has the half-life of 3.8 days and makes alpha decay. The alpha particle
emitted from radon has the smallest penetration power among the radiation
rays and can not penetrate even a single piece of paper, but its destructive
power is so great that the cells are damaged if they are directly impacted by
radon, even having a nickname of "silent murderer". This is why radon detec-
tion sensor is absolutely needed in home.
3. Radon gas causes lung cancer.
Three causes of modern female lung cancer are passive smoking, ultrafine
particles and radon. When radon gas enters the lung through breathing, alpha
particles released from radon damage the lung cells. Since once destroyed
lung cells are not regenerated, prolonged exposure to high concentration of
radon gas will increase the likelihood of lung cancer. Therefore, the United
States Environmental Protection Agency(EPA) designated Radon as a must
be managed hazardous gas for healthy life.
- Accurate measurement value of the average radon level can be obtained when
the house is empty for 1 or 2 days.
- Reliable value can be obtained about 1 hour after start of the measurement.
- Radon concentration in the house is generally high at dawn and low at daytime,
so continuous measurement for more than 24 hours is necessary.
Precautions
•Please, Measure in an environment free from vibration.
•Shock or disassembly will cause the equipment to malfunction and will not
be included in the warranty. (the unit will display “ERR” message)
•Abnormal data can be measured when using near a strong electromagnetic
radiation source such as high voltage transmission line, subway line, Wifi
transmitter(1Meter or less), microwave oven(1M or less) ('OVER'
message)
•Use only indoors. No waterproof.
•Use the provided DC 12V adapter.
•Continuous use in an environment with relative humidity of 80% or
higher is prohibited.
•A warning message may be sent to the set mobile device when it is higher
than the set radon concentration.
•Proper operating temperature range is 10℃ ~ 40℃ (50°F ~ 100°F)
•The warranty period is one year after purchase.
<Radon concentration fluctuation graph>
Seasonal radon concentration
WinterAutumnSummerSpring
Daily radon concentration
Day Evening Day
Dawn
Precautions when using
Example of proper installation
· please, let the device where there is no ventilation
environment to check the area's usual radon status.
Prohibited
· Install at least 50cm apart from wall, window and floor.
· In general, proper places to install are on desk, table
in the living room, or on dining table in the kitchen.
Caution
1. For accurate measurement, close windows and doors tightly.
2. When RadonEye + is connected to DC 12V adaptor, measurement
starts automatically.
3. After the power is on, the wait time (10 minutes) is indicated by ‘- -’.
When wait time is over, the measured values are displayed from
10 minutes later. Measurements are displayed in 10 minute interval,
and saved in 1 hour interval.
To start the device
RADONEYE +
C_device
P_device
Measured value
12h 24h36h
Actual value
1h
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Precautions before using App.
This is the User's Manual for controlling RadonEye + device made in
Radon FTLab. Please refer to the detailed manual on the Radon FTLab
website (http://RadonFTLab.com) for the equipment and PC program
manual.
• Since it is an application that operates on a Wi-Fi base, there may be
operational limitations.
• It works properly in Android 4.3 version or iOS 8.0 version or later
• If the distance between the device and the smart device increases,
the
connection may be lost.
• In the 5G Internet environment, there are restrictions in the use of the
product, so please use 2.4G.
• We recommend user to agree to the privacy policy during the app
setting stage for trouble-free data transfer.
• Bluetooth and GPS must be enabled before using
• The time in the area where the equipment is installed is applied to the
data recorded after app setting/direct connection. The factory
Bluetooth & GPS function of
mobile device should be
activated for
RadonEye + setting
GPS
Bluetooth
RadonEye +
RadonEye + is the world's first IoT smart radon detector that is used in connec-
tion with web database based on WiFi. Therefore, RadonEye + is suitable for
real-time radon monitoring and easy to create Real-Time Radon Map. Manufac-
turer, Radon FTLab provides web database, radon-net.com, which means the
user can access the data every time, everywhere by smart phone, tablet or
internet connected desktop PC.
The sensitivity performance of RadonEye + is like a standard instrument. It is 20
times higher when it is compared with other general customer’s radon detector,
so the measurement data is fast and precise. Radon measurement data can be
recorded within 1 hour with below
±
10% error from starting time of measurement
and the data will be updated every 10 minutes so the user will get to know the
diminishing trend of indoor radon level just within 30 minutes by ventilation or
window open.
RadonEye + has added temperature & humidity sensor and measurement time
recording and extended the measurement range to 255pCi / l.
RadonEye + offers free web uploading service at least 2 years.
Measurement
Range
Precision
Accuracy
Data log
Display
Mobile control
Sensing factor
Time checking
Web access
Mobile notification
WiFi, Bluetooth
Radon,Humidity,Temperature
O
O
O
0.1~255 pCi/l
(1 ~9,435 Bq/㎥)
Model RadonEye (RD200) RadonEye + (RD200P2)
Bluetooth
Radon
X
X
X
0.1~100 pCi/l
(1 ~3,700 Bq/㎥)
< ±10%at 10pCi/l (370Bq/㎥)
< ±10%(min. error <±0.5pCi/l)
max1year(1hour interval)
0.96 inch OLED
< RadonEye VS RadonEye + >
1. What should I do under condition of no Wi-Fi around available?
A : RadonEye Plus2 automatically starts measuring when power is simply connected, so all you need to do is just select 'Connected Devices'
menu in your smartphone application even if you don't have a Wi-Fi
2. Tell me how to set up an app. when errors.
2.1. RadonEye Plus2 you are trying to set is not on the list.
A (iPhone) : Switch Bluetooth off and on to update the list again.
A (Android) : Click the "Rescan" button to update the list again.
2.2. The Wi-Fi list displayed on the app. does not contain the desired Wi-Fi I’d like to connect to.
A : Click the ‘refresh’ icon to update the Wi-Fi list. for your reference, 5GHz Wi-Fi is not supported and will not appear in the list.
2.3. If 'Wi-Fi settings failed' is displayed when next button is clicked after entering the Wi-Fi information.
A : If the green LED on RadonEye Plus2 keeps blinking and Wi-Fi connection is not successful, please check if Wi-Fi password is entered
correctly and internet connection status of the Router.
2.4. If the message 'RadonEye Plus2 registration failed' is displayed when the button is clicked after entering the Wi-Fi information,
A : Smartphone should also be Internet-connected through Wi-Fi / LTE / 3G
Check the Internet connection status of the smart device and proceed with setting under this circumstance.
2.5. If other cases of setting failure
A : Check the Wi-Fi and GPS connection on your smartphone, then turn the device off and on and run.
3. How can I change RadonEye Plus2 wifi connection that’s been already set into previous wifi place?
A : If you have Wi-Fi in your environment, you can set it up again and use it easily by clicking ‘Main’-‘Sub Menu’-‘Network’
4. It continues to show the high concentration figure, Is it out of order?
A : In this case, leave it in a well ventilated location for about two days and try to measure the low concentration at veranda, indoor air quality,
and high concentration in sequence
Q&A
RADON NET
RadonEye + provides Remote Radon Monitoring Network Service. You can
check radon value in the web browser by registering the registration key which
is given when you access the radon-net.com website when setting the app.
You can also check the local radon value at any time through Radon Map.
· My Devices
· Information
· Device Location
· Device Log (Graph)
· Radon Map
Sign In
Guest
Email
RADON NET
Password
Good
Normal
Warning
Bad
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
Smart Radon Gas Monitor
RADONEYE +
Operation Manual
RD200P2
•Type : pulsed ion chamber
•First reliable data out : < 60min
•Data interval : 10min update (60min moving average)
•Sensitivity : 0.5cpm/pCi/l at 10pCi/l (30cph/pCi/l)
•Operating range : 10℃ ~ 40℃ (50°F ~ 100°F), RH < 80%
•Measurement range : 0.1 ~ 255 pCi/l (9,435 Bq/㎥)
* Environment reference value 4pCi/l (148 Bq/㎥)
•Precision : < ±10% at 10pCi/l
•Accuracy : < ±10% (min. error <±0.5pCi/l ) at 10pCi/l
•Interval of measurement value saving : 60 minutes
•Storage capacity : 1 year
•Power consumption : DC12 ± 0.1V, 0.1A ( Use 12V DC adapter)
•Size : Φ80(mm) x 120(mm)
•Display : 0.96 inch OLED
•Data communication : Wi-Fi (internet), Bluetooth
•Weight : 520g
•Altitude : Up to 2000 m
•pollution degree : 2
* Radon Eye Plus 2 is a function upgraded version of Radon Eye Plus that enhances
Wi-Fi setup convenience by adding BLE communication to previous Radon Eye Plus
products.
* In March 2019, the model name of RadonEye Plus2 changes from RD200P to
RD200P2.
Product Specifications
Descriptive labeling in accordance with Quality
Management and Safety Control Act for Industrial Goods.
Instrument type: RD200P2
Instrument name : RADONEYE +
Kind : For home(indoor) use
Material : ABS
Manufactured date : Indicated separately
Manufacturer : FTLab
* Only the manufacturer or agency will inspect and supply
Country of manufacture : Republic of Korea
Questions : www.radonftlab.com
FTLAB succeeded in developing a real-time Radon
sensor in 2015, and also succeeded in mass production
in 2016, we launched RADON FTLAB.
COPYRIGHT (C)FTLAB Co., Ltd ALL RIGHT RESREVED.
503ho, 8, 330beon-gil,
Haebong-ro, Danwon-gu,
Ansan-si, Gyeonggi-do, Korea
FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
① BLE access : Indicates it is connected with smartphone using BLE communication
② Shock detect sign : It appears when a shock or vibration from outside is sensed, and
the measurement stops at the time
③ Radon concentration : Measured value of Radon shown in 10 minute interval
④ Unit of measure : Shown in pCi/l or Bq/㎥. Unit can be changed by smartphone app.
⑤ Information display : SN, peak value, 1/2/7 day and month average, measurement time,
pulse count per 10 minute measurement (present value/last value)
Name and function of each part
BLE Access
Shock detection
Radon concentration
Unit
Information
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Name and function of each part
Front
LED : Red LED flashes for 30 seconds when Radon value exceeds
reference value.
Green LED flashes when Wi-Fi connection is not normal.
Ventilation window
LCD : Information display window for Wi-Fi access, shock detection,
Radon concentration, etc.
Rear
Power
12V DC
Radon ?
1. Radon is a colorless, odorless and tasteless radioactive gas.
Radon, a gas originating from radium which is generated by the collapse of
uranium in soil, is everywhere on earth. It penetrates indoors mainly from the
ground or building materials. The gases that cause sick house syndrome and
other noxious gases luckily smell. Urban gas and LPG were deliberately
smelled. However, radon does not smell nor can be seen. And no matter how
many years have passed, it is constantly released from the wall, ceiling and
floor.
2. Radon is 8 times heavier than air and is easily concentrated in the house.
Radon has the half-life of 3.8 days and makes alpha decay. The alpha particle
emitted from radon has the smallest penetration power among the radiation
rays and can not penetrate even a single piece of paper, but its destructive
power is so great that the cells are damaged if they are directly impacted by
radon, even having a nickname of "silent murderer". This is why radon detec-
tion sensor is absolutely needed in home.
3. Radon gas causes lung cancer.
Three causes of modern female lung cancer are passive smoking, ultrafine
particles and radon. When radon gas enters the lung through breathing, alpha
particles released from radon damage the lung cells. Since once destroyed
lung cells are not regenerated, prolonged exposure to high concentration of
radon gas will increase the likelihood of lung cancer. Therefore, the United
States Environmental Protection Agency(EPA) designated Radon as a must
be managed hazardous gas for healthy life.
- Accurate measurement value of the average radon level can be obtained when
the house is empty for 1 or 2 days.
- Reliable value can be obtained about 1 hour after start of the measurement.
- Radon concentration in the house is generally high at dawn and low at daytime,
so continuous measurement for more than 24 hours is necessary.
Precautions
•Please, Measure in an environment free from vibration.
•Shock or disassembly will cause the equipment to malfunction and will not
be included in the warranty. (the unit will display “ERR” message)
•Abnormal data can be measured when using near a strong electromagnetic
radiation source such as high voltage transmission line, subway line, Wifi
transmitter(1Meter or less), microwave oven(1M or less) ('OVER'
message)
•Use only indoors. No waterproof.
•Use the provided DC 12V adapter.
•Continuous use in an environment with relative humidity of 80% or
higher is prohibited.
•A warning message may be sent to the set mobile device when it is higher
than the set radon concentration.
•Proper operating temperature range is 10℃ ~ 40℃ (50°F ~ 100°F)
•The warranty period is one year after purchase.
<Radon concentration fluctuation graph>
Seasonal radon concentration
WinterAutumnSummerSpring
Daily radon concentration
Day Evening Day
Dawn
Precautions when using
Example of proper installation
· please, let the device where there is no ventilation
environment to check the area's usual radon status.
Prohibited
· Install at least 50cm apart from wall, window and floor.
· In general, proper places to install are on desk, table
in the living room, or on dining table in the kitchen.
Caution
1. For accurate measurement, close windows and doors tightly.
2. When RadonEye + is connected to DC 12V adaptor, measurement
starts automatically.
3. After the power is on, the wait time (10 minutes) is indicated by ‘- -’.
When wait time is over, the measured values are displayed from
10 minutes later. Measurements are displayed in 10 minute interval,
and saved in 1 hour interval.
To start the device
RADONEYE +
C_device
P_device
Measured value
12h 24h36h
Actual value
1h
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Precautions before using App.
This is the User's Manual for controlling RadonEye + device made in
Radon FTLab. Please refer to the detailed manual on the Radon FTLab
website (http://RadonFTLab.com) for the equipment and PC program
manual.
• Since it is an application that operates on a Wi-Fi base, there may be
operational limitations.
• It works properly in Android 4.3 version or iOS 8.0 version or later
• If the distance between the device and the smart device increases,
the
connection may be lost.
• In the 5G Internet environment, there are restrictions in the use of the
product, so please use 2.4G.
• We recommend user to agree to the privacy policy during the app
setting stage for trouble-free data transfer.
• Bluetooth and GPS must be enabled before using
• The time in the area where the equipment is installed is applied to the
data recorded after app setting/direct connection. The factory
Bluetooth & GPS function of
mobile device should be
activated for
RadonEye + setting
GPS
Bluetooth
RadonEye +
RadonEye + is the world's first IoT smart radon detector that is used in connec-
tion with web database based on WiFi. Therefore, RadonEye + is suitable for
real-time radon monitoring and easy to create Real-Time Radon Map. Manufac-
turer, Radon FTLab provides web database, radon-net.com, which means the
user can access the data every time, everywhere by smart phone, tablet or
internet connected desktop PC.
The sensitivity performance of RadonEye + is like a standard instrument. It is 20
times higher when it is compared with other general customer’s radon detector,
so the measurement data is fast and precise. Radon measurement data can be
recorded within 1 hour with below
±
10% error from starting time of measurement
and the data will be updated every 10 minutes so the user will get to know the
diminishing trend of indoor radon level just within 30 minutes by ventilation or
window open.
RadonEye + has added temperature & humidity sensor and measurement time
recording and extended the measurement range to 255pCi / l.
RadonEye + offers free web uploading service at least 2 years.
Measurement
Range
Precision
Accuracy
Data log
Display
Mobile control
Sensing factor
Time checking
Web access
Mobile notification
WiFi, Bluetooth
Radon,Humidity,Temperature
O
O
O
0.1~255 pCi/l
(1 ~9,435 Bq/㎥)
Model RadonEye (RD200) RadonEye + (RD200P2)
Bluetooth
Radon
X
X
X
0.1~100 pCi/l
(1 ~3,700 Bq/㎥)
< ±10%at 10pCi/l (370Bq/㎥)
< ±10%(min. error <±0.5pCi/l)
max1year(1hour interval)
0.96 inch OLED
< RadonEye VS RadonEye + >
1. What should I do under condition of no Wi-Fi around available?
A : RadonEye Plus2 automatically starts measuring when power is simply connected, so all you need to do is just select 'Connected Devices'
menu in your smartphone application even if you don't have a Wi-Fi
2. Tell me how to set up an app. when errors.
2.1. RadonEye Plus2 you are trying to set is not on the list.
A (iPhone) : Switch Bluetooth off and on to update the list again.
A (Android) : Click the "Rescan" button to update the list again.
2.2. The Wi-Fi list displayed on the app. does not contain the desired Wi-Fi I’d like to connect to.
A : Click the ‘refresh’ icon to update the Wi-Fi list. for your reference, 5GHz Wi-Fi is not supported and will not appear in the list.
2.3. If 'Wi-Fi settings failed' is displayed when next button is clicked after entering the Wi-Fi information.
A : If the green LED on RadonEye Plus2 keeps blinking and Wi-Fi connection is not successful, please check if Wi-Fi password is entered
correctly and internet connection status of the Router.
2.4. If the message 'RadonEye Plus2 registration failed' is displayed when the button is clicked after entering the Wi-Fi information,
A : Smartphone should also be Internet-connected through Wi-Fi / LTE / 3G
Check the Internet connection status of the smart device and proceed with setting under this circumstance.
2.5. If other cases of setting failure
A : Check the Wi-Fi and GPS connection on your smartphone, then turn the device off and on and run.
3. How can I change RadonEye Plus2 wifi connection that’s been already set into previous wifi place?
A : If you have Wi-Fi in your environment, you can set it up again and use it easily by clicking ‘Main’-‘Sub Menu’-‘Network’
4. It continues to show the high concentration figure, Is it out of order?
A : In this case, leave it in a well ventilated location for about two days and try to measure the low concentration at veranda, indoor air quality,
and high concentration in sequence
Q&A
RADON NET
RadonEye + provides Remote Radon Monitoring Network Service. You can
check radon value in the web browser by registering the registration key which
is given when you access the radon-net.com website when setting the app.
You can also check the local radon value at any time through Radon Map.
· My Devices
· Information
· Device Location
· Device Log (Graph)
· Radon Map
Sign In
Guest
Email
RADON NET
Password
Good
Normal
Warning
Bad
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
Smart Radon Gas Monitor
RADONEYE +
Operation Manual
RD200P2
•Type : pulsed ion chamber
•First reliable data out : < 60min
•Data interval : 10min update (60min moving average)
•Sensitivity : 0.5cpm/pCi/l at 10pCi/l (30cph/pCi/l)
•Operating range : 10℃ ~ 40℃ (50°F ~ 100°F), RH < 80%
•Measurement range : 0.1 ~ 255 pCi/l (9,435 Bq/㎥)
* Environment reference value 4pCi/l (148 Bq/㎥)
•Precision : < ±10% at 10pCi/l
•Accuracy : < ±10% (min. error <±0.5pCi/l ) at 10pCi/l
•Interval of measurement value saving : 60 minutes
•Storage capacity : 1 year
•Power consumption : DC12 ± 0.1V, 0.1A ( Use 12V DC adapter)
•Size : Φ80(mm) x 120(mm)
•Display : 0.96 inch OLED
•Data communication : Wi-Fi (internet), Bluetooth
•Weight : 520g
•Altitude : Up to 2000 m
•pollution degree : 2
* Radon Eye Plus 2 is a function upgraded version of Radon Eye Plus that enhances
Wi-Fi setup convenience by adding BLE communication to previous Radon Eye Plus
products.
* In March 2019, the model name of RadonEye Plus2 changes from RD200P to
RD200P2.
Product Specifications
Descriptive labeling in accordance with Quality
Management and Safety Control Act for Industrial Goods.
Instrument type: RD200P2
Instrument name : RADONEYE +
Kind : For home(indoor) use
Material : ABS
Manufactured date : Indicated separately
Manufacturer : FTLab
* Only the manufacturer or agency will inspect and supply
Country of manufacture : Republic of Korea
Questions : www.radonftlab.com
FTLAB succeeded in developing a real-time Radon
sensor in 2015, and also succeeded in mass production
in 2016, we launched RADON FTLAB.
COPYRIGHT (C)FTLAB Co., Ltd ALL RIGHT RESREVED.
503ho, 8, 330beon-gil,
Haebong-ro, Danwon-gu,
Ansan-si, Gyeonggi-do, Korea
FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
① BLE access : Indicates it is connected with smartphone using BLE communication
② Shock detect sign : It appears when a shock or vibration from outside is sensed, and
the measurement stops at the time
③ Radon concentration : Measured value of Radon shown in 10 minute interval
④ Unit of measure : Shown in pCi/l or Bq/㎥. Unit can be changed by smartphone app.
⑤ Information display : SN, peak value, 1/2/7 day and month average, measurement time,
pulse count per 10 minute measurement (present value/last value)
Name and function of each part
BLE Access
Shock detection
Radon concentration
Unit
Information
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Name and function of each part
Front
LED : Red LED flashes for 30 seconds when Radon value exceeds
reference value.
Green LED flashes when Wi-Fi connection is not normal.
Ventilation window
LCD : Information display window for Wi-Fi access, shock detection,
Radon concentration, etc.
Rear
Power
12V DC
Radon ?
1. Radon is a colorless, odorless and tasteless radioactive gas.
Radon, a gas originating from radium which is generated by the collapse of
uranium in soil, is everywhere on earth. It penetrates indoors mainly from the
ground or building materials. The gases that cause sick house syndrome and
other noxious gases luckily smell. Urban gas and LPG were deliberately
smelled. However, radon does not smell nor can be seen. And no matter how
many years have passed, it is constantly released from the wall, ceiling and
floor.
2. Radon is 8 times heavier than air and is easily concentrated in the house.
Radon has the half-life of 3.8 days and makes alpha decay. The alpha particle
emitted from radon has the smallest penetration power among the radiation
rays and can not penetrate even a single piece of paper, but its destructive
power is so great that the cells are damaged if they are directly impacted by
radon, even having a nickname of "silent murderer". This is why radon detec-
tion sensor is absolutely needed in home.
3. Radon gas causes lung cancer.
Three causes of modern female lung cancer are passive smoking, ultrafine
particles and radon. When radon gas enters the lung through breathing, alpha
particles released from radon damage the lung cells. Since once destroyed
lung cells are not regenerated, prolonged exposure to high concentration of
radon gas will increase the likelihood of lung cancer. Therefore, the United
States Environmental Protection Agency(EPA) designated Radon as a must
be managed hazardous gas for healthy life.
- Accurate measurement value of the average radon level can be obtained when
the house is empty for 1 or 2 days.
- Reliable value can be obtained about 1 hour after start of the measurement.
- Radon concentration in the house is generally high at dawn and low at daytime,
so continuous measurement for more than 24 hours is necessary.
Precautions
•Please, Measure in an environment free from vibration.
•Shock or disassembly will cause the equipment to malfunction and will not
be included in the warranty. (the unit will display “ERR” message)
•Abnormal data can be measured when using near a strong electromagnetic
radiation source such as high voltage transmission line, subway line, Wifi
transmitter(1Meter or less), microwave oven(1M or less) ('OVER'
message)
•Use only indoors. No waterproof.
•Use the provided DC 12V adapter.
•Continuous use in an environment with relative humidity of 80% or
higher is prohibited.
•A warning message may be sent to the set mobile device when it is higher
than the set radon concentration.
•Proper operating temperature range is 10℃ ~ 40℃ (50°F ~ 100°F)
•The warranty period is one year after purchase.
<Radon concentration fluctuation graph>
Seasonal radon concentration
WinterAutumnSummerSpring
Daily radon concentration
Day Evening Day
Dawn
Precautions when using
Example of proper installation
· please, let the device where there is no ventilation
environment to check the area's usual radon status.
Prohibited
· Install at least 50cm apart from wall, window and floor.
· In general, proper places to install are on desk, table
in the living room, or on dining table in the kitchen.
Caution
1. For accurate measurement, close windows and doors tightly.
2. When RadonEye + is connected to DC 12V adaptor, measurement
starts automatically.
3. After the power is on, the wait time (10 minutes) is indicated by ‘- -’.
When wait time is over, the measured values are displayed from
10 minutes later. Measurements are displayed in 10 minute interval,
and saved in 1 hour interval.
To start the device
RADONEYE +
C_device
P_device
Measured value
12h 24h36h
Actual value
1h
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Precautions before using App.
This is the User's Manual for controlling RadonEye + device made in
Radon FTLab. Please refer to the detailed manual on the Radon FTLab
website (http://RadonFTLab.com) for the equipment and PC program
manual.
• Since it is an application that operates on a Wi-Fi base, there may be
operational limitations.
• It works properly in Android 4.3 version or iOS 8.0 version or later
• If the distance between the device and the smart device increases,
the
connection may be lost.
• In the 5G Internet environment, there are restrictions in the use of the
product, so please use 2.4G.
• We recommend user to agree to the privacy policy during the app
setting stage for trouble-free data transfer.
• Bluetooth and GPS must be enabled before using
• The time in the area where the equipment is installed is applied to the
data recorded after app setting/direct connection. The factory
Bluetooth & GPS function of
mobile device should be
activated for
RadonEye + setting
GPS
Bluetooth
RadonEye +
RadonEye + is the world's first IoT smart radon detector that is used in connec-
tion with web database based on WiFi. Therefore, RadonEye + is suitable for
real-time radon monitoring and easy to create Real-Time Radon Map. Manufac-
turer, Radon FTLab provides web database, radon-net.com, which means the
user can access the data every time, everywhere by smart phone, tablet or
internet connected desktop PC.
The sensitivity performance of RadonEye + is like a standard instrument. It is 20
times higher when it is compared with other general customer’s radon detector,
so the measurement data is fast and precise. Radon measurement data can be
recorded within 1 hour with below
±
10% error from starting time of measurement
and the data will be updated every 10 minutes so the user will get to know the
diminishing trend of indoor radon level just within 30 minutes by ventilation or
window open.
RadonEye + has added temperature & humidity sensor and measurement time
recording and extended the measurement range to 255pCi / l.
RadonEye + offers free web uploading service at least 2 years.
Measurement
Range
Precision
Accuracy
Data log
Display
Mobile control
Sensing factor
Time checking
Web access
Mobile notification
WiFi, Bluetooth
Radon,Humidity,Temperature
O
O
O
0.1~255 pCi/l
(1 ~9,435 Bq/㎥)
Model RadonEye (RD200) RadonEye + (RD200P2)
Bluetooth
Radon
X
X
X
0.1~100 pCi/l
(1 ~3,700 Bq/㎥)
< ±10%at 10pCi/l (370Bq/㎥)
< ±10%(min. error <±0.5pCi/l)
max1year(1hour interval)
0.96 inch OLED
< RadonEye VS RadonEye + >
1. What should I do under condition of no Wi-Fi around available?
A : RadonEye Plus2 automatically starts measuring when power is simply connected, so all you need to do is just select 'Connected Devices'
menu in your smartphone application even if you don't have a Wi-Fi
2. Tell me how to set up an app. when errors.
2.1. RadonEye Plus2 you are trying to set is not on the list.
A (iPhone) : Switch Bluetooth off and on to update the list again.
A (Android) : Click the "Rescan" button to update the list again.
2.2. The Wi-Fi list displayed on the app. does not contain the desired Wi-Fi I’d like to connect to.
A : Click the ‘refresh’ icon to update the Wi-Fi list. for your reference, 5GHz Wi-Fi is not supported and will not appear in the list.
2.3. If 'Wi-Fi settings failed' is displayed when next button is clicked after entering the Wi-Fi information.
A : If the green LED on RadonEye Plus2 keeps blinking and Wi-Fi connection is not successful, please check if Wi-Fi password is entered
correctly and internet connection status of the Router.
2.4. If the message 'RadonEye Plus2 registration failed' is displayed when the button is clicked after entering the Wi-Fi information,
A : Smartphone should also be Internet-connected through Wi-Fi / LTE / 3G
Check the Internet connection status of the smart device and proceed with setting under this circumstance.
2.5. If other cases of setting failure
A : Check the Wi-Fi and GPS connection on your smartphone, then turn the device off and on and run.
3. How can I change RadonEye Plus2 wifi connection that’s been already set into previous wifi place?
A : If you have Wi-Fi in your environment, you can set it up again and use it easily by clicking ‘Main’-‘Sub Menu’-‘Network’
4. It continues to show the high concentration figure, Is it out of order?
A : In this case, leave it in a well ventilated location for about two days and try to measure the low concentration at veranda, indoor air quality,
and high concentration in sequence
Q&A
RADON NET
RadonEye + provides Remote Radon Monitoring Network Service. You can
check radon value in the web browser by registering the registration key which
is given when you access the radon-net.com website when setting the app.
You can also check the local radon value at any time through Radon Map.
· My Devices
· Information
· Device Location
· Device Log (Graph)
· Radon Map
Sign In
Guest
Email
RADON NET
Password
Good
Normal
Warning
Bad
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
Smart Radon Gas Monitor
RADONEYE +
Operation Manual
RD200P2
•Type : pulsed ion chamber
•First reliable data out : < 60min
•Data interval : 10min update (60min moving average)
•Sensitivity : 0.5cpm/pCi/l at 10pCi/l (30cph/pCi/l)
•Operating range : 10℃ ~ 40℃ (50°F ~ 100°F), RH < 80%
•Measurement range : 0.1 ~ 255 pCi/l (9,435 Bq/㎥)
* Environment reference value 4pCi/l (148 Bq/㎥)
•Precision : < ±10% at 10pCi/l
•Accuracy : < ±10% (min. error <±0.5pCi/l ) at 10pCi/l
•Interval of measurement value saving : 60 minutes
•Storage capacity : 1 year
•Power consumption : DC12 ± 0.1V, 0.1A ( Use 12V DC adapter)
•Size : Φ80(mm) x 120(mm)
•Display : 0.96 inch OLED
•Data communication : Wi-Fi (internet), Bluetooth
•Weight : 520g
•Altitude : Up to 2000 m
•pollution degree : 2
* Radon Eye Plus 2 is a function upgraded version of Radon Eye Plus that enhances
Wi-Fi setup convenience by adding BLE communication to previous Radon Eye Plus
products.
* In March 2019, the model name of RadonEye Plus2 changes from RD200P to
RD200P2.
Product Specifications
Descriptive labeling in accordance with Quality
Management and Safety Control Act for Industrial Goods.
Instrument type: RD200P2
Instrument name : RADONEYE +
Kind : For home(indoor) use
Material : ABS
Manufactured date : Indicated separately
Manufacturer : FTLab
* Only the manufacturer or agency will inspect and supply
Country of manufacture : Republic of Korea
Questions : www.radonftlab.com
FTLAB succeeded in developing a real-time Radon
sensor in 2015, and also succeeded in mass production
in 2016, we launched RADON FTLAB.
COPYRIGHT (C)FTLAB Co., Ltd ALL RIGHT RESREVED.
503ho, 8, 330beon-gil,
Haebong-ro, Danwon-gu,
Ansan-si, Gyeonggi-do, Korea
FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
① BLE access : Indicates it is connected with smartphone using BLE communication
② Shock detect sign : It appears when a shock or vibration from outside is sensed, and
the measurement stops at the time
③ Radon concentration : Measured value of Radon shown in 10 minute interval
④ Unit of measure : Shown in pCi/l or Bq/㎥. Unit can be changed by smartphone app.
⑤ Information display : SN, peak value, 1/2/7 day and month average, measurement time,
pulse count per 10 minute measurement (present value/last value)
Name and function of each part
BLE Access
Shock detection
Radon concentration
Unit
Information
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Name and function of each part
Front
LED : Red LED flashes for 30 seconds when Radon value exceeds
reference value.
Green LED flashes when Wi-Fi connection is not normal.
Ventilation window
LCD : Information display window for Wi-Fi access, shock detection,
Radon concentration, etc.
Rear
Power
12V DC
Radon ?
1. Radon is a colorless, odorless and tasteless radioactive gas.
Radon, a gas originating from radium which is generated by the collapse of
uranium in soil, is everywhere on earth. It penetrates indoors mainly from the
ground or building materials. The gases that cause sick house syndrome and
other noxious gases luckily smell. Urban gas and LPG were deliberately
smelled. However, radon does not smell nor can be seen. And no matter how
many years have passed, it is constantly released from the wall, ceiling and
floor.
2. Radon is 8 times heavier than air and is easily concentrated in the house.
Radon has the half-life of 3.8 days and makes alpha decay. The alpha particle
emitted from radon has the smallest penetration power among the radiation
rays and can not penetrate even a single piece of paper, but its destructive
power is so great that the cells are damaged if they are directly impacted by
radon, even having a nickname of "silent murderer". This is why radon detec-
tion sensor is absolutely needed in home.
3. Radon gas causes lung cancer.
Three causes of modern female lung cancer are passive smoking, ultrafine
particles and radon. When radon gas enters the lung through breathing, alpha
particles released from radon damage the lung cells. Since once destroyed
lung cells are not regenerated, prolonged exposure to high concentration of
radon gas will increase the likelihood of lung cancer. Therefore, the United
States Environmental Protection Agency(EPA) designated Radon as a must
be managed hazardous gas for healthy life.
- Accurate measurement value of the average radon level can be obtained when
the house is empty for 1 or 2 days.
- Reliable value can be obtained about 1 hour after start of the measurement.
- Radon concentration in the house is generally high at dawn and low at daytime,
so continuous measurement for more than 24 hours is necessary.
Precautions
•Please, Measure in an environment free from vibration.
•Shock or disassembly will cause the equipment to malfunction and will not
be included in the warranty. (the unit will display “ERR” message)
•Abnormal data can be measured when using near a strong electromagnetic
radiation source such as high voltage transmission line, subway line, Wifi
transmitter(1Meter or less), microwave oven(1M or less) ('OVER'
message)
•Use only indoors. No waterproof.
•Use the provided DC 12V adapter.
•Continuous use in an environment with relative humidity of 80% or
higher is prohibited.
•A warning message may be sent to the set mobile device when it is higher
than the set radon concentration.
•Proper operating temperature range is 10℃ ~ 40℃ (50°F ~ 100°F)
•The warranty period is one year after purchase.
<Radon concentration fluctuation graph>
Seasonal radon concentration
WinterAutumnSummerSpring
Daily radon concentration
Day Evening Day
Dawn
Precautions when using
Example of proper installation
· please, let the device where there is no ventilation
environment to check the area's usual radon status.
Prohibited
· Install at least 50cm apart from wall, window and floor.
· In general, proper places to install are on desk, table
in the living room, or on dining table in the kitchen.
Caution
1. For accurate measurement, close windows and doors tightly.
2. When RadonEye + is connected to DC 12V adaptor, measurement
starts automatically.
3. After the power is on, the wait time (10 minutes) is indicated by ‘- -’.
When wait time is over, the measured values are displayed from
10 minutes later. Measurements are displayed in 10 minute interval,
and saved in 1 hour interval.
To start the device
RADONEYE +
C_device
P_device
Measured value
12h 24h36h
Actual value
1h
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Precautions before using App.
This is the User's Manual for controlling RadonEye + device made in
Radon FTLab. Please refer to the detailed manual on the Radon FTLab
website (http://RadonFTLab.com) for the equipment and PC program
manual.
• Since it is an application that operates on a Wi-Fi base, there may be
operational limitations.
• It works properly in Android 4.3 version or iOS 8.0 version or later
• If the distance between the device and the smart device increases,
the
connection may be lost.
• In the 5G Internet environment, there are restrictions in the use of the
product, so please use 2.4G.
• We recommend user to agree to the privacy policy during the app
setting stage for trouble-free data transfer.
• Bluetooth and GPS must be enabled before using
• The time in the area where the equipment is installed is applied to the
data recorded after app setting/direct connection. The factory
Bluetooth & GPS function of
mobile device should be
activated for
RadonEye + setting
GPS
Bluetooth
RadonEye +
RadonEye + is the world's first IoT smart radon detector that is used in connec-
tion with web database based on WiFi. Therefore, RadonEye + is suitable for
real-time radon monitoring and easy to create Real-Time Radon Map. Manufac-
turer, Radon FTLab provides web database, radon-net.com, which means the
user can access the data every time, everywhere by smart phone, tablet or
internet connected desktop PC.
The sensitivity performance of RadonEye + is like a standard instrument. It is 20
times higher when it is compared with other general customer’s radon detector,
so the measurement data is fast and precise. Radon measurement data can be
recorded within 1 hour with below
±
10% error from starting time of measurement
and the data will be updated every 10 minutes so the user will get to know the
diminishing trend of indoor radon level just within 30 minutes by ventilation or
window open.
RadonEye + has added temperature & humidity sensor and measurement time
recording and extended the measurement range to 255pCi / l.
RadonEye + offers free web uploading service at least 2 years.
Measurement
Range
Precision
Accuracy
Data log
Display
Mobile control
Sensing factor
Time checking
Web access
Mobile notification
WiFi, Bluetooth
Radon,Humidity,Temperature
O
O
O
0.1~255 pCi/l
(1 ~9,435 Bq/㎥)
Model RadonEye (RD200) RadonEye + (RD200P2)
Bluetooth
Radon
X
X
X
0.1~100 pCi/l
(1 ~3,700 Bq/㎥)
< ±10%at 10pCi/l (370Bq/㎥)
< ±10%(min. error <±0.5pCi/l)
max1year(1hour interval)
0.96 inch OLED
< RadonEye VS RadonEye + >
1. What should I do under condition of no Wi-Fi around available?
A : RadonEye Plus2 automatically starts measuring when power is simply connected, so all you need to do is just select 'Connected Devices'
menu in your smartphone application even if you don't have a Wi-Fi
2. Tell me how to set up an app. when errors.
2.1. RadonEye Plus2 you are trying to set is not on the list.
A (iPhone) : Switch Bluetooth off and on to update the list again.
A (Android) : Click the "Rescan" button to update the list again.
2.2. The Wi-Fi list displayed on the app. does not contain the desired Wi-Fi I’d like to connect to.
A : Click the ‘refresh’ icon to update the Wi-Fi list. for your reference, 5GHz Wi-Fi is not supported and will not appear in the list.
2.3. If 'Wi-Fi settings failed' is displayed when next button is clicked after entering the Wi-Fi information.
A : If the green LED on RadonEye Plus2 keeps blinking and Wi-Fi connection is not successful, please check if Wi-Fi password is entered
correctly and internet connection status of the Router.
2.4. If the message 'RadonEye Plus2 registration failed' is displayed when the button is clicked after entering the Wi-Fi information,
A : Smartphone should also be Internet-connected through Wi-Fi / LTE / 3G
Check the Internet connection status of the smart device and proceed with setting under this circumstance.
2.5. If other cases of setting failure
A : Check the Wi-Fi and GPS connection on your smartphone, then turn the device off and on and run.
3. How can I change RadonEye Plus2 wifi connection that’s been already set into previous wifi place?
A : If you have Wi-Fi in your environment, you can set it up again and use it easily by clicking ‘Main’-‘Sub Menu’-‘Network’
4. It continues to show the high concentration figure, Is it out of order?
A : In this case, leave it in a well ventilated location for about two days and try to measure the low concentration at veranda, indoor air quality,
and high concentration in sequence
Q&A
RADON NET
RadonEye + provides Remote Radon Monitoring Network Service. You can
check radon value in the web browser by registering the registration key which
is given when you access the radon-net.com website when setting the app.
You can also check the local radon value at any time through Radon Map.
· My Devices
· Information
· Device Location
· Device Log (Graph)
· Radon Map
Sign In
Guest
Email
RADON NET
Password
Good
Normal
Warning
Bad
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
Smart Radon Gas Monitor
RADONEYE +
Operation Manual
RD200P2
•Type : pulsed ion chamber
•First reliable data out : < 60min
•Data interval : 10min update (60min moving average)
•Sensitivity : 0.5cpm/pCi/l at 10pCi/l (30cph/pCi/l)
•Operating range : 10℃ ~ 40℃ (50°F ~ 100°F), RH < 80%
•Measurement range : 0.1 ~ 255 pCi/l (9,435 Bq/㎥)
* Environment reference value 4pCi/l (148 Bq/㎥)
•Precision : < ±10% at 10pCi/l
•Accuracy : < ±10% (min. error <±0.5pCi/l ) at 10pCi/l
•Interval of measurement value saving : 60 minutes
•Storage capacity : 1 year
•Power consumption : DC12 ± 0.1V, 0.1A ( Use 12V DC adapter)
•Size : Φ80(mm) x 120(mm)
•Display : 0.96 inch OLED
•Data communication : Wi-Fi (internet), Bluetooth
•Weight : 520g
•Altitude : Up to 2000 m
•pollution degree : 2
* Radon Eye Plus 2 is a function upgraded version of Radon Eye Plus that enhances
Wi-Fi setup convenience by adding BLE communication to previous Radon Eye Plus
products.
* In March 2019, the model name of RadonEye Plus2 changes from RD200P to
RD200P2.
Product Specifications
Descriptive labeling in accordance with Quality
Management and Safety Control Act for Industrial Goods.
Instrument type: RD200P2
Instrument name : RADONEYE +
Kind : For home(indoor) use
Material : ABS
Manufactured date : Indicated separately
Manufacturer : FTLab
* Only the manufacturer or agency will inspect and supply
Country of manufacture : Republic of Korea
Questions : www.radonftlab.com
FTLAB succeeded in developing a real-time Radon
sensor in 2015, and also succeeded in mass production
in 2016, we launched RADON FTLAB.
COPYRIGHT (C)FTLAB Co., Ltd ALL RIGHT RESREVED.
503ho, 8, 330beon-gil,
Haebong-ro, Danwon-gu,
Ansan-si, Gyeonggi-do, Korea
FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P
① BLE access : Indicates it is connected with smartphone using BLE communication
② Shock detect sign : It appears when a shock or vibration from outside is sensed, and
the measurement stops at the time
③ Radon concentration : Measured value of Radon shown in 10 minute interval
④ Unit of measure : Shown in pCi/l or Bq/㎥. Unit can be changed by smartphone app.
⑤ Information display : SN, peak value, 1/2/7 day and month average, measurement time,
pulse count per 10 minute measurement (present value/last value)
Name and function of each part
BLE Access
Shock detection
Radon concentration
Unit
Information
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Name and function of each part
Front
LED : Red LED flashes for 30 seconds when Radon value exceeds
reference value.
Green LED flashes when Wi-Fi connection is not normal.
Ventilation window
LCD : Information display window for Wi-Fi access, shock detection,
Radon concentration, etc.
Rear
Power
12V DC
Radon ?
1. Radon is a colorless, odorless and tasteless radioactive gas.
Radon, a gas originating from radium which is generated by the collapse of
uranium in soil, is everywhere on earth. It penetrates indoors mainly from the
ground or building materials. The gases that cause sick house syndrome and
other noxious gases luckily smell. Urban gas and LPG were deliberately
smelled. However, radon does not smell nor can be seen. And no matter how
many years have passed, it is constantly released from the wall, ceiling and
floor.
2. Radon is 8 times heavier than air and is easily concentrated in the house.
Radon has the half-life of 3.8 days and makes alpha decay. The alpha particle
emitted from radon has the smallest penetration power among the radiation
rays and can not penetrate even a single piece of paper, but its destructive
power is so great that the cells are damaged if they are directly impacted by
radon, even having a nickname of "silent murderer". This is why radon detec-
tion sensor is absolutely needed in home.
3. Radon gas causes lung cancer.
Three causes of modern female lung cancer are passive smoking, ultrafine
particles and radon. When radon gas enters the lung through breathing, alpha
particles released from radon damage the lung cells. Since once destroyed
lung cells are not regenerated, prolonged exposure to high concentration of
radon gas will increase the likelihood of lung cancer. Therefore, the United
States Environmental Protection Agency(EPA) designated Radon as a must
be managed hazardous gas for healthy life.
- Accurate measurement value of the average radon level can be obtained when
the house is empty for 1 or 2 days.
- Reliable value can be obtained about 1 hour after start of the measurement.
- Radon concentration in the house is generally high at dawn and low at daytime,
so continuous measurement for more than 24 hours is necessary.
Precautions
•Please, Measure in an environment free from vibration.
•Shock or disassembly will cause the equipment to malfunction and will not
be included in the warranty. (the unit will display “ERR” message)
•Abnormal data can be measured when using near a strong electromagnetic
radiation source such as high voltage transmission line, subway line, Wifi
transmitter(1Meter or less), microwave oven(1M or less) ('OVER'
message)
•Use only indoors. No waterproof.
•Use the provided DC 12V adapter.
•Continuous use in an environment with relative humidity of 80% or
higher is prohibited.
•A warning message may be sent to the set mobile device when it is higher
than the set radon concentration.
•Proper operating temperature range is 10℃ ~ 40℃ (50°F ~ 100°F)
•The warranty period is one year after purchase.
<Radon concentration fluctuation graph>
Seasonal radon concentration
WinterAutumnSummerSpring
Daily radon concentration
Day Evening Day
Dawn
Precautions when using
Example of proper installation
· please, let the device where there is no ventilation
environment to check the area's usual radon status.
Prohibited
· Install at least 50cm apart from wall, window and floor.
· In general, proper places to install are on desk, table
in the living room, or on dining table in the kitchen.
Caution
1. For accurate measurement, close windows and doors tightly.
2. When RadonEye + is connected to DC 12V adaptor, measurement
starts automatically.
3. After the power is on, the wait time (10 minutes) is indicated by ‘- -’.
When wait time is over, the measured values are displayed from
10 minutes later. Measurements are displayed in 10 minute interval,
and saved in 1 hour interval.
To start the device
RADONEYE +
C_device
P_device
Measured value
12h 24h36h
Actual value
1h
RadonFTLab
0. 81
pCi/l
SN : RD21705010123
Precautions before using App.
This is the User's Manual for controlling RadonEye + device made in
Radon FTLab. Please refer to the detailed manual on the Radon FTLab
website (http://RadonFTLab.com) for the equipment and PC program
manual.
• Since it is an application that operates on a Wi-Fi base, there may be
operational limitations.
• It works properly in Android 4.3 version or iOS 8.0 version or later
• If the distance between the device and the smart device increases,
the
connection may be lost.
• In the 5G Internet environment, there are restrictions in the use of the
product, so please use 2.4G.
• We recommend user to agree to the privacy policy during the app
setting stage for trouble-free data transfer.
• Bluetooth and GPS must be enabled before using
• The time in the area where the equipment is installed is applied to the
data recorded after app setting/direct connection. The factory
Bluetooth & GPS function of
mobile device should be
activated for
RadonEye + setting
GPS
Bluetooth
RadonEye +
RadonEye + is the world's first IoT smart radon detector that is used in connec-
tion with web database based on WiFi. Therefore, RadonEye + is suitable for
real-time radon monitoring and easy to create Real-Time Radon Map. Manufac-
turer, Radon FTLab provides web database, radon-net.com, which means the
user can access the data every time, everywhere by smart phone, tablet or
internet connected desktop PC.
The sensitivity performance of RadonEye + is like a standard instrument. It is 20
times higher when it is compared with other general customer’s radon detector,
so the measurement data is fast and precise. Radon measurement data can be
recorded within 1 hour with below
±
10% error from starting time of measurement
and the data will be updated every 10 minutes so the user will get to know the
diminishing trend of indoor radon level just within 30 minutes by ventilation or
window open.
RadonEye + has added temperature & humidity sensor and measurement time
recording and extended the measurement range to 255pCi / l.
RadonEye + offers free web uploading service at least 2 years.
Measurement
Range
Precision
Accuracy
Data log
Display
Mobile control
Sensing factor
Time checking
Web access
Mobile notification
WiFi, Bluetooth
Radon,Humidity,Temperature
O
O
O
0.1~255 pCi/l
(1 ~9,435 Bq/㎥)
Model RadonEye (RD200) RadonEye + (RD200P2)
Bluetooth
Radon
X
X
X
0.1~100 pCi/l
(1 ~3,700 Bq/㎥)
< ±10%at 10pCi/l (370Bq/㎥)
< ±10%(min. error <±0.5pCi/l)
max1year(1hour interval)
0.96 inch OLED
< RadonEye VS RadonEye + >
1. What should I do under condition of no Wi-Fi around available?
A : RadonEye Plus2 automatically starts measuring when power is simply connected, so all you need to do is just select 'Connected Devices'
menu in your smartphone application even if you don't have a Wi-Fi
2. Tell me how to set up an app. when errors.
2.1. RadonEye Plus2 you are trying to set is not on the list.
A (iPhone) : Switch Bluetooth off and on to update the list again.
A (Android) : Click the "Rescan" button to update the list again.
2.2. The Wi-Fi list displayed on the app. does not contain the desired Wi-Fi I’d like to connect to.
A : Click the ‘refresh’ icon to update the Wi-Fi list. for your reference, 5GHz Wi-Fi is not supported and will not appear in the list.
2.3. If 'Wi-Fi settings failed' is displayed when next button is clicked after entering the Wi-Fi information.
A : If the green LED on RadonEye Plus2 keeps blinking and Wi-Fi connection is not successful, please check if Wi-Fi password is entered
correctly and internet connection status of the Router.
2.4. If the message 'RadonEye Plus2 registration failed' is displayed when the button is clicked after entering the Wi-Fi information,
A : Smartphone should also be Internet-connected through Wi-Fi / LTE / 3G
Check the Internet connection status of the smart device and proceed with setting under this circumstance.
2.5. If other cases of setting failure
A : Check the Wi-Fi and GPS connection on your smartphone, then turn the device off and on and run.
3. How can I change RadonEye Plus2 wifi connection that’s been already set into previous wifi place?
A : If you have Wi-Fi in your environment, you can set it up again and use it easily by clicking ‘Main’-‘Sub Menu’-‘Network’
4. It continues to show the high concentration figure, Is it out of order?
A : In this case, leave it in a well ventilated location for about two days and try to measure the low concentration at veranda, indoor air quality,
and high concentration in sequence
Q&A
RADON NET
RadonEye + provides Remote Radon Monitoring Network Service. You can
check radon value in the web browser by registering the registration key which
is given when you access the radon-net.com website when setting the app.
You can also check the local radon value at any time through Radon Map.
· My Devices
· Information
· Device Location
· Device Log (Graph)
· Radon Map
Sign In
Guest
Email
RADON NET
Password
Good
Normal
Warning
Bad
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Table of contents