manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. REED
  6. •
  7. Measuring Instrument
  8. •
  9. REED R9700 User manual

REED R9700 User manual

Other REED Measuring Instrument manuals

REED PHT-316 User manual

REED

REED PHT-316 User manual

REED K7020 User manual

REED

REED K7020 User manual

REED R5000 User manual

REED

REED R5000 User manual

REED SD-8205 User manual

REED

REED SD-8205 User manual

REED ST-1301 User manual

REED

REED ST-1301 User manual

REED R3000SD User manual

REED

REED R3000SD User manual

REED C-322 User manual

REED

REED C-322 User manual

REED R7100 User manual

REED

REED R7100 User manual

REED ST-8850 User manual

REED

REED ST-8850 User manual

REED LM-81HT User manual

REED

REED LM-81HT User manual

REED ST-9809 User manual

REED

REED ST-9809 User manual

REED LM-8000 User manual

REED

REED LM-8000 User manual

REED SL-417 User manual

REED

REED SL-417 User manual

REED C-317 User manual

REED

REED C-317 User manual

REED ST-332 User manual

REED

REED ST-332 User manual

REED SD-4023 User manual

REED

REED SD-4023 User manual

REED R5015 User manual

REED

REED R5015 User manual

REED R8150 User manual

REED

REED R8150 User manual

REED R5060 User manual

REED

REED R5060 User manual

REED R5040 User manual

REED

REED R5040 User manual

REED r8001 User manual

REED

REED r8001 User manual

REED R3002 User manual

REED

REED R3002 User manual

REED R7700 User manual

REED

REED R7700 User manual

REED GU-3001 User manual

REED

REED GU-3001 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

reedinstruments
www com
Model R9700
Anti-freeze & Battery Fluid
Refractometer
Instruction
Manual
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
reedinstruments
www com
2
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Specifications
Measuring Range: -50 to 0°C propylene and ethylene glycol
1.15 - 1.30 specic gravity
Minimum Scale Division: 5°C
Dimensions: 30 x 40 x 170mm (1 x 1.5 x 6.5”)
Automatic Temperature Compensation Range:
10 to 30°C
Weight: 200g (7 oz)
Instrument Description
1. Prism
2. Cover Plate
3. Correcting Screw
4. Mirror Tube
5. Eyepiece (Adjusting ring of diopter)
Operating Instructions
1. Use dropper to obtain coolant sample, open the cover plate and place 2-3
drops of the sample onto the prism surface, close the cover plate, press
lightly and ensure the water spreads evenly across the whole surface area
without air bubbles or dry sections. Wait 30 seconds until the liquid sample
adjusts to ambient temperature.
2. Hold towards light source and look into the eyepiece to view the scale, the
coolant readings are located on the far left and right and the battery uid
reading is in the centre.
3. The test reading is taken from where the boundary line between the upper
blue eld and the lower white eld crosses the graduated scale. This reading
is the actual freezing point/concentration level of the coolant or the charge
state of the battery uid.
4. Wipe the prism clean and dry with damp soft cloth and store in the supplied
case.
reedinstruments
www com
3
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Calibration
1. Open the cover plate and place 2-3 drops of distilled water onto the prism
surface, close the cover plate, press lightly and ensure the water spreads
evenly across the whole surface area without air bubbles or dry sections.
(wait 30 seconds until the water adjusts to ambient temperature)
2. Hold towards light source and look into the eyepiece, if the boundary line
between the upper blue eld and the lower white eld is not located exactly
on the 0°C waterline, adjust the correcting screw until both lines meet.
3. Wipe the water from the prism with clean dry cloth and replace the rubber
correcting screw cover.
NOTE: under normal operating conditions the calibration only needs to be checked
periodically.
Maintenance
1. If the ambient temperature is not within the automatic temperature
compensation range (10 - 30°C) the instrument must be calibrated before
testing commences.
2. The prism must be cleaned thoroughly with a soft, clean damp cloth after
each use - failure to do so will result in inaccurate readings and possible
long term
damage.
3. The instrument must be kept in a dry clean environment to prevent
condensation forming on the optical components.
4. Use a glass rod to sample battery uid as acid will damage the dropper and
also harm your skin–separate readings must be taken from each cell
5. If used in accordance with the instructions and all warning are followed -
the optical performance will remain constant and the instrument will give
many years of reliable service.
reedinstruments
www com
4
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Warning
1. DO NOT IMMERSE IN OR CLEAN WITH RUNNING WATER
2. THIS TOOL IS A PRECISON OPTICAL INSTRUMENT, IT REQUIRES
CAREFULL HANDLING and STORAGE
3. DO NOT DROP OR SUBJECT TO SHOCK AS DAMAGE MAY RESULT TO
THE MIRROR TUBE and OPTICAL COMPONENTS
4. DO NOT SCRATCH OR ATTEMPT TO MEASURE CORROSIVE CHEMICALS
AS DAMAGE MAY OCCUR TO THE PRISM’S COATING
CAUTION – use extreme care when opening the radiator cap – do not remove while
engine is running or the engine is warm. Do not let battery uid come in contact with
skin or eyes – personal injury may result
IT IS RECOMMENED TO WEAR, SAFETY GLASSES AND GLOVES WHENEVER
OBTAINING SAMPLES OF ENGINE COOLANT OR BATTERY FLUID