REED R5050 User manual

reedinstruments
www com
R5050
TRMS AC/DC
Clamp Meter
Instruction
Manual
Model
INSTRUMENTS
INSTRUMENTS
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
2
INSTRUMENTS
INSTRUMENTS
Table of Contents
Safety ............................................................................................ 3
Features......................................................................................... 4
Specications.............................................................................4-6
Instrument Description .................................................................. 7
Display Description ....................................................................... 7
Operating Instructions................................................................... 8
Data Hold Function .................................................................................. 8
Peak Hold Function.................................................................................. 8
MAX/MIN Function................................................................................... 8
REL Function ........................................................................................... 8
Measurement Procedures ........................................................9-12
Current Measurement .............................................................................. 9
ACA ...................................................................................................... 9
DCA ...................................................................................................... 9
Voltage measurement ............................................................................ 10
Resistance measurement....................................................................... 10
Continuity Test ....................................................................................... 11
Diode Test.............................................................................................. 11
Frequency measurement from the terminals........................................... 12
Frequency measurement with the clamp................................................ 12
Battery Replacement................................................................... 13
Product Maintenance .................................................................. 13
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
3
INSTRUMENTS
INSTRUMENTS
Safety
•
Read this manual before using the meter and follow all safety guidelines.
• Usethemeteronlyasspeciedinthisinstructionmanual.Otherwise
the meters protection may be impaired.
•
Never use this meter on a circuit with voltages greater than 750Vrms @ 50/60 Hz.
• Donotoperatethemeterifthebodyortestleadslookdamaged.
• Checkthefunctionselectorrangeswitchandmakesureitisatthe
correctpositionbeforeeachmeasurementistaken.
• Donotperformresistanceandcontinuitytestsonalivecircuit.
• Exerciseextremecautionwhenmeasuringlivesystemswithvoltages
greaterthan60VCCor30VCA.
• Useextremecarewhenworkingaroundbusbarsandbareconductors.
• Donotusethemeterinoverrange/overloadconditions(OL).
•
Changethebatterywhenthe symbol appears to avoid incorrect readings.
Environmental Conditions
Altitudeupto2000meters.
OperatingTemperature:0°Cto40°C,<80%RH,non-condensing
StorageTemperature:-10°Cto60°C,<70%RH,batteryremoved
Pollution Degree: 2
Symbols
Attention!Refertooperationinstructions.
Dangerous voltage may be present at terminals.
This instrument has double insulation.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
4
INSTRUMENTS
INSTRUMENTS
Features
• MeasuresAC/DCcurrent/voltage,resistanceandfrequency
• 4000-countLCDdisplaywithanalogbargraph
• Lowbatteryandoverrangeindicators
• TrueRMSmeasurements
• Min/Max,displayhold,peakholdandrelativemode
• Diodetestandcontinuitycheckfunctions
• Cat.III600V,Cat.II1000Vsafetyrating
• Includestestleads,batteryandsoftcarryingcase
Specifications
DigitalDisplay: 33/4digitsLCDdisplaywithmaximumreading3999
AnalogDisplay: Fast40segmentanalogbargraphdisplay
Symbol &
ScaleRange: Automaticdisplayaccordingsymbols
and range input signal
Polarity: is displayed when negative signal applied to
the input
OverLoad: isdisplayedwheninputsignalexceedsrange
Sample Rate: 2 times/sec for digital data; 20 times/sec for
analog bar
LowBatteryIndication: is displayed when the battery is below the
requiredvoltage
AutoPowerOff: Bydefault,themeterisinautopoweroffmode.
The meter will power itself off after 30 minutes
without operation. To disable the auto power
off,pressandholdtheMAX/MIN button and
turn the meter on.
Jaw Opening: 40mm
PowerSupply: 9V,NEDA1604or6F22or006P
BatteryLife: 40hourstypically(Alkaline)
Dimensions: 9.53x2.60x1.4"(242x66x36mm) continued ...
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
5
INSTRUMENTS
INSTRUMENTS
Weight: 400g(14.10oz)withbattery
OptionalAccessories: LineSplitter(R5400)
ThermocoupleAdapter(AD-1)
SoftCarryingCase(CA-05A)
SoftCarryingCase(C-820)
SafetyTestLeadSet(TL-88-1)
FusedTestLeadSet(FC-300)
Electrical Specifications
Theaccuracyspecicationisdenedas±(…%ofreading+…count)at
23±5°C,
=
<
80%RH
TRMSforACVandACAaccuracyarespeciedfrom5%to100%ofthe
range.Fortheaccuracyadd±(1%ofreading)onCrestFactor1.4<CF<3
atfullscale&CF<6athalfscale.
ACA
Range Resolution Accuracy Overload Protection
40A 0.01A
50 ~ 60Hz
±(1.9%rdg+
5digits)
60 ~ 500Hz
±(2.5%rdg+
5digits)
1200Arms400A 0.1A
1000A 1A
DCA
Range Resolution Accuracy Overload Protection
40A 0.01A
±(2.5%reading+10digits) 1200Arms400A 0.1A
1000A 1A
ACV (Autorange)
Range Resolution Accuracy Overload Protection
400V 0.1V ±(1.5%reading+5digits)
50 ~ 500Hz 1000Vrms
750V 1V
continued ...
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
6
INSTRUMENTS
INSTRUMENTS
DCV (Autorange)
Range Resolution Accuracy Overload Protection
400V 0.1V ±(1%reading+2digits) 1000Vrms
1000V 1V
Ohm (Resistance) (Autorange)
Range Resolution Accuracy Overload Protection
400Ω 0.1Ω ±(1%reading+2digits) 600Vrms
4000Ω 1Ω
(Diode)
Range TestCurrent OpenCircuitVoltage Overload Protection
1.7mAMax. 6VMax. 600Vrms
Continuity
Range ActiveRegion Overload Protection
<100Ω 600Vrms
Frequency (Hz) (Autorange)
Function Range Resolution Sensitivity Accuracy
A-Hz 4KHz 1Hz 2Arms
±(0.1%reading+
1digits)(20~10KHz)
10KHz 10Hz 5Arms
V-Hz 4KHz 1Hz 5Vrms
±(0.1%reading+
1digits)(10~10KHz)
10KHz 10Hz 10Vrms
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
7
INSTRUMENTS
INSTRUMENTS
Instrument Description
1. CurrentSensingClamp
2. Clampopeninghandle
3. Function select dial
4. Hold Button
5. PeakHoldButton
6. MaximumMinimumButton
7. AC/DCSelectButton
8. Relative Button
9. LCDDisplay
10."COM"Terminal
11."+"TestTerminal
Display Description
AutoPowerOffindication
Lowbatteryindication
Direct Source indication
Alternative
PositivePeakdetectindication
Relative indication
NegativePeakdetectindication
Manual range indication
Data Hold indication
Diode function indication
Continuitywithbeeper
Polarity indication
AnalogBardisplay
Resistance
measurement indication
Voltage&Current
measurement
indication
Frequency
measurement indication
continued ...
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
8
INSTRUMENTS
INSTRUMENTS
Operating Instructions
Data Hold Function
Press the HOLD button at any time to hold the current reading. To release
thedatabeingheld,simplypresstheHOLD button again.
Peak Hold Function
Thismeterisdesignedwith1mspeakholdfunctionatACA,ACV,DCA
andDCVranges.Beforeperformingapeakholdoperation,acalibration
process must be completed rst.
Todothis,pressandholdthePEAKbuttonfor2seconds."CAL"will
displayontheLCDandtheoffsetwillbecalculatedandkeptinthemeter.
Afterthecalibrationiscomplete,youcanchooseP+orP-bypressing
the PEAK + HOLDbuttonstokeepthepeakreading.Toreturnthemeter
backtonormaloperation,pressthePEAK button for 2 seconds.
Whenthefunctionrangechanges,themeterwillrequireanother
calibrationforpeakmeasurement.
MAX/MIN Function
ThismeterisdesignedwithaMAX/MINfunctionatACA,ACV,DCAand
DCVranges.
Press the MAX/MINbuttononcetosetthemetertotheMAXmode.
Press it once again to set the meter to MIN mode. Press it once again and
themeterwilldisplaythepresentreadingandwillcontinuetrackingthe
MAXandMINchanges.Thismodewillalsobeindicatedwiththeblinking
"MAX/MIN"symbol.
SetthemeterbacktonormaloperationbypressingtheMAX/MIN button
for more than 2 seconds.
continued ...
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
9
INSTRUMENTS
INSTRUMENTS
REL Function
ThismeterisdesignedwithRELfunctionatACA,ACVandDCV,DCAranges.
Press the REL button to change the zero to the current reading and the
relativevaluewillshowontheLCD.Pressitonceagainandthemeter
will display the relative zero point. This mode will also be indicated with a
blinkingREL symbol.
SetthemeterbacktonormaloperationbypressingtheREL button for
more than 2 seconds.
Measurement Procedures
Current Measurement
Switch the main function selector to proper current range.
ACA
Open the clamp by pressing the jaw-opening handle and insert the cable
tobemeasuredintothejaw.ChooseACcurrentmeasurementby
pressing the AC/DCbuttonforACAreadings.
DCA
TomeasureDCcurrent,choose
DCmeasurementbypressing
the AC/DC button. Wait for the
reading to stabilize then press the
REL button to reset the reading.
Oncecompleted,insertthecable
to be measured into the jaw and
read the value.
Note:Beforetakingthismea-
surement,disconnectthetest
leads from the meter for safety.
Ifthereadingisdifculttoread,
push the HOLD
button and read the
result later.
continued ...
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
10
INSTRUMENTS
INSTRUMENTS
Voltage measurement
SwitchthemainfunctionselectortoVoltageRange.ConnecttheRedtest
leadtothe"+"terminalandtheBlackonetothe"COM"terminal.Choose
ACorDCbypressingtheAC/DCbutton.Measurethevoltagebytouching
the test lead tips to the test circuit where the value of voltage is needed.
ReadtheresultontheLCDpanel.
Resistance measurement
Switchthemainfunctiontothe"Ω"range,
verify that the power line is disconnected from
thesystem.ConnecttheRedtestleadtothe
"+"terminalandtheBlackonetothe"COM"
terminal.Connectthetipsofthetestleadsto
the points where the value of the resistance is
needed.ReadtheresultontheLCDpanel.
Note: When measuring the resistance value of
acircuitsystem,makesurethepowerisoff
andallcapacitorsrequiredaredischarged.
continued ...
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
11
INSTRUMENTS
INSTRUMENTS
Continuity Test
Switch the main function to
the" "range,verify
that the power line is
disconnected from the
system.ConnecttheRed
test lead to the "+"terminal
andtheBlackonetothe
"COM"terminal.Connect
the tips of the test lead to
the points where the value of
the conduction condition
is needed. If the resistance
isunder100Ω,thebeeper
will sound continuously.
Diode Test
Switch the main function to the
""range,verifythatthe
power line is disconnected from the
system.ConnecttheRedtestleadto
"+"terminalandtheBlackonetothe
"COM"terminal.Connectthetipsof
the Red test lead to the anode side and
theBlacktestleadtothecathodeside
of the diode being tested. Read the
forwardVoltage(Vf)valueonthe
LCDpanel.
If the polarity of test leads are reversed
withdiodepolarity,thedigital
readingwillshow"OL".Thiscanbe
used for distinguishing between anode
and cathode terminals of a diode.
Beeper
Short circuit
continued ...
Open circuit
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
12
INSTRUMENTS
INSTRUMENTS
Frequency measurement from
the terminals
Switchthemainfunctiontothe"Hz"
range.ConnecttheRedtestleadtothe
"+"terminalandtheBlackonetothe
"COM".Connectthetipsofthetest
leadstothepointswherethefrequency
ofthevoltagesignalisrequired.Read
thevalueonetheLCDpanel.
Frequency measurement with
the clamp
Switchthemainfunctiontothe"Hz"
range. Open the clamp by pressing
the clamp-opening handle and insert
the cable to be measured into the
clamp.Closetheclampandyouwill
ndthereadingontheLCDpanel.
Note:Whentakingfrequency
measurements,youshouldeitheruse
the terminal signal or clamp signal
but not both. If both sources are
applied an error reading will occur.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
13
INSTRUMENTS
INSTRUMENTS
Battery Replacement
1)Whenthebatteryvoltagedropsbelowtheproperoperationrangethe
symbolwillappearontheLCDdisplay,indicatingthatthebattery
needs to be changed.
2)Beforechangingthebattery,switchthemainfunctionto"OFF"and
disconnect the test leads.
3)Openthebackcoverusingascrewdriver.
4)Replacetheoldbatterywithanew9Vbattery.
5)Closethebackcoverandfastenthescrewsusingascrewdriver.
Product Maintenance
WARNING!
Beforeopeningthemeter,disconnectbothtestleadsandneveruse
the meter before the cover has been reinstalled and fastened.
Toavoidcontaminationorstaticdamage,donottouchthecircuit
board without proper static protection.
Notes:
•
Ifthemeterisnotgoingtobeusedforalongtime,takeoutthebatteryand
do not store the meter in high temperature or high humidity environment.
• Whentakingcurrentmeasurements,keepthecableatthecenterofthe
clamp to yield a more accurate test result.
• Repairsorservicingnotcoveredinthismanualshouldbeperformed
onlybyqualiedpersonal.
• Tocleanthemeter,periodicallywipethecasewithadrycloth.Donot
use abrasives or solvents on these instruments.
ForserviceonthisoranyotherREEDproductorinformationonother
REEDproducts,contactREEDInstrumentsatinfo@reedinstruments.com.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com
Other manuals for R5050
1
Table of contents
Other REED Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Industrial physics
Industrial physics sheen DV2300 operating instructions

Zehntner
Zehntner ZVR 6000 instruction manual

Crompton
Crompton Tyco Electronics SWITCHBOARD INTEGRA 1540 Installation and operating instructions

Burkert
Burkert ELEMENT 8228 operating instructions

METER GROUP
METER GROUP AquaLab 4TE DUO quick start

Avisoft
Avisoft UltraSoundGate 416-200 user guide