PAGE 2 (TWO - INSIDE DPS)
FLSMD Site Flood Multi-voltage
Product Codes: FLSMD50Y1, FLSMD100Y1, FLSMD150Y1,
FLSMD200Y1
Box Contents -
1 x LED SMD Yellow Floodlight
Dimensions:
FLSMD50Y-1: L: 310 x W: 310 x D: 65mm
FLSMD100Y-1: L: 320 x W: 320 x D: 90mm
FLSMD150Y-1: L: 365 x W: 370 x D: 94mm
FLSMD200Y-1: L: 425 x W: 410 x D: 110mm
Material: Body: Die-Cast Aluminium
Lens: Tempered Glass
Colour
Temperature: 6500k
CRI: Ra70
LED Lifetime: 35,000 Hrs
Beam Angle: 120° Symmetrical
IP Rating: IP65
Ik Rating: IK07
Working
Temperature: -20°C - 40°C
Power Factor: 0.9
Guarantee: 3 Years
Safety Warning
• The installation should be carried out
by a qualied electrician in compliance
with the current edition of the IEE
Wiring Regulations.
• Prior to installation, carry out the
necessary risk assessment considering
the people who could be at risk,
the level of risk and the precautions
required to control the risk
• Ensure that the circuit supply is
isolated either by the circuit supply
fuse being removed or the applicable
circuit breaker being turned o before
installation or any maintenance.
• Check the total load on the circuit
ensuring the luminaire does not exceed
the rating of the circuit cable, fuse or
circuit breaker.
• Long-term use and voltage uctuations
can reduce the life span of the tting.
• If the tting incorporates control gear,
ensure careful sizing to avoid instances
of nuisance tripping of the protective
device used in the installation.
• Follow the provided installation
instructions, using the xings supplied
or recommended.
• Keep out of reach of children.
86-
264V
IP65
3
YRS
GUARANTEE
INSTALLATION INSTRUCTIONS
IK07
PAGE 1 (FRONT PAGE)
Specication
50-
200
WATT
LED
6500K
W mm
L mm
D mm
PAGE 2 (TWO - INSIDE DPS)
PAGE 1 (FRONT PAGE)
1. Ensure there is adequate free air circulation of at least 100mm around the luminaire. All luminaires run hot. It is the installer’s responsibility to consider any
re risks and take appropriate precautions.
2. The nearest illuminated surface must be at least 0.5m from the front of the tting.
3. Do not use if the glass is broken. Replace the luminaire
4. Select an appropriate mounting position. Drill holes for xing at spacing corresponding to the holes on the ttings bracket..
5. Fix the bracket to the wall or similar hard surface with suitable xings (not included).
6. Connect the cable correctly to the supply, observing the colour-coding shown below. Ensure all electrical connections are tight with no loose strands.
Installation Instructions
• Please note this is an IP65 rated product, take care not to break any seals as this will aect it’s water resistant rating.
• Do not modify this product. Any modication to this tting will void the warranty.
• Red Arrow will not take any responsibility for any product damages caused by mounting procedures which are not in accordance with these instructions.
• These ttings comply to CE and UKCA standards.
• Powder coated nish
Additional Information
L = Brown
= Green/ Yellow
N = Blue
INS/SITE/0010/FLSMD-1/V2
T: 0800 195 0006
sales@redarrowelectrical.co.uk
Red Arrow Electrical Distribution
Cortonwood Drive, Brampton,
Barnsley, S73 0UF
redarrowelectrical.co.uk
This product is guaranteed for a period of 3 years from the date of purchase. The guarantee is invalid in the case of improper use, tampering, removal of the Q.C.
date label, installation in an improper working environment or installation not according to the current edition of the I.E.E. Wiring Regulations (BS7671). The
guarantee is also invalidated if the luminaire has been insulation tested. Should this product fail during the guarantee period it will be replaced free of charge,
subject to correct installation and return of the faulty unit. We do not accept responsibility for any installation costs associated with the replacement of this
product. Your statutory rights are not aected. We reserve the right to alter specications without prior notice.
• This tting will require routine cleaning if used in adverse (dust, paint, welding, oils etc) environments. Do not use solvents, aggressive detergents or
abrasives.
• The light source & driver in this luminaire can be replaced at end of life. This should be carried out by a competent person. Contact Red Arrow for details of
replacements.
Guarantee
Maintenance
• When this tting comes to the end of it’s life or you choose to replace it, please do not dispose of it with your normal waste. Please recycle where the
facilities exist, check with your local authority for suitable options.

This manual suits for next models

3

Other Red Arrow Floodlight manuals

Red Arrow KRY10 User manual

Red Arrow

Red Arrow KRY10 User manual

Red Arrow FLAC50Y User manual

Red Arrow

Red Arrow FLAC50Y User manual

Red Arrow CMT50Y User manual

Red Arrow

Red Arrow CMT50Y User manual

Red Arrow FLSMD50Y-1 User manual

Red Arrow

Red Arrow FLSMD50Y-1 User manual

Red Arrow FLSMDPC10BOPI User manual

Red Arrow

Red Arrow FLSMDPC10BOPI User manual

Red Arrow FLAC50Y User manual

Red Arrow

Red Arrow FLAC50Y User manual

Red Arrow FLSMD100BPC-1 User manual

Red Arrow

Red Arrow FLSMD100BPC-1 User manual

Red Arrow LEDFL30B-RGB User manual

Red Arrow

Red Arrow LEDFL30B-RGB User manual

Red Arrow FLSMD50BPC-1 User manual

Red Arrow

Red Arrow FLSMD50BPC-1 User manual

Popular Floodlight manuals by other brands

Lithonia Lighting ESXF1 P0 installation instructions

Lithonia Lighting

Lithonia Lighting ESXF1 P0 installation instructions

Hubbell Linear LED ALF12LU5KBZ Series installation instructions

Hubbell

Hubbell Linear LED ALF12LU5KBZ Series installation instructions

SImx Mightylite LHT0237 installation guide

SImx

SImx Mightylite LHT0237 installation guide

OXO COLORBEAM 7 FC IR user manual

OXO

OXO COLORBEAM 7 FC IR user manual

Chauvet Legend 412 QRG Quick reference guide

Chauvet

Chauvet Legend 412 QRG Quick reference guide

Lexing LX-LD-102P118-36 instructions

Lexing

Lexing LX-LD-102P118-36 instructions

Chauvet Nexus Aq 5x5 Quick reference guide

Chauvet

Chauvet Nexus Aq 5x5 Quick reference guide

Gewiss SMART 4 Series quick start guide

Gewiss

Gewiss SMART 4 Series quick start guide

Qtx HIPAR-126 user manual

Qtx

Qtx HIPAR-126 user manual

Pro-Elec PELL0289 quick start guide

Pro-Elec

Pro-Elec PELL0289 quick start guide

EuroLite LED FE-900 Hybrid user manual

EuroLite

EuroLite LED FE-900 Hybrid user manual

Mobile Power 4039 instruction manual

Mobile Power

Mobile Power 4039 instruction manual

EuroLite LED IP T2000 WW user manual

EuroLite

EuroLite LED IP T2000 WW user manual

Glamox O92 SYM user manual

Glamox

Glamox O92 SYM user manual

Fanton 62610 quick start guide

Fanton

Fanton 62610 quick start guide

GigaTera SUFA-H user guide

GigaTera

GigaTera SUFA-H user guide

stellar labs 555-15600 User handbook

stellar labs

stellar labs 555-15600 User handbook

ACHATE Discolamp instructions

ACHATE

ACHATE Discolamp instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.