INSTRUCTIONS FOR CHANGING COLLET CHUCKS
INSTRUCTIONS FOR CHANGING COLLET
CHUCKS
INSTRUCTIONS FOR CHANGING BRUSHES
INSTRUCTIONS FOR CHANGING BRUSHES
Do not expose electric tools to water, or use in damp or wet locations.
Turn the Motor Cap to the left and
remove it.
Take the worn out Carbon Brush out,
and replace with a new one and secure
it by screw.
Turn the Motor Cap to the right to fit
onto the Handpiece.
Using Phillips Screw Driver, remove the
screw that is securing the Carbon
Brush. Be careful not to loose the
screw.
When Carbon Brush is worn out, the Handpiece rotates unstably or stops.
Please replace the Carbon Brush, we recommend to replace both sides of the
Carbon Brush at the same time.
Open, inspect and test each item although we do test carefully prior to
shipments. Upon receiving repaired items, to check or test as well.
BASIC SAFETY AND PRECAUTIONS
Keep away from children.
Originally, φ2.34mm Collet is mounted. It is possible to replace with other
sizes of Collets according to demand. When replacing the Collet, insert the
Blank Bur or tool and loosen or tighten the Collet using the wrench which has
been supplied.
While holding the handpiece, turn the
Set Ring fully toward (R) direction. Be
sure that the Blank Bur is inside of
Collet. Place the Wrench on the Collet,
and turn it toward the direction of
"loosen". If the Collet slips and
impossible to loosen, try to hit the
Wrench by Hammer at an instance, and
remove the Collet. Be careful not to hit
your fingers.
Place the other Collet and turn the
Collet toward the direction of "tighten".
Make sure to secure the collet firmly.
Take the Wrench out and turn the Set
Ring back toward (S) direction.
Wear protective eyewear, wear proper clothes for working with dust,
always hold the handpiece securely, hold the handpiece while in
operation with the power on.
Do not wear loose clothing or jewelry and secure long hair as they can
be caught in the drill.
INSTRUCTIONS FOR CHANGING TOOL
Originally, ⌀2.34mm Blank Bur is mounted. Please use only the
tools with ⌀2.34mm shank which have been authorized.
While holding the handpiece,
turn the Set Ring fully toward
(R) direction. Take out the
Blank Bur and put the tool into
the bottom Collet.
Turn the Set Ring to (S)
direction, to secure your tool.
Spin the tool by fingers to
confirm that th tool is securely
fixed. Be careful with the blade
(edge) of tool not to hurt the
fingers.
Warning: NEVER TURN SET
RING WHILE MOTOR IS
ROTATING. PERMANENT
DAMAGE TO THE MOTOR IS
POSSIBLE.
When using electric tools, use basic safety precautions in order to
reduce risk of fire, electric shock, and personal injury.
Spin the tool by fingers to confirm that
the tool is securely fixed. Be careful with
the blade (edge) of tool not to hurt the
fingers.
SUGGESTED MAINTENANCE AND TIPS
All brush handpieces include a wrench tool which if needed can be used
to remove the collet chuck for replacement or cleaning. All brush
handpieces come with a spare set of 2 replacement carbon brushes.
This is a normal wearing part and estimated at 1,000hrs.
Do not leave the equipment rotating on table or floor.
CONTENTS
INSTRUCTIONS FOR CHANGING TOOL
SUGGESTED MAINTENANCE AND TIPS
PARTS LIST FOR HANDPIECE
SCHEMATIC DIAGRAM
BASIC SAFETY AND PRECAUTIONS
3-2022 issue 1
OWNER'S MANUAL
182 Ridge Road, Suite D, Dayton, N.J 08810
732.651.5500
732.651.6688
ram@ramhp.com
www.ramhp.com
PRIMUS 45 HANDPIECE
NO. NO.
136
237
38
3. 39
440
541
4. 642
743
844
5. 945
10 46
6. 11 47
12 48
7. 13 49
14 50 •
15
51
16 52 •
17 53
18 54 •
19 55
20 56
21 57
58
59
23 60
24
25
62
63
27 64
28 65
29 66
30 67
31 68
32
34
35
71
3 4
Perhaps change/replace every year or inspect once a year for wear. It is
suggested to tape these to the bottom of the controller and date it. For
the laboratory, it is easier and only a few minutes to replace and
maintain once a year as a minimal low cost maintenance. In the
operatory area, every 2-3 years should be adequate.
61
CARBON BRUSH
SPRING
PRIMUS 45 SPINDLE
ASSEMBLY
26
33
MOVING HOUSING
SPRING
SET RING TEFLON
WASHER
SNAP RING
1030 FIX O-RING
MOTOR CASE
MOTOR CASE BOLT
COIL
WEDGE
FAN
830 SPACER
BRUSH HOLDER
CARBON BRUSH
CARBON BRUSH CAP
TERMINAL (L)
69
CARBON HOUSING
COVER
70
MOVING HOUSING
MOTOR CASE COVER
BEARING BUSH COLLAR
BH60 CONNECTOR
SET RING
SET RING INSERT
CAM TEFLON WASHER
CAM
CAM BALL
M2.5
PARTS LIST FOR FOR PRIMUS 45 HANDPIECE
3
CHUCK HOUSING C-
RING
1370 WAVE WASHER
BH60 O-RING
22
BEARING BUSH COLLAR
WASHER
SET RING WASHER
PARTS NAME
HAND CAP COVER
HAND CAP HEAD
Never use chemicals for cleaning as often they are harsh and can
corrode parts. Use only isopropyl alcohol in either sealed wipes or with a
tissue to clean the exterior and any dust or debris that has accumulated.
BALL BEARING(1040ZZ)
Warranty is valid within the United States only.
HANDPIECES — These products are under warranty for a period of SIX
MONTHS from the date of original installation by the purchaser. IT DOES
NOT COVER MISUSE, NORMAL BEARING, OR CARBON BRUSH WEAR.
IN HOUSE OR FACTORY REPAIR - WARRANTY CLAIMS —
Please visit our website, www.ramprodinc.com, to download the Customer
Service Request Form located at the top right of the website page. For
warranty claims, please include a copy of your invoice or reference purchase
date. Repairs carry a 90 day warranty.
We maintain parts for Ram and many other similar models to perform service.
When sending items for service please pack it well with proper protection.
It is your responsibility to get the unit to us. Return shipping and handling is
covered by Ram Products, Inc.
1040 COPPER WASHER
1040 TEFLON WASHER
PARTS NAME
SM110 MAGNET GUIDE
COPPER WASHER
1030 WAVE WASHER
After sterilization of burs make sure they are completely dry and avoid
getting chemicals / disinfectants inside the handpiece.
For cleaning, it is suggested once a week to use a can of compressed
air often sold at office supply, computer supply stores. (The compressed
air at the bench is high pressure and can not only push any dust or dirt
inside further but also can upset the small balls that are part of the
bearings which are the life line of the handpiece.
WARRANTY PERIOD
PRODUCT WARRANTY
COLLAR
BEARING FIX WASHER
1370 WASHER
BALL BEARING(1370ZZ)
HAND CAP BODY
Use good quality burs. Do not force any burs into the chuck, make sure
burs are not eccentric. If any rust on the bur shaft, it is best to discard.
Always leave a bur securely locked in the handpiece. Wait for the
handpiece to stop spinning before changing burs.
SM110 MAGNET C
TERMINAL (R)
CARBON BRUSH BOLT
TEFLON WASHER
BEARING HOUSING
BACK BEARING SIT
BALL BEARING 1030ZZ
BR BRUSH BOLT
BALL BEARING(1480ZZ)
1480 WASHER
1480 WAVE WASHER
TEST BUR
CHUCK SPRING
JOINT SHAFT BODY
JOINT SHAFT
JOINT SHAFT FIX PIN
Electric lab handpieces have grease sealed ball bearings. Please do not
oil as you would air or high-speed handpieces as this would break down
the grease sealed bearings.
1040 SPACER
SHAFT Ø4
CORE
FRONT SHAFT BUSH Ø4
COMMUTATOR
COLLET CHUCK 2.35
CHUCK HOUSING
BUSH
In order to validate your warranty, the form must be filled out
completely on the website: www.ramprodinc.com/warranty within
10 days of purchase/installation.
Electrical and mechanical equipments which are mishandled, used incorrectly,
and/or used for a purpose other than that for which they were designed and
intended, will void the product warranty.
WARRANTY CLAIMS
All returned items shall be free from defects/alterations in material,
workmanship and original product design.
The product shall have been used under the conditions for which it has
been intended, and in a manner for which it has been designed.
The customer must maintain the product as specified within the
individual product instruction booklet.
The product shall have been operated in a manner for which it was
intended and in the proper environmental conditions.
Should your product require service within the warranty period, we will elect to
make the necessary repair or replacement at no charge including return
shipping. It is your responsibility to return the product to Ram Products and it
is recommended that returns have tracking information and to be adequately
insured against carrier loss or damage.
All claims should describe the specific problem for accurate analysis and
evaluation, the return date of the warranty card along with the supply house
and/or dealer name.
WARRANTY REGISTRATION
MOTOR CORD
ARMATURE ASSEMBLY

Other RAM PRODUCTS Dental Equipment manuals

RAM PRODUCTS iCUBE User manual

RAM PRODUCTS

RAM PRODUCTS iCUBE User manual

RAM PRODUCTS RP300 User manual

RAM PRODUCTS

RAM PRODUCTS RP300 User manual

RAM PRODUCTS BP50 User manual

RAM PRODUCTS

RAM PRODUCTS BP50 User manual

RAM PRODUCTS BP50 User manual

RAM PRODUCTS

RAM PRODUCTS BP50 User manual

Popular Dental Equipment manuals by other brands

Anthogyr torq control Instructions for use

Anthogyr

Anthogyr torq control Instructions for use

Dentsply Sirona DAC Universal Touch operating instructions

Dentsply Sirona

Dentsply Sirona DAC Universal Touch operating instructions

NSK Presto II Operation manual

NSK

NSK Presto II Operation manual

BEYES SLimax-C Operator's manual

BEYES

BEYES SLimax-C Operator's manual

DENTIUM ICT MOTOR Operating	 instruction

DENTIUM

DENTIUM ICT MOTOR Operating instruction

KaVo DIAGNOdent 2190 Instructions for use

KaVo

KaVo DIAGNOdent 2190 Instructions for use

Palisades Dental Impact Air 45 9 Care and use

Palisades Dental

Palisades Dental Impact Air 45 9 Care and use

DENTSPLY ORTHORALIX 9200 manual

DENTSPLY

DENTSPLY ORTHORALIX 9200 manual

Carestream DENTAL RVG 142 User's installation guide

Carestream DENTAL

Carestream DENTAL RVG 142 User's installation guide

FKG R-Motion Glide Instructions for use

FKG

FKG R-Motion Glide Instructions for use

BOREA RAYPLICKER quick start

BOREA

BOREA RAYPLICKER quick start

Cavitron JET Plus Directions for use

Cavitron

Cavitron JET Plus Directions for use

Aseptico AEU-1000-70V Operation and maintenance manual

Aseptico

Aseptico AEU-1000-70V Operation and maintenance manual

Coltene Coltolux LED owner's guide

Coltene

Coltene Coltolux LED owner's guide

DEFIANCE ELECTRONICS FUS336 Operation and maintenance instructions

DEFIANCE ELECTRONICS

DEFIANCE ELECTRONICS FUS336 Operation and maintenance instructions

Castellini Puma Eli manual

Castellini

Castellini Puma Eli manual

Dentsply Sirona MAILLEFER Thermaprep B00THPR230VEU Instructions for use

Dentsply Sirona

Dentsply Sirona MAILLEFER Thermaprep B00THPR230VEU Instructions for use

Donaldson BOFA DentalPRO Xtract 200 user manual

Donaldson

Donaldson BOFA DentalPRO Xtract 200 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.