Ravel RE -102 Guide

RE –102
RE - 104
Fire Alarm Control Panel
Installation, Commissioning & Operating
Manual

P/N RE - 102 / 104 Rev. No. 0
1

P/N RE - 102 / 104 Rev. No. 0
2

P/N RE - 102 / 104 Rev. No. 0
3
NOTES:

P/N RE - 102 / 104 Rev. No. 0
4
Table of Contents
CHAPTER 1: Introduction …………........…….....................4
1.1: System Design & Planning..............................................4
1.2: General .………...............................................................4
1.3: Fire Alarm Procedure ….................................................5
1.4: User Responsibility.........................................................5
1.5: Routine test............….....................................…………..6
CHAPTER 2: Product Description .....................................7
2.1: Product Features ...........................................................7
2.2: Specifications ...........................................................…..8
2.3: Controls and Indicators .................................................9
2.3.1: LED Indication...........................................…………...9
2.3.2: Controls……………………….…..….…………………..10
2.4: Mechanical Construction…….……………………………10
CHAPTER 3: Installation ..............................……..........….11
3.1: Installation Precaution……….……………………………11
3.2: Mounting Details ...................................................….…13
3.3: Input Circuits.............................................................….14
3.4: Output Circuits .........................................................….15
CHAPTER 4: Operating Instructions...….............….….....16
4.1: Switch Functions …………………….............................16
4.2: Status LED....................................….........................…17
4.3: Operation..................................................................….18
4.3.1: Zone Fault Response ................................................18
4.3.2: Zone Fault Restoral …...............................................18
4.3.3: Zone Fire Response ...........................................….. 18
4.3.4: Zone Fire Restoral …...........................................…. 18
4.3.5: programming Menu Flow Chart ….…………..............19
CHAPTER 5: Servicing……………………………..…………20
5.1: Walk test mode… …………………….............................20
5.2: Installation/Replacement of PCB................................…21
5.3: Test……....................................................................….21
5.4: Lamp Test…..............................................................….21
CHAPTER 6: Power Calculation….….………………………22
CHAPTER 7: Trouble Shooting……….……………………..23
CHAPTER 8: Terminal Detail….…..………………….………24

P/N RE - 102 / 104 Rev. No. 0
5
Chapter 1: Introduction
This manual is intended as a complete guide to the RE - 102 / 104
model Conventional Fire Control Panel. User operating Instructions are
provided in the first part of this manual. This is followed with sections
describing installation and commissioning procedures and full
technical details are provided.
1.1 System Design and Planning
It is assumed that the system, of this control panel is a part, which
has been designed by a competent fire alarm system designer in
accordance with the requirements of IS 2189: 1999 and any other
local codes of practice that are applicable. The design drawings
should clearly show the positions of the field devices and the control
equipment.
1.2 General
The panel is self-contained with integral power supply and space
provision for two sealed lead-acid standby batteries and comply with
the requirements of IS 2189: 1999. The panel functions are
microprocessor controlled and test and isolate functions are included.
Provision is made for a repeater function of panel status output. The
panel can accept, per zone, automatic detectors with a total
maximum loading of 2.4mA quiescent current rating (refer to chapter
2.2), and an unlimited number of manual call points.
End of Line (EOL) devices
The panels can continue to monitor manual call points with
detectors removed, providing the detectors are fitted with a Schottky
diode and an a EOL device is used.
Installation
The panel is easy to install and operate. The panel fascia is retained by
tamper-proof screws.

P/N RE - 102 / 104 Rev. No. 0
6
1.3 Fire Alarm Procedures
In accordance with IS 2189: 1999, written procedures should be laid
down for dealing with alarms of fire, fault warnings, and the isolation of
any part of the system. The responsible person should ensure that users
of the system are instructed in its proper use and are familiar with the
procedures.
On hearing the fire alarm:
CARRY OUT THE PRESCRIBED PROCEDURE Subsequent actions will
depend on the circumstances, and may include silencing the audible
alarms and resetting the system, as described later.
Fault Indication:
If the control panel indicates a Fault condition, make a note of all
illuminated indicators, refer to the chart on Page 23, and call the
service engineer.
1.4 User Responsibility
In addition to the routine testing described on routine test, the user has
a responsibility for ensuring certain actions are taken following a fire or
fault, and for implementing remedial action following a specified
incidence of false alarms. As a minimum, the user shall record any
incident and inform the service organization, who may be required to
retest the system. The user's responsibilities are described fully in IS
2189: 1999.

P/N RE - 102 / 104 Rev. No. 0
7
1.5 Routine Testing
In order to ensure that the system is fully operational, and to comply
with the requirements of IS 2189: 1999, the following routine attention is
recommended:
Daily - Check the panel to ascertain that it indicates normal
operation. If any fault is indicated check that it has been recorded
and that the appropriate actions have been taken, e.g. informing the
maintaining company.
Weekly - Test at least one detector or call point to confirm the
operation of the panel and the audible alarms. Test a different zone
each week and, if possible, a different device. Keep a record of the
device and zone tested each week. Record and report any
malfunction.
Quarterly - The responsible person should ensure that every three
months the system is checked by a competent person. Check the
standby batteries and the charger voltage Test at least one device in
each zone to check the panel functions. Check the operation of the
audible alarms and any link to a remote manned centre, Central
Station, etc. Carry out a visual inspection of the installation to check
for alterations or obstructions and issue a certificate of testing.
Annually - The responsible person should ensure that, in addition to
the quarterly checks, each device on the system is tested and that a
visual inspection is made of the cable fittings and equipment.
Note: The control panel case should be cleaned periodically by
wiping with a soft, damp cloth. Do not use any solvents.

P/N RE - 102 / 104 Rev. No. 0
8
Chapter 2: Product Description
The RE - 102 / 104 is a 2 / 4 zone microprocessor based conventional
Fire Alarm Control Panel. The Panel accepts water flow devices,
conventional input devices like 2 wire smoke detectors, pull stations
and other normally open contact devices. The Outputs include
Notification Appliance Circuits (sounders), Three Form – C relays 2
for alarm, 1 for fault and RS485 port to interface with remote
annunciator (Optional). It supervises all wiring, AC voltage and
Battery level.
2.1 Product Features
¾Rugged CRCA sheet with powder coated finish.
¾Operates on 220v, 50Hz AC supply.
¾Standby battery back up with built in charging.
¾Error free Fire / Fault status in unambiguous colored LED
indication.
¾Switch Mode Power Supply.
¾16 X 2 LCD Display.
¾Tactile key pad for easy operation.
¾Main, Standby status indication.
¾Low Battery visual warning with audible tone.
¾Zone wise one man walk test facility.
¾RS 485 communication port for Repeater / network. (Optional).
¾Relay output for actuators.
¾Lamp Test facility.
¾Zone Isolation facility with loop voltage cut off.
¾Programmable Keypad lock.
¾Programmable Auto Silence.
¾Compatible to all types of conventional detectors.

P/N RE - 102 / 104 Rev. No. 0
9
2.2 Specification
AC Power
220 VAC, 50 Hz. +10% - 15%
Battery (Lead Acid only)
Charging: Constant Voltage – 27.6v @ 0.5A(Max)
Charging Capacity: 7 Amp Hour Battery Max.
System Quiescent Current: 60mA
Initiating Device Circuits (Zone Circuit)
All zones are Class B wiring
Normal Operating Voltage: Nominal 24 VDC
Alarm Current: 15 – 35mA threshold
Short Circuit Current: 42mA Maximum
Loop resistance: 50 ohms Maximum
End-Of-Line Resistor: 4.7K, 1/4watt
Standby Current: 6.8mA (2.4mA for Detectors)
Notification Appliance Circuits (Sounder Circuit)
Class – B wiring
Operating Nominal Voltage: 24 VDC
Hooter (NACs) output: 1A
End-Of-Line Resistor: 4.7K, 1/4watt
Three Form – C Relays
Relay Contact Rating: 2Amps @ 30 VDC, 2Amps @ 30VAC (Fire – 2
No’s, Fault – 1 No.).

P/N RE - 102 / 104 Rev. No. 0
10
2.3 Controls and Indication
2.3.1 LED Indication
System On – Green
A.C Power On – Green
Standby On – Green
Hooter Fault – Yellow
Silenced – Yellow
Zone Fire – Red
Zone Fault – Yellow
Zone Isolate / Walktest – Yellow
Local Buzzer
A piezo buzzer provides separate and distinct sounds for
alarm and trouble conditions:
Alarm – steady
Fault – pulse 0.5sec ON and 0.5sec OFF
2.3.2 Controls
SILENCE Key: During fire/fault condition, silence key is used to
silence the external Sounders (NAC) and the internal buzzer
tone.

P/N RE - 102 / 104 Rev. No. 0
11
RESET Key: This key is pressed to reset the entire system and
While in reset condition, all detector loop voltages are cut off
up to 3 seconds for Detectors and MCP’s, Then voltages are put
on to the loop.
CURSOR KEYS: The cursor keys (Right / Left arrows) are used to
move the menu list and menu options.
ENTER Key: This key is used to enter into menu edit mode and
accept the changes of edited menu. This key also used for
lamp test in system normal condition.
MENU Key: This key is used to enter into the Main menu in the
LCD.
2.4 Mechanical Construction
The enclosure of the Panel is constructed by CRCA sheet
with powder coated finish and it’s designed to afford the degree
of protection as per IP-54. The ∅19mm knock outs are given for
cable entry at the top of the cabinet.
The panel also has a built in battery provision to
accommodate 2 Nos. of 12v, 7Ah batteries.
The front side of the panel consists of the following,
a. Tactile switches.
b. LED indications

P/N RE - 102 / 104 Rev. No. 0
12
Chapter 3: Installation
3.1 Installation Precaution
Installation Precautions
WARNING - Several different sources of power can be
connected to the fire alarm control panel. Disconnect
all sources of power before servicing. Control unit and
associated equipment may be damaged by
removing and/or inserting cards, modules, or
interconnecting cables while the unit is energized. Do
not attempt to install, service, or operate this unit until
this manual is read and understood.
CAUTION - System Reacceptance Test after Software
Changes. To ensure proper system operation, this
product must be tested in accordance with NFPA 72
after any programming operation or change in site-
specific software. Reacceptance testing is required
after any change, addition or deletion of system
components, or after any modification, repair or
adjustment to system hardware or wiring. All
components, circuits, system operations, or software
functions known to be affected by a change must be
100% tested. In addition, to ensure that other
operations are not inadvertently affected, at least 10%
of initiating devices that are not directly affected by
the change, up to a maximum of 50 devices, must
also be tested and proper system operation verified.
This system meets NFPA requirements for indoor dry
operation at 0-49° C/32-120° F and at a relative
humidity of 93 ±2% RH (non-condensing) at 32 ±2°
C/90 ±3° F. However, the useful life of the system's
standby batteries and the electronic components
may be adversely affected by extreme temperature
ranges and humidity. Therefore, it is recommended
that this system and all peripherals be installed in an
environment with a nominal room temperature of 0-
50° C/32-120° F.

P/N RE - 102 / 104 Rev. No. 0
13
Verify that wire sizes are adequate for all initiating and Indicating
device loops. Most devices cannot tolerate more than a 10% I.R. drop
from the specified device voltage.
Adherence to the following will aid in problem-free
installation with long-term reliability:
Like all solid-state electronic devices, this system may operate
erratically or can be damaged when subjected to lightning-induced
transients. Although no system is completely immune from lightning
transients and interferences, proper grounding will reduce
susceptibility. Overhead or outside aerial wiring is not recommended,
due to an increased susceptibility to nearby lightning strikes. Consult
with the Technical Services Department if any problems are
anticipated or encountered.
Disconnect AC power and batteries prior to removing or inserting
circuit boards. Failure to do so can damage circuits.
Remove all electronic assemblies prior to any drilling, filing, reaming,
or punching of the enclosure. When possible, make all cable entries
from the sides or rear. Before making modifications, verify that they will
not interfere with battery, transformer, and printed circuit board
location.
Do not tighten screw terminals more than 9 in-lbs.
Over-tightening may damage threads, resulting in reduced terminal
contact pressure and difficulty with screw terminal removal.
Though designed to last many years, system components
can fail at any time. This system contains static-sensitive
components. Always ground yourself with a proper wrist strap before
handling any circuits so that static charges are removed from the
body. Use static-suppressive packaging to protect electronic
assemblies removed from the unit.
Follow the instructions in the installation, operating, and programming
manuals. These instructions must be followed to avoid damage to the
control panel and associated equipment. FACP operation and
reliability depend upon proper installation by authorized personnel.

P/N RE - 102 / 104 Rev. No. 0
14
3.2 Mounting Details
Place the panel in its mounting position and fix the panel to the
wall using the slots of the four screws. Ensure the enclosure and the
inner parts of the panel are given sufficient protection during
installation. All external cables are to be entered via the ∅19mm
preformed knockouts located at the top of the panel.
When the installation of all the cables has been completed, clean
the interior of the enclosure ensuring all masonry debris and drilling
swords are removed.
30 mm
290 mm 30 mm
175 mm
35 mm
185 mm

P/N RE - 102 / 104 Rev. No. 0
15
3.3 Input Circuits
The control panel has 2 / 4 zone input circuits depending on the
variant. The maximum loop resistance limit for each input circuit is
50 ohms. All field wiring of each zone is supervised for opens and
ground faults. Both conditions are visually and audibly (toggle tone)
annunciated.
Each zone is a Class B Initiating Device Circuit (IDC – Zones)
designed to accept any normally open contact devices and
conventional 2-wire, 24 volt smoke detectors.
It is allowable to mix an assortment of device types (i.e. smoke
detectors, heat detectors, pull stations, etc.) on any zone.
Zone Circuit – Class B

P/N RE - 102 / 104 Rev. No. 0
16
3.4 Output Circuits
Sounder Circuits: The RE - 102 / 104 provides Notification Appliance
Circuits standard as Class B. The total load capacity of this circuit is
capacity of this O/P is 1Amps.
Sounder Circuit – Class B
Note: If the non polarized devices are used, connect the device as
mentioned in page 23.
Standard Relay
The control panel provides three Form-C relays (2 for Fire & 1 fro Fault)
rated for 2.0 amps @ 30 VDC and 2.0 amps @ 30 VAC. Relay
connections are power-limited.

P/N RE - 102 / 104 Rev. No. 0
17
Chapter 4: Operating Instruction
4.1 Switch Functions
SILENCE Key: This key is used in Fire / Fault Condition. To
acknowledge the external sounder / internal buzzer press this key.
During fire condition, after silencing the silence LED glows to
indicate that external Sounders (NAC) are silenced.
RESET Key: This key is used in only Fire Condition. The panel is reset
by pressing this key followed by password if enabled. During reset
condition, all the detector input voltages are cut off up to 3
seconds for Detectors and MCP’s, Then voltages are put on to the
loop.
ENTER Key: This key is used to check the all LED’s in panel is in good
condition with continuous buzzer tone in normal operating
condition. The same key is used to accept the selection of menu
and changes done in the menu.
CURSOR KEYS: The cursor keys (Right / Left arrows) are used to move
the menu list and menu options.

P/N RE - 102 / 104 Rev. No. 0
18
MENU Key: The MENU key is used to enter into the programming
mode for changing the zone status and other settings. The various
steps involved in this menu are shown as flow chart 4.3.5. After
entering into the menu, screen will be as below,
4.2 Status LED:
Normal: In the Normal Condition, SYSTEM ON, AC POWER ON, green LED will
be illuminated. There should be no other amber / red LED visual
indication or audible tone.
A.C POWER ON: This LED indicates the presence of main supply.
Whenever the Main Supply (220v A.C) is present this LED will glow.
Whenever the Main Supply (220v A.C) fails / fuse blown, the AC Power
on LED will OFF and it also indicated by fault Buzzer tone.
BATTERY ON: This LED indicates the presence of standby power supply.
Whenever the Main Supply (220v A.C) fails, the panel supply is
switched to standby power supply with BATTERY ON indication.
Whenever the backup battery fails / fuse blown, the battery fail is
indicated by LCD with fault Buzzer tone.
Note:
Whenever the backup battery voltage goes below the 21v, the
battery on LED will be blinking with toggle Buzzer tone.
HOOTER FAULT: Whenever there is any fault in Notification Appliances
Circuits like Hooter (Sounder) loop open / short, it will be identified by
COMMON HOOTER FAULT LED.
SILENCED: Whenever the External Sounders are silence in presence of
actual fire. After silencing this LED glows with toggle buzzer tone.
1. Zone 1
Enable

P/N RE - 102 / 104 Rev. No. 0
19
4.3 Operation
4.3.1 ZONE FAULT RESPONSE:
When faults like Open/ Short occurred in the loop, the
corresponding ZONE FAULT LED would identify it.
Note: During the above fault conditions, apart from the
specific fault identification LED, common fault relay and
Local buzzer with intermittent tone will be activated. During
this time, if ‘SILENCE.’ is activated, intermittent tone will be
silenced.
4.3.2 ZONE FAULT RESTORAL:
When the faults condition of the FAP is restored, then the
corresponding fault LED goes off and also common fault relay and
intermittent buzzer tone is deactivated.
4.3.3 ZONE FIRE RESPONSE:
When the control panel detects Fire via the Detector / MCP, the
corresponding ZONE FIRE red LED will be illuminated. At the same
time hooter, potential free contact (Fire Relay) and local buzzer
(continuous tone) will be activated.
The External hooter (NAC / Sounder) and buzzer will be silenced by
using the Silence Key and silenced LED indicates it.
Always the recent fired zone FIRE LED will blink continuously, rest of
the fired zone FIRE LED’s will glow constantly till it goes to RESET. The
FIRE LED indication will remain ON condition till the panel is RESET.
4.3.4 ZONE FIRE RESTORAL:
The control panel returns to normal after all alarms have been
cleared and a system reset key has been pressed followed by the
password if enabled. The control panel will perform the following upon
restoral of all active alarms, The Zone Fire LED, Hooters, buzzer and fire
relay are turn off.
Note:
1. The Fire relay will be in ON condition till the fire and fault
LED’s go OFF.
This manual suits for next models
2
Table of contents
Other Ravel Control Panel manuals