REED R6200 Manual

reedinstruments
www com
Model
Instruction
Manual
INSTRUMENTS
INSTRUMENTS
WBGT Heat Stress Meter
R6200
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
2
INSTRUMENTS
INSTRUMENTS
Table of Contents
Features.......................................................................................................2
Specications.......................................................................................... 3-4
Product Description ................................................................................ 4-5
Operating Instructions........................................................................... 6-12
Features
• Measuresambienttemperature,humidity,wetbulbtemperature,black
globetemperature,WBGT(wetbulbglobaltemperature),heatstress
index,dewpointandpressure
• HeatStressIndexmeasureshowhotitfeelswhenhumidityiscombined
withtemperature,airmovementandradiantheat
• BlackGlobeTemperature(GT)monitorstheeffectsofdirectsolar
radiationonanexposedsurface
• In/OutfunctiondisplaystheWBGTvaluewithorwithoutdirectsun
exposure
• Multi-linebacklitLCDdisplaysimultaneouslydisplays4measurements
• Maximum,Minimum,AverageandDataHoldfunctions
• Internalmemorystoresupto99measurements
• Userselectableunitofmeasure(°For°C)
• UseradjustableWBGTthresholdalarm(audible)
• Tripodmountforlong-termmonitoring
• Lowbatteryindicatorandautoshutoff
• Includesbatteries
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
3
INSTRUMENTS
INSTRUMENTS
Specifications
Temperature
MeasuringRanges AirTemperature:32to122°F(0to50°C)
BlackGlobe:32to176°F(0to80°C)
WBGT(Indoor):59to138.2°F(15to59°C)
WBGT(Outdoor):59to132.8°F(15to56°C)
Accuracy AirTemperature:±1.1°F(±0.6°C)
BlackGlobe:±0.6°C(20~50°C),other±1°C
WBGT(Indoor):±2.7°F(±1.5°C)
WBGT(Outdoor):±3.6°F(±2°C)
Resolution 0.1°F/°C
Humidity
MeasuringRanges 0-99.9%RH
Accuracy(@25°C) 10%to70%RH:±3%
RestofRange:±5%
Resolution 0.1%RH
BarometricPressure
MeasuringRange 300-1100hPa(inHg,mmHgswitchable)
Accuracy ±1.5hPa
Resolution 1hPa,0.1inHg,0.1mmHg
GeneralSpecications
DewPoint/
WetBulbCalculation Yes
ResponseTime 1sec
Display LCD
Backlight Yes(non-condensing)
DataHold Yes
Min Yes
Max Yes
Average Yes
InternalMemory Yes,upto99measurements
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
4
INSTRUMENTS
INSTRUMENTS
AutoShut-Off Yes(after15mins/off)
UserAdjustable
WBGTAlarm Yes(audible)
TripodMountable Yes
LowBatteryIndicator Yes
PowerSupply 4xAAAbatteries,OptionalACAdapter
ProductCertications CE,RoHS
OperatingTemperature 32to122°F(0to50°C)
OperatingHumidity <80%(non-condensing)
StorageTemperature -4to122°F(-20to50°C)
StorageHumidity <90%(non-condensing)
Dimensions Instrument:6.4x2.3x1.3”
(162x58x32mm)
BlackBrassBallDiameter:2.0”(50mm)
Weight 4.8oz(136g)
Product Description
LCD Display
a. RelativeHumidity
b. AmbientTemperature
c. GT:Blackglobe
temp.(BrassBall)
WBGT:Wetbulb
globaltemp.
HI:Heatindex
DPT:Dewpoint
temp.
WB:Wetbulbtemp.
d. BarometricPressure
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
5
INSTRUMENTS
INSTRUMENTS
Key Pad
Button Description
PWR Powerinstrumentonoroff/Activateorinactivateaudible
beeping
HOLD Freezecurrentmeasurementsondisplay/Increasedigit/
Scrollforward
BKLT Turnbacklightonoroff/Decreasedigit/Scrollbackwards
/Changepressureunit
MAX/MIN ReviewMax,Min,andAveragereadings
MODE
EnterWBGTalarmvaluesetting/Togglebetween
temperaturemodes:
GlobalTemperature(GT)
WetBulbGlobalTemperature(WBGT)
Heatindex(HI)
DewPoint(DP)
WetBulbTemperature(WB)
SET Changepressurevalue/Recordmeasurementsto
memory
UNIT ToggleTemperatureunitbetween°Cand°F/Select
desireddigitwhensettingalarmthreshold
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
6
INSTRUMENTS
INSTRUMENTS
Operating Instructions
POWER ON/OFF
Pressthe”PWR”buttontoturnthemeteron,
pressandholdfor2secondstoturnthemeter
off.
Whenthemeterispoweredon,theLCDdisplays
theWBGTmodeandthepreviouslyselected
“IndoororOutdoor”WBGTmeasurement
mode.Shortlyafter,abeepwillsoundandthe
instrumentwillbegintakingmeasurements.
MAX/MIN/AVG
Pressthe MAX/MIN buttontocyclethedisplay
throughtheMaximum,Minimum,Average
measurementsofAmbientTemperature,Global
TemperatureandRelativeHumiditysincethe
instrumentwaspoweredon.
PressandholdtheMAX/MINbuttonuntil“CLr”
appearsonthebottomofLCD.Theinstrumentwill
automaticallyreturntonormalmeasurementmode
oncethereadingshavecleared.
INDOOR/OUTDOOR Temperature MODE SELECTION
Wheninthe WBGTmode,pressandholdtheUNITbuttontotoggle
betweenindoororoutdoortemperature.Theinstrumentautomatically
calculatesthemeasurementusingthefollowingparameters:
a. OutdoorformulaWBGT=0.7Tw(wetbulbtemp)+0.2Tg(globe
temp)+0.1Td(airtemp.)
b. IndoorformulaWBGT=0.7Tw(wetbulbtemp)+0.3Tg(globe
temp)
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
7
INSTRUMENTS
INSTRUMENTS
SWITCH UNIT OF TEMPERATURE °C/°F
PresstheUNITbuttontoswitchbetween°Cand°F.
SWITCH UNIT OF PRESSURE
PresstheBKLTbuttontochangethepressuremeasuringunit.(hpa-->
inHg-->mmHg).
TEMPERATURE DISPLAY MODES
PresstheMODEbuttontotogglethroughtheGT(Globetemperature)-->
WBGTtemperature-->HI(Heatindex)-->DPT(Dewpoint)-->WB(Wet
bulbtemperaturemeasurements).
NOTE: Verify the meter is not displaying the MAX/MIN/AVG. If so,
press the MAX/MIN button until the icons have disappeared.
FREEZE READING
PresstheHOLDbuttonundernormalmeasurementanda“HLD” icon
appearsonthedisplaytoindicatethatthemeterisinDataHold.When
thisfeatureisturnedon,theonlyfunctionalityavailableistheabilityto
switch between units of pressure, temperature and scrolling through
the temperature display modes“GT/WBGT/HI/DPT/WB”.
AUTO-POWER OFF
Themeterwillautomaticallyturnoffwhennotinuseforaperiodof15
minutes.TodisabletheautopowerofffunctionpresstheHOLD and PWR
buttonsatthesametime.TheLCDwillmomentarilydisplay“n” indicating
theauto-powerofffeatureisdisabled.
BACKLIGHT FUNCTION
Pressandholdthe“BKLT”buttontoactivateorinactivatebacklight
function.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
8
INSTRUMENTS
INSTRUMENTS
INTERNAL MEMORY
The R6200 has the ability to record up to 99
points internally.
a. PresstheSETbuttontosaveareading
(Temp.RH).
b. TheRECiconshowswilldisplaynextto
thetemperaturereadingandrecordnumber
showsonthebottomofLCDfor2seconds.
To recall recorded data:
a. PressandholdtheMODEbuttontoreviewmemoryTemperature,
RHandrecordednumber.
b. KeeppressingtheHOLDbuttontoreviewnextdataorpressand
holdtheBKLTbuttontoreviewthelaststoreddataentry.
c. PresstheMODEbuttontwice,toescapememoryfunction.
d. Underdatarecallmode,pressandholdtheSETbuttontoclearthe
memory.LCDwillshow“---”.
WBGT AUDIBLE ALARM THRESHOLD SETTING
(The default WBGT temperature alarm value is set at 31°)
a. PressandholdtheMODEbuttonfor2
secondsandthemeterwillentermemory
recallmode.
b. PressandholdMODEbuttonagaintoenter
WBGTalarmmode.
c. PresstheHOLDbuttontoincreasethevalue,
presstheUNITbuttontoselectthenextdigit.
d. PresstheBKLTbuttontodecreasethevalue,
presstheUNITbuttontoselectthenextdigit.
e. Oncethealarmisselected,pressandhold
theMODEbuttontosavethevalueand
returntonormalmeasurementmode.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
9
INSTRUMENTS
INSTRUMENTS
TURN ON/OFF ALARM FUNCTION
Aftersettingupthethreshold,pressthePWRbuttonandthebellicon
willdisplayonthescreenindicatingthealarmisactivated.PressthePWR
buttonagaintodisablealarmfunction.
GLOBAL TEMPERATURE/AMBIENT TEMPERATURE/
HUMIDITY OFFSET FUNCTION
Itisrecommendedthatthisunitbecalibratedonceayeartoensure
measurementsstaywithinmanufacturer’sspecications.Inthecasethat
auserwouldliketoperformself-vericationwithatrustedcalibration
sourcethefollowingoffsetprocedureshavebeenprovided.
Toentertheoffsetmode:
a. PowerOFFthemeter.
b. PressandholdtheMODE and BKLTbuttons.
c. PressthePOWERbuttonuntilthescreenshowsall3parametersin
“0.0”,thenreleasetheMODE+BKLTbuttons.
NOTE: To offset temperature in °F, hold MAX/MIN and press the
POWER button to select °C or °F.
Globe temperature offset
• HoldtheUNITbuttonandpresstheHOLD
buttonatthesametimetoincreasethevalue.
• HoldtheUNITbuttonandpresstheBKLTbutton
atthesametimetodecreasethevalue.
• PresstheMODE and POWERbuttonstosave
thevalue.
• Repowerthemetertoreturnnormal
measurementmode.
Ambient temperature offset
• HoldtheSETbuttonandpresstheHOLDbuttonatthesametimeto
increasethevalue.
• HoldtheSETbuttonandpresstheBKLT buttonatthesametimeto
buttonandthebellicon
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
10
INSTRUMENTS
INSTRUMENTS
decreasethevalue.
• PresstheMODE and POWERbuttonstosavethevalue.
• Repowerthemetertoreturnnormalmeasurementmode.
Relative Humidity Offset
• HoldtheMAX/MINbuttonandpresstheHOLDbuttonatthesame
timetoincreasethevalue.
• HoldtheMAX/MINbuttonandpresstheBKLTbuttonatthesametime
todecreasethevalue.
• PresstheMODE and POWER buttonstosavethevalue.
• Repowerthemetertoreturnnormalmeasurementmode.
Pressure Offset Function
a. PressandholdtheSETbuttonuntilthe
LCDshows“0.0 hpa”.
b. ToincreasethevaluepresstheHOLD
button.
c. TodecreasethevaluepresstheBKLTbutton.
d. PressandholdthePOWERbuttontosavethesetvalue.
e. TheLCDwilldisplay“SAVE”andreturntonormalmeasurement
mode.
NOTE: The compensation range is ±3 hpa.
ERROR CODE
Code Description
Er1: Sensorfailed.
Er2: Outofmeasuredrange.
Low Battery Indicator
WhenthebatteryislowtheLCDwilldisplay“bAt”.Itisrecommendedto
stopuseimmediatelyandreplacethebatteries.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
11
INSTRUMENTS
INSTRUMENTS
Forserviceand/orinformationonthisoranyotherREEDproduct,contact
REEDInstrumentsatinfo@reedinstruments.com.
Notes __________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
12
INSTRUMENTS
INSTRUMENTS
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com
Table of contents
Other REED Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Optima Scale
Optima Scale OP-907A user manual

Thermo Scientific
Thermo Scientific FOCUS GC instruction manual

BRONKHORST
BRONKHORST ES-FLOW instruction manual

Cooper Electronics
Cooper Electronics BusAlyzer user manual

Proxitron
Proxitron OKS L Q18.194 S10 user manual

Rice Lake
Rice Lake Dyna-Link 2 MSI-7300 Technical manual

Keysight Technologies
Keysight Technologies ENA Series Service note

Emerson
Emerson Penberthy Multiview Installation, operation and maintenance instructions

Silverline
Silverline 482913 quick guide

ABB
ABB C13 installation manual

Extech Instruments
Extech Instruments RH520 user manual

Kilews
Kilews KTM-IWT50 operating manual