Operating Your Grill
Settings Button: Press and hold the setting button to access the adjustable parameters menu. Short presses
of the settings button will scroll through the adjustable parameters. Pressing and holding the settings button
will exit the adjustable parameters menu.
Test Mode: With grill OFF, press and hold the Settings Button to enter the Adjustable Parameters Menu.
Enter Test Mode from either of the four screens AUG, OFS, PrA, or PrB by pressing the Power Button. Each
additional press of the Power Button will advance you through the 8 Test Mode screens. The last screen is
the BYE screen. While on the BYE screen, press the Settings Button to return to the adjustable parameters
screen then press and hold the Settings Button and your grill’s controller will return to the OFF state.
Adjustable Parameter 1: Min Feed Rate - Min Feed Rate is the
minimum rate that the auger is allowed to feed fuel to the fire pot,
regardless of Set Point. Decreasing the value will allow the grill
to achieve lower temperatures but will increase the risk of flame-
outs. Increasing the value will prevent losing fire but will limit your
ability to maintain low temperatures on hot, sunny days. Note:
Changing this does not change the auger speed. The auger speed
is constant.
Adjustable Parameter 1 controller will display AUG. Additionally,
the current auger minimum feed rate will be displayed as a
number. Turning the Temperature Control Knob clockwise will
increase, and turning counterclockwise decrease, the value within
the range of 5 - 250. (Factory preset: 30)
Adjustable Parameter 2: Temperature Offset - Your grill has
been precisely calibrated at our facility, but the Temperature
Offset allows you to customize how your controller will operate.
Should you choose to rely on a secondary temperature probe,
you can use the following process to recalibrate your Smart Grill
Technology Controller. Adjustable Parameter 2 will display OFS.
Additionally, the current temperature offset percentage value will
be displayed. Turning the Temperature Control Knob clockwise
will increase, and turning counterclockwise decrease, the value
within the range of -25.0 to 25.0. (Factory preset: 0)
Reset - Take the dial and turn to YES. Then hold down the settings
button to exit and the grill will be reset to factory settings.
Due to varying qualities of pellet brands, we give you the ability to adjust your
minimum feed rate downward in the event that your grill is running hot at lower
temperatures. However, if you experience a sudden loss, followed by an
immediate increase in grill temperature, then your grill has experienced a flame
out and will automatically relight. This signifies that your minimum feed rate was
adjusted too low and needs to be increased.
Adjustable Parameter 1
Adjustable Parameter 2
Probe A Calibration
Probe B Calibration
1
35
AUG
2
0
OFS
3
0
PrA
4
0
PrB
Reset
5
NO
rSt