© 1996 Renishaw plc Printed in England Ref. IG IMP (E) 1m 03.01 Part No. H-2000-4037-01-C
IMP
Inductive module probe
Part No A-2028-7574 + derivatives
H-2000-4037-01-C
WARRANTY
Equipment requiring attention under warranty
must be returned to your supplier. No claims will
be considered where Renishaw equipment has
been misused, or repairs or adjustments have
been attempted by unauthorised persons.
CHANGES TO EQUIPMENT
Renishaw reserves the right to change
specifications without notice.
IP RATING IP67
ENVIRONMENT
Temperature
The IMP is specified for storage over
–10° to 70°C (14 to 158°F) and operation
over 5° to 60°C (41° to 140°F) ambient
temperature range.
GARANZIA
Apparecchiature che richiedano interventi durante
il periodo di garanzia, devono essere inviate al
Vostro fornitore.
La garanzia non sarà considerata valida qualora
l'apparecchiatura Renishaw sia stata maltrattata,
o sia stata riparata o regolata da personale non
autorizzato.
MODIFICHE ALLE APPARECCHIATURE
La Renishaw si riserva il diritto di apportare
modifiche alle apparecchiature senza preavviso.
CLASSIFICAZIONE IP IP 67
AMBIENTE
Temperatura
La temperatura ambiente di deposito specificata
per è compresa tra –10° e 70°C, e la temperatur
a d'esercizio è compresa tra 5° e 60 °C.
GARANTIE
L'équipement à réparer sous garantie doit
être renvoyé à votre fournisseur.
Aucune réclamation concernant l'équipement
Renishaw ne sera étudiée en cas d'utilisation
impropre, de réparations ou de réglages effectués
par toute personne non autorisée.
MODIFICATION DE L'EQUIPEMENT
Renishaw se réserve le droit de modifier les
spécifications de l'équipement sans préavis.
CONFORMITE IP IP67
ENVIRONNEMENT
Température
Le IMP est conçu pour une conservation
à température ambiante comprise entre
–10° et +70°C et une exploitation à température
ambiante comprise entre 5° et 60°C.
GARANTIE
Teile, die während der Garantiezeit Mängel
aufweisen, müssen an den Lieferanten
zurückgesandt werden.
Die Garantieansprüche verfallen bei
Fehlbedienung oder unsachgemäßem Eingriff.
Technische Änderungen
Technische Änderungen vorbehalten.
Dichtheit IP67
Umgebungsbedingung
Temperatur
Arbeitstemperatur –10° – 70°C
Lagertemperatur 5° – 60°C
This product conforms to the following European standards:
BS EN 50081-2 and BS EN 50082-2.
It complies with the relevant essential health and safety and protection
requirements of the following EC Directives:
89/336/EEC as amended (EMC), and 93/68/EEC (CE MARKING).
Important
All relevant safety information, including that incorporated in the installation
instructions, user instructions and maintenance instructions must be observed.
Ce produit est conforme aux normes Européennes suivantes :
BS EN 50081–2 et BS EN 50082–2.
Il se conforme aux prescriptions de santé et sécurité et aux
recommandations de protection des directives suivantes de l'UE:
89/336/EEC modifiée (CEM) et 93/68/EEC (MARQUAGE CE).
Important
Toutes les consignes de sécurité pertinentes, y compris celles figurant aux
paragraphes concernant l'installation, l'utilisation et la maintenance du bloc
d'alimentation doivent être suivies.
Dieses Produkt entspricht den folgenden europäischen Normen
BS EN 50081-2 und BS EN 50082-2.
Dies beinhaltet auch alle für das Produkt zutreffende Gesundheits-,
Sicherheits- und Schutzvorschriften gemäß den EG-Richtlinien:
89/336/EEC und 93/68/EEC (CE Kennzeichnung).
Wichtig
Alle Sicherheitshinweise im Handbuch, in den Kapiteln Installation,
Bedienung und Wartung, müssen beachtet werden.
Questo prodotto é conforme ai seguenti standard Europei:
BS EN 50081–2 e BS EN 50082–2.
L'apparecchiatura è conforme ai requisiti di protezione e di antinfortunistica della
normativa EEC: 89/336/EEC ed emendamenti (CORRENTE ELETTROMAGNETICA)
e 93/68/EEC (MARCHIO CE).
Avvertenza
E' essenziale osservare le informazioni di antinfortunistica, comprese quelle contenute
nelle sezioni relative all'installazione, al funzionamento ed alla manutenzione.
FCC Section 15.19
This device complies with Part 15 of the FCC rules. Operation is subject to the
following two conditions:
1. This device may not cause harmfull interference.
2. This device must accept any interference received, including interference that
may cause undesired operation.
FCC Section 15.105
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference,
in which case you will be required to correct the interference at your own expense.
FCC Section 15.21
The user is cautioned that any changes or modifications not expressly approved by
Renishaw plc, or authorised representative could void the user's authority to operate
the equipment.
FCC Section 15.27
The user is also cautioned that any peripheral device installed with this equipment
such as a computer, must be connected with a high quality shielded cable to insure
compliance with FCC limits.
FCC DECLARATION (USA)
Installation Guide
Renishaw plc, New Mills, Wotton-under-Edge,
Gloucestershire GL12 8JR, United Kingdom.
International Tel +44 1453 524524 National Tel 01453 524524 [07000 RENISHAW]
International Fax +44 1453 524901 National Fax 01453 524901
Internet http://www.renishaw.com email [email protected]
Telex 437120 RENMET G
IMP Wires
Two separate insulated wires (each single core).
Outside diameter 1,0mm (0.039in).
Length 2000mm (78in).
Colours Pink and White.
Warning - DO NOT pull or repeatedly bend the wires during installation.
dimensions mm (in)
IMP MOUNTING
IMP GENERAL ARRANGEMENT
IMP INSTALLATION
The IMP is secured using flat ended grubscrews
(over clamping zone marked x x ),
or a semi-permanent adhesive.
RECOMMENDED GRUBSCREW TORQUE
Clamping screw size M4 maximum.
Clamping screw torque 0,25Nm (0.18 lbf.ft) maximum.
Warning - DO NOT use cone point screws for clamping.
RECOMMENDED ADHESIVE
Silicon RTV DOW CORNING Q3-3744 or equivalent.
IMPORTANT
Pressure may be applied to the metal housing around
the circumference, but the plastic front face should not
be subjected to direct pressure on installation.
Hold with flat plate until adhesive cures.
20,1 (0.791)
20,0 (0.787)
15 (0.59)
MINIMUM
Clamping zone
15°
Ø21 (0.83) 0,8 (32)
Ø
4,0 (0.157)
2,0 (0.078)
Ø6,5
(Ø0.26)
MAX
Ø19,95
(Ø0.785)
MAX
13,25 (0.52)
13,05 (0.51)
REF
16,25 (0.64)
MAX

This manual suits for next models

1

Other Renishaw Control Unit manuals

Renishaw SLM 250 Owner's manual

Renishaw

Renishaw SLM 250 Owner's manual

Renishaw MCR20 Installation instructions

Renishaw

Renishaw MCR20 Installation instructions

Renishaw TP200 User manual

Renishaw

Renishaw TP200 User manual

Renishaw OMM User manual

Renishaw

Renishaw OMM User manual

Renishaw HSI User manual

Renishaw

Renishaw HSI User manual

Popular Control Unit manuals by other brands

Raypak BACnet Interface Module Installation and operation manual

Raypak

Raypak BACnet Interface Module Installation and operation manual

Siemens SITRANS LU SAM instruction manual

Siemens

Siemens SITRANS LU SAM instruction manual

hager TN002 User instructions

hager

hager TN002 User instructions

Zodiac TRi pH Module Instructions for installation and use

Zodiac

Zodiac TRi pH Module Instructions for installation and use

Johnson Controls System 450 Series installation instructions

Johnson Controls

Johnson Controls System 450 Series installation instructions

Mosconi MOS USB2.0 quick start guide

Mosconi

Mosconi MOS USB2.0 quick start guide

RAK WisTrio LoRa Tracker user manual

RAK

RAK WisTrio LoRa Tracker user manual

ELPRO ECOLOG-PRO 2PTR Operation manual

ELPRO

ELPRO ECOLOG-PRO 2PTR Operation manual

Advanced Energy Thyro-Power Manager operating instructions

Advanced Energy

Advanced Energy Thyro-Power Manager operating instructions

SunFounder Super Kit 3.0 manual

SunFounder

SunFounder Super Kit 3.0 manual

TiEmme ART.6544DN Installation and operation instruction

TiEmme

TiEmme ART.6544DN Installation and operation instruction

Siemens SIMATIC TI525 Hardware and installation manual

Siemens

Siemens SIMATIC TI525 Hardware and installation manual

Tavistock Kinetic SKN0601 Installation & Aftercare Instructions

Tavistock

Tavistock Kinetic SKN0601 Installation & Aftercare Instructions

AsiaRF AW7915-NP1 manual

AsiaRF

AsiaRF AW7915-NP1 manual

Texas Instruments bq35100 Technical reference manual

Texas Instruments

Texas Instruments bq35100 Technical reference manual

Quantum ATL StackLink installation instructions

Quantum

Quantum ATL StackLink installation instructions

Linak JUMBO Care user manual

Linak

Linak JUMBO Care user manual

RJG Lynx OR2-M product manual

RJG

RJG Lynx OR2-M product manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.