REVENTON AERIS Series Guide

Technical documentation
UNHEATED AIR CURTAIN
MODELS:
AERIS 100C-1P
AERIS 150C-1P
AERIS 200C-1P

2. DEVICE CHARCTERISTICS
2.1 DIMENSIONS
1. INTRODUCTION
1.1 PRECAUTIONS
1.2 TRANSPORT
1.3 PACKAGE CONTENT
1.4 USE
2.DEVICE CHARCTERISTICS
2.1 DIMENSIONS
2.2 TECHNICAL DATA
3. INSTALLATION
3.1 GENERAL PRINCIPLES
3.2 ASSEMBLY „STEP BY STEP”
4. INSTALLATION INSTRUCTIONS
4.1 CONNECTION OF THE DEIVCE TO THE ELECTRICAL SYSTEM
5. PRECAUTIONS AND WARNINGS
6. CONTROL
7.CONNECTION SCHEMES
8.TERMS OF WARRANTY
1. INTRODUCTION
Thank you for purchasing air curtain AERIS. We would like to congratulate
on good choice. Please read and save these instructions.
1.1 PRECAUTIONS
The buyer and the user of the device should read carefully the following
instructions and proceed to the content recommendations. Proceeding
due to the following instruction guarantees the correct usage and safety. In case
of any doubts please contact Reventon Group sp. z o. o. [Ltd.]. The supplier
reserves the rights to make changes to the technical documentation without
previous notice. Reventon Group sp. z o. o. [Ltd.] is not responsible
for the damages which occur due to improper installation, not keeping the device
in repair or using the device out of line. The installation should be carried
out by the professional installers, who possess the qualifications to install
these types of devices. The installers are responsible for making the installation
as instructed in the technical data. Regulations and safety rules
must be followed. During the installation, use, service and periodical inspections
all regulations and safety rules must be followed. In case of unserviceable please
plug out the device and contact with the authorized person or the supplier.
All safety requirements must be taken into account during installation,
use or inspection.
1.2 TRANSPORT
During the acceptance of goods it is needed to check the device in order
to exclude any damages. During the transport it is needed to use the proper
equipment, it is necessary to carry the device by two people. In case
of any damages please fill in the damage report in presence of the supplier
or the carrier.
1.3 PACKAGE CONTENT
- unheated air curtain
- operation and maintenance manual and warranty card
- assembly panel
- door sensor
- remote controller
1.4 USE
Unheated air curtains (without heat exchanger) are widely installed
at the entrances of supermarkets, theaters, meeting rooms, hotels, offices,
storages etc. They can reduce penetration of insects, outside dust,
unconditioned air into a conditioned space by forcing an air stream over
the entire entrance. In winter they prevent uncontrolled heat loss and in summer
they prevent heat from the room. However, air curtains should not be used
in corrosive environments for aluminum, copper and steel as well as in highly
dusty environments (above 0.3 g/m ).The devices should also not be installed
in rooms where they would be exposed to high humidity or direct contact
with water.
ENG
T ECHNICAL DATA
3
2.2 TECHNICAL DATA
MODEL
REVENTON GROUP
AERIS 100C-1P
REVENTON GROUP
AERIS 150C-1P
REVENTON GROUP
AERIS 200C-1P
A B C D E F
1000
1500
2000
132
90 18.0
25.0
GN.W (KG)
13.5
440
--- ---
--- ---
330 330
247
218
H
440
660
AERIS 100C-1P AERIS 150C-1P AERIS 200C-1P
1770 3150 3540
1450 2550 2900
11 11 11
9 9 9
230/50 230/50 230/50
180 230 360
130 180 260
13.5 18.0 25.0
56 57 58
54 55 56
E / IP 20 E / IP 20 E / IP 20
0.78 1.00 1.57
0.57 0.78 1.13
3 3 3
II STAGE
I STAGE
II STAGE
I STAGE
II STAGE
II STAGE
I STAGE
II STAGE
I STAGE
II STAGE
I STAGE
TECHNICAL DATA
Product code
Maximum
airflow [m /h]
Maximum air speed
[m/s]
3
Curtain’s range [m]
Supply voltage [V] / Supply frequency [Hz]
Motor power [W]
Rated motor
current [A]
Class of isolation / Protection degree IP [-]
Net weight [kg]
Noise [dB]
AC100C1P AC150C1P AC200C1P

3. INSTALLATION
3.1. GENERAL PRINCIPLES
The following figures show minimum distances between the air curtain
and the building partition:
a) wall mounting
- unscrew the fixing screws to remove the mounting plate from the back
of the main body
- install mounting plate on the wall
4. INSTALLATION INSTRUCTIONS
4.1. CONNECTION OF THE DEIVCE TO THE ELECTRICAL SYSTEM
- all works concerning electrical installation should be made by the qualified
personnel (who possess required authorizations to install electrical equipment)
- plug should be put in an appropriate socket and if required, connect the door
switch according to wiring diagram (see point 7)
- the electrical installation of the building shall have a residual current device
- check the electrical installation before the first start
5. PRECAUTIONS AND WARNINGS
During operation of the device, the following must be respected:
- all works concerning electrical installation (disassembly, repair etc.) should
be made by the qualified personnel, who possess the qualifications
due to the domestic and local norms, regarding electrical installations
- do not limit or cover the inlet and outlet of the device
- do not install, service the device with wet hands or barefoot
- the device should be kept out of reach of children and animals
- after the turn off, the elements of device may be warm
- after operating time of the device, please utilize it concerning the local norms
and regulations
-install the main body. Set the main body onto the upper end of the mounting
plate and clamp it as shown
The width of the curtain should be greater or equal to the width of the door
frame. When the entrance is wider than the unit, it is recommended to install two
or more units in parallel. In this case, provide 10-40 mm gaps between the units.
3.2. ASSEBLY “STEP BY STEP”
The curtain can be assembled on wall or ceiling. If any components
are not included in the kit, you should buy them yourself and make sure
they are suitable for this type of installation.

- don’t allow water or any liquid to enter the motor
- maintenance and repair work must be carried out by a qualified personnel
familiar with local regulations and standards
- always unplug or disconnect the appliance from the power supply before
installation, servicing or cleaning the unit
- never use petrol, benzene, thinners or any other chemicals for cleaning the unit
- periodic maintenance work should be carried out at least once a year by:
ź cleaning of plastic parts with water with the addition of soap
ź cleaning the casing with a soft cloth
- failure to comply with cleaning obligations may have a negative effect
on technical parameters of the device and lead to loss of warranty
- if the device is not used for a longer time disconnect the voltage supply
- if any abnormality happens, turn off the product immediately and check
the problem
6. CONTROL
The curtain can be controlled by the remote controller or control panel, located
on the housing with three buttons ON/OFF, L and H:
- ON/OFF button allows to turn on / off the device
- L button enables to choose I motor stage (low speed)
- H button is used to switch the motor speed to high one (II stage)
NOTES
- the curtain make a sound 'beep' everytime when you press any buttom
(signaling the command acceptance)
7. CONNECTION SCHEMES
LEGEND:
1. Electric socket
2. Plug
3. Unheated air curtain AERIS C-1P
4. Door switch
blue blue

8. TERMS OF WARRANTY
I. Supplier grants the buyer a 24-month warranty period for the following devices:
- unheated air curtain AERIS 100C-1P
- unheated air curtain AERIS 150C-1P
- unheated air curtain AERIS 200C-1P
II. The terms of warranty are valid from purchasing the device (i.e. invoice /
another confirming document issue date) but not longer than 30 months from
leaving the supplier's warehouse.
III. To obtain the service it is needed to provide or send to the supplier scans
of the warranty card with stamp of installation company, document confirming
the purchase (eg. like copy of the invoice) and correctly filled the warranty form.
IV. The supplier is committed to consider the claim within 14 working days since
the date of reporting (i. e. day when documents given in point III are provided).
V. In the exceptional cases, the supplier reserves the right to extend the time limit
for examination of warranty, especially if the defect is not permanent
and its determination requires a longer period of time. The extension must
be notified by the supplier before the end of the 14th working day.
VI. Under the guarantee the supplier provides a repairment, replacement
or refund for the defective device within a specified time limit.
VII. Warranty does not cover the parts of the device subject to normal
maintenance and the following cases:
a) mechanical damage of the product
b) defects and damages through:
- improper storage or transport
- improper or non-compliant use and maintenance (i. e. inconsistent
with the manual)
- using the device in the improper conditions (too high humidity, too high
or too low temperature, impact of the surrounding, sun etc.)
- unauthorized (by the user or other unauthorized persons) repairs,
modifications or construction changes
- connecting equipment inconsistent with the technical documentation
- connecting additional equipment, which is not recommended by the supplier
- improper power supply
c) elements which wear and tear such as discolor of the housing
If there is any of the above, claimant will be charged for transport and / or repairs.
VIII. Any changes in the Warranty Terms, improper use of the product (careless
handling, exposure to liquids, moisture, corrosion), as well as traces
of selfrepairing (non by the Reventon Group) or alterations cause, the warranty
is not valid.
IX. Not following to any of warranty regulations makes the warranty not valid.
The supplier reserves the rights to make changes to the technical
documentation without previous notice.

Warranty card
:
:
::
:

This manual suits for next models
3
Table of contents
Other REVENTON Heater manuals

REVENTON
REVENTON AERIS 100WN-1P Guide

REVENTON
REVENTON Aeris Series Guide

REVENTON
REVENTON HUMMER SERIES Guide

REVENTON
REVENTON Farmer Series User manual

REVENTON
REVENTON AERIS 90EN-3P Guide

REVENTON
REVENTON AERIS 100E-1P Guide

REVENTON
REVENTON AERIS 100E-1P Guide

REVENTON
REVENTON AERIS 100EN-1P Guide

REVENTON
REVENTON AERIS 100E-1P Guide

REVENTON
REVENTON AERIS 90EN-3P Guide