1 - Description
RBC HP Storage water heater (further “tank“) with one upsized enameled heating coil with a G 5/4” connection
(750, 1000 and 15000 l tanks have a G 6/4” connection). These tanks (except for the 1000 and 1500 l models)
facilitate installation of an electric heating element into the G 6/4” sleeve.
These tanks with an upsized heating coil are especially suitable for use with a heat pump.
In order to reach proper working of the tank, it is necessary to design optimum hydraulics of the whole system,
i.e. position of circulation pumps for sources and heating circuits, valves, non-return valves etc.
1.1 - Models
Seven models of 205, 299, 407, 509, 764, 884 and 1516 l capacity enabling installation of an electric heating
rod or another heat source.
1.2 - Tank protection
Enameled inner surface and coil guarantee long service life. Enamel is done according to DIN 4753 standard.
Further qualitative improvement is reached thanks to a magnesium anode rod installed inside the tank (bigger
tanks are tted with more anode rods). From 400 l upwards the tanks are tted with 2 magnesium anode rods,
tanks of 750, 1000 a nd 1500 l volume with 3 magnesium anode rods.
1.3 - Thermal insulation
Tanks up to 500l are supplied with a hard polyurethane insulation 55 mm thick with a white PVC surface. 750
and 1000l tanks are supplied with a hard polyurethane insulation 75 mm thick with white PU leather surface.
1500 l tank features 100 mm thick insulation.
1.4 - Connection points on the tank
2× lateral with G 5/4“ inner thread, for the heating coil (750, 1000 and 1500 l tanks have a G 6/4” thread)
2× lateral with G 5/4“ inner thread, for cold water inlet and hot water outlet (200, 300 and 400 l tanks have
a G 1” thread, 1500 l tank has a G 2”)
2× lateral with G 1/2“ inner thread, for a temperature sensor and thermometer (RBC 1000 HP and RBC 1500
HP tanks have one extra sheath)
1× lateral with G 1“ inner thread, for circulation (200, 300 and 400 l tanks have a G ¾” thread)
1× top with G 5/4“ inner thread, for a magnesium anode rod (750, 1000 and 1500 l tanks have 2 upper anode
rods)
1× lateral with G 6/4“ inner thread, for an el. heating rod (not in RBC 1000 HP and RBC 1500 HP)
1× ange for the lateral inspection hole
1.5 - Packaging
Tanks are delivered standing, each screwed to its pallet, packed in bubble wrap. It is forbidden to transport
and/or store the storage tanks in a horizontal position.
2 - General Information
The appliance shall be installed by a qualied person according to valid rules and Manufacturer‘s Instructions.
This Owners Manual is an integral and important part of the product and must be handed over to the User.
Read carefully the instructions in this Manual as they contain important information concerning safety,
installation, operation and maintenance. Keep this Manual for later reference.
Using the tank for other purposes than stated above is forbidden and the manufacturer accepts no
responsibility for damage caused by improper or wrong use.