19
Operating Your Grill
Adjustable Parameter 1: Min Feed Rate - Min Feed Rate is the
minimum rate that the auger is allowed to feed fuel to the fire pot,
regardless of Set Point. Decreasing the value will allow the grill to
achieve lower temperatures but will increase the risk of flame-outs.
Increasing the value will prevent losing fire but will limit your ability
to maintain low temperatures on hot, sunny days. Note: Changing
this does not change the auger speed. The auger speed is constant.
Turning the Temperature Control Knob clockwise will increase,
and turning counterclockwise decrease, the value within the range
of 5 - 250. (Factory preset: 10)
Adjustable Parameter 2: Temperature Offset - Your grill has
been precisely calibrated at our facility, but the Temperature Offset
allows you to customize how your controller will operate. Should
you choose to rely on a secondary temperature probe, you can use
the following process to recalibrate your Smart Grill Technology
Controller. Adjustable Parameter 2 will display OFS.
Offset Calibration Video Link
Additionally, the current temperature offset percentage value will
be displayed. Turning the Temperature Control Knob clockwise will
increase, and turning counterclockwise decrease, the value within
the range of -25.0 to 25.0. (Factory preset: 0)
Probe A/B Calibration - video link
Reset - Take the dial and turn to YES. Then hold down the settings
button to exit and the grill will be reset to factory settings.
Due to varying qualities of pellet brands, we give you the ability to adjust your
minimum feed rate downward in the event that your grill is running hot at lower
temperatures. However, if you experience a sudden loss, followed by an
immediate increase in grill temperature, then your grill has experienced a flame
out and will automatically relight. This signifies that your minimum feed rate was
adjusted too low and needs to be increased.
Adjustable Parameter 1
Adjustable Parameter 2
Probe A Calibration
Probe B Calibration
1
10
AUG
2
0
OFS
3
0
PrA
4
0
PrB
Reset
5
NO
rSt
Settings Button: Press and hold the settings button to access the adjustable parameters menu. Short presses
of the settings button will scroll through the adjustable parameters. Pressing and holding the settings button
will exit the adjustable parameters menu.
Test Mode: With grill OFF, press and hold the Settings Button to enter the Adjustable Parameters Menu.
Enter Test Mode from either of the five screens AUG, OFS, PrA, PrB, or rSt by pressing the Power Button.
Each additional press of the Power Button will advance you through the 8 Test Mode screens. The last screen
is the BYE screen. While on the BYE screen, press the Settings Button to return to the adjustable parameters
screen, then press and hold the Settings Button and your grill’s controller will return to the OFF state.