6Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove
INSTALLATION
8) Any safety glass removed for servicing
must be replaced prior to operating the
appliance.
9) Topreventinjury,donotallowanyonewho
is unfamiliar with the operation to use the
fireplace.
INSTALLATION
CHECKLIST
1) CheckClearancestoCombustibles(pages
6 and 7), location of unit (page 7) and
venting requirements (pages 7 to 9).
2) Install Louvers, page 7.
3) Install venting, either with the DV Stove
Horizontal Vent Kit (page 10) or the Dura-
Vent Termination kits (page 12). Set Vent
Restrictors,page9. If convertingaClass-
A Metal Chimney or Masonry Chimney to a
Direct Vent system, see instructions on
pages 19 to 21.
4) Make gas connections, page 21. Test the
pilot. Must be as per diagram, page 29.
5) Ifnecessary,converttoPropane(page22)
or convert to lower Btu rating (page 23).
6) Test Gas Pressure, page 23.
7) Install log set, see page 24.
8) Install Front Door Front, page 25.
9) InstalloptionalRemoteControl,orWallTher-
mostat, page 26.
10)Final check, page 27.
Before leaving this unit with the customer, the
installermustensurethattheapplianceisfiring
correctly and operation fully explained to
customer.
This includes:
1) Clocking the appliance to ensure the cor-
rect firing rate (rate noted on label) after
burning appliance for 15 minutes.
2) If required, adjusting the primary air to
ensurethattheflamedoesnotcarbon.First
allow the unit to burn for 15-20 min. to
stabilize.
CAUTION: Any alteration to the product
that causes sooting or carboning that
resultsindamageisnottheresponsibil-
ity of the manufacturer.
into a manufactured home the unit must be
bolted down to the floor.
4) ThisapplianceisListedforbedroom instal-
lations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
5) Thisappliance isListed forAlcove installa-
tions,maintainminimumAlcove clearances
asfollows, minimumwidthof48"(1219mm),
a maximum depth of 36" (914mm), and
minimum ceiling height of 64"(1626mm).
6) We recommend that you plan your installa-
tion on paper using exact measurements
for clearances and floor protection before
actually installing this appliance. Have a
qualified building inspector review your
plans before installation.
GENERAL SAFETY
INFORMATION
1) The appliance installation must conform
with local Canadian Electrical Code.
2) Theappliancewheninstalled,mustbeelec-
trically grounded in accordance with local
codes,orintheabsenceoflocalcodeswith
the current National Electrical Code, ANSI/
NFPA 70 or CSA C22.1 Canadian Electrical
Code.
3) The appliance should be inspected for
shippingdamagebeforeuseandserviced
annually by a professional service
person. More frequent cleaning may be
required due to excessive lint from carpet-
ing,beddingmaterial,etc.Itisimperativethat
control compartments, and circulating air
passageways of the appliance be kept
clean and free from excessive lint from
carpeting.
4) See general construction and assembly
instructions.Theapplianceandventshould
be enclosed when installed in or passing
through a living area, where children may
come in contact with it.
5) This appliance must be connected to the
specified vent and termination cap to the
outsideofthebuildingenvelope.Nevervent
to another room or inside a building. Make
surethattheventisfittedaspertheinstruc-
tions starting on page 7.
6) Inspect the venting system annually for
blockage and any signs of deterioration.
7) Ventingterminalsshallnotberecessedinto
a wall or siding.
CLEARANCES TO
COMBUSTIBLES
The clearances listed are MINIMUM distances.
Measure the clearance to both the appliance
and the chimney connector. The farthest
distance is correct if the two clearances
do not coincide.
Forexample,iftheapplianceissetasindicated
in one of the figures but the connector is too
close, move the stove until the correct clear-
ance to the connector is obtained.
This appliance may be installed only with the
clearancesasshowninthesituationspictured.
Donotcombineclearancesfromonetype
of installation with another in order to
achieve closer clearances.
Thisunitcanbe installedonasolidcombustible
surfacelike awoodfloor. Thisunit canalso be
installeddirectlyoncarpeting orvinylwhenthe
bottompedestalcoverplate(providedwithunit)
is installed.
Use the minimum clearances shown in the
diagrams below:
U39-NG & U39-LP Clearances
ASide Wall to Unit 7-1/2"/190mm
BBack Wall to Unit 6" / 150 mm
ESide Wall to Unit 2" / 50 mm
U39-NG & U39-LP Reference
Dimensions
CBack Wall to Flue Centerline 11"/280 mm
DSide Wall to Flue Centerline 20-1/2"/521 mm
FSide Wall to Flue Centerline 11"/280 mm
Minimumceiling heightis36" /914 mmfrom top
of unit.
Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.